首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
The analysis of chemical warfare agents and their degradation products is an important component of verification of compliance with the Chemical Weapons Convention. Gas and liquid chromatography, particularly combined with mass spectrometry, are the major techniques used to detect and identify chemicals of concern to the Convention. The more polar analytes, and some of the more reactive or highly volatile agents, are usually derivatised to facilitate chromatography, and to impart properties beneficial for detection. This review focuses on derivatisation reactions used in the chromatographic analysis of chemical warfare agents, their degradation products and metabolites.  相似文献   

2.
Solid phase microextraction (SPME) is an increasingly common method of sample isolation and enhancement. SPME is a convenient and simple sample preparation technique for chromatographic analysis and a useful alternative to liquid-liquid extraction and solid phase extraction. SPME is speed and simply method, which has been widely used in environmental analysis because it is a rather safe method when dealing with highly toxic chemicals. A combination of SPME and gas chromatography (GC) permits both the qualitative and quantitative analysis of toxic industrial compounds, pesticides and chemical warfare agents (CWAs), including their degradation products, in air, water and soil samples. This work presents a combination of SPME and GC methods with various types of detectors in the analysis of CWAs and their degradation products in air, water, soil and other matrices. The combination of SPME and GC methods allows for low detection limits depending on the analyte, matrix and detection system. Commercially available fibers have been mainly used to extract CWAs in headspace analysis. However, attempts have been made to introduce new fiber coatings that are characterized by higher selectivities towards different analytes of interest. Environmental decomposition of CWAs leads to the formation of more hydrophilic products. These compounds may be isolated from samples using SPME and analyzed using GC however, they must often be derivatized first to produce good chromatography. In these cases, one must ensure that the SPME method also meets the same needs. Otherwise, it is helpful to use derivatization methods. SPME may also be used with fieldportable mass spectrometry (MS) and GC-MS instruments for chemical defense applications, including field sampling and analysis. SPME fibers can be taken into contaminated areas to directly sample air, headspaces above solutions, soils and water.  相似文献   

3.
Ion mobility spectrometry (IMS) is a proven technology for detection of vapor phase chemical warfare agents. The technology is suitable for field portable instrumentation due to its small size, high sensitivity, speed of analysis, and low power consumption. However, it suffers from a limited dynamic range and potential difficulties in identifying compounds in complex matrices. The use of gas chromatography (GC) coupled to IMS can overcome the difficulty of chemical identification in mixtures by separating the sample into individual components before detection. Using this approach, IMS technology has previously been adapted to detect biological aerosols using an open tube pyrolyzer and a short GC column (Py-GC-IMS). The open sample introduction tube of a Py-GC-IMS instrument would be a convenient configuration to accept aerosol particulates, and while viewed as needed for aerosol trapping, is not optimal for liquid chemical analyses. To examine the usefulness of an existing Py-GC-IMS system for analysis of chemicals in water, an existing open-port sample interface was replaced with a septum-equipped closed tube injector to contain analyte vapors resulting from liquid injection. Tributylphosphate (TBP) was used as a surrogate chemical warfare agent, and aqueous injections into both closed and open tube assemblies were performed. Sample introduction into the closed tube inlet was also accomplished using solid phase microextraction (SPME) preconcentration. The limit of detection for TBP using an open tube, closed tube, and closed tube configuration with SPME sample introduction was 0.980, 0.196, and 0.0098 mg/L, respectively.  相似文献   

4.
A powerful and rapid method has been developed for the identification and quantitative determination of alkyl methylphosphonic acids, which are the degradation products of nerve agents, using liquid chromatography-time-of-flight mass spectrometry with electrospray ionization. Six alkyl methylphosphonic acids were well separated within 16 min. For quantitative analysis, good linearity, sensitivity and reproducibility were obtained by LC-MS in the selected ion monitoring mode. For unambiguous identification of alkyl methylphosphonic acids, fragment ions were produced by in-source collision induced dissociation (CID), and then exact mass measurement of CID fragment ions was performed. The feasibility of applying this technique for detecting these compounds in spiked environmental waters and soils was demonstrated.  相似文献   

