首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this work, a new stir cake sorptive extraction (SCSE) using polymeric ionic liquid monolith as sorbent was prepared. The sorbent was obtained by in situ copolymerization of an ionic liquid, 1-allyl-3-methylimidazolium bis[(trifluoro methyl)sulfonyl]imide (AMII) and divinylbenzene (DB) in the presence of N,N-dimethylformamide. The influence of the content of ionic liquid and the porogen in the polymerization mixture on extraction performance was studied thoroughly. The physicochemical properties of the polymeric ionic liquid were characterized by infrared spectroscopy, elemental analysis, scanning electron microscopy and mercury intrusion porosimetry. The usefulness of SCSE–AMIIDB was demonstrated by the enrichment of trace benzimidazole anthelmintics. Several parameters affecting the extraction efficiency were investigated, and under the optimized conditions, a simple and effective method for the determination of trace benzimidazoles residues in water, milk and honey samples was established by coupling SCSE–AMIIDB with high performance liquid chromatography/diode array detection (SCSE–AMIIDB–HPLC/DAD). Results indicated that the limits of detection (S/N = 3) for target compounds were 0.020–0.072 μg L−1, 0.035–0.10 μg L−1 and 0.026–0.076 μg L−1 in water, milk and honey samples, respectively. In addition, an acceptable reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations (RSD) of less than 9% and 11%, respectively. Finally, the established AMII–SCSE–HPLC/DAD method was successfully applied for the determination of benzimidazoles residues in milk, honey and environmental water samples. Recoveries obtained for the determination of benzimidazole anthelmintics in spiking samples ranged from 70.2% to 117.6%, with RSD below 12% in all cases.  相似文献   

2.
A stir bar sorptive extraction method for the determination of volatile compounds in orange juices was developed. The extraction variables were optimized using a reduced two‐level factorial screening design (25‐1), and the most suitable analytical conditions for the extraction of the studied compounds were: sample volume 10 mL, extraction time 60 min, stirring speed 1800 rpm, NaCl amount 30% (weight/volume), and twister length 10 mm. The optimized method was further validated, obtaining good linearity and detection and quantification limits low enough to correctly determine the studied compounds. As well, for most of the studied compounds precision and recovery values were good. Several orange juice samples (squeezed and commercial) were extracted following the optimized extraction method and analyzed by gas chromatography coupled to mass spectrometry detection. The method has proven to be suitable for the determination of the aroma of orange juice, of which limonene was the major volatile compound in all the studied samples.  相似文献   

3.
郭炳志  杨振  孙亚明  何丽君 《色谱》2022,40(10):921-928
有效萃取复杂食品样品中的极性污染物是实现其准确测定的瓶颈,也是食品安全分析的难点。针对污染物的结构特点,设计和发展能与之产生特定作用的新型材料是高效萃取的关键。敌草快是一种广谱性除草剂,为碱性的阳离子有机化合物。该文以1-乙烯基咪唑和1,3-丙磺酸内酯为原料合成了磺酸功能化的离子液体,通过自由基聚合反应,将其固载至磁性纳米颗粒表面,得到磺酸功能化的聚(1-乙烯基-3-丙基磺酸基咪唑氯盐)修饰的磁性纳米颗粒(Poly([VPImi-SO3H][Cl])-MP)。采用红外光谱、扫描电镜、振动样品磁强计和热重分析等对其结构、形貌和磁性进行了表征。将其作为磁性固相萃取的吸附剂,萃取青菜中的敌草快。磺酸基的功能化使Poly([VPImi-SO3H][Cl])-MP的表面在一定pH下带有丰富的负电荷,与敌草快之间产生强的静电吸引作用,可实现对敌草快的有效萃取。对影响萃取效率的各种参数如溶液pH、吸附剂质量、吸附时间、解吸剂种类和体积等进行了优化。在优化条件下,结合磁性固相萃取和高效液相色谱技术,对方法的性能及适用性进行了考察。敌草快在0.2~20μg/g...  相似文献   

