首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

2.
A novel, specific and sensitive ultraperformance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was developed for the simultaneous determination of quinapril and its active metabolite quinaprilat in human plasma. The method involves a simple, one‐step extraction procedure coupled with an Acquity UPLC? BEH C18 column (100 × 2.1 mm, i.d., 1.7 µm) with isocratic elution at a flow‐rate of 0.2 mL/min and lisinopril as the internal standard. Detection was performed on a triple‐quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionization. Using 250 µL plasma, the methods were validated over the concentration range 5.010–500.374 ng/mL for quinapril and 10.012–1000 ng/mL for quinaprilat, with a lower limit of quantification of 5.010 ng/mL for quinapril and 10.012 ng/mL for quinaprilat. The intra‐ and inter‐day precision and accuracy were within 10.0%. The recovery was 85.8, 62.6 and 61.3% for quinapril, quinaprilat and lisinopril, respectively. Total run time was 3.0 min only. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
A simple, sensitive, and rapid method for determination of L‐trantinterol in rat plasma was developed for the first time by using LC coupled to MS/MS based on chiral stationary phase. A baseline separation of the enantiomers of trantinterol was achieved on a Chirobiotic V column, using a mixture of acetonitrile–methanol–ammonia–acetic acid (80:20:0.01:0.02, v/v/v/v) as the mobile phase. The detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via ESI. The calibration curve was linear in concentration range from 0.270 to 108 ng/mL in plasma with the lower limit of quantification of 0.270 ng/mL. The intra‐ and interday precision (relative standard deviation) values were within 10.9% and the accuracy (relative error) was from 2.6 to 9.2% at all quality control levels. The method has been successfully applied to a study of L‐trantinterol pharmacokinetics in rats.  相似文献   

4.
A rapid, selective and sensitive high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) method was developed to determine meloxicam in beagle dog plasma. Sample pretreatment involved a one‐step protein precipitation with methanol of 0.1 mL plasma. Analysis was performed on a Venusil ASB‐C18 column with mobile phase consisting of methanol–water (containing 0.1% formic acid) (75:25, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization source. Each plasma sample was chromatographed within 4.1 min. The linear calibration curves for meloxicam was obtained in the concentration range of 10.3–4.12 × 103 ng/mL (r ≥ 0.99). The intra‐ and inter‐day precisions (relative standard deviation) were ≤ 15%, and accuracy (relative error) was within ±7.3%. The method herein described was fully validated and successfully applied to the pharmacokinetic study of meloxicam tablets in beagle dog.  相似文献   

5.
A sensitive, rapid and selective ultra‐performance liquid chromatography–tandem mass spectrometric (UPLC‐MS/MS) method was developed for the determination and pharmacokinetic study of domperidone in human plasma. Diphenhydramine was used as the internal standard. Plasma sample pretreatment involved a one‐step liquid–liquid extraction with a mixture of diethyl ether–dichloromethane (3:2, v/v). The analysis was carried out on an Acquity UPLCTM BEH C18 column. The mobile phase consisted of methanol–water containing 10 mmol/L ammonium acetate and 0.5% (v/v) formic acid (60:40, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionizationsource with positive mode. Each plasma sample was chromatographed within 2.1 min. The standard curves for domperidone were linear (r2 ≥ 0.99) over the concentration range of 0.030–31.5 ng/mL with a lower limit of quantification of 0.030 ng/mL. The intra‐ and inter‐day precision (relative standard deviation) values were not higher than 13% and accuracy (relative error) was from ?7.6 to 1.2% at three quality control levels. The method herein described was superior to previous methods and was successfully applied to the pharmacokinetic study of domperidone in healthy Chinese volunteers after oral administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration.  相似文献   

7.
A rapid, selective and sensitive ultra‐high‐performance liquid chromatography–tandem mass spectrometry method was developed to simultaneously determine oxybutynin and its active metabolite N‐desethyl oxybutynin in rat plasma. A 0.1 mL sample of plasma was extracted with n‐hexane. Chromatographic separation was performed on a UPLC BEH C18 column (2.1 × 100 mm i.d.,1.7 μm) with mobile phase of methanol–water (containing 2 mmol/L ammonium acetate and 0.1% formic acid; 90:10, v/v). The detection was performed in positive selected reaction monitoring mode. Each plasma sample was chromatographed within 3 min. The linear calibration curves were obtained in the concentration range of 0.0944–189 ng/mL (r ≥ 0.99) for oxybutynin and 0.226–18.0 ng/mL (r ≥ 0.99) for N‐desethyl oxybutynin. The intra‐ and inter‐day precision (relative standard deviation) values were not more than 14% and the accuracy (relative error) was within ±7.6%. The method described was superior to previous methods for the quantitation of oxybutynin with three product ions and was successfully applied to a pharmacokinetic study of oxybutynin and its active metabolite N‐desethyl oxybutynin in rat plasma after transdermal administration.  相似文献   

