首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Aeolian mineral dust archived in polar and mid latitude ice cores represents a precious proxy for assessing environmental and climatic variations at different timescales. In this respect, the identification of dust mineralogy plays a key role. In this work we performed the first preliminary X-ray absorption spectroscopy (XAS) experiments on mineral dust particles extracted from Antarctic and from Alpine firn cores using grazing incidence geometry at the Fe K-edge. A dedicated high vacuum experimental chamber was set up for normal-incidence and total-reflection X-Ray Fluorescence and Absorption Spectroscopy analyses on minor amounts of mineral materials at the Stanford Synchrotron Radiation Laboratory. Results show that this experimental technique and protocol allows recognizing iron inclusion mineral fraction on insoluble dust in the 1–10 µg range.  相似文献   

2.
Inductively coupled plasma mass spectrometry (ICP-MS) is a suitable tool for multi-element analysis at low concentration levels. Rare earth element (REE) determinations in standard reference materials and small volumes of molten ice core samples from Antarctica have been performed with an ICP-time of flight-MS (ICP-TOF-MS) system. Recovery rates for REE in e.g. SPS-SW1 amounted to ∼103%, and the relative standard deviations were 3.4% for replicate analysis at REE concentrations in the lower ng L−1 range. Analyses of REE concentrations in Antarctic ice core samples showed that the ICP-TOF-MS technique meets the demands of restricted sample mass. The data obtained are in good agreement with ICP-Quadrupole-MS (ICP-Q-MS) and ICP-Sector Field-MS (ICP-SF-MS) results. The ICP-TOF-MS system determines accurately and precisely REE concentrations exceeding 5 ng L−1 while between 0.5 and 5 ng L−1 accuracy and precision are element dependent.  相似文献   

3.
Measurements of Pb isotope ratios in ice containing sub-pg g−1 concentrations are easily compromised by contamination, particularly where limited sample is available. Improved techniques are essential if Antarctic ice cores are to be analysed with sufficient spatial resolution to reveal seasonal variations due to climate. This was achieved here by using stainless steel chisels and saws and strict protocols in an ultra-clean cold room to decontaminate and section ice cores. Artificial ice cores, prepared from high purity water were used to develop and refine the procedures and quantify blanks. Ba and In, two other important elements present at pg g−1 and fg g−1 concentrations in Polar ice, were also measured. The final blank amounted to 0.2 ± 0.2 pg of Pb with 206Pb/207Pb and 208Pb/207Pb ratios of 1.16 ± 0.12 and 2.35 ± 0.16, respectively, 1.5 ± 0.4 pg of Ba and 0.6 ± 2.0 fg of In, most of which probably originates from abrasion of the steel saws by the ice. The procedure was demonstrated on a Holocene Antarctic ice core section and was shown to contribute blanks of only ∼5%, ∼14% and ∼0.8% to monthly resolved samples with respective Pb, Ba and In concentrations of 0.12 pg g−1, 0.3 pg g−1 and 2.3 fg g−1. Uncertainties in the Pb isotopic ratio measurements were degraded by only ∼0.2%.  相似文献   

4.
A new method for the detection of trace elements in polar ice cores using laser ablation with subsequent inductively coupled plasma mass spectrometry analysis is described. To enable direct analysis of frozen ice samples a special laser ablation chamber was constructed. Direct analysis reduces the risk of contamination. The defined removal of material from the ice surface by means of a laser beam leads to higher spatial resolution (300– 1000 μm) in comparison to investigations with molten ice samples. This is helpful for the detection of element signatures in annual layers of ice cores. The method was applied to the successful determination of traces for the elements Mg, Al, Fe, Zn, Cd, Pb, some rare-earth elements (REE) and minor constituents such as Ca and Na in ice cores. These selected elements serve as tracer elements for certain sources and their element signatures detected in polar ice cores can give hints to climate changes in the past. We report results from measurements of frozen ice samples, the achievable signal intensities, standard deviations and calibration graphs as well as the first signal progression of 208Pb in an 8,000-year-old ice core sample from Greenland. In addition, the first picture of a crater on an ice surface burnt by an IR laser made by cryogenic scanning electron microscopy is presented.  相似文献   

