首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
Biopharmaceutical production takes place in complex processes which should be thoroughly understood. Therefore, the iConsensus project focuses on developing a monitoring platform integrating several process analytical technology tools for integrated, automated monitoring of the biopharmaceutical process. Water-soluble vitamin monitoring using (microchip) capillary electrophoresis (CE) is part of this platform. This work comprises the development of conventional CE methods as the first part towards integrated vitamin monitoring. The vitamins were divided based on their physical–chemical properties to develop two robust methods. Previously, a method for the analysis of cationic vitamins (pyridoxine, pyridoxal, pyridoxamine, thiamine and nicotinamide) in cell culture medium was developed. This work focused on the development of a micellar electrokinetic chromatography method for anionic and neutral vitamins (riboflavin, d -calcium pantothenate, biotin, folic acid, cyanocobalamin and ascorbic acid). By employing multivariate design of experiments, the background electrolyte (BGE) could be optimised within one experiment testing only 11 BGEs. The optimised BGE conditions were 200 mM borate with 77 mM sodium dodecyl sulphate at a pH of 8.6. Using this BGE, all above-mentioned cationic, anionic and neutral vitamins could be separated in clean samples. In cell culture medium, most anionic and neutral vitamins could be separated. Combining the two methods allows for analysis of cationic, anionic and neutral vitamins in cell culture medium samples. The next step towards integrated vitamin monitoring includes transfer to microchip CE. Due to the lack of fast and reliable methods for vitamin monitoring, the developed capillary methods could be valuable as stand-alone at-line process analytical technology solutions as well.  相似文献   

2.
The rapidly growing, competitive biopharmaceutical market requires tight bioprocess monitoring. An integrated, automated platform for the routine online/at-line monitoring of key factors in the cell culture medium could greatly improve process monitoring. Mono- and disaccharides, as the main energy and carbon source, are one of these key factors. A CE-LIF method was developed for the analysis of several mono- and disaccharides, considering requirements and restrictions for analysis in an integrated, automated monitoring platform, such as the possibility for miniaturization to microchip electrophoresis. Analysis was performed after fluorescent derivatization with 8-aminopyrene-1,3,6-trisulfonic acid. The derivatisation reaction and the separation BGE were optimized using design of experiments. The developed method is applicable to the complex matrix of cell culture medium and proved transferable to microchip electrophoresis.  相似文献   

3.
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the bioanalytical method of choice to support plate‐based, in vitro early ADME (Absorption, Distribution, Metabolism and Excretion) screens such as metabolic stability (Metstab) assessment. MS/MS method optimization has historically been the bottleneck in this environment, where samples from thousands of discrete compounds are analyzed on a monthly basis, mainly due to the lack of a high‐quality commercially available platform to handle the necessary MS/MS method optimization steps for sample analysis by selected reaction monitoring (SRM) on triple quadrupole mass spectrometers. To address this challenge, we recently developed a highly automated bioanalytical platform by successfully integrating QuickQuan? 2.0, a unique high‐throughput solution featuring MS/MS method optimization by automated infusion, with a customized in‐house software tool in support of a Metstab screen. In this platform, a dual‐column setup running parallel chromatography was also implemented to reduce the bioanalytical cycle time for LC/MS/MS sample analysis. A set of 45 validation compounds was used to demonstrate the speed, quality and reproducibility of MS/MS method optimization, sample analysis, and data processing using this automated platform. Metstab results for the validation compounds in microsomes from multiple species (human, rat, mouse) showed good consistency within each batch, and also between batches conducted on different days. We have achieved and maintained a monthly throughput of 1300 compound assays representing 500 discrete compounds per instrument per month on this platform, and it has been used to generate metabolic stability data for more than 25 000 compounds to date with an overall success rate of more than 95%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Protein electrophoresis and immunoblotting are indispensable analytical tools for the characterization of proteins and posttranslational modifications in complex sample matrices. Owing to the lack of automation, commonly employed slab-gel systems suffer from high time demand, significant sample/antibody consumption, and limited reproducibility. To overcome these limitations, we developed a paper-based open microfluidic platform for electrophoretic protein separation and subsequent transfer to protein-binding membranes for immunoprobing. Electrophoresis microstructures were digitally printed into cellulose acetate membranes that provide mechanical stability while maintaining full accessibility of the microstructures for consecutive immunological analysis. As a proof-of-concept, we demonstrate separation of fluorescently labeled marker proteins in a wide molecular weight range (15–120 kDa) within only 15 min, reducing the time demand for the entire workflow (from sample preparation to immunoassay) to approximately one hour. Sample consumption was reduced 10- to 150-fold compared to slab-gel systems, owing to system miniaturization. Moreover, we successfully applied the paper-based approach to complex samples such as crude bacterial cell extracts. We envisage that this platform will find its use in protein analysis workflows for scarce and precious samples, providing a unique opportunity to extract profound immunological information from limited sample amounts in a fast fashion with minimal hands-on time.  相似文献   