8.
A sensitive, fast and specific method for the quantitation of pinocembrin in human plasma based on high‐performance liquid chromatography–tandem mass spectrometry (LC/MS/MS) was developed and validated. Clonazepam was used as the internal standard (IS). After solid‐phase extraction of 500 μL plasma, pinocembrin and the IS were separated on a Luna C8 column using the mobile phase composed of acetonitrile–0.3 mm ammonium acetate solution (65:35, v/v) at a flow rate of 0.25 mL/min in isocratic mode. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via an electrospray ionization source in negative mode by AB SCIEX Qtrap 5500. The assay was linear from 1 to 400 ng/mL, with within‐ and between‐run accuracy (relative error) from ?1.82 to 0.54%, and within‐ and between‐run precision (CV) below 5.25%. The recovery was above 88% for the analyte at 1, 50 and 300 ng/mL. This analytical method was successful for the determination of pinocembrin in human plasma and applied to a pharmacokinetic study of pinocembrin injection in healthy volunteers after intravenous drip administration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A fast, selective and sensitive ultraperformance liquid chromatography–tandem mass spectrometry method was developed for determination and pharmacokinetic study of anastrozole in human plasma. Plasma sample pretreatment involved a one‐step extraction with diethyl ether of 500 µL plasma. The chromatographic separation was carried out on an Acquity UPLCTM BEH C18 column with a mobile phase consisting of methanol–10 mmol/L ammonium acetate (75:25, v/v) at a flow rate of 0.30 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with positive mode. A high throughput was achieved with a run time of 1.5 min per sample. The standard curve for anastrozole was linear (r2 ≥ 0.99) over the concentration range of 0.0550–27.5 ng/mL with a lower limit of quantification of 0.0550 ng/mL. The intra‐ and inter‐day precision (relative standard deviation) values were not higher than 14% and the accuracy (relative error) was within ±3.2% at three quality control levels. This simple, fast and highly sensitive method was fully validated and successfully applied to a clinical pharmacokinetic study of anastrozole in healthy volunteers after oral administration. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
A hydrophilic interaction chromatography-electrospray ionization tandem mass spectrometric method was developed for determination of anastrozole in human plasma. Anastrozole and irbesartan (internal standard) were extracted from human plasma with a mixture of dichloromethane and methyl tert-butyl ether (30:70, v/v). Analysis of the analytes was performed on a Luna HILIC column with the mobile phase of acetonitrile-10 m m ammonium formate (95:5, v/v) and detected by electrospray ionization tandem mass spectrometry in the selected reaction monitoring mode. The standard curve was linear (r(2) = 0.9992) over the concentration range of 0.10-50.0 ng/mL using 200 μL of plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.2-10.0% and -7.2-3.2%, respectively. The present method was applied successfully to the pharmacokinetic study of anastrozole after oral administration of 1 mg anastrozole tablet to healthy male volunteers.  相似文献   

11.
A selective and sensitive liquid chromatography tandem mass spectrometry method was developed for the simultaneous determination of salviaflaside and rosmarinic acid in rat plasma. Sample preparation was carried out through liquid–liquid extraction with ethyl acetate using curculigoside as internal standard (IS). The analytes were determined by selected reaction monitoring operated in the positive ESI mode. Chromatographic separation was performed on an Agilent Eclipse Plus C18 column (100 × 4.6 mm, 1.8 μm) with a mobile phase consisting of methanol–water–formic acid (50:50:0.1, v/v/v) at a flow rate of 0.3 mL/min. The run time was 1.9 min per sample and the injection volume was 5 μL. The method had an LLOQ of 1.6 ng/mL for salviaflaside and 0.94 ng/mL for rosmarinic acid in plasma. The linear calibration curves were fitted over the range of 1.6–320 ng/mL for salviaflaside and 0.94–188 ng/mL for rosmarinic acid in plasma with correlation coefficients (r2) >0.99. Intra‐ and inter‐day precisions (relative standard deviation) were < 13.5%, and accuracies (relative error) were between −8.6% and 14.5% for all quality control samples. The method was validated and applied to the pharmacokinetics of salviaflaside and rosmarinic acid in plasma after oral administration of Prunella vulgaris extract to rats.  相似文献   