5.
The use of solid-phase microextraction (SPME) coupled to ion mobility spectrometry (IMS) to detect precursor and degradation products of chemical warfare agents (CWAs) as soil contaminants was investigated. The development and characterization of a system to interface a thermal desorption solid-phase microextraction inlet with a hand held ion mobility spectrometer was demonstrated. The analytes used in this study were diisopropyl methylphosphonate (DIMP), diethyl methylphosphonate (DEMP), and dimethyl methylphosphonate (DMMP). Two SPME fibers with different stationary phases, 100 μm polydimethylsiloxane (PDMS) and 65 μm polydimethylsiloxane divinylbenzene (PDMS/DVB), were evaluated in this study to determine the optimal fiber and extraction conditions. Better results were obtained with the PDMS fiber. SPME-IMS offered good repeatability and detection of the precursor and degradation products in spiked soil at concentrations as low as 10 μg/g. Sample analysis time was less than 30 min for all the precursor and degradation products.  相似文献   

6.
Solid phase extraction with commercial C-18 cartridges has been applied to the analysis of some well known chemical warfare agents in water samples. Different sample pretreatment and cartridge conditioning procedures, and different extraction solvents were tested to study the optimum conditions for efficient extraction and recovery of the compounds of interest. The eluates were analyzed with a two-channel gas chromatograph equipped with an autosampler and a retention index monitoring system. The suitability of this technique for real samples is discussed: the rapid hydrolysis of many of the compounds studied and the poor recoveries of the polar degradation products are practical limitations of the method.  相似文献   

7.
离子液体作为一类安全稳定、环境友好的新型介质,因其具有别于传统挥发性有机溶剂的独特的性质,开始用于化学研究的很多领域.在分析检测中,离子液体的研究主要集中在分离富集、电化学分析与传感器、光谱与质谱等方面.本文评述了离子液体在这些领域的应用,并对其前景进行了展望.  相似文献   

8.
To elucidate the current extent of pollution of the environment with diphenylarsine chloride (DA, Clark I) and diphenylarsine cyanide (DC, Clark II), we have developed analytical procedures using gas and liquid chromatography and employed them to analyze water and soil samples. DA, DC, and their degradation products were extracted with water or organic solvents. Derivatization with n‐propanethiol was adopted to achieve higher analytical reproducibility. DA and DC were unstable and decomposed into bis(diphenylarsine)oxide (BDPAO) in water, but only negligibly into diphenylarsinic acid (DPAA) during the 30 days of a stability test. Diphenylarsenic compounds afforded the same product by this derivatization, but their reaction rates varied depending on the starting materials. DPAA had to be treated under acidic conditions at 60 °C to achieve the desired conversion efficiency. Recovery of the thiol derivatives of the diphenylarsenic compounds tested was almost quantitative from water, but only about 50% from soil, reflecting the low extraction efficiency. We applied the method to the analysis of organoarsenic compounds sampled from the water of the drinking well in Kamisu‐cho, Ibaraki Prefecture, where the water was thought to have had deleterious effects on the inhabitants. The high level of DPAA was identified as the causative agent. Our analyses of soil samples from Samukawa‐cho and Hiratsuka City, Kanagawa Prefecture, where a naval arsenal had previously stood, succeeded in identifying intact DA, BDPAO and triphenylarsine, diphenylarsenic thiol‐derivatives, as well as other substances (mustard gas, lewisite). The true magnitude of contamination became evident after these measurements. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

9.
The analysis of samples contaminated by organic compounds is an important aspect of environmental monitoring. Because of the complex nature of these samples, isolating target organic compounds from their matrices is a major challenge. A new isolation technique, solid phase microextraction, or SPME, has recently been developed in our laboratory. This technique combines the extraction and concentration processes into one step; a fused silica fiber coated with a polymer is used to extract analytes and transfer them into a GC injector for thermal desorption and analysis. It is simple, rapid, inexpensive, completely solvent-free, and easily automated. To minimize matrix interferences in environmental samples, SPME can be used to extract analytes from the headspace above the sample. The combination of headspace sampling with SPME separates volatile and semi-volatile analytes from non-volatile compounds, thus greatly reducing the interferences from non-target compounds. This paper reports the use of headspace SPME to isolate volatile organic compounds from various matrices such as water, sand, clay, and sludge. By use of the technique, benzene, toluene, ethyl-benzene, and xylene isomers (commonly known as BTEX), and volatile chlorinated compounds can be efficiently isolated from various matrices with good precision and low limits of detection. This study has found that the sensitivity of the method can be greatly improved by the addition of salt to water samples, water to soil samples, or by heating. Headspace SPME can also be used to sample semi-volatile compounds, such as PAHs, from complex matrices.  相似文献   

