首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For enforcement of the recently introduced labeling threshold for genetically modified organisms (GMOs) in food ingredients, quantitative detection methods such as quantitative competitive (QC-PCR) and real-time PCR are applied by official food control laboratories. The experiences of 3 European food control laboratories in validating such methods were compared to describe realistic performance characteristics of quantitative PCR detection methods. The limit of quantitation (LOQ) of GMO-specific, real-time PCR was experimentally determined to reach 30-50 target molecules, which is close to theoretical prediction. Starting PCR with 200 ng genomic plant DNA, the LOQ depends primarily on the genome size of the target plant and ranges from 0.02% for rice to 0.7% for wheat. The precision of quantitative PCR detection methods, expressed as relative standard deviation (RSD), varied from 10 to 30%. Using Bt176 corn containing test samples and applying Bt176 specific QC-PCR, mean values deviated from true values by -7to 18%, with an average of 2+/-10%. Ruggedness of real-time PCR detection methods was assessed in an interlaboratory study analyzing commercial, homogeneous food samples. Roundup Ready soybean DNA contents were determined in the range of 0.3 to 36%, relative to soybean DNA, with RSDs of about 25%. Taking the precision of quantitative PCR detection methods into account, suitable sample plans and sample sizes for GMO analysis are suggested. Because quantitative GMO detection methods measure GMO contents of samples in relation to reference material (calibrants), high priority must be given to international agreements and standardization on certified reference materials.  相似文献   

2.
Lactic acid produced by fermentation process mostly contains a number of aliphatic carboxylic acids as impurities. In this work, carboxylic acid impurities in lactic acid samples from a number of sources were determined at ppm levels. A simple HPLC method was developed that utilized a new generation polar embedded reverse phase, 20mM phosphate buffer at pH 2.20 (±0.05) and UV detection at 210 nm. The method enabled quantitative analysis of the above acids in lactic acid matrix. The experimental conditions for column temperature, mobile phase pH and flow rate were optimized. A detailed validation of the method was performed for linearity, precision, accuracy, selectivity, limit of detection (LOD), limit of quantitation (LOQ), ruggedness and repeatability and reproducibility (R&R).  相似文献   

3.
Nadal A  Coll A  La Paz JL  Esteve T  Pla M 《Electrophoresis》2006,27(19):3879-3888
We present a novel multiplex PCR assay for simultaneous detection of multiple transgenic events in maize. Initially, five PCR primers pairs specific to events Bt11, GA21, MON810, and NK603, and Zea mays L. (alcohol dehydrogenase) were included. The event specificity was based on amplification of transgene/plant genome flanking regions, i.e., the same targets as for validated real-time PCR assays. These short and similarly sized amplicons were selected to achieve high and similar amplification efficiency for all targets; however, its unambiguous identification was a technical challenge. We achieved a clear distinction by a novel CGE approach that combined the identification by size and color (CGE-SC). In one single step, all five targets were amplified and specifically labeled with three different fluorescent dyes. The assay was specific and displayed an LOD of 0.1% of each genetically modified organism (GMO). Therefore, it was adequate to fulfill legal thresholds established, e.g., in the European Union. Our CGE-SC based strategy in combination with an adequate labeling design has the potential to simultaneously detect higher numbers of targets. As an example, we present the detection of up to eight targets in a single run. Multiplex PCR-CGE-SC only requires a conventional sequencer device and enables automation and high throughput. In addition, it proved to be transferable to a different laboratory. The number of authorized GMO events is rapidly growing; and the acreage of genetically modified (GM) varieties cultivated and commercialized worldwide is rapidly increasing. In this context, our multiplex PCR-CGE-SC can be suitable for screening GM contents in food.  相似文献   

4.
Measurement uncertainty in the proposed redox-potentiometric methods for peroxide value (PV) determination in vegetable oils is evaluated in comparison with uncertainty in the standard methods. The methods determine all peroxides in oils, in terms of milliequivalents per kg of sample (meq/kg), that oxidize potassium iodide (KI) under the conditions of the test. The standard methods are based on KI oxidation by the oil test portion and volumetric titration of the liberated iodine, while the proposed methods are using redox-potentiometric iodine determination without titration. As far as fresh refined oils have PV≤0.5 meq/kg, the limit of detection (LOD) and limit of quantitation (LOQ) of the methods are important. An approach to assess the LOD and LOQ using uncertainty calculation was applied. It is shown how important is the influence of the solvents purity on the values of LOD and LOQ. Received: 1 August 2001 Accepted: 20 October 2001  相似文献   

