首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
白玉  范玉凡  葛广波  王方军 《色谱》2021,39(10):1077-1085
小分子药物进入人体血液循环系统后与人血清白蛋白(HSA)、α1 -酸性糖蛋白(AGP)等血浆蛋白存在广泛的相互作用,这些相互作用深刻影响药物在体内的分布及其与靶标蛋白的结合,进而影响药物效应的发挥。深入探究药物与血浆蛋白间的相互作用对于候选药物的成药性优化、新药研发、联合用药的风险评控等意义重大。而发展高效、灵敏、准确的分析检测方法是开展药物-血浆蛋白相互作用研究的关键。近年来,色谱技术由于其高通量、高分离性能、高灵敏度等特点在该领域得到了广泛的应用,包括测定血浆蛋白翻译后修饰对药物结合的影响,多种药物的竞争性结合等。其中,高效亲和色谱(HPAC)和毛细管电泳(CE)应用最为广泛,能够通过多种分析方法获取结合常数、结合位点数、解离速率常数等相互作用信息。该文着重综述了HPAC和CE在药物-血浆蛋白相互作用研究中的常用策略及最新研究进展,包括HPAC中常用的前沿色谱法、竞争洗脱法、超快亲和提取法、峰值分析法和峰衰减分析法,以及CE中常用的亲和毛细管电泳法(ACE)和毛细管电泳前沿分析法(CE-FA)等。最后,该文还对当前色谱方法存在的不足进行了总结,并对色谱技术在药物-血浆蛋白相互作用研究领域的应用前景和发展方向进行了展望。  相似文献   

2.
The review presents a comprehensive survey of recent developments and applications of high performance capillary and microchip electroseparation methods (zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography, and electrochromatography) for analysis, micropreparation, and physicochemical and biochemical characterization of peptides since 2017 up to about the middle of 2019. Progress in the study of electromigration properties of peptides and in the methodology of their analysis (sample preseparation, preconcentration and derivatization, adsorption suppression, EOF control, and detection) are described. Advances in CE and CEC methods are demonstrated and their applications in the following areas are presented: qualitative and quantitative analysis, determination in complex (bio)matrices, monitoring of chemical and enzymatical reactions and physical changes, amino acid, sequence and chiral analysis, and peptide mapping of proteins. In addition, micropreparative separations and determinations of important physicochemical characteristics of peptides by CE and CEC methods are reported.  相似文献   

3.
Summary Ion-exclusion chromatography (IEC) and capillary electrophoresis (CE) have been compared for determination of organic acids in samples of Sherry wine vinegar. The accuracy of each technique was evaluated by use of the standard addition method. There were no differences between the techniques at a significance level of 5%, except for determination of malic acid by CE. Both analytical methods were used to analyse sixteen samples of Sherry wine vinegar supplied by different producers. The regression coefficients (r 2) for analysis by IEC and CE exceeded 0.94 for all acids. Results from both methods were in good agreement and the methods are sufficiently selective and sensitive to be applied directly to sherry wine vinegars.  相似文献   

4.
Capillary electrophoresis (CE) is a high-resolution technique for the separation of complex biological and chemical mixtures. CE continues to emerge as a powerful tool in the determination of lipids. Here we review the analytical potential of CE for the determination of a wide range of lipids. The different classes of lipids are introduced, and the different modes of CE and optimization methods for the separation of lipids are described. The advantages and disadvantages of the different modes of CE compared to traditional methods like gas chromatography (GC) and liquid chromatography (LC) in the determination of lipids are discussed. Finally, the potential of CE in the determination of lipids in the future is illustrated.  相似文献   