5.
In the present study, a novel analytical approach for the simultaneous determination of 27 brominated flame retardants (BFRs), namely polybrominated diphenyl ethers (PBDEs), isomers of hexabromocyclododecane (HBCD), tetrabromobisphenol A (TBBPA) and several novel BFRs (NBFRs), together with 18 perfluoroalkyl substances (PFASs) in indoor dust was developed and validated. To achieve integrated isolation of analytes from the sample and their fractionation, a miniaturized method based on matrix solid phase dispersion (MSPD) was employed. Principally, after mixing the dust (<0.1 g) with the Florisil®, the mixture was applied on the top of a sorbent (Florisil®) placed in glass column and then analytes were eluted using solvents with different polarities. For the identification/quantification of target compounds largely differing in polarity, complementary techniques represented by gas and liquid chromatography coupled to tandem mass spectrometry (GC–MS/MS and LC–MS/MS) were used. The results of validation experiments, which were performed on the SRM 2585 material (for PBDEs, HBCDs and TBBPA), were in accordance with the certified/reference values. For other analytes (NBFRs and PFASs), the analysis of an artificially contaminated blank dust sample was realized. The method recoveries for all target compounds ranged from 81 to 122% with relative standard deviations lower than 21%. The quantification limits were in the range of 1–25 ng g−1 for BFRs and 0.25–1 ng g−1 for PFASs. Finally, 18 samples (6 households × 3 sampling sites) were analyzed. The high variability between concentrations of PFASs and BFRs in the dust samples from various households as well as collecting sites in a respective house was observed. The total amounts of PFASs and BFRs were in the range of 1.58–236 ng g−1 (median 10.6 ng g−1) and 39.2–2320 ng g−1 (median 325 ng g−1), respectively. It was clearly shown that dust from the indoor environment might be a significant source of human exposure to various organohalogen pollutants.  相似文献   

6.
Electrodeposition is known to be proper for separation and preconcentration of extremely low concentrations of analytes from the bulk sample which is instrumentally very simple. In the present research, a combination of electrodeposition with arc atomic emission spectrometry (ED-AAES) method has been developed in order to improve the analytical performance of this spectrometry technique. The results show that sensitivity and detection limits by using ED-AAES were improved 1000–2000 folds over those of normal arc atomic emission spectrometry in determination of the selected elements. The detection limits for measurement of Ni, Cr and Pb were 2.56, 3.05 and 2.11 µg L− 1 for monodeposition and 3.31, 3.72 and 3.25 µg L− 1 for simultaneously deposition, respectively. The precision of determination was in the range of 2–4% RSD. Typical calibration graphs for these elements were linear up to 100 µg L− 1, depending on the element and matrix.Application of this technique was also tested on determination of the studied elements in an electroplating plant's waste water. The accuracy of technique was verified by comparing the results of the waste water analysis with those of electrothermal atomic absorption spectroscopy as a reference standard method.The obtained results show that the combined technique (ED-AAES) has been progressed substantially toward the ultimate goal of direct interference-free determination of trace analysis in complex samples by AAES.  相似文献   

7.
An electrochemical method based on potentiometric stripping analysis (PSA) employing a hexathia 18C6 (HT18C6) and rice husk (RH) modified carbon paste electrode (HT18C6–RH-CPE) has been proposed for the subnanomolar determination of antimony. The characterization of the electrode surface has been carried out by means of scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy and chronocoulometry. By employing HT18C6–RH-CPE, a 12-fold enhancement in the PSA signal (dt/dE) was observed as compared to plain carbon paste electrode (PCPE). Under the optimized conditions, dt/dE (s V−1) was proportional to the Sb(III) concentration in the range of 1.42 × 10−8 to 6.89 × 10−11 M (r = 0.9944) with the detection limit (S/N = 3) of 2.11 × 10−11 M. The practical analytical utilities of the modified electrode were demonstrated by the determination of antimony in pharmaceutical formulations, human hair, sea water, urine and blood serum samples. The prepared modified electrode showed several advantages, such as simple preparation method, high sensitivity, very low detection limit and excellent reproducibility. Moreover, the results obtained for antimony analysis in commercial and real samples using HT18C6–RH-CPE and those obtained by inductively coupled plasma-atomic emission spectrometry (ICP-AES) are in agreement at the 95% confidence level.  相似文献   