5.
A simple and efficient method for the determination of isopropyl-9H-thioxanten-9-one (ITX) in different fat content milk samples and baby milk samples stored in packaged cartons was developed and validated. Samples were extracted using solid-phase extraction (SPE) and analysed by gas chromatography-tandem mass spectrometry operated in selected reaction monitoring mode (SRM). Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision and trueness. LOD and LOQ values in the low microg/L were achieved, whereas linearity was established within 0.5-500 microg/L range. Good precision was obtained both in terms of intra-day repeatability and inter-day precision on two concentration levels (RSD% lower than 2%). Good percentage recoveries were obtained (92.0-102.0%) even in the presence of high amount of fat. Finally, the developed method was successfully applied to analyse a number of commercial milk samples with different fat content and baby milk samples.  相似文献   

6.
An ultraviolet spectrophotometric method was validated for total flavonoid quantitation, as rutin equivalents, present in the Trichilia catigua Adr. Juss (Meliaceae) and Ptychopetalum olacoides Bentham (Olacaceae) commercial extract. Parameters as linearity, interval (range), specificity, estimated limit of detection (LOD, microg/mL), estimated limit of quantitation (LOQ, microg/mL), recovery (R, %), precision or relative standard deviation (RSD, %), and accuracy (E, %) were established. The analytical method was validated according to the experimental results: correlation coefficient (r = 0.9997); interval (RSD = 0.15-0.47%; E = 98.98-101.24%); specificity to total flavonoids quantitation, as rutin equivalents, at wavelength 361.0 nm; LOD = 0.09 microg/mL and LOQ = 0.27 microg/mL; R = 99.36-102.14%; adequate intra- and interrun precision (0.30-0.49% and 0.31-0.81%), and intra- and interrun accuracy (100.60-102.38% and 98.58-100.38%).  相似文献   

7.
NAIMA as a solution for future GMO diagnostics challenges   总被引:1,自引:0,他引:1  
In the field of genetically modified organism (GMO) diagnostics, real-time PCR has been the method of choice for target detection and quantification in most laboratories. Despite its numerous advantages, however, the lack of a true multiplexing option may render real-time PCR less practical in the face of future GMO detection challenges such as the multiplicity and increasing complexity of new transgenic events, as well as the repeated occurrence of unauthorized GMOs on the market. In this context, we recently reported the development of a novel multiplex quantitative DNA-based target amplification method, named NASBA implemented microarray analysis (NAIMA), which is suitable for sensitive, specific and quantitative detection of GMOs on a microarray. In this article, the performance of NAIMA is compared with that of real-time PCR, the focus being their performances in view of the upcoming challenge to detect/quantify an increasing number of possible GMOs at a sustainable cost and affordable staff effort. Finally, we present our conclusions concerning the applicability of NAIMA for future use in GMO diagnostics.  相似文献   

8.
Considering the increase of the total cultivated land area dedicated to genetically modified organisms (GMO), the consumers’ perception toward GMO and the need to comply with various local GMO legislations, efficient and accurate analytical methods are needed for their detection and identification. Considered as the gold standard for GMO analysis, the real-time polymerase chain reaction (RTi-PCR) technology was optimised to produce a high-throughput GMO screening method. Based on simultaneous 24 multiplex RTi-PCR running on a ready-to-use 384-well plate, this new procedure allows the detection and identification of 47 targets on seven samples in duplicate. To comply with GMO analytical quality requirements, a negative and a positive control were analysed in parallel. In addition, an internal positive control was also included in each reaction well for the detection of potential PCR inhibition. Tested on non-GM materials, on different GM events and on proficiency test samples, the method offered high specificity and sensitivity with an absolute limit of detection between 1 and 16 copies depending on the target. Easy to use, fast and cost efficient, this multiplex approach fits the purpose of GMO testing laboratories.
Figure
A broad multiplex real‐time PCR method for the detection and identification of GMOs  相似文献   