4.
In this study, a new stir cake sorptive extraction using a boron‐rich monolith as the adsorbent was prepared by the in situ copolymerization of vinylboronic anhydride pyridine complex and divinylbenzene. The effect of preparation parameters, including the ratio of vinylboronic anhydride pyridine complex and divinylbenzene, monomer mixture, and porogen solvent, on extraction performance was investigated thoroughly. The physicochemical properties of the adsorbent were characterized by infrared spectroscopy, scanning electron microscopy, and mercury intrusion porosimetry. Several conditions affecting the extraction efficiency were investigated in detail. Under the optimized conditions, a convenient and sensitive method for the determination of trace fluoroquinolones residues in water and milk samples was established by coupling stir cake sorptive extraction with high‐performance liquid chromatography and diode array detection. The limits of detection for the target compounds were 0.10–0.26 and 0.11–0.22 μg/L for water and milk samples, respectively. In addition, the developed method showed good linearity, repeatability, and precision. Finally, the proposed method was successfully applied for the detection of trace fluoroquinolones residues in environmental water and milk samples. Satisfactory recoveries were obtained for the determination of fluoroquinolones in spiking samples that ranged from 68.8 to 120%, with relative standard deviations below 10% in all cases.  相似文献   

5.
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SBSE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 μg/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.  相似文献   

6.
Polar vinyl monomers have been used for the synthesis of several polymer monoliths, to serve as novel coatings for stir bar sorptive extraction; the monovinyl monomers 2‐hydroxyethyl methacrylate (HEMA) and poly(ethylene glycol) monomethacrylate) (PEGMA) were copolymerized with (apolar) divinylbenzene (DVB) and/or pentaerythritol triacrylate (PETRA), both of which are cross‐linking agents. After the optimization of the most important synthesis parameters, which included the ratio between total monomers and porogen, the nature of the porogen, and the monomer ratios, inter alia, three mechanically stable, polar monolithic coatings for stir bar sorptive extraction were obtained that were based on poly(HEMA‐co‐DVB), poly(HEMA‐co‐PETRA), and poly(PEGMA‐co‐PETRA). Thereafter, and in order to evaluate the hydrophilicity of the resulting monoliths, they were applied as materials in the stir bar sorptive extraction of a group of emerging pollutants with a wide range of polarities. The results showed that both the poly(HEMA‐co‐DVB) and poly(PEGMA‐co‐PETRA) materials could be used to extract both polar and nonpolar compounds by stir bar sorptive extraction, in an effective manner. Taking into account the desired chemical and morphological properties, as well as the extraction efficiencies, the poly(PEGMA‐co‐PETRA) material seemed to be a particularly promising monolith for application as a novel coating in stir bar sorptive extraction.  相似文献   

7.
A comparison of direct immersion solid-phase microextraction (DI-SPME) and stir bar sorptive extraction (SBSE) coupled to liquid chromatography (HPLC) with fluorimetric detection for the rapid analysis of resveratrol isomers is described. For DI-SPME, a polar Carbowax-template resin (CW/TPR) 50 μm fiber was the most efficient and optimum extraction conditions were 40 °C and an extraction time of 30 min, stirring in the presence of 5% (m/v) sodium chloride and 0.07 M acetate/acetic acid buffer (pH 6). Desorption was carried out using the static mode for 10 min. Linearity was obtained in the 5-150 and 2-150 ng mL−1 ranges for trans- and cis-resveratrol, with detection limits of 2 and 0.5 ng mL−1, respectively. When using SBSE, a polydimethylsiloxane (PDMS) twister provided best extraction by means of a derivatization reaction in the presence of acetic anhydride and potassium carbonate. The same time and temperature were used for the extraction step in the presence of 2.5% (m/v) sodium chloride, and liquid desorption was performed with 150 μL of a 50/50 (v/v) acetonitrile/1% (v/v) acetic acid solution in a desorption time of 15 min. Linearity was now between 0.5 and 50 ng mL−1 for trans-resveratrol with a detection limit of 0.1 ng mL−1, while cis-resveratrol could not be extracted. The proposed methods were successfully applied to determining the resveratrol isomer content of wine, must and fruit juices.  相似文献   

8.
The determination of taints in food products currently can involve the use of several sample extraction techniques, including direct headspace (DHS), steam distillation extraction (SDE) and more recently solid phase microextraction (SPME). Each of these techniques has disadvantages, such as the use of large volumes of solvents (SDE), or limitations in sensitivity (DHS), or have only been applied to date for determination of individual or specific groups of tainting compounds (SPME). The use of stir bar sorptive extraction (SBSE) has been evaluated as a quantitative screening method for unknown tainting compounds in foods. A range of commonly investigated problem compounds, with a range of physical and chemical properties, were examined. The method was optimised to give the best response for the majority of compounds and the performance was evaluated by examining the accuracy, precision, linearity, limits of detection and quantitation and uncertainties for each analyte.For most compounds SBSE gave the lowest limits of detection compared to steam distillation extraction or direct headspace analysis and in general was better than these established techniques. However, for methyl methacrylate and hexanal no response was observed following stir bar extraction under the optimised conditions.The assays were carried out using a single quadrupole GC-MS in scan mode. A comparison of acquisition modes and instrumentation was performed using standards to illustrate the increase in sensitivity possible using more targeted ion monitoring or a more sensitive high resolution mass spectrometer. This comparison illustrated the usefulness of this approach as an alternative to specialised glassware or expensive instrumentation. SBSE in particular offers a ‘greener’ extraction method by a large reduction in the use of organic solvents and also minimises the potential for contamination from external laboratory sources, which is of particular concern for taint analysis.  相似文献   