8.
A novel and highly selective method has been developed for the determination of aromatic primary amines by their conversion to dithiocarbamates by reaction with carbon disulphide, and then to isothiocyanates, which are volatile, by heating in the presence of a heavy metal ion. Zinc(II) was selected owing to its low toxicity and optimum yield of isothiocyanates. The latter were sampled by headspace-solid phase microextraction (HS-SPME) on divinylbenzene-carboxen-polydimethylsiloxane fibre, 50/30 μm. The HS-SPME procedure was optimized to provide adequate limits of detection in the analysis of aromatic amines in their real samples by gas chromatography with mass spectrometry (GC–MS) or flame ionization detection (GC–FID). The method gave rectilinear calibration graph, correlation coefficient and limit of detection, respectively, over the range 0.08–100 μg L−1, 0.9950–0.9990 and 25–240 ng L−1 in gas chromatography–mass spectrometry, and 0.01–10 mg L−1, 0.9910–0.9991 and 0.8–3.0 μg L−1 in gas chromatography–flame ionization detection. At two different levels, 10 and 40 μg L−1, the range of intra-day RSD was 3.7–8.5% (GC–MS) and 3.3–9.2% (GC–FID), respectively. The proposed method is simple and rapid, and has been applied to determine aromatic primary amines in the environmental waters, food samples of ice cream powder and soft drinks concentrate, and food colours. The intra-day RSD in the analysis of real samples by GC–MS was in the range 3.6–6.2%. The food/colour samples were found to contain elevated levels of aniline and 2-toluidine.  相似文献   

9.
Carbon nanoparticles (CNPs) and halloysite nanoclay (HNC) modified carbon paste electrode (HNC–CNP–CPE) was developed for the determination of methyl parathion (MP) and ethyl parathion (EP). The electrochemical behavior of these molecules was investigated employing cyclic voltammetry (CV), chronocoulometry (CC), electrochemical impedance spectroscopy (EIS) and potentiometric stripping analysis (PSA). After optimization of analytical conditions employing this electrode at pH 5.0 in acetate buffer (0.1 M), the peak currents were found to vary linearly with its concentration in the range of 1.55 × 10−9 to 3.67 × 10−6 M and 1.21 × 10−9 to 4.92 × 10−6 M for MP and EP, respectively. The detection limits (S/N = 3) of 4.70 × 10−10 M and 3.67 × 10−10 M were obtained for MP and EP, respectively, using PSA. The prepared modified electrode showed several advantages such as simple preparation method, high sensitivity, very low detection limits and excellent reproducibility. The proposed method was employed for the determination of MP and EP in fruits, vegetables, water and soil samples.  相似文献   

10.
A new method for the detection of trace elements in polar ice cores using laser ablation with subsequent inductively coupled plasma mass spectrometry analysis is described. To enable direct analysis of frozen ice samples a special laser ablation chamber was constructed. Direct analysis reduces the risk of contamination. The defined removal of material from the ice surface by means of a laser beam leads to higher spatial resolution (300-1000 microm) in comparison to investigations with molten ice samples. This is helpful for the detection of element signatures in annual layers of ice cores. The method was applied to the successful determination of traces for the elements Mg, Al, Fe, Zn, Cd, Pb, some rare-earth elements (REE) and minor constituents such as Ca and Na in ice cores. These selected elements serve as tracer elements for certain sources and their element signatures detected in polar ice cores can give hints to climate changes in the past. We report results from measurements of frozen ice samples, the achievable signal intensities, standard deviations and calibration graphs as well as the first signal progression of 205Pb in an 8,000-year-old ice core sample from Greenland. In addition, the first picture of a crater on an ice surface burnt by an IR laser made by cryogenic scanning electron microscopy is presented.  相似文献   

11.
This work describes an arsenic speciation analysis in aqueous effluent from a shale industrial plant using liquid chromatography coupled to inductively coupled plasma mass spectrometry (LC–ICP–MS). Arsenic species have been separated through an anion-exchange column and several parameters investigated, such as retention time, pH, flow rate and concentration of the mobile phase (ammonium carbonate), chloride interference and column conditioning time. The best conditions have been found by fixing the pH of the mobile phase at 8.7. Keeping the mobile phase flow rate at 1.5 ml min− 1, arsenic species were separated by varying the concentration of the mobile phase and the time of elution, as follow: 1.5 mmol l− 1 for 10 min, 12 mmol l− 1 for 10 min and 20 mmol l− 1 for 10 min, respectively. Up to 13 As species present in the samples were separated under these conditions and the following species could be identified and quantified: arsenite [As(III)], dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate [As(V)]. The limits of detection of the LC–ICP–MS method were 0.02, 0.06, 0.04 and 0.10 μg l− 1 of As(III), DMA, MMA, and As(V), respectively. The concentration of these species in the samples were from 3.7 to 6.4 μg l− 1, 6.9 to 13.2 μg l− 1, 100 to 142 μg l− 1 and 808 to 1363 μg l− 1 for As(III), DMA, MMA and As(V), respectively. The accuracy, evaluated by recovery tests, varied from 94 to 105% and the precision, evaluated by the relative standard deviation was typically lower than 10%.  相似文献   