9.
A column high-performance liquid chromatography (HPLC) method was developed for the determination of glucosamine in dosage forms. Glucosamine was derivatized by addition of a solution containing orthophthaldialdehyde. The HPLC separation was achieved on a Spherimage 80 ODS2 column (250 x 4 mm id, 5 microm particle size) using an isocratic mobile phase containing phosphate buffer-methanol (90 + 10, v/v, pH 6.50) and methanol-tetrahydrofuran (97 + 3, v/v) in proportions of 85 + 15 at a flow rate of 1 mL/min, followed by fluorescence detection. The method was validated for specificity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The detector response for glucosamine HCI was linear over the concentration range of 0.1-20 microg/mL with a correlation coefficient of 0.9980. The accuracy was between 99.4 and 100.8%. The LOD and the LOQ were 0.009 and 0.027 microg/mL, respectively. The method was applied to determination of glucosamine in solid dosage forms.  相似文献   

10.
Although PCR technology has obvious limitations, the potentially high degree of sensitivity and specificity explains why it has been the first choice of most analytical laboratories interested in detection of genetically modified (GM) organisms (GMOs) and derived materials. Because the products that laboratories receive for analysis are often processed and refined, the quality and quantity of target analyte (e.g. protein or DNA) frequently challenges the sensitivity of any detection method. Among the currently available methods, PCR methods are generally accepted as the most sensitive and reliable methods for detection of GM-derived material in routine applications.The choice of target sequence motif is the single most important factor controlling the specificity of the PCR method. The target sequence is normally a part of the modified gene construct, for example a promoter, a terminator, a gene, or a junction between two of these elements. However, the elements may originate from wildtype organisms, they may be present in more than one GMO, and their copy number may also vary from one GMO to another. They may even be combined in a similar way in more than one GMO. Thus, the choice of method should fit the purpose. Recent developments include event-specific methods, particularly useful for identification and quantification of GM content. Thresholds for labelling are now in place in many countries including those in the European Union. The success of the labelling schemes is dependent upon the efficiency with which GM-derived material can be detected. We will present an overview of currently available PCR methods for screening and quantification of GM-derived DNA, and discuss their applicability and limitations. In addition, we will discuss some of the major challenges related to determination of the limits of detection (LOD) and quantification (LOQ), and to validation of methods.  相似文献   

11.
Reboxetine is a new norepinephrine reuptake inhibitor (NRI) drug recently introduced in the therapy for depressed patients. It is effective in the treatment of severe depression and safer to use than traditional tricyclic antidepressants. In this paper an original high-performance liquid chromatography (HPLC) method with ultraviolet detection for the determination of reboxetine in human plasma is described. It uses a C8 reversed-phase column and a mobile phase composed of acetonitrile and aqueous tetramethylammonium perchlorate. For the analysis of plasma samples containing very low levels of reboxetine, another HPLC method with fluorimetric detection was developed (limit of quantitation, LOQ=11 ng ml(-1); limit of detection, LOD=4 ng ml(-1)). The fluorimetric method is based on precolumn derivatisation of reboxetine with 9-fluorenylmethyl chloroformate. An accurate sample pretreatment of human plasma samples has been implemented by means of solid-phase extraction (SPE) on Oasis HLB (hydrophilic-lipophilic balance) cartridges with very high extraction yields (>95%). Both methods were applied to the analysis of plasma samples from depressed patients undergoing therapy with reboxetine and gave satisfactory results in terms of precision (RSD<4.5%) and accuracy (mean recovery>94%).  相似文献   

12.
An assay method with mass spectrometric detection was developed for the quantitative analysis of a pharmaceutical compound and its major metabolite in human plasma using chip-based infusion. Liquid-liquid extraction sample preparation was found to be essential to minimize matrix suppression and to achieve a limit of quantitation (LOQ) of 2.5 ng/mL using a 100 microL plasma aliquot. The potential for simultaneous quantitation in selected reaction monitoring (SRM), tandem mass spectrometry (MS/MS) (enhanced product ion), and MS(3) was investigated and found to be very beneficial in improving assay selectivity. A novel concept for monitoring quantitative assay performance using a SRM/MS(3) ratio is proposed.  相似文献   

