首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper reports on the optimisation, characterisation, validation and applicability of gas chromatography coupled to triple quadrupole mass spectrometry in its tandem operation mode (GC-QqQ(MS/MS) for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs, dioxins) and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food matrices. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for the analysis of this type of compounds and samples. Good repeatability for areas (RSD = 1–10%, for PCDD/Fs and DL-PCBs) and for ion transition ratios (RSD = 0.3–10%, for PCDD/Fs, and 0.2–15%, for DL-PCBs) and low instrumental limits of detection, 0.07–0.75 pg μL−1 (for dioxins) and 0.05–0.63 pg μL−1 (for DL-PCBs), were obtained. A comparative study of the congener specific determination using both GC-QqQ(MS/MS) and gas chromatography-high resolution mass spectrometry (GC-HRMS) was also performed by analysing several fortified samples and certified reference materials (CRMs) with low (feed and foodstuffs), median (sewage sludge) and high (fly ash) toxic equivalency (TEQ) concentration levels, i.e. 0.60, 1.83, 72.9 and 3609 pg WHO-TEQ(PCDD/Fs) g−1. The agreement between the results obtained for the total TEQs (dioxins) on GC-QqQ(MS/MS) and GC-HRMS in all the investigated samples were within the range of ±4%, and that of DL-PCBs at concentration levels of 0.84 pg WHO-TEQs (DL-PCBs) g−1, in the case of feedstuffs, was 0.11%. Both instrumental methods have similar and comparable linearity, precision and accuracy. The GC-QqQ(MS/MS) sensitivity, lower than that of GC-HRMS, is good enough (iLODs in the down to low pg levels) to detect the normal concentrations of these compounds in food and environmental samples. These results make GC-QqQ(MS/MS) suitable for the quantitative analysis of dioxins and DL-PCBs and a real alternative tool to the reference sector HRMS instruments.  相似文献   

2.
A sensitive method based on programmable temperature vaporization large volume injection coupled to gas chromatogram and high-resolution mass spectrometry (PTV-GC–HRMS) has been developed for the determination of ultra trace levels of dioxin-like polychlorinated biphenyls (DL PCBs) in small amounts of human blood. Blood samples (1 mL) were first extracted by column extraction and then purified with column chromatorgraphies. Final extracts (20 μL) were introduced to the PTV injector under the solvent vent mode and detected by GC–HRMS (SIM mode). PTV parameters were observed by changing one factor at a time (practical conditions: vent flow: 50 mL min−1, vent pressure: 0 kPa and vent time: 0.1 min), recoveries of most PCB congeners ranged from 55.1% to 108%, and method detection limits were in the range of 0.11–1.63 pg g−1.  相似文献   

3.
Zhang Z  Rhind SM 《Talanta》2011,84(2):487-493
We describe a solid-phase extraction (SPE) method, followed by gas chromatography-mass spectrometry (GC-MS), for the simultaneous determination of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in sheep serum samples. The denaturation of serum proteins by formic acid, water-1-propanol and water-2-propanol were compared and optimized. Seven different solid-phase sorbents were tested and it was found that Strata-X cartridge (200 mg, 6 mL) gave the best recoveries (92-106%, SD < 6%, n = 3) for all the target analytes. The different extraction solvents (iso-hexane and dichloromethane), either alone or in combination, were used to extract these persistent organic compounds from spiked serum samples by SPE. Removal of co-extracted biogenic materials was achieved using adsorption chromatography with acid modified silica and activated silica. Iso-hexane was found to be the most appropriate solvent for clean-up providing good recoveries and clear chromatographic separation; its use is preferable to that of DCM because it is less environmentally toxic. The limits of detection (LOD) of the proposed method were 47-105 pg g−1 and 16-24 pg g−1 for the different PBDEs and PCBs studied, respectively. The developed method was linear over the range from 0.05 to 30 ng g−1, for all PBDEs except PBDE 183 (0.10-30 ng g−1), and from 0.02 to 30 ng g−1 for all tested PCB congeners. The established method was successfully applied to sheep serum samples from Scotland, UK, for the determination of the target PBDEs and PCBs.  相似文献   