10.
Microextraction-based sample preparation techniques have exhibited remarkable importance in analytical chemistry since they were first developed in the 1980s. The application of these techniques involves efficient and, at the same time, environmentally-friendly analytical methodologies. They are also generally faster when compared with classical sample preparation techniques, requiring low solvent and sample volumes, and also allowing for automated or semi-automated procedures. This paper provides an overview of the basic principles of sample preparation techniques and the important applications and developments that have taken place in this area over the past five years. These procedures include solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE), bar adsorptive microextraction (BAμE), rotating disk sorptive extraction (RDSE), micro solid-phase extraction (μ-SPE) and liquid-phase microextraction (LPME). The main variations are discussed with a focus on recent applications in the analysis of environmental water samples. Lastly, some of the trends and perspectives associated with these outstanding microextraction sample preparation approaches are highlighted.  相似文献   

11.
Chemical warfare agents and their degradation products represent a broad group of compounds with different chemical properties (polarity, volatility, thermostability, etc.). These chemicals often have to be detected and determined in complex matrices and therefore highly efficient separation techniques hyphenated to selective and sensitive detectors play an indispensable role. This review offers an overview of selected papers devoted to the title subject. It cannot be considered as a comprehensive literature compilation but should allow the reader to obtain an insight into the application of separation techniques in the important area of human protection and control of chemical weapons.  相似文献   

12.
A novel analytical method has been developed and validated for the quantification of alkyl phenols in aqueous and soil samples. Fabric phase sorptive extraction, a new sorptive microextraction technique, has been employed for the preconcentration of some endocrine‐disruptor alkylphenol molecules, namely, 4‐tert‐butylphenol, 4‐sec‐butylphenol, 4‐tert‐amylphenol, and 4‐cumylphenol, followed by high‐performance liquid chromatography with ultraviolet detection. Various parameters influencing the fabric phase sorptive extraction performance, namely, extraction time, eluting solvent, elution time and pH of the sample matrix, were optimized. The chromatographic separation was carried out with a mobile phase of acetonitrile/water (60:40 v/v) at an isocratic flow rate of 1.0 mL/min using a reversed‐phase C18 column at λmax 225 nm. The calibration curves of target analytes were prepared in the concentration range 5–500 ng/mL with good coefficient of determination values (R2 > 0.992). Extraction efficiency values were 74.0, 75.6, 78.0, and 78.3 for 4‐tert‐butylphenol, 4‐sec‐butylphenol, 4‐tert‐amylphenol, and 4‐cumylphenol, respectively. The limits of detection range from 0.161 to 0.192 ng/mL. Subsequently, the new fabric phase sorptive extraction with high‐performance liquid chromatography and ultraviolet detection was successfully applied for the recovery of alkyl phenols from spiked ground water, river water, and treated water from a sewage treatment plant, and soil and sludge samples.  相似文献   

13.
Diphenylarsinic acid (DPAA) and phenylarsonic acid (PAA), which were degradation products of organoarsenic chemical warfare agents used as sternutatory gas, were detected in the well water at Kamisu, Ibaraki Prefecture, Japan. The standard material of DPAA was synthesized with aqueous arsenic acid and phenylhydrazine in order to determine organic arsenic compounds in well water. The DPAA showed a protonated ion at m/z 263 [M + H]+ and a loss of H2O ion at m/z 245 [M + H ? H2O]+ from protonated ion by the electrospray ionization time‐of‐flight mass spectrometry. The quantitative analysis of DPAA and PAA was performed by high‐performance liquid chromatography inductively coupled plasma mass spectrometry and the system worked well for limpid liquid samples such as well water. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

14.
In this review, recent methods developed for the determination of degradation intermediates of personal care products in environmental matrixes focusing on the extraction and determination steps are discussed. The five classes of personal care products evaluated are stimulants, fragrances, sunscreens, antimicrobials, and insect repellents. Methods are critically reviewed in terms of the analytical steps involved in the analysis, sample pretreatment, separation, and detection as well as the different confirmation strategies employed. Preconcentration from aqueous matrixes was performed by solid-phase extraction, liquid–liquid extraction, or solid-phase microextraction, allowing the simultaneous extraction of parent compounds and their degradation intermediates. Following the extraction and cleanup steps, the identification and quantification of degradation intermediates of personal care products at environmental levels (i.e., parts per trillion to parts per billion range) is usually performed by using mass spectrometry techniques such as single quadrupole mass spectrometry and more recently by time-of-flight mass spectrometry or tandem mass spectrometry. The main scope of this review is to critically evaluate the current state of the art of the analytical techniques used and to identify the research needs in the determination of degradation intermediates of personal care products in environmental matrixes.  相似文献   