13.
Among more than 50 provitamin carotenoids, beta-carotene is the most metabolically active source of retinol. Despite diets rich in fruits and vegetables containing beta-carotene, vitamin A deficiency is the leading cause of blindness and childhood mortality in developing countries. In addition, the uncertainty of beta-carotene bioconversion into vitamin A suggests that new data are needed to update the nutritional guidelines in developed countries. Previously, we reported the development of a carotene/retinol plateau isotopic enrichment method (CarRet PIE) for the determination of beta-carotene bioavailability and bioconversion into retinol, which utilizes positive ion atmospheric pressure chemical ionization (APCI) liquid chromatography/mass spectrometry (LC/MS). While seeking to validate the CarRet PIE using a mass balance approach requiring fecal measurements of beta-carotene and retinol, interference was encountered that required substantial modifications of the LC/MS assay. Here we report a new LC/MS assay that is based on the detection of molecular anions of beta-carotene using negative ion APCI with a reversed-phase C30 column for HPLC separation. Sample preparation required saponification to eliminate interfering triglycerides. The limit of detection (LOD) of beta-carotene was 0.25 pmol calculated on the basis of an injection of 20 microL of 0.0125 microM beta-carotene, and the limit of quantitation (LOQ) was 1.0 pmol based on the injection of 20 microL of 0.050 microM beta-carotene. The linear range was 1.1 to 2179 pmol on-column. The wide linear range and low LOD and LOQ of this assay facilitated the sensitive and selective quantitative analysis of beta-carotene in both serum and fecal samples in support of an on-going clinical investigation of beta-carotene bioavailability and bioconversion into vitamin A.  相似文献   

14.
A new method is described for the qualitative and quantitative analysis of cyanide, a very short-acting and powerful toxic agent, in human whole blood. It involves the conversion of cyanide into hydrogen cyanide and its subsequent headspace solid-phase microextraction (HS-SPME) and detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode. Optimizing the conditions for the GC/MS (type of column, injection conditions, temperature program) and SPME (choice of SPME fiber, effect of salts, adsorption and desorption times, adsorption temperature) led to the choice of a 75-microm carboxen/polydimethylsiloxane SPME fiber, with D3-acetonitrile as internal standard, and a capillary GC column with a polar stationary phase. Method validation was carried out in terms of linearity, precision and accuracy in both aqueous solutions and blood. The limit of detection (LOD) and limit of quantitation (LOQ) were determined only in aqueous solutions. The assay is linear over three orders of magnitude (water 0.01-10, blood 0.05-10 microg/mL); and the LOD and LOQ in water were 0.006 and 0.01 microg/mL, respectively. Good intra- and inter-assay precision was obtained, always <8%. The method is simple, fast and sensitive enough for the rapid diagnosis of cyanide intoxication in clinical and forensic toxicology.  相似文献   

15.
气相色谱-质谱法快速测定牙膏中的二甘醇   总被引:4,自引:1,他引:3  
建立了气相色谱-质谱法(GC-MS)快速测定牙膏中的二甘醇的方法。牙膏样品经三氯甲烷提取后,应用气相色谱-质谱联用仪,以选择离子监测(SIM)模式对其中的二甘醇进行分析。二甘醇的线性范围为21.24-1062 mg/L,线性相关系数(r)为0.9995;检出限和定量限分别为2.0、5.0 mg/L;高、中、低3种浓度下的回收率在88.51%-101.6%之间,相对标准偏差(RSD)在1.6%-8.11%之间;仪器对二甘醇的响应在24 h内保持稳定。  相似文献   

16.
Bioremediation of toluene and naphthalene in liquid cultures of bacteria grown in the presence of these aromatic compounds as unique sources of carbon was investigated by gas chromatography (GC). For this purpose, a method based on the use of GC with flame ionization detection was developed and validated. Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision and trueness. In the case of naphthalene, LOD and LOQ values of 0.43 and 0.72 mg kg(-1) were achieved. Linearity was established over one order of magnitude in the range of interest, i.e. 10-100 mg kg(-1). Excellent precision was obtained both in terms of intra-day repeatability and between-day precision on two concentration levels (RSD% lower than 0.5%). A recovery of 97.9 +/- 0.2% (n=3) was calculated by addition of 640 mg kg(-1) of naphthalene to the Bushnell & Haas mineral salts basal solution containing the micro-organisms. Findings clearly showed a reduction of the naphthalene content equal to 50% and 75% after two and four weeks of contact with the micro-organisms, whereas a lower degradation was shown in the case of toluene. Finally bioremediation activity was ascribed to two different microbial populations, Bordetella Petrii and Bacillus Sphericus, which survived in the polluted medium.  相似文献   