9.
In this study, a novel mixed mode monolithic material was prepared and acted as the SBSE coating. The monolithic material was prepared by in situ copolymerization of methacrylic acid-3-sulfopropyl ester potassium salt (MASE) and divinylbenzene (DB) in the presence of a porogen solvent containing cyclohexanol, 1-dodecanol, and water with azobisisobutyronitrile as initiator. The influences of the contents of the porogen solvent and monomer in the polymerization mixture on the extraction performance were investigated thoroughly. Several characteristic techniques, such as elemental analysis, scanning electron microscopy and infrared spectroscopy were used to characterize the monolithic material. To achieve optimum extraction performance for quinolones, several parameters, including pH value, desorption solvent, ionic strength in sample matrix, extraction and desorption time were investigated. The results show that under the optimized experimental conditions, the method has good sensitivity, linearity, simplicity and low cost. The extraction performance of present method to the target compounds was compared with commercial SBSE which using polydimethylsiloxane as coating and other SBSEs which based on monolithic materials. The comparative results indicate that present SBSE can extract the analytes more effectively than other SBSEs because both ion-exchange and hydrophobic interactions contribute to the extraction of quinolones.  相似文献   

10.
Yuling Hu 《Talanta》2010,82(2):464-4294
A novel stir bar coated with molecularly imprinted polymer (MIP) as selective extraction phase for sorptive extraction of triazine herbicides was developed. The stir bar was prepared by chemically bonding the MIP to the glass bar to improve its stability. A homogeneous and porous structure was observed on the stir bar surface. Extraction performance shows that the MIP-coated stir bar has stronger affinity to the template molecule terbuthylazine as compared with that of the reference stir bar without addition of template. Owning to the shape and structural compatibility, the obtained stir bar also demonstrated specific selectivity to the structural related-compounds of nine triazines, and thus can be applied to simultaneous determination of these compounds from complex samples coupled with high performance liquid chromatography. Four complex samples with different matrix, including rice, apple, lettuce and soil were used to evaluate this proposed method. The limits of detection obtained are in the range of 0.04-0.12 μg L−1, and the recoveries for the spiked rice, apple, lettuce and soil samples were 80.8-107.7%, 80.6-107.8%, 72.0-109.8% and 89.0-114.8% with RSD from 1.2 to 7.9%, respectively. Moreover, this MIP-coated stir bar was firm, durable and can be prepared simply and reproducibly. The developed coating method would be useful to prepare a range of selective stir bars in order to extend the applicability of stir bar sorptive extraction (SBSE) in complex sample analysis.  相似文献   

11.
Lan L  Hu B  Yu C 《Journal of chromatography. A》2010,1217(45):7003-7009
An organic-inorganic hybrid titania-hydroxy-terminated silicone oil (titania-OH-TSO) stir bar coating was prepared by sol-gel method. The extraction performance of titania-OH-TSO coated stir bar was evaluated and compared with poly(dimethysiloxane) (PDMS), poly(dimethysiloxane)-divinylbenzene (PDMS-DVB), poly(dimethysiloxane)-β-cyclodextrin (PDMS-β-CD) and C(18) coated stir bar with five polar drugs of abuse including amphetamine (PA), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA) and ketamine (Ke) as the model analytes. The experimental results revealed that the titania-OH-TSO coated stir bar exhibited highly pH-resistant ability, good preparation reproducibility, superior selectivity and high extraction efficiency for the target compounds. Based on this fact, a new method of titania-OH-TSO coated stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet visible (UV) detection was developed for the analysis of five drugs of abuse in urine samples. The factors affecting the extraction efficiency of SBSE such as sample pH, desorption solvent, sample volume, extraction time, desorption time, stirring rate and ionic strength were investigated and the optimal extraction conditions were established. Under the optimized conditions, the limits of detection (LODs) for titania-OH-TSO coated SBSE-HPLC-UV determination of five polar drugs of abuse were in the range of 2.3-9.1 μg/L with relative standard deviations (RSDs) ranging from 7.3 to 8.9% (c=300 μg/L, n=6), and all of the target compounds exhibited good linearity over a concentration range of 30-3000 μg/L. The developed method was applied to the determination of amphetamines and Ke in urine samples of drug abusers with satisfactory results.  相似文献   