15.
The natural background of anions encountered when analyzing soil samples by ion chromatography (IC) present significant problems in the separation, detection and quantification of isopropyl methylphosphonic acid (IMPA) and methylphosphonic acid (MPA), the degradation products of sarin, a chemical warfare nerve agent. Using chemically-suppressed IC with conductivity detection, a commercially available ion-exchange column, and an isocratic binary eluent system, IMPA and MPA were determined in aqueous extracts of soil at sub-ppm (μg/g) concentrations without the need for gradient elution or organic solvent eluent modifiers. Common soil anions such as chloride, nitrate, sulfate and phosphate do not interfere with the analysis method due to the composition of the binary eluent allowing for greater mobilization of multivalent anions (e.g., MPA, carbonate, and sulfate) while monovalent anions (e.g., IMPA and nitrate) are relatively unaffected. Carbonate is selectively removed by in-line respeciation to bicarbonate.  相似文献   

16.
A packed capillary liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification of chemical warfare agents, their degradation products and related compounds in synthetic tabun samples and in soil samples collected from a former mustard storage site. A number of organophosphorus and organosulfur compounds that had not been previously characterized were identified, based on acquired high-resolution ESI-MS data. At lower sampling cone voltages, the ESI mass spectra were dominated by protonated, sodiated and protonated acetonitrile adducts and/or their dimers that could be used to confirm the molecular mass of each compound. Structural information was obtained by inducing product ion formation in the ESI interface at higher sampling cone voltages. Representative ESI-MS mass spectra for previously uncharacterized compounds were incorporated into a database as part of an on-going effort in chemical warfare agent detection and identification. The same samples were also analyzed by capillary column gas chromatography (GC)-MS in order to compare an established method with LC-ESI-MS for chemical warfare agent identification. Analysis times and full-scanning sensitivities were similar for both methods, with differences being associated with sample matrix, ease of ionization and compound volatility. GC-MS would be preferred for organic extracts and must be used for the determination of mustard and relatively non-polar organosulfur degradation products, including 1,4- thioxane and 1,4-dithiane, as these compounds do not ionize during ESI-MS. Diols, formed following hydrolysis of mustard and longer-chain sulfur vesicants, may be analyzed using both methods with LC-ESI-MS providing improved chromatographic peak shape. Aqueous samples and extracts would, typically, be analyzed by LC-ESI-MS, since these analyses may be conducted directly without the need for additional sample handling and/or derivatization associated with GC-MS determinations. Organophosphorus compounds, including chemical warfare agents, related compounds and lower volatility hydrolysis products may all be determined during a single LC-ESI- MS analysis. Derivatization of chemical warfare agent hydrolysis products and other compounds with hydroxyl substitution would be required prior to GC-MS analysis, giving LC-ESI-MS a definite advantage over GC-MS for the analysis of samples containing chemical warfare agents and/or their hydrolysis products.  相似文献   

17.
A dispersive solid-phase microextraction (dispersive-SPME) method for the determination of tetracycline, oxytetracycline, chlortetracycline and doxycycline is proposed. Different silica-based and polymeric sorbents were evaluated for their capacity to simultaneously preconcentrate tetracyclines (TCs) in the dispersive format from aqueous or organic solutions. Silica-based sorbents especially functionalized with primary amine, secondary amine, or carbonyl groups have showed higher capacity than polymeric sorbents under organic environment. In the proposed dispersive solid-phase microextraction method, after extraction with acetonitrile and salt-promoted partitioning, TCs were adsorbed to a small amount of dispersive silica-based primary and secondary amine sorbents, desorbed with a small volume of desorption solution, and determined by high-performance liquid chromatography with diode-array detection. Under the optimal conditions, recoveries were determined for surface water and milk samples spiked at 10 ng/mL and 50–150 ng/g, respectively, and quantification was achieved by matrix-matched calibration. The calibration curves of four TCs in both samples showed linearity with a correlation coefficient value above 0.997. Average recoveries ranged from 97.1 to 104.1% and the precision was from 2.0 to 5.6%. Limits of detection ranged from 0.7 to 3.5 ng/mL and from 7.9 to 35.3 ng/g for four TCs surface in surface water and milk samples, respectively.  相似文献   