4.
Hydroxylated polychlorinated biphenyls (OH-PCBs) have been shown to be strongly retained in human blood causing endocrine-related toxicity, particularly on the thyroid system. Traditionally, analytical methods for the determination of OH-PCBs require labor-intensive and long-time consuming sample preparation with several extraction, evaporation and cleanup procedures steps and, in some cases, derivatization prior to the analysis by gas or liquid chromatography-mass spectrometry (GC–MS or LC-MS). The present study developed and validated a novel, sensitive and high throughput online solid phase extraction (SPE) method coupled to LC-tandem mass spectrometry (MS/MS) for the separation and quantitation of relevant congeners of OH-PCBs in human plasma. The developed method presented limits of quantification (LOQ) ranging from 0.02 to 0.5 ng mL−1 and extraction recoveries from 71 to 134% for all congeners, requiring small amount of sample (only 100 μL) and minimal sample preparation. In order to evaluate the applicability of the method, preliminary tests (N = 93) were conducted in plasma from individuals occupationally exposed to very high levels of PCBs in a German cohort. Penta-through hepta-chlorinated OH-PCBs were the predominant congeners in human plasma with concentrations up to 44.5 ng mL−1, while lower chlorinated OH-PCBs were occasionally detected. In addition, a new PCB 28 metabolite has been synthesized and identified for the first time in human plasma and associations between OH-PCBs and their parent compounds in the studied cohort were also assessed.  相似文献   

5.
Ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in 10 mL of water samples by gas chromatography-mass-selective detection. After determination of the most suitable solvent and extraction time, several other parameters including solvent volume, centrifugation time and ionic strength of the sample were optimized using a 23 factorial experimental design. The optimized USAEME procedure used 200 μL of chloroform as extraction solvent, 10 min of extraction with no ionic strength adjustment at 25 °C and 5 min of centrifugation at 4000 rpm. The limits of detection ranged from 14 ng L−1 (for PCB153) to 30 ng L−1 (for PCB101). Recoveries of PCBs from fortified distilled water are over 80% for three different fortification levels between 0.1 and 5 μg L−1 and relative standard deviations of the recoveries are below 10%. The performance of the proposed method was compared with those involving traditional liquid-liquid extraction (LLE) and solid phase extraction (SPE) on the real water samples (i.e., tap and well water as well as domestic and industrial wastewaters, etc.) and comparable efficiencies were obtained. The proposed USAEME procedure has been demonstrated to be viable, simple, rapid and easy to use for residue analysis of PCBs in water samples.  相似文献   

6.
The adsorptive potential of hexagonal boron nitride nanosheets (h-BNNSs) for solid-phase extraction (SPE) of pollutants was investigated for the first time. Seven indicators of polychlorinated biphenyls (PCBs) were selected as target analytes. The adsorption of PCBs on the surface of the h-BNNSs in water was simulated by the density functional theory and molecular dynamics. The simulation results indicated that the PCBs are adsorbed on the surface by π–π, hydrophobic, and electrostatic interactions. The PCBs were extracted with an h-BNNS-packed SPE cartridge, and eluted by dichloromethane. Gas chromatography–tandem mass spectrometry working in the multiple reaction monitor mode was used for the sample quantification. The effect of extraction parameters, including the flow rate, pH value, breakthrough volume, and the ionic strength, were investigated. Under the optimal working conditions, the developed method showed low limits of detection (0.24–0.50 ng L−1; signal-to-noise ratio = 3:1), low limits of quantification (0.79–1.56 ng L−1; signal-to-noise ratio = 10:1), satisfactory linearity (r > 0.99) within the concentration range of 2–1000 ng L−1, and good precision (relative standard deviation < 12%). The PCBs concentration in environmental water samples was determined by the developed method. This results demonstrate that h-BNNSs have high analytical potential in the enrichment of pollutants.  相似文献   