5.
《Electrophoresis》2018,39(14):1754-1762
A novel and fully automated sequential injection analysis manifold coupled to a capillary electrophoresis apparatus with amperometric detection, is described. The sequential injection manifold was isolated from the high voltage by inserting an air plug into the circuit. Small buffer reservoirs were used to avoid the need to pump fresh buffer to the interface during the electrophoretic separation. No decoupling device was used to mitigate the interference from the high voltage electric field, instead the potential shift induced by the separation voltage, was accounted for. The new hydrodynamic injection method presented is based on the overpressure created in the circuit when a pinch valve is closed for a predetermined time. The injection method yields RSD values of peak height and area below 2.55 and 1.82%, respectively, at different durations of valve closure (n = 5). The capillary and working electrode alignment was achieved by adapting a commercial available capillary union. When the electrode was replaced, the alignment method proved to be very reliable, yielding RSD values of peak height and area lower than 2.64 and 2.08%, respectively (n = 8). Using this system with a gold microelectrode, dopamine, and epinephrine could be quantified within the concentration range of 1–500 μM and detected at a concentration of 0.3 μM. The methods here presented could be applied for the development of new capillary electrophoresis systems with amperometric detection and/or to the design of fully automated systems for online process monitoring purposes.  相似文献   

6.
For therapeutic drug monitoring in remote settings, dried blood spots (DBS) are particularly advantageous, as blood sample collection and handling is uncomplicated. The aim of this study was to develop and validate an automated extraction method for the analysis of nevirapine, efavirenz and lopinavir in DBS samples. Automated extraction was performed with methanol : water (70 : 30 v /v ), using a DBS‐MS 500 autosampler coupled to a liquid chromatography tandem mass spectrometry system. The autosampler used digital images of each DBS to position the extraction head, sprayed 10 μl of internal standard onto each DBS and extracted a 4‐mm disc (Ø) from the centre of each spot by unilateral flow using 25‐μl extraction solvent. The analytes were baseline separated on a pentafluorophenyl column and analysed by using electrospray ionization with multiple reaction monitoring in positive polarity mode for nevirapine and lopinavir and in negative mode for efavirenz. The method was linear between 10 and 10 000 ng/ml for all analytes. Automated sample extraction resulted in consistent recoveries (nevirapine: 70 ± 6%, efavirenz: 63 ± 11% and lopinavir: 60 ± 10%) and matrix effects between different donors and concentration levels. Intra‐day and inter‐day accuracy and precision deviations were ≤15%. Manual and automated extractions of DBS samples collected within the framework of an adherence assessment study in rural Tanzania showed good agreements with deviations of less than 10%. Our study highlights that therapeutic drug monitoring samples obtained in the resource‐constrained setting of rural Africa can be reliably determined by automated extraction of DBS. Overall, automatization improved method sensitivity and facilitates analysis of large sample numbers. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