18.
Recently the connection between oxidative stress and various diseases, including cancer and Alzheimer's, attracts notice as a pathway suitable for diagnostic purposes. 8‐Oxo‐deoxyguanosine and 8‐oxo‐deoxyadenosine produced from the interaction of reactive oxygen species with DNA become prominent as biomarkers. Several methods have been developed for their determination in biofluids, including solid‐phase extraction and enzyme‐linked immunosorbent assays. However, still, there is a need for reliable and fast analytical methods. In this context, solid‐phase microextraction offers many advantages such as flexibility in geometry and applicable sample volume, as well as high adaptability to high‐throughput sampling. In this study, a solid‐phase microextraction method was developed for the determination of 8‐oxo‐deoxyguanosine and 8‐oxo‐deoxyadenosine in biofluids. The extractive phase of solid‐phase microextraction consisted of hydrophilic–lipophilic balanced polymeric particles. In order to develop a solid‐phase microextraction method suitable for the determination of the analytes in saliva and urine, several parameters, including desorption solvent, desorption time, sample pH, and ionic strength, were scrutinized. Analytical figures of merit indicated that the developed method provides reasonable interday and intraday precisions (<15% in both biofluids) with acceptable accuracy. The method provides a limit of quantification for both biomarkers at 5.0 and 10.0 ng/mL levels in saliva and urine matrices, respectively.  相似文献   

19.
Headspace solid phase microextraction (HS-SPME) was optimized for the analysis of pesticides with gas chromatography electron capture detection (GC-ECD) and high-resolution mass spectrometry. Factors influencing the extraction efficiency such as fiber type, extraction mode and temperature, effect of ionic strength, stirring and extraction time were evaluated. The lowest pesticide concentrations that could be detected in spiked aliquots after HS-SPME–GC-ECD ranged from 0.0005 to 0.0032 μg L− 1. Consequently hexachlorobenzene, trans-chlordane, 4,4′-DDD and 4,4′-DDE were detected in water samples after HS-SPME at concentrations ranging from 2.4 to 61.4 μg L− 1 that are much higher than the 0.1 μg L− 1 maximum limit of individual organochlorine pesticides in drinking water set by the European Community Directive. The same samples were cleaned with ISOLUTE C18 SPE sorbent with an optimal acetone/n-hexane (1:1 v/v) mixture for the elution of analytes. No pesticides were detected after SPE clean-up and pre-concentration. Precision for both methods was satisfactory with relative standard deviations less than 20%. This work demonstrated the superiority of HS-SPME as a sample clean-up and pre-concentration technique for pesticides in water samples as well as the need to identify and control point sources of pesticides.  相似文献   

20.
The paper describes a novel SPME-based approach for sampling and analysis of transformation products of highly reactive and toxic unsymmetrical dimethylhydrazine (UDMH) which is used as a fuel in many Russian, European, Indian, and Chinese heavy cargo carrier rockets. The effects of several parameters were studied to optimize analyte recovery. It was found that the 85 μm Carboxen/polydimethylsiloxane fiber coating provides the highest selectivity for selected UDMH transformation products. Optimal sampling/sample preparation parameters were determined to be 1-h soil headspace sampling time at 40 °C. The GC inlet temperature was optimized to 170 °C held for 0.1 min, then 1 °C s−1 ramp to 250 °C where it was held for 40 min. Temperature programing resulted in a fast desorption along with minimal chemical transformation in the GC inlet. SPME was very effective extracting UDMH transformation products from soil samples contaminated with rocket fuel. The use of SPME resulted in high sensitivity, speed, small labor consumption due to an automation and simplicity of use. It was shown that water addition to soil leads to a significant decrease of recovery of almost all target transformation products of UDMH. The use of SPME for sampling and sample preparation resulted in detection of the total of 21 new compounds that are relevant to the UDMH transformation in soils. In addition, the number of confirmed transformation products of UDMH increased from 15 to 27. This sampling/sample preparation approach can be recommended for environmental assessment of soil samples from areas affected by space rocket activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号