7.
The aim of this study was developing a supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS) method and an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method, for the analysis of N-acetyl-serotonin (NAS) and melatonin (Mel) in human serum, and to compare the performance of these methods. Deuterated isotopologues of the neurotransmitters were synthesized and evaluated for suitability as internal standards in sample preparation. Liquid-liquid extraction was selected as sample preparation procedure. With chloroform, the best extraction solvent tested, an extraction yield of 48 ± 2% for N-acetyl-serotonin and 101 ± 10% for melatonin was achieved. SFC separation was accomplished within 3 min on a BEH stationary phase, employing isocratic elution with 90% carbon dioxide and 0.1% formic acid as well as 0.05% ammonium formate in methanol. For the 4 min UHPLC gradient separation with 0.1% formic acid in water and methanol, respectively, a Kinetex XB-C18 was used as stationary phase. Both chromatographic techniques were optimized regarding mobile phase composition, additives to the mobile phase and column temperature. Multiple reaction monitoring (MRM) analysis was used for quantification of the metabolites. Both methods were validated regarding retention time stability, LOD, LOQ, repeatability and reproducibility of quantification, process efficiency, extraction recovery and matrix effects. LOD and LOQ were 0.017 and 0.05 pg μL−1 for NAS and 0.006 and 0.018 pg μL−1 for Mel in SFC-MS/MS compared to 0.028 and 0.1 pg μL−1 for NAS and 0.006 and 0.017 pg μL−1 for Mel in UHPLC-MS/MS.  相似文献   

8.
The gas chromatographic–mass spectrometric (GC–MS) separation of all 209 polychlorinated biphenyl (PCB) congeners was studied on an extremely efficient 80 m × 0.1 mm i.d. capillary column coated with a 0.1 μm film of poly(5%-phenyl methyl)siloxane stationary phase. The quality of the separation and the number of resolved and coeluting peaks were compared to predictions according to the statistical overlap theory (SOT) and to literature data on PCB separations obtained by one-dimensional and comprehensive two-dimensional GC (GC × GC) and GC–MS. Mass spectral and chemometric deconvolution procedures were used to resolve overlapping peaks. On the highly efficient column, 195 PCB congeners were resolved in 96 min separation time using spectral and chemometric deconvolution. This number is comparable to the best separations described in GC × GC–MS mode. The novel method was developed for spectral deconvolution of overlapped PCB congeners which was verified determining the most toxic, dioxin-like PCBs both in the model mixture of 209 PCBs as well as in the Aroclor 1242 and Aroclor 1254 formulations.  相似文献   

9.
Phthalates (PAEs) are ubiquitous toxic chemical compounds. During the last few years, some phthalate metabolites (MPAEs) have been proposed as appropriate biomarkers in human urine samples to determine PAE human intake and exposure. So, it is necessary to have fast, easy, robust and validated analytical methods to determine selected MPAEs in urine human samples. Two different instrumental methods based on gas (GC) and ultra-high performance liquid (UHPLC) chromatography coupled to mass spectrometry (MS) have been optimized, characterized and validated for the simultaneous determination of nine primary and secondary phthalate metabolites in urine samples. Both instrumental methods have similar sensitivity (detection limits ranged from 0.03 to 8.89 pg μL−1 and from 0.06 to 0.49 pg μL−1 in GC–MS and UHPLC–MS2, respectively), precision (repeatability, expressed as relative standard deviation, which was lower than 8.4% in both systems, except for 5OH-MEHP in the case of GC–MS) and accuracy. But some advantages of the UHPLC–MS2 method, such as more selectivity and lower time in the chromatographic runs (6.8 min vs. 28.5 min), have caused the UHPLC–MS2 method to be chosen to analyze the twenty one human urine samples from the general Spanish population. Regarding these samples, MEP showed the highest median concentration (68.6 μg L−1), followed by MiBP (23.3 μg L−1), 5cx-MEPP (22.5 μg L−1) and MBP (19.3 μg L−1). MMP (6.99 μg L−1), 5oxo-MEHP (6.15 μg L−1), 5OH-MEHP (5.30 μg L−1) and MEHP (4.40 μg L−1) showed intermediate levels. Finally, the lowest levels were found for MBzP (2.55 μg L−1). These data are within the same order of magnitude as those found in other similar populations.  相似文献   