7.
Permanent monitoring of waterborne pathogens is important for securing the hygiene of water. Enumerating bacteria in water at low concentrations and minute quantities demands rapid and efficient enrichment methods in order to improve the signal-to-noise ratio of subsequent determination methods. In this work an automated cross-flow microfiltration (CFM) system is presented which is usable in the field to concentrate large volumes of environmental water for analytical purposes. It was designed as a rapid enrichment apparatus achieving high recovery and high concentration factors. The efficiency of the CFM system was studied for E. coli spiked in a 10-L tap water sample. By this technique, a 10-L water sample was concentrated by a factor of 200 in 15 min. The high and consistent recovery of 91.3 ± 5.4% living cells in the concentration range 0.01 and 100 cfu mL−1 is suitable for rapid enumeration of bacteria in water.  相似文献   

8.
In the present study, an ultra-sensitive and highly reproducible novel SERS-based capillary platform was developed and utilized for the trace detection of tetrahydrocannabinol (THC). The approach combines the advantages of microwave-assisted nanoparticle synthesis, plasmonics and capillary forces. By employing a microwave-assisted preparation method, glass capillaries were reproducibly coated with silver nanoparticles in a batch fabrication process that required a processing time of 3 min without needing to use any pre-surface modifications or add surfactants. The coated capillaries exhibited an excellent SERS activity with a high reproducibility and enabled the detection of low concentrations of target molecules. At the same time, only a small amount of analyte and a short and simple incubation process was required. The developed platform was applied to the spectroscopic characterization of tetrahydrocannabinol (THC) and its identification at concentration levels down to 1 nM. Thus, a highly efficient detection system for practical applications, e.g., in drug monitoring/detection, is introduced, which can be fabricated at low cost by using microwave-assisted batch synthesis techniques.  相似文献   

9.
A fully integrated and automated electromembrane extraction LC-MS (EME-LC-MS) system has been developed and characterized. Hyphenation of a flow–flow EME probe to LC-MS was accomplished by using an in-built 10-port switching valve of the LC-MS system. The 10-port switching valve decoupled the high pressure of the UHPLC-system from the low pressure required for operation of the EME-probe by automated switching between a sample extraction/analysis and a sample load position. In the sample load position the extracted analytes were loaded into a HPLC sample loop. By switching the valve to the sample extraction/analysis position the setup allowed simultaneous analysis of previously loaded analytes while extracting a new sample. Performance of the system was characterized with respect to precision and linearity (RSD < 2.5%, R2: 0.998) and the setup was applied for studying the in-vitro metabolism of methadone by rat liver microsomes. As the metabolic reaction proceeded, methadone and its metabolites were extracted and analyzed in parallel by LC-MS using either isocratic or gradient elution. Compared to a conventional in-vitro metabolism analysis based on protein precipitation followed by LC-MS analysis the fully automated EME-LC-MS system offers a significant time saving and in addition demonstrates increased sensitivity as the analytes were automatically enriched during the extraction process. The experiment revealed 6 to 16 times higher S/N ratios of the EME-LC-MS method compared to protein precipitation followed by LC-MS and thus concomitantly lower LOD and LOQ. The setup integrates a complete analytical workflow of rapid extraction, enrichment, separation and detection of analytes in a fully automated manner. These attributes make the developed system a powerful alternative approach for a wide range of analytical applications.  相似文献   

10.
《Electrophoresis》2017,38(13-14):1764-1770
Gel electrophoresis is one of the most applied and standardized tools for separation and analysis of macromolecules and their fragments in academic research and in industry. In this work we present a novel approach for conducting on‐demand electrophoretic separations of DNA molecules in open microfluidic (OM) systems on planar polymer substrates. The approach combines advantages of slab gel, capillary‐ and chip‐based methods offering low consumable costs (<0.1$) circumventing cost‐intensive microfluidic chip fabrication, short process times (5 min per analysis) and high sensitivity (4 ng/μL dsDNA) combined with reasonable resolution (17 bases). The open microfluidic separation system comprises two opposing reservoirs of 2–4 μL in volume, a semi‐contact written gel line acting as separation channel interconnecting the reservoirs and sample injected into the line via non‐contact droplet dispensing and thus enabling the precise control of the injection plug and sample concentration. Evaporation is prevented by covering aqueous structures with PCR‐grade mineral oil while maintaining surface temperature at 15°C. The liquid gel line exhibits a semi‐circular cross section of adaptable width (∼200–600 μm) and height (∼30–80 μm) as well as a typical length of 15–55 mm. Layout of such liquid structures is adaptable on‐demand not requiring time consuming and repetitive fabrication steps. The approach was successfully demonstrated by the separation of a standard label‐free DNA ladder (100–1000 bp) at 100 V/cm via in‐line staining and laser induced fluorescent end‐point detection using an automated prototype.  相似文献   