17.
Quantitative and qualitative methods based on PCR have been developed for genetically modified organisms (GMO). Interlaboratory studies were previously conducted for GMO quantitative methods; in this study, an interlaboratory study was conducted for a qualitative method for a GM soybean, Roundup Ready soy (RR soy), with primer pairs designed for the quantitative method of RR soy studied previously. Fourteen laboratories in Japan participated. Each participant extracted DNA from 1.0 g each of the soy samples containing 0, 0.05, and 0.10% of RR soy, and performed PCR with primer pairs for an internal control gene (Le1) and RR soy followed by agarose gel electrophoresis. The PCR product amplified in this PCR system for Le1 was detected from all samples. The sensitivity, specificity, and false-negative and false-positive rates of the method were obtained from the results of RR soy detection. False-negative rates at the level of 0.05 and 0.10% of the RR soy samples were 6.0 and 2.3%, respectively, revealing that the LOD of the method was somewhat below 0.10%. The current study demonstrated that the qualitative method would be practical for monitoring the labeling system of GM soy in kernel lots.  相似文献   

18.
In this study, the development and validation of an analytical method for the assay of 4,7-phenanthroline-5,6-dione I (dione I) using high-performance liquid chromatography (HPLC) and the determination of its synthetic impurities by employing the method in HPLC-mass spectrometry with atmospheric-pressure chemical ionization and photodiode-array UV detection is reported. The results show that dione I is eluted as a spectrally pure peak resolved from its impurities. 5-Bromo,4-7-phenanthroline is identified as the main impurity. This is supported by elemental analysis of the dione I, which demonstrated the presence of bromine. Validation parameters such as specificity and selectivity, linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness, stability, and system suitability, which are evaluated for this method. The LOD and LOQ are 2.0 microg/mL and 50 microg/mL with a 0.50% relative standard deviation (%RSD), respectively. The calibration curves showed good linearity over the concentration range of 0.05-1.50 mg/mL. The correlation coefficient is > 0.9991 in each case. The %RSD values for intra- and interday precision studies are < 0.40%.  相似文献   

19.
A facile mass spectrometric kinetic method for quantitative analysis of chiral compounds was developed by integrating mass spectrometry based on chemical derivatization and the spectral shape deformation quantitative theory. Chemical derivatization was employed to introduce diastereomeric environments to the chiral compounds of interest, resulting in different abundance distribution patterns of fragment ions of the derivatization products of enantiomers in mass spectrometry. The quantitative information of the chiral compounds of interest was extracted from complex mass spectral data by an advanced calibration model derived based on the spectral shape deformation quantitative theory. The performance of the proposed method was tested on the quantitative analysis of R‐propranolol in propranolol tablets. Experimental results demonstrated that it could achieve accurate and precise concentration ratio predictions for R‐propranolol with an average relative predictive error (ARPE) of about 4%, considerably better than the corresponding results of the mass spectrometric method based on chemical derivatization and the univariate ratiometric model (ARPE: about 12%). The limit of detection (LOD) and limit of quantification (LOQ) of the proposed method for the concentration ratio of R‐propranolol were estimated to be 1.5% and 6.0%, respectively. The proposed method is complementary to the existing methods designed for the quantification of enantiomers such as the Cooks kinetic method.  相似文献   

20.
Real-time PCR (qPCR) is the principal technique for the quantification of pathogen biomass in host tissue, yet no generic methods exist for the determination of the limit of quantification (LOQ) and the limit of detection (LOD) in qPCR. We suggest using the Youden index in the context of the receiver operating characteristic (ROC) curve analysis for this purpose. The LOQ was defined as the amount of target DNA that maximizes the sum of sensitivity and specificity. The LOD was defined as the lowest amount of target DNA that was amplified with a false-negative rate below a given threshold. We applied this concept to qPCR assays for Fusarium verticillioides and Fusarium proliferatum DNA in maize kernels. Spiked matrix and field samples characterized by melting curve analysis of PCR products were used as the source of true positives and true negatives. On the basis of the analysis of sensitivity and specificity of the assays, we estimated the LOQ values as 0.11 pg of DNA for spiked matrix and 0.62 pg of DNA for field samples for F. verticillioides. The LOQ values for F. proliferatum were 0.03 pg for spiked matrix and 0.24 pg for field samples. The mean LOQ values correspond to approximately eight genomes for F. verticillioides and three genomes for F. proliferatum. We demonstrated that the ROC analysis concept, developed for qualitative diagnostics, can be used for the determination of performance parameters of quantitative PCR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号