10.
Polychlorinated naphthalenes (PCNs) are candidates for inclusion in the Stockholm Convention on persistent organic pollutants. PCNs are structurally and toxicologically similar to 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) and its analogues. Intake in food is considered to be an important human exposure pathway for PCNs. In this preliminary study, cheese and butter samples were analysed for PCNs, polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) using an isotope dilution gas chromatography high-resolution mass spectrometry method. The aim of this study was to evaluate the PCN concentrations in the cheese and butter samples and to compare them with the PCDD, PCDF and PCB concentrations. The PCN concentrations were 5.6–103 pg g?1 of wet weight in the seven cheese samples tested and 5.0–199 pg g?1 of wet weight in the seven butter samples tested. The mass concentrations of lower chlorinated congeners were greater than those of the higher chlorinated congeners. Congeners of CN45/36, CN27/30 and CN33/34/37 were much more abundant than other congeners found in tetrachlorinated PCNs. Congeners of CN51, CN66/67 and CN73 were determined to be the predominant congeners in penta-, hexa- and heptachlorinated homologs, respectively. The PCNs contributed around 5% of the total PCN, PCDD, PCDF and PCB toxic equivalence (TEQ) values. CN73 was found to be the dominant PCN congener and contributed more than 40% to the PCN TEQ value. Congeners CN66/67, CN69 and CN63 were also found at relatively high levels. The PCB congener CB118 was the predominant congener (by mass-based concentration) of the 12 dioxin-like PCBs (dl-PCBs). The PCBs contributed 53.8% of the total TEQ, and congener CB126 contributed more than any other compound that was analysed to the total TEQ. The PCDDs and PCDFs contributed 11.6% and 29.7% of the total TEQ values, respectively.  相似文献   

11.
Miniaturised ultrasonic solvent extraction procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in soil samples by gas chromatography-mass-selective detection by using 23 factorial experimental design. Recoveries of PCBs from fortified soil samples are over 90% for three different fortification levels between 40 and 120 μg kg−1, and relative standard deviations of the recoveries are below 7%. The limits of detection (LODs) ranged from 0.003 to 0.006 μg kg−1. The performance of the proposed method was compared to traditional shake flask extraction method on the spiked real soil sample and extraction methods showed comparable efficiencies. Proposed miniaturised ultrasonic solvent extraction offers several advantages, i.e., reducing sample requirement for measurement of target compound, less solvent consumption and reducing the costs associated with solvent purchase and waste disposal.  相似文献   

12.
A simple, rapid, and highly sensitive bioelectrochemical immunoassay method based on magnetic beads (MBs) and disposable screen-printed electrodes (SPE) has been developed to detect polychlorinated biphenyls (PCBs). The principle of this bioassay is based on a direct competitive enzyme-linked immunosorbent assay using PCB-antibody-coated MBs and horseradish peroxidase (HRP)-labeled PCB (HRP-PCB). A magnetic process platform was used to mix and shake the samples during the immunoreactions and to separate free and unbound reagents after the liquid-phase competitive immunoreactions among PCB-antibody-coated MBs, PCB analyte, and HRP-PCB. After a complete immunoassay, the HRP tracers attached to MBs were transferred to a substrate solution containing o-aminophenol and hydrogen peroxide for electrochemical detection. The different parameters, including the amount of HRP-PCB conjugates, immunoreaction time, and the concentration of substrate that governs the analytical performance of the immunoassay have been studied in detail and optimized. The detection limit of 10 pg mL−1 was obtained under optimum experimental conditions. The performance of this bioelectrochemical immunoassay was successfully evaluated with untreated river water spiked with PCBs, and the results were validated by commercial PCB enzyme-linked immunosorbent assay kit, indicating that this convenient and sensitive technique offers great promise for decentralized environmental application and trace PCBs monitoring.  相似文献   

13.
An efficient analytical method for simultaneous determination of 12 SFEs in serum is described. The method involves solid-phase extraction to isolate of SFEs from interfering species, especially cholesteryl esters, conversion to trimethylsilyl (TMS) ether derivatives for the direct analysis by gas chromatography–mass spectrometry (GC–MS) using a high temperature MXT-1 (Silcosteel-treated stainless steel) capillary column. All SFEs as their TMS derivatives were well separated with excellent peak shapes within 12 min. Overall recoveries ranged from 88% to 119%, with a detection limits for SFEs ranged from 2 to 30 μg L−1. The linearity as correlation coefficient was higher than 0.99 except for pregnenolone-3-arachidate (r2 = 0.98) in the concentration range of 5–3000 μg L−1. Ten serum samples obtained from volunteers were also analyzed and quantitatively determined of DHEA-3-palmitate and pregnenolone-3-stearate in 1.8–1195.8 μg L−1 concentration. The devised high temperature GC–MS method could be useful for identification of SFEs in biological specimens including serum.  相似文献   