11.
Portable analytical instrumentation that can provide an alarm indication for the presence of explosives and related components is critical for the identification of explosives-based hazards and threats. Many explosives incident reports involve an inorganic oxidizer-fuel mixture which can include pyrotechnics, fireworks, flash powders, black powders, black powder substitutes, and improvised or homemade explosives. A portable CE instrument with targeted analysis of common inorganic oxidizer ions, for example, chlorate, perchlorate, and nitrate, was used here as a rapid detection platform. Unlike frequently used gas-phase separation and detection instrumentation such as ion mobility spectrometry (IMS), an automated liquid extraction mechanism is required for CE separation using acetate paper sample collection wipes. Target inorganic oxidizers were inkjet-printed onto sample wipes to investigate instrument response relative to the collected analyte spatial distribution. Overall, analyte signal intensities increased with off-center sample deposition due to improved sample extraction from wipes and no change in response was observed for varied array distributions across wipes. The system demonstrated sub 200 ng detection limits for all target analytes, with further improvement when normalizing to an internal standard.  相似文献   

12.
In this paper we report a centrifugal microfluidic “lab-on-a-disc” system for at-line monitoring of human immunoglobulin G (hIgG) in a typical bioprocess environment. The novelty of this device is the combination of a heterogeneous sandwich immunoassay on a serial siphon-enabled microfluidic disc with automated sequential reagent delivery and surface-confined supercritical angle fluorescence (SAF)-based detection. The device, which is compact, easy-to-use and inexpensive, enables rapid detection of hIgG from a bioprocess sample. This was achieved with, an injection moulded SAF lens that was functionalized with aminopropyltriethoxysilane (APTES) using plasma enhanced chemical vapour deposition (PECVD) for the immobilization of protein A, and a hybrid integration with a microfluidic disc substrate. Advanced flow control, including the time-sequenced release of on-board liquid reagents, was implemented by serial siphoning with ancillary capillary stops. The concentration of surfactant in each assay reagent was optimized to ensure proper functioning of the siphon-based flow control. The entire automated microfluidic assay process is completed in less than 30 min. The developed prototype system was used to accurately measure industrial bioprocess samples that contained 10 mg mL−1 of hIgG.  相似文献   

13.
Liquid extraction surface analysis (LESA) has an advantage of directly sampling analytes on a surface, thus avoiding unnecessary dilution by homogenization of the bulk sample commonly practiced in solid sample analysis. By combining LESA with CE, the additional advantage of separating analytes before detection can be accomplished. For neutral molecules, MEKC needs to be used. Since the detection sensitivity of CE in general suffers from the small capillary dimension, analyte focusing by micelle collapse was employed for enhanced extraction in LESA and sample preconcentration for MEKC. In addition, using a commercial CE instrument, the LESA process was performed much faster and more reliably compared to our first demonstration of LESA‐CE using a homemade CE setup. Three neutral water‐insoluble pesticides sprayed on an apple skin were directly extracted, preconcentrated, and analyzed by the automated LESA‐analyte focusing by micelle collapse‐MEKC with high sensitivity in 10 min. The relative standard deviations of the migration times and peak heights were 0.8–2.1 and 1.2–3.0%, respectively when ametryn was used as an internal standard. The limits of detection obtained with UV absorbance at 200 nm were 1.8–6.4 ppb.  相似文献   