12.
A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL−1 to 50 ng mL−1, and the linear range was from LOQ to 500 ng mL−1, with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients.  相似文献   

13.
Stir bar sorptive extraction is an environmentally friendly microextraction technique based on a stir bar with various sorbents. A commercial stirrer is a good support, but it has not been used in stir bar sorptive extraction due to difficult modification. A stirrer was modified with carbon nanoparticles by a simple carbon deposition process in flame and characterized by scanning electron microscopy and energy‐dispersive X‐ray spectrometry. A three‐dimensional porous coating was formed with carbon nanoparticles. In combination with high‐performance liquid chromatography, the stir bar was evaluated using five polycyclic aromatic hydrocarbons as model analytes. Conditions including extraction time and temperature, ionic strength, and desorption solvent were investigated by a factor‐by‐factor optimization method. The established method exhibited good linearity (0.01–10 μg/L) and low limits of quantification (0.01 μg/L). It was applied to detect model analytes in environmental water samples. No analyte was detected in river water, and five analytes were quantified in rain water. The recoveries of five analytes in two samples with spiked at 2 μg/L were in the range of 92.2–106% and 93.4–108%, respectively. The results indicated that the carbon nanoparticle‐coated stirrer was an efficient stir bar for extraction analysis of some polycyclic aromatic hydrocarbons.  相似文献   

14.
A novel method based on ultrasonic solvent extraction and stir bar sorptive extraction (SBSE) for the analysis of 51 persistent organic pollutants including organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and polybrominated diphenylethers (PBDEs) in soil samples was developed. The different parameters that affect both the extraction of analytes from the soil samples, such as solvent selection, solvent volume, mass of soil, and extraction time, and the partitioning from the solvent/water mixture to the PDMS were studied. The final selected conditions consisted of the extraction of 1 g of soil with 15 mL methanol by sonication for 30 min. The methanol extract was mixed with 85 mL of Milli-Q water and extracted by means of SBSE for 14 h at 900 rpm. The stir bars were analyzed by thermal desorption-GC-mass spectometry (TD-GC-MS). The effects of the matrix on the recovery of the various pollutants under the developed method were studied using two soils with very different physicochemical properties. Method sensitivity, linearity, repeatability, and reproducibility were also studied. Validation and accuracy of the method were conducted by analyzing two commercial certified reference materials (CRMs). The main advantage of this method resides in the fact that a small amount of a nontoxic solvent (methanol) is needed for the extraction of only 1 g of solid sample allowing LODs ranging from 0.01 to 2.0 microg/kg. Repeatability and reproducibility variations were lower than 20% for all investigated compounds. Results of the CRMs verify the high accuracy of this method.  相似文献   

15.
A simple, sensitive, and reliable procedure based on stir bar sorptive extraction coupled with high‐performance liquid chromatography was applied to simultaneously extract and determine three semipolar nitrosamines including N‐nitrosodibutylamine, N‐nitrosodiphenylamine, and N‐nitrosodicyclohexylamine. To achieve the optimum conditions, the effective parameters on the extraction efficiency including desorption solvent and time, ionic strength of sample, extraction time, and sample volume were systematically investigated. The optimized extraction procedure was carried out by stir bars coated with polydimethylsiloxane. Under optimum extraction conditions, the performance of the proposed method was studied. The linear dynamic range was obtained in the range of 0.95–1000 ng/mL (r = 0.9995), 0.26–1000 ng/mL (r = 0.9988) and both 0.32–100 ng/mL (r = 0.9999) and 100–1000 ng/mL (r = 0.9998) with limits of detection of 0.28, 0.08, and 0.09 ng/mL for N‐nitrosodibutylamine, N‐nitrosodiphenylamine, and N‐nitrosodicyclohexylamine, respectively. The average recoveries were obtained >81%, and the reproducibility of the proposed method presented as intra‐ and interday precision were also found with a relative standard deviation <6%. Finally, the proposed method was successfully applied to the determination of trace amounts of selected nitrosamines in various water and wastewater samples and the obtained results were confirmed using mass spectrometry.  相似文献   