14.
Polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) are hazardous food contaminants, their maximum legally allowable levels in food and environment are in the low pg g−1 range. Therefore some highly selective and sensitive analytical methods must be used to determine them. The 96/23/EC Directive implemented by EC Decision of 12 August 2002 requires recovery rate of an analyte at a concentration below 1 ng g−1 within the 50–120% range at relative standard deviation (RSD) as low as possible.  相似文献   

15.
Di-(2-ethyl-hexyl)phthalate (DEHP), nonylphenol, nonylphenol mono- and diethoxylates (NPEs) and polychlorinated biphenyls (PCBs) are organic pollutants in sewage sludge which have to be monitored in the European Union according to a future Sludge Directive. In the present work, an analytical method for the simultaneous extraction and determination of DEHP, NPEs and PCBs is proposed for the routine analysis of these compounds in sludge from wastewater treatment plants. All the compounds were simultaneously extracted by sonication with hexane and analysed by gas chromatography-mass spectrometry (GC-MS) in electronic impact mode. Recoveries achieved were 105% for DEHP, 61.4-88.6% for NPEs and 55.8-108.3% for PCBs with relative standard deviation bellow 10%. Limits of quantification were 65 μg kg−1 for DEHP, from 630 to 2504 μg kg−1 for NPEs and from 5.4 to 10.6 μg kg−1 for PCBs in dried sludge. The applicability of the proposed method was evaluated by the determination of these compounds in sludge from wastewater treatment plants in Seville (South Spain).  相似文献   

16.
Qiang Fu  Qiuquan Wang 《Talanta》2007,72(4):1248-1254
A newly synthesized alkyl phosphinic acid resin (APAR) was used for on-line preconcentration of trace rare earth elements (REES, lanthanides including yttrium) and then determined by inductively coupled plasma mass spectrometry. REEs in seawater could be on-line concentrated on the APAR packed column (4.6 mm i.d. × 50 mm in length), and eluted from the column with 0.5 mL 0.1 mol L−1 nitric acid within 30 s. An enrichment factor of nearly 400 was achieved for all REEs when the seawater sample volume was 200 mL, while the matrix and coexisting spectrally interfering ions such as barium, tin and antimony could be simultaneously separated. The detection limits of this proposed method for REEs were in the range from 1.43 pg L−1 of holmium to 12.7 pg L−1 of lanthanum. The recoveries of REEs were higher than 97.9%, and the precision of the relative standard deviation (R.S.D., n = 6) was less than 5%. The method has been applied to the determination of soluble REEs in seawater.  相似文献   

17.
The design and testing of a new and low-cost experimental setup used for vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) is reported here. The device consists of a specially designed O-ring seal screw cap offering gas-tight seal to commercially available headspace vials. The new polytetrafluoroethylene (PTFE) cap was molded by a local manufacturer and had a hole that could tightly accommodate a septum. All operations were performed through the septum: air evacuation of the sampler, sample introduction and HSSPME sampling. The analytical performance of the new sampler was evaluated using 22 mL headspace vials with 9 mL water samples spiked with polychlorinated biphenyls (PCBs). Several experimental parameters were controlled and the optimized conditions were: 1000 rpm agitation speed; 30 min extraction time; 40 °C sampling temperature; polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber. The lack of accurate Henry's law constant (KH) values and information regarding how they change with temperature was a major limitation in predicting the phase location of evaporation resistance during Vac-HSSPME. Nevertheless, the combined effects of system conditions indicated the increasing importance of gas phase resistance with increasing degree of PCBs chlorination. Stirring enhancements were not recorded for the higher chlorinated PCBs suggesting that the hyperhydrophobic gas/water interface was the preferred location for these compounds. Analytically, the developed method was found to yield linear calibration curves with limits of detection in the sub ng L−1 level and relative standard deviations ranging between 5.8 and 14%. To compensate for the low recoveries of the higher chlorinated PCB congeners in spiked river water the standard addition methodology was applied. Overall, the compact design of the new and reusable sample container allows efficient HSSPME sampling of organic analytes in water within short extraction times and at low sampling temperatures compared to other published HSSPME methods.  相似文献   