5.
Summary High-performance capillary electrophoresis (HPCE or CE) is an ultrasensitive analytical technique with high resolving power and a wide area of applications including peptide/protein analysis. Its applicability is greatly enhanced by the short separation times, the ease of method development and the minimum sample and organic solvent requirements. Various HPCE modes have been developed for peptide/protein analysis, including capillary zone electrophoresis, micellar elektrokinetic capillary chromatography, capillary isoelectric focusing, isotachophoresis, capillary gel electrophoresis and microemulsion elektrokinetic chromatography. HPCE can easily be applied to quality control of manufacturing processes or to clinical routine for diagnostic purposes due to its potential to provide information on the identity, the purity of the samples and the quantities of the constituents. Furthermore, interactions of a peptide or a protein with other molecules can be studied by HPCE. The separation principles of the various operation modes applied to peptide/protein analysis are presented in this article. Furthermore, in order to exemplify the application of the separation principles in the area of serum protein analysis, which is of importance in clinical practice, the capillary electrophoretic methods developed for analysis of serum and cerebrospinal fluid proteins are also reviewed.Presented at: International Symposium on Separation and Characterization of Natural and Synthetic Macromolecules, Amsterdam, The Netherlands, February 5–7, 2003  相似文献   

6.
Biomolecules such as serum proteins can interact with drugs in the body and influence their pharmaceutical effects. Specific and precise methods that analyze these interactions are critical for drug development or monitoring and for diagnostic purposes. Affinity capillary electrophoresis (ACE) is one technique that can be used to examine the binding between drugs and serum proteins, or other agents found in serum or blood. This article will review the basic principles of ACE, along with related affinity-based capillary electrophoresis (CE) methods, and examine recent developments that have occurred in this field as related to the characterization of drug–protein interactions. An overview will be given of the various formats that can be used in ACE and CE for such work, including the relative advantages or weaknesses of each approach. Various applications of ACE and affinity-based CE methods for the analysis of drug interactions with serum proteins and other binding agents will also be presented. Applications of ACE and related techniques that will be discussed include drug interaction studies with serum agents, chiral drug separations employing serum proteins, and the use of CE in hybrid methods to characterize drug binding with serum proteins.  相似文献   

7.
钱金雄  杨秀娟  陈缵光 《色谱》2011,29(4):298-302
人类重大疾病特异性蛋白质的识别、鉴定等是目前生命科学亟待解决的问题。毛细管电泳技术用于蛋白质分析,具有装置简单、分析速度快、试剂和样品消耗少以及有多种分离模式和检测手段等特点。本文综述了毛细管电泳技术在人类重大疾病特异性蛋白质分析中的应用,包括肿瘤疾病、神经退行性疾病和输血性传染病等的特异性蛋白质检测。  相似文献   

8.
Summary The resolution of chiral drugs, metabolites and related substances continues to be an important area in pharmaceutical analysis. Two methods for the optical purity testing of (R)-(-)-terbutaline were developed, namely capillary electrophoresis using hydroxypropyl-β-cyclodextrin and high-performance liquid chromatography using a chiral stationary phase. Validation data such as linearity, recovery, detection limit, and precision of the two methods are presented. The detection limit of (S)-terbutaline in (R)-terbutaline was 0.05% by the HPLC method and 0.03% by the CE method. The was generally good agreement between the HPLC and CE results. These methods were found to be applicable as a practical quality control method for the enantiomeric purity determination of(R)-terbutaline.  相似文献   

9.
毛细管电泳在食品分析中的应用   总被引:2,自引:0,他引:2  
许元红  唐亚军  吴明嘉 《分析化学》2005,33(12):1794-1798
介绍了近年来国内外毛细管电泳(CE)在食品分析中的应用,包括蛋白质、氨基酸、生物胺、维生素、碳水化合物、无机离子、有机酸、食品添加剂、农药和抗生素残留、生物毒素等食品中一些物质的测定。引用文献59篇。  相似文献   

10.
综述了毛细管电泳与电喷雾质谱联用的接口技术、分离模式及其在蛋白质分析领域中的应用,特别是毛细管等电聚焦与电喷雾质谱联用在蛋白质组学中研究进展。  相似文献   