16.
A method for determining 68 pesticides in river water using stir bar sorptive extraction (SBSE)-thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described. SBSE sampling was optimized for sample solution pH, salting-out and methanol addition. Although salting-out enhanced the ability of the method to extract most of the pesticides with low absolute recoveries, the absolute recoveries of four pesticides were not improved by salting-out. The detection limits of the method for the pesticides ranged from 0.2 to 20 ng/l. Analyte recoveries from a river water sample spiked with standards at 10 and 100 ng/l were 58.5–132.0% (RSD: 1.8–15.8%) and 61.0–121.3% (RSD: 1.4–20.2%), respectively.  相似文献   

17.
A simple, efficient, and sensitive method for simultaneous determination of sorbic acid (SA), benzoic acid (BA), and cinnamic acid (CA) in juices and soft drinks was developed by stir cake sorptive extraction (SCSE) coupling to high-performance liquid chromatography with diode array detection. The SCSE based on polymeric ionic liquid-based monolith (PILM) as extractive medium was used to concentrate these three organic acid preservatives. Because hydrophobic and ion-exchange interactions co-contributed to the extraction, the PILM-SCSE exhibited a high extractive capability towards analytes. To obtain optimum extraction performance, several SCSE parameters were investigated and discussed, including desorption solvent, pH value, ionic strength in the sample matrix, and the extraction and desorption time. Under the optimized extraction conditions, limits of detection of 0.16, 1.08, and 0.18 μg/L (S/N?=?3) and quantification limits of 0.52, 3.42, and 0.61 (S/N?=?10) were obtained for SA, BA, and CA, respectively. The method also showed good linearity and reproducibility, as well as advantages such as simplicity, low cost, and high feasibility. Finally, the proposed method was successfully applied to the determination of SA, BA, and CA in real juices and soft drinks, and the recoveries ranged from 63.0 to 107 %.  相似文献   

18.
搅拌棒吸附萃取技术与GC-MS联用测定苹果酒挥发性物质   总被引:2,自引:0,他引:2  
研究了检测苹果酒中挥发性物质的一种新方法—搅拌棒吸附萃取(简称SBSE)气质联用技术。对搅拌速度、搅拌时间、温度及加盐量对搅拌棒萃取效果的影响进行了研究。萃取条件为:10 mL苹果酒样加入3 g NaCl,于55℃下以1100 r/min的转速搅拌60 min。搅拌棒萃取出了苹果酒中80种挥发性物质,对其中的49种物质进行了定量。该方法具有良好的线性,所有标准曲线的线性相关系数均大于0.99。方法检出限为0.01~6.37μg/L,定量限为0.03~21.25μg/L,回收率在70.9%~111.4%之间,相对标准偏差均在10%以内。  相似文献   

19.
A practical analytical methodology based on coupling microwave-assisted extraction-stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry (MAE-SBSE-TD-GC-MS) was developed and validated for the characterization of several SVOC in atmospheric particulate matter (PM).The high enrichment capacity of SBSE makes it a powerful tool for improving detection limits and MAE has been useful for overcoming the long extraction times and high volumes of extraction solvent used in traditional methodologies. Relative to Soxhlet extraction followed by GC-MS analysis (EPA Methods 3540 and 8270C), the MAE-SBSE-TD-GC-MS methodology resulted with approximately 104 times better detection limits. Detection limits ranged from 0.3 to 8.3 pg m−3 for pp′-DDD and decachlorobyphenyl, respectively in PM2.5, 24 m3 air sample. The performance of the optimized methodology gave good precisions, with R.S.D. less than 30% for most of the standards, and linearity within the range tested of 0.1-15 μg L−1. Analysis of real PM samples resulted in the identification of compounds in the ng L−1 range.  相似文献   

20.
An easy, fast and reliable analytical method is proposed for the determination of the concentration of volatile phenols (ethyl- and vinylphenols) in wines. The novel stir bar sorptive extraction (SBSE) technique is employed, following a simple and fast procedure that allows 15 samples to be extracted simultaneously using very small sample volume. Extracts are desorbed in a thermodesorption system (TDS) coupled on-line to a gas chromatograph-mass spectrometry system. The SBSE offers better recovery and linear regression coefficient (r2) for the four volatile phenols than solid-phase extraction (SPE). The mass spectrometric detection in selected ion monitoring mode contributes to the lower detection limit and good sensibility obtained with this method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号