12.
A simple, efficient, innovative and environmentally friendly analytical technique was successfully applied for the first time for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) from water samples. The PBDEs selected for this work were those most commonly found in the literature in natural water samples: 2,2′,4,4′-tetraBDE (BDE-47), 2,2′,4,4,5-pentaBDE (BDE-99), 2,2′,4,4,6-pentaBDE (BDE-100) and 2,2,4,4′,5,5′-hexaBDE (BDE-153). The extracted PBDEs were separated and determined by gas chromatography–mass spectrometry (GC–MS). The extraction/preconcentration technique is based on ultrasound-assisted emulsification-microextraction (USAEME) of a water-immiscible solvent in an aqueous medium. Several variables including, solvent type, extraction time, extraction temperature and matrix modifiers were studied and optimized over the relative response the target analytes. Chloroform was used as extraction solvent in the USAEME technique. Under optimum conditions, the target analytes were quantitatively extracted achieving enrichment factors (EF) higher than 319. The detection limits (LODs) of the analytes for the preconcentration of 10 mL sample volume were within the range 1–2 pg mL−1. The relative standard deviations (RSD) for five replicates at 10 pg mL−1 concentration level were <10.3%. The calibration graphs were linear within the concentration range of 5–5000 pg mL−1 for BDE-47 and BDE-100; and 5–10,000 pg mL−1 for BDE-99 and BDE-153, respectively. The coefficients of estimation were ≥0.9985. Validation of the methodology was performed by standard addition method at two concentration levels (10 and 50 pg mL−1). Recovery values were ≥96%, which showed a successful robustness of the analytical methodology for determination of picogram per milliliter of PBDEs in water samples. Significant quantities of PBDEs were not found in the analyzed samples.  相似文献   

13.
This study describes the development of a new analytical method for determining 14 personal care products (PCPs) – nine synthetic musks, four parabens and one insect repellent – in air samples. The method is based on active sampling on sorbent tubes and thermal desorption-gas chromatography–mass spectrometry analysis, and is rapid, sensitive and drastically reduces the risk of sample contamination. Three kinds of tubes and traps were tested, those filled with Tenax TA being the most suitable for this study. Method validation showed good repeatability and reproducibility, low detection limits (between 0.03 ng m−3 for DPMI and 12.5 ng m−3 for propyl paraben) and good linearity for all compounds. Stability during storage indicated that samples must be kept refrigerated at 4 °C and analysed within 1 week of collection. The applicability of the technique to real samples was tested in different indoor and outdoor atmospheres. The total PCP values for indoor air ranged from 135 ng m−3 in a pharmacy to 2838 ng m−3 in a hairdresser's, whereas the values for outdoor air ranged from 14 ng m−3 for a suburban environment to 26 ng m−3 for an urban environment. In general, the most abundant synthetic musks were galaxolide (5.9–1256 ng m−3), musk xylene (1.6–766 ng m−3) and tonalide (1.1–138 ng m−3). Methyl and ethyl paraben (2.4–313 ng m−3 and 1.8–117 ng m−3, respectively) were the most abundant parabens. Although thermal desorption methods have been widely used for determining volatile organic compounds, they are rarely used with semi-volatile compounds. This study thus demonstrates that the thermal desorption method performs well with semi-volatile compounds and, for the first time, that it can be used for determining PCPs.  相似文献   