11.
Laser‐induced fluorometry (LIF) has achieved the detection of single molecules, which ranks it among the most sensitive of detection techniques, whereas capillary electrophoresis (CE) is known as a powerful separation method with resolution that is beyond the reach of many other types of chromatography. Therefore, a coupling of LIF with CE has established an unrivaled analytical technique in terms of sensitivity and resolution. CE‐LIF has demonstrated excellent performance in bioanalytical chemistry for the high‐resolution separation and highly sensitive detection of DNAs, proteins, and small bioactive molecules. This review describes the CE‐LIF methods developed by the author's group that include indirect and direct detection using diode lasers, post‐column derivatization, and Hadamard transformation, as well as applications to the binding assays of specific DNA immunoassays of proteins and to the determination of anticancer drugs.  相似文献   

12.
A major difficulty in assessing bioremediation in hydrocarbon impacted field sites is the determination of the extent and products of contaminant biodegradation. Previously, various analytical techniques, including mass spectrometry and chromatography, have been used to characterize components in mixtures resulting from biodegradation. In this work, the applicability of capillary electrophoresis (CE) to this area of research is demonstrated. CE methods were optimized for analysis of compounds that are known metabolites of polycyclic aromatic hydrocarbon (PAH) biodegradation.  相似文献   

13.
This review, covering reports published from 2001 to December 2008, shows how ionic liquids (ILs) have made significant contributions in the improvement of capillary and microchip electrophoresis (CE and μCE) for the separation and detection of analytes such as phenols and aromatic acids, metal ions, medicines, enantiomers, biological materials, etc. Furthermore, CE methods applied in the sensitive and accurate determination of physico-chemical properties of ILs have been summarized. Accordingly, research vacancies and future development trends in these areas are discussed.  相似文献   

14.
A new method for protein analysis, that is, electroosmotic pump-assisted capillary electrophoresis (EOPACE), is developed and demonstrated to possess several advantages over other CE-based techniques. The column employed in EOPACE consists of two linked sections, poly(vinyl alcohol) (PVA)-coated and uncoated capillaries. The PVA-coated capillary column is the section for protein electrophoresis in EOPACE. Electroosmotic flow (EOF) is almost completely suppressed in this hydrophilic polymer coated section, so protein electrophoresis in the PVA-modified capillary is free of irreversible protein adsorption to the capillary inner wall. The uncoated capillary section serves as an electroosmotic pump, since EOF towards cathode occurs at neutral pH in the naked silica capillary. By the separation of a protein mixture containing cytochrome c (Cyt-c), myoglobin and trypsin inhibitor, we have demonstrated the advantages of EOPACE method over other relevant ones such as pressure assisted CE, capillary zone electrophoresis (CZE) with naked capillary and CZE with PVA-coated capillary. A significant feature of EOPACE is that simultaneous separation of cationic, anionic and uncharged proteins at neutral pH can be readily accomplished by a single run, which is impossible or difficult to realize by the other CE-based methods. The high column efficiency and good reproducibility in protein analysis by EOPACE are verified and discussed. In addition, separation of tryptic digests of Cyt-c with the EOPACE system is demonstrated.  相似文献   

15.
董娅妮  方群 《色谱》2008,26(3):269-273
重点介绍了近年来国内外在微流控芯片毛细管电泳法用于蛋白质分离分析方面的研究进展。按照分离模式的不同,综述了各种应用于蛋白质分离的微流控芯片毛细管电泳系统,讨论了抑制芯片中的蛋白吸附的各种方法,并展望了芯片毛细管电泳系统在蛋白质分离领域的发展前景。引用文献47篇。  相似文献   

16.
Michele Falcone 《Electrophoresis》2014,35(20):3003-3007
The study of urinary protein has a predominant place in the diagnosis of kidney disease. The most common technique is agarose gel electrophoresis (AGE). For several years, the technique of choice applied to the analysis of serum proteins has been CE, a system that uses capillary fused silica, subjected to high voltage to separate and measure serum proteins. The purpose of this paper was to perform capillary electrophoresis on urinary proteins which, at present, are not interpretable due to the many nonspecific peaks visible when using gel electrophoresis. In order to carry out our research, we used a capillary V8 analyzer together with an agarose gel system from the same company. AGE was taken as the reference method, for which urine was used without any pretreatment. For the V8 system, urine was subjected to purification on granular‐activated carbon and then inserted into the V8 analyzer, selecting a program suitable for liquids with low protein content. We examined 19 urine samples collected over 24 hrs from both hospitalized and external patients with different types of proteinuria plus a serum diluted 1/61 considered as a control to recognize the bands. Both methods showed the same protein fractions and classified the proteinuria in a similar way.  相似文献   