14.
Paliperidone is a new antipsychotic drug with a relatively low therapeutic concentration of 20–60 ng/mL. We established an accurate and sensitive CE method for the determination of paliperidone concentrations in human plasma in this study. To minimize matrix effect caused by quantification errors, paliperidone was extracted from human plasma using Oasis HLB SPE cartridges with three‐step washing procedure. To achieve sensitive quantification of paliperidone in human plasma, a high‐conductivity sample solution with sweeping‐MEKC method was applied for analysis. The separation is performed in a BGE composed of 75 mM phosphoric acid, 100 mM SDS, 12% acetonitrile, and 15% tetrahydrofuran. Sample solution consisted of 10% methanol in 250 mM phosphoric acid and the conductivity ratio between sample matrix and BGE was 2.0 (γ, sample/BGE). The results showed it able to detect paliperidone in plasma samples at concentration as low as 10 ng/mL (S/N = 3) with a linear range between 20 and 200 ng/mL. Compared to the conventional MEKC method, the sensitivity enhancement factor of the developed sweeping‐MEKC method was 100. Intra‐ and interday precision of peak area ratios were less than 6.03%; the method accuracy was between 93.4 and 97.9%. This method was successfully applied to the analysis of plasma samples of patients undergoing paliperidone treatment.  相似文献   

15.
A low-volume automated injection system for the analysis of chemically complex, amino acid samples is presented. This system utilizes submicroliter sample volumes stored on a 75-μm inner diameter capillary. A pulse of positive pressure (82 kPa) is used to load nanoliter sample volumes into an in-house fabricated interface and onto a separation capillary. Residual sample solution in the interface is immediately washed away by a continuous transverse flow through the injection interface, yielding a sharp and reproducible sample plug. By performing multiple injections of a static sample, one may average the signals to yield a signal-to-noise ratio improvement of up to 4.07-fold for 20 injections compared with a theoretical maximum of a 4.47-fold improvement. Without interruption of the applied voltage, injections performed every 150 s were used to monitor the progress of the reaction of multiple amino acids with the fluorogenic dye 3-(4-carboxybenzoyl)quinoline-2-carboxaldehyde. Analysis of dialyzed clinical vitreous samples demonstrates the resolution and quantitation of arginine, lysine, leucine, glutamine, and glutamate. Observed levels are comparable with those of nonautomated injection methods and reports by others. Figure Multiple injections of fluorescently labeled human vitreous with a detailed view of a single injection (above) and with all injections segmented and averaged for signal-to-noise ratio improvement (right)  相似文献   

16.
Most real samples cannot directly be infused to mass spectrometers because they could contaminate delicate parts of ion source and guides, or cause ion suppression. Conventional sample preparation procedures limit temporal resolution of analysis. We have developed an automated liquid–liquid extraction system that enables unsupervised repetitive treatment of dynamic samples and instantaneous analysis by mass spectrometry (MS). It incorporates inexpensive open-source microcontroller boards (Arduino and Netduino) to guide the extraction and analysis process. Duration of every extraction cycle is 17 min. The system enables monitoring of dynamic processes over many hours. The extracts are automatically transferred to the ion source incorporating a Venturi pump. Operation of the device has been characterized (repeatability, RSD = 15%, n = 20; concentration range for ibuprofen, 0.053–2.000 mM; LOD for ibuprofen, ∼0.005 mM; including extraction and detection). To exemplify its usefulness in real-world applications, we implemented this device in chemical profiling of pharmaceutical formulation dissolution process. Temporal dissolution profiles of commercial ibuprofen and acetaminophen tablets were recorded during 10 h. The extraction-MS datasets were fitted with exponential functions to characterize the rates of release of the main and auxiliary ingredients (e.g. ibuprofen, k = 0.43 ± 0.01 h−1). The electronic control unit of this system interacts with the operator via touch screen, internet, voice, and short text messages sent to the mobile phone, which is helpful when launching long-term (e.g. overnight) measurements. Due to these interactive features, the platform brings the concept of the Internet-of-Things (IoT) to the chemistry laboratory environment.  相似文献   