14.
A method was developed for the quantitative determination of cations and anions in Antarctic ice cores at μg L−1 and sub-μg L−1 levels by ion chromatography (IC), after ultra-clean decontamination procedures. Strict manipulation and decontamination procedures were used in sub-sampling, in order to minimise sample contamination. Na+, NH4+, K+, Mg2+ and Ca2+ were determined by 12-min isocratic elution (H2SO4 eluent). Contemporaneously, in a parallel device, F, MSA (methanesulfonic acid), Cl, NO3 and SO42− were analysed in a single 12-min run with multiple-step elution using Na2CO3/NaHCO3 as eluent. Melted ice samples were pumped from their still-closed containers (polystyrene accuvettes with polyethylene caps), shared between the two ion chromatographic systems, online filtered (0.45 μm Teflon membrane) and pre-concentrated (anions and cations pre-concentration columns) using a flow analysis system, thus avoiding uptake of contaminants from the laboratory atmosphere. Sensitivity, linear range, reproducibility and detection limit were evaluated for each chemical species. Anion or cation detection limits ranged from 0.01 to 0.15 μg L−1 by using a relatively small sample volume (1.5 mL). Such values are significantly lower than those reported in literature for almost all the components. These methods were successfully applied to the analysis of cations and anions at trace levels in the Dome C ice core. The composition of the atmospheric aerosol for the last 850 kyr was reconstructed by high-resolution continuous chemical stratigraphies. Concentration trends in the last nine glacial-interglacial climatic cycles were shown and briefly discussed.  相似文献   

15.
A Flow Injection Analysis (FIA) spectrofluorimetric method for calcium determination in ice cores was optimised in order to achieve better analytical performances which would make it suitable for reliable calcium measurements at ppt level.The method here optimised is based on the formation of a fluorescent compound between Ca and Quin-2 in buffered environment. A careful evaluation of operative parameters (reagent concentration, buffer composition and concentration, pH), influence of interfering species possibly present in real samples and potential favourable effect of surfactant addition was carried out. The obtained detection limit is around 15 ppt, which is one order of magnitude lower than the most sensitive Flow Analysis method for Ca determination currently available in literature and reproducibility is better than 4% for Ca concentrations of 0.2 ppb.The method was validated through measurements performed in parallel with Ion Chromatography on 200 samples from an alpine ice core (Lys Glacier) revealing an excellent fit between the two chemical series. Calcium stratigraphy in Lys ice core was discussed in terms of seasonal pattern and occurrence of Saharan dust events.  相似文献   

16.
In the present work, a cloud point extraction (CPE) system has been proposed for determination of species de chromium in the natural water samples, Cr(III) and Cr(VI). The procedure was based on the reaction of Cr(III) with 1-(2-pyridilazo)-2-naphtol (PAN) in a surfactant solution (Triton X-114) yielding a hydrophobic complex, which then is entrapped “in situ” in the surfactant micelles. When the temperature of the system was higher than the cloud point of Triton X-114, the complex of Cr(III)-PAN entered the surfactant-rich phase and thus separation of the analyte from the matrix was achieved. Separation of the two phases was accomplished by centrifugation for 15 min at 2500 rpm. The Cr(VI) assay is based on its reduction to Cr(III) by ascorbic acid which subsequently reacts with PAN in a similar manner. The main factors affecting the cloud point extraction, such as complexation pH (7.7), buffer concentration (0.025 mol L− 1) and microwave irradiation time (10 min) were optimized by response surface methodology (RSM) using Box–Behnken design. Under the optimized conditions, the preconcentration system (50 mL sample) permitted an enrichment factor of 48, linear range of 2.5–80 μg L− 1, limit of detection and quantification of 0.7 and 2.5 μg L− 1, respectively, and the relative standard deviation (n = 10) of 2.0% for 50 μg L− 1 Cr(III) solution and (n = 10) 5.5% for 10 μg L− 1. The proposed procedure was applied to the speciation of chromium in river water samples. The procedure affords recoveries of 84–115% and a relative standard deviation lower than 4.2%. The analytical results of total chromium in the river water samples under study agreed well with those by electrothermal atomic absorption spectrometry (ET AAS). It is proved that the procedure can be successfully employed as an alternative to the commonly used preconcentration and speciation analytical techniques.  相似文献   

17.
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for quantitative imaging of selected elements (P, S, Fe, Cu, Zn and C) in thin sections of rat brain samples (thickness 20 μm). The sample surface was scanned (raster area ~ 2 cm2) with a focused laser beam (wavelength 266 nm, diameter of laser crater 50 μm, and irradiance 1 × 109 W cm− 2). The laser ablation system was coupled to a double-focusing sector field. The possibility was evaluated of using carbon (via measurement of 13C+) as an internal standard element for imaging element distribution as part of this method. The LA-ICP-MS images obtained for P, S, Fe Cu and Zn were quantified using synthetically prepared matrix-matched laboratory standards. Depending on the sample analyzed, concentrations of Cu and Zn in the control tissue were found to be in the range of 8–10 μg g− 1 and 10–12 μg g− 1, while in the tumor tissue these concentrations were in the range of 12–15 μg g− 1 and 15–17 μg g− 1, respectively. The measurements of P, S and Fe distribution revealed the depletion of these elements in tumor tissue. In all the samples, the shape of the tumor could be clearly distinguished from the surrounding healthy tissue by the depletion in carbon. Additional experiments were performed in order to study the influence of the water content of the analyzed tissue on the intensity signal of the analyte. The results of these measurements show the linear correlation (R2 = 0.9604) between the intensity of analyte and amount of water in the sample. The growth of a brain tumor was thus studied for the first time by imaging mass spectrometry.  相似文献   