18.
An organically modified silicate (ORMOSIL) SPME stationary phase molecularly imprinted with BDE-209 has been successfully fabricated by conventional sol-gel technique from phenyltrimethoxysilane and tetraethoxysilane. The thickness of the ORMOSIL-SPME stationary phase, on fused-silica optical fibres, was measured to be ca. 9.5 μm with a volume of ca. 0.12 μL. Rebinding assays and Scatchard analysis revealed that the imprinted ORMOSIL-SPME stationary phase possessed a binding affinity, KB, of 7.3 ± 1.7 × 1010 M−1 for BDE-209, with a receptor site density, Bmax, of 1.2 × 10−3 pmol per SPME device. Besides its molecular template, the ORMOSIL-SPME stationary phase also showed good affinity (log KB ≥ 9.5) for smaller BDE congeners commonly found in the natural environment. The density of receptor sites within the imprinted matrix for those smaller BDE congeners was even higher than that for BDE-209. This may be attributable to the binding site heterogeneity of the imprinting process that creates deformed binding sites that are suitable for the accommodation of the smaller BDE congeners. Compared to the commercially available polyacrylate and polydimethylsiloxane SPME stationary phases, the imprinted ORMOSIL-SPME devices showed much higher pre-concentration ability towards polybrominated diphenyl ethers (PBDEs), even in direct immersion sampling at room temperature. Coupled with GC-NCI-MS and GC-μECD, the imprinted ORMOSIL-SPME device was able to achieve detection sensitivity of 0.2-3.6 pg mL−1 and 1-8.8 pg mL−1, respectively, for commonly occurring BDE congeners, including medium to high molecular weight PBDEs. The imprinted ORMOSIL-SPME device has been successfully applied to monitor PBDE contents in municipal wastewaters.  相似文献   

19.
A novel and highly selective method has been developed for the determination of aromatic primary amines by their conversion to dithiocarbamates by reaction with carbon disulphide, and then to isothiocyanates, which are volatile, by heating in the presence of a heavy metal ion. Zinc(II) was selected owing to its low toxicity and optimum yield of isothiocyanates. The latter were sampled by headspace-solid phase microextraction (HS-SPME) on divinylbenzene-carboxen-polydimethylsiloxane fibre, 50/30 μm. The HS-SPME procedure was optimized to provide adequate limits of detection in the analysis of aromatic amines in their real samples by gas chromatography with mass spectrometry (GC–MS) or flame ionization detection (GC–FID). The method gave rectilinear calibration graph, correlation coefficient and limit of detection, respectively, over the range 0.08–100 μg L−1, 0.9950–0.9990 and 25–240 ng L−1 in gas chromatography–mass spectrometry, and 0.01–10 mg L−1, 0.9910–0.9991 and 0.8–3.0 μg L−1 in gas chromatography–flame ionization detection. At two different levels, 10 and 40 μg L−1, the range of intra-day RSD was 3.7–8.5% (GC–MS) and 3.3–9.2% (GC–FID), respectively. The proposed method is simple and rapid, and has been applied to determine aromatic primary amines in the environmental waters, food samples of ice cream powder and soft drinks concentrate, and food colours. The intra-day RSD in the analysis of real samples by GC–MS was in the range 3.6–6.2%. The food/colour samples were found to contain elevated levels of aniline and 2-toluidine.  相似文献   

20.
Persistent organic pollutants remain a serious threat to many food-chain systems. New pollutants continue to emerge. The present study has created novel extraction vessels which are compatible with readily available commercial instrumentation to validate the analysis of one class of persistent organic pollutants, polychlorinated biphenyls (PCBs), in avian blood. The volumes used can be reasonably sampled without sacrificing individuals, or comprising breeding or migratorial success. The procedure consists of the pressurized solvent extraction (PSE) of analytes in a novel PSE extraction vessel. The new extraction cell contains a 38-cm long, coiled, re-packable, in situ clean-up column. Lipid elimination, using Florisil, occurs within the coiled region of the extraction vessel, eliminating the requirement for post extraction clean-up. For development, 0.2 g samples of chicken whole blood have been used. Extract volumes are reduced from (30 to 10) cm3, compared to unmodified systems. The new PSE vessel with its integrated clean-up method showed satisfactory performance for the analysis of ten environmentally relevant PCB congeners in chicken whole blood samples with recoveries in the range of (70-130)%. Detection limits using gas chromatography coupled with large volume injection ion-trap mass spectrometry (GC-LVI-ITMS-MS) were in the range of (0.05-0.5) ng g−1. The relative standard deviations for all congeners investigated were better than 5%. This is the first PSE validation to have been conducted on unaltered whole blood samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号