17.
Monoclonal antibodies (mAbs) have become an important class of biopharmaceuticals used for the treatment of various diseases. Their quantification during the manufacturing process is important. In this work, a capillary zone electrophoresis (CZE) method was developed for the monitoring of the mAb concentration during cell-culture processes. CZE method development rules are outlined, particularly discussing various capillary coatings, such as a neutral covalent polyvinyl alcohol coating, a dynamic successive multiple ionic-polymer coating, and dynamic coatings using background electrolyte additives such as triethanolamine (T-EthA) and triethylamine. The dynamic T-EthA coating resulted in most stable electro-osmotic flows and most efficient peak shapes. The method is validated over the range 0.1–10 mg/ml, with a linear range of 0.08–1.3 mg/ml and an extended range of 1–10 mg/ml by diluting samples in the latter concentration range 10-fold in water. The intraday precision and accuracy were 2%–12% and 88%–107%, respectively, and inter-day precision and accuracy were 4%–9% and 93%–104%, respectively. The precision and accuracy of the lowest concentration level (0.08 mg/ml) were slightly worse and still well in scope for monitoring purposes. The presented method proved applicable for analysing in-process cell-culture samples from different cell-culture processes and is possibly well suited as platform method.  相似文献   

18.
A rapid microfluidic based capillary electrophoresis immunoassay (CEIA) was developed for on-line monitoring of glucagon secretion from pancreatic islets of Langerhans. In the device, a cell chamber containing living islets was perfused with buffers containing either high or low glucose concentration. Perfusate was continuously sampled by electroosmosis through a separate channel on the chip. The perfusate was mixed on-line with fluorescein isothiocyanate-labeled glucagon (FITC-glucagon) and monoclonal anti-glucagon antibody. To minimize sample dilution, the on-chip mixing ratio of sampled perfusate to reagents was maximized by allowing reagents to only be added by diffusion. Every 6 s, the reaction mixture was injected onto a 1.5-cm separation channel where free FITC-glucagon and the FITC-glucagon–antibody complex were separated under an electric field of 700 V cm−1. The immunoassay had a detection limit of 1 nM. Groups of islets were quantitatively monitored for changes in glucagon secretion as the glucose concentration was decreased from 15 to 1 mM in the perfusate revealing a pulse of glucagon secretion during a step change. The highly automated system should be enable studies of the regulation of glucagon and its potential role in diabetes and obesity. The method also further demonstrates the potential of rapid CEIA on microfluidic systems for monitoring cellular function.  相似文献   

19.
Summary In chemical and pharmaceutical production plants process control is often performed by plant personal near the process (at-line). Alternatively, spectroscopic procedures like near infrared may be coupled to the process using in-line or on-line interfaces. When the analytical problem cannot be solved by these established approaches chromatographic techniques can be directly coupled to the production process. An application of chemical reaction monitoring which is difficult to perform is reported. The analytical problems are solved by HPLC and CE. Both techniques in the application presented need an on-line derivatization step prior to the analysis. Flow Injection Analysis (FIA) was applied for this sample preparation step. For the online coupling to the commercially available CE-instrument a special sample vial was developed. The application shows sufficient reproducibility and analysis speed for near real-time monitoring. of the process. Dedicated to Professor Dr. Heinz Engelhardt on the occasion of his 65th birthday.  相似文献   

20.
We present the design and characterization of a low cost, thread-based electrophoretic device with integrated electrochemical detection. The device has an end-channel pencil graphite electrode placement system for performing electrochemical detection on the thread electrophoresis platform with direct sample pipetting onto the thread. We also established the use of methylene blue and neutral red as a pair of reference migration markers for separation techniques coupled with electrochemical detection, as they have different colors for visual analysis and are both electroactive. Importantly, neutral red was also found to migrate at a similar rate to the EOF, indicating that it can be used as a visual identifier of EOF. The utility of our system was demonstrated by electrophoretic separation and electrochemical detection of physiologically relevant concentrations of pyocyanin in a solution containing multiple electroactive compounds. Pyocyanin is a biomarker for the detection of pathogenic Pseudomonas aeruginosa and has a redox potential that is similar to that of methylene blue. The system was able to effectively resolve methylene blue, neutral red, and pyocyanin in less than 7 min of electrophoretic separation. The theoretical limit of detection for pyocyanin was determined to be 559 nM. The electrophoretic mobilities of methylene blue (0.0236 ± 0.0007 mm2/V·s), neutral red (0.0149 ± 0.0007 mm2/V·s), and pyocyanin (0.0107 ± 0.0003 mm2/V·s) were also determined.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号