18.
High-performance liquid chromatography (HPLC) enantioseparation of terazosin (TER) was accomplished on the immobilised-type Chiralpak IC chiral stationary phase (CSP) under both polar organic and reversed-phase modes. A simple analytical method was validated using a mixture of methanol–water–DEA 95:5:0.1 (v/v/v) as a mobile phase. Under reversed-phase conditions good linearities were obtained over the concentration range 8.76–26.28 μg mL−1 for both enantiomers. The limits of detection and quantification were 10 and 30 ng mL−1, respectively. The intra- and inter-day assay precision was less than 1.66% (RSD%). The optimised conditions also allowed to resolve chiral and achiral impurities from the enantiomers of TER. The proposed HPLC method supports pharmacological studies on the biological effects of the both forms of TER and analytical investigations of potential drug formulations based on a single enantiomer. At the semipreparative scale, 5.3 mg of racemic sample were resolved with elution times less than 12 min using a mobile phase consisting of methanol–DEA 100:0.1 (v/v) and both enantiomers were isolated with a purity of ≥99% enantiomeric excess (ee). The absolute configuration of TER enantiomers was assigned by comparison of the measured specific rotations with those reported in the literature.  相似文献   

19.
An analytical method to determine the total content (i.e., not only in the soluble fraction but also in the particulate one) of eight commonly used UV filters in seawater samples is presented for the first time. Dispersive liquid–liquid microextraction (DLLME) is used as microextraction technique to pre-concentrate the target analytes before their determination by gas chromatography–mass spectrometry (GC–MS). In order to release the UV filters from the suspended particles an ultrasound treatment is performed before DLLME. The ultrasound treatment time was studied in order to achieve a quantitative lixiviation of the target analytes. The type and volume of both disperser and extraction solvent, the sample volume, the pH and the ionic strength involved in the DLLME have been optimized to provide the best enrichment factors. Under the optimized conditions, the method was successfully validated showing good linearity, enrichment factors between 112 and 263 depending on the analyte, limits of detection and quantification in the low ng L−1 range (10–30 ng L−1 and 33–99 ng L−1, respectively) and good intra- and inter-day repeatability (RSD <15%). No significant matrix effects were found. Finally, the method was satisfactorily applied to the analysis of three seawater samples from different origin. Results showed significant amounts of UV filters in the particulate fraction that would have been ignored if only the soluble fraction had been considered. This fact shows that the UV filters are also accumulated in the suspended particles contained in water, what should be taken into account from an environmental standpoint.  相似文献   

20.
A method for the determination of seven perfluorinated carboxylic acids and perfluorooctane sulphonate (PFOS) in aqueous samples using low-cost polymeric sorptive extraction as sample preparation technique, followed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) determination has been developed and validated. Simplicity of the analytical procedure, low volume of solvent and sample required, low global price and a good selectivity providing cleaner extracts are the main advantages of this extraction technique. Polydimethylsiloxane (PDMS) and polyethersulfone (PES) materials were evaluated and compared to achieve the best extraction efficiencies. Hence, different variables have been optimized, viz.: sample pH, concentration of an ion-pairing agent (tetrabutylammonium), ionic strength, sample volume, extraction time, desorption solvent volume, desorption time and the need for auxiliary desorption techniques (sonication). Overall, PES leaded to a better sensitivity than PDMS, particularly for the most polar compounds, reaching detection limits (LODs) in the 0.2–20 ng L−1 range. The precision of the method, expressed as relative standard deviation (RSD), was lower than 16%. Finally, the PES material was employed for the analysis of sea, sewage and fresh water samples. Perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA) and perfluorodecanoic acid (PFDA) were detected in all the analyzed influent samples reaching levels of up to 401 ng L−1. In surface water, perfluorohexanoic acid (PFHxA) exhibited the highest concentrations, up to 137 ng L−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号