17.
毛细管电泳具有分析时间短,分离效率高,样品消耗量少等优点,在生物样品分离,特别是蛋白质分析领域有重要应用。然而,毛细管内壁硅羟基的解离给分离结果带来诸多不良影响。聚合物涂层能够抑制蛋白质在毛细管内壁的吸附以及调控电渗流,故对毛细管内壁进行有效修饰能够提高其对蛋白质的分离效率及分离稳定性。该文主要综述了动态及静态聚合物涂层毛细管的最新研究进展,并概述了近些年基于多巴胺/聚多巴胺发展起来的涂层毛细管的研究进展,最后展望了聚合物涂层毛细管的发展趋势。  相似文献   

18.
《Electroanalysis》2006,18(2):152-157
Capillary electrophoresis (CE) with contactless conductivity detection (CCD) represents a viable alternative to liquid chromatography in the analysis of amino acids (AA) in human plasma. After optimizing the composition of the background electrolyte (BGE), and introducing simple plasma pretreatment to remove spurious protein components, the CE/CCD methods allows determination of 18 from 20 proteinogenic AAs, three nonproteinogenic AAs and creatinine in 60 minutes. AAs are separated in their cationic forms in BGE containing 1.7 M acetic acid and 0.1% hydroxyethylcellulose, pH 2.2. LODs for individual AAs vary in an acceptable range with minimum of 4.3 μM for Arg and maximum of 42.9 μM for Cys. Mean concentrations and concentrations ranges for AAs in human plasma samples from 9 healthy individuals are found to agree well with those determined by an LC method in other two laboratories.  相似文献   

19.
Lagu AL 《Electrophoresis》1999,20(15-16):3145-3155
Capillary electrophoresis (CE)-related techniques are increasingly being used as a matter of routine practice in the biotechnology discipline. Since recombinant DNA-derived proteins and the antisense oligonucleotides constitute a large portion of the applications of these techniques, they have been emphasized in this review. Analyses by CE of Escherichia coli-derived proteins and glycosylated proteins derived from mammalian cell cultures are summarized, as well as those of the carbohydrate chains that have been enzymatically removed from the protein. Applications of CE in the analysis of the antisense oligonucleotides for the determination of purity and the analytical studies on the metabolism of these modified oligonucleotides, by CE are reviewed. The literature mainly covers the period from 1996.  相似文献   

20.
In this study the outer membrane protein (OMP) composition of six Pseudomonas aeruginosa strains had been analyzed by conventional CE and microchip electrophoresis. Bacterial OMPs are important virulence factors and play a significant role in the pathogenesis of infectious diseases. Changes in their composition might refer to the altered pathogenic properties and antibiotic sensitivity of a certain strain. Pathogenic bacteria invading the human host have to multiplicate under iron-restricted conditions that induce changes in the OMP composition. High-molecular-weight OMPs have to be expressed, which serve as receptors for the iron-siderophore complexes. OMP patterns of bacteria obtained by the two different methods in this study were similar, all major proteins could be detected by both techniques, and the molecular weights showed good correlations, although direct comparison of the peak areas is not straightforward due to the different detection methods (UV and LIF). Changes in OMP composition under iron restriction could be detected, and appearance of a 92 kDa protein in all six P. aeruginosa strains and a 94 kDa protein in the KT 2 strain could be demonstrated. Besides that up- and downregulation of certain proteins could be also detected. The increased separation speed, picoliters of sample consumption, baseline separation achieved more frequently by this method--especially in the high-molecular-weight region--showed the advantages of microchip electrophoresis in the analysis of clinical samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号