12.
Henatinib maleate (R,Z)‐2‐[(5‐fluoro‐1,2‐dihydro‐2‐oxo‐3H‐indol‐3‐ylidene) methyl]‐5‐(2‐hydroxy‐3‐morpholinopropyl)‐3‐methyl‐5,6,7,8‐tetrahydro‐1H‐pyrrolo[3,2‐c] azepin‐4‐ketone maleate is a potent inhibitor of vascular endothelial growth factor receptors, and is currently under preclinical evaluation as an anticancer drug. A novel method for the quantification of henatinib maleate in rat plasma using high performance liquid chromatography–tandem mass spectrometry has been developed. The analyte (henatinib maleate) and internal standard (papaverine hydrochloride) were extracted from 50 μL of rat plasma by protein precipitation and separated on a C18 column using a mixture of 25 mm ammonium acetate buffer : methanol : acetonitrile (35 : 50 : 15, v/v/v) as mobile phase with a run time of 4.5 min. The detection was performed by means of triple quadrupole mass spectrometer equipped with an ESI interface operating in the multiple‐reaction monitoring mode. A linear response was observed over the concentration range 5.0–1000 ng/mL. The limit of quantification was 5.0 ng/mL. Both intra‐ and inter‐day precision, defined as relative standard deviation, were within 9.7%. Accuracy, defined as relative error, was within ± 3.1%. The developed method was successfully applied to preclinical pharmacokinetic studies of henatinib maleate in rat after a single oral administration of the drug. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A sensitive and accurate HPLC‐MS/MS method was developed for the simultaneous determination of dextromethorphan, dextrorphan and chlorphenamine in human plasma. Three analytes were extracted from plasma by liquid–liquid extraction using ethyl acetate and separated on a Kromasil 60‐5CN column (3 µm, 2.1 × 150 mm) with mobile phase of acetonitrile–water (containing 0.1% formic acid; 50:50, v/v) at a flow rate of 0.2 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The calibration curve was linear over the range of 0.01–5 ng/mL for dextromethorphan, 0.02–5 ng/mL for dextrorphan and 0.025–20 ng/mL for chlorphenamine. The lower limits of quantification for dextromethorphan, dextrorphan and chlorphenamine were 0.01, 0.02 and 0.025 ng/mL, respectively. The intra‐ and inter‐day precisions were within 11% and accuracies were in the range of 92.9–102.5%. All analytes were proved to be stable during sample storage, preparation and analytic procedures. This method was first applied to the pharmacokinetic study in healthy Chinese volunteers after a single oral dose of the formulation containing dextromethorphan hydrobromide (18 mg) and chlorpheniramine malaeate (8 mg). Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A specific, sensitive and rapid method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC‐MS/MS) was developed for the determination of pseudo‐ginsenoside GQ in human plasma. Liquid–liquid extraction was used to isolate the analyte from biological matrix followed by injection of the extracts onto a C8 column with isocratic elution. Detection was carried out on a triple quadrupole tandem mass spectrometer (API‐4000 system) in multiple reaction monitoring mode using negative electrospray ionization. The mobile phase consisted of methanol–10 mm ammonium acetate (90:10, v/v) and the flow rate was 0.3 mL/min. The method was validated over the concentration range of 5.0–5000.0 ng/mL for plasma. Inter‐ and intra‐day precisions (relative standard deviation) were all within 15% and the accuracy (relative error) was ≤9.4%. The lower limit of quantitation was 5.0 ng/mL. The pseudo‐ginsenoside GQ was stable after 8 h at room temperature, 24 h at autosampler and three freeze–thaw cycles (from ?30 to 25 °C). The method was successfully applied to the pharmacokinetic study of pseudo‐ginsenoside GQ in healthy Chinese volunteers. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
A selective and sensitive liquid chromatography tandem mass spectrometry method was developed for the first time for the identification and quantification of curdione in rabbit plasma after vaginal drug administration and intravenous administration of zedoary turmeric oil (ZTO) solution (10 mg/kg). The analysis was performed on a triple‐quadrupole tandem mass spectrometer with multiple reaction monitoring mode via electrospray ionization source in positive ionization mode. After mixing with internal standard diazepam, plasma samples were extracted with ethyl ether–acetic ether (1:1, v/v). Chromatographic separation was carried out on a C18 column with gradient elution using a mixture of water and acetonitrile (both containing 0.1% formic acid) as mobile phases. Linearity ranged over 1.06–106 and 10.6–530 ng/mL (r ≥ 0.995) with the lower limit of quantfication 1.06 ng/mL. The intra‐ and inter‐day precision relative standard deviation values were <12% and the accuracy relative error was from ?10.6 to ?6.1% at all quality control sample levels. The method was applied to a study of the pharmacokinetics of curdione after vaginal drug administration and intravenous administration of ZTO. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
A sensitive, rapid and specific method for the simultaneous quantification of oxysophocarpine (OSC) and its active metabolite sophocarpine (SC) in rat plasma was developed and validated, using a liquid-liquid extraction procedure followed by liquid chromatography/electrospray ionization mass spectrometric (LC/ESI-MS) analysis. The separation was performed on a Zorbax Extend-C(18) column (2.1 mm i.d. x 50 mm, 5 microm) with a C(18) guard column using methanol-water containing 5 mm ammonium acetate (15:85, v/v) as mobile phase. Analysis was performed in selected ion monitoring (SIM) mode with an electrospray ionization (ESI) interface. [M + H](+) at m/z 263 for OSC, [M + H](+) at m/z 247 for SC and [M + H](+) at m/z 249 for matrine (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration ranges 10-1000 ng/mL for OSC and 5-500 ng/mL for SC. The intra- and inter-day precisions (coefficient of variation) were within 7% for both analytes. Their accuracy (relative error) ranged from -6.4 to 1.5%. The limits of detection for OSC and SC were 3 and 1.5 ng/mL, respectively. The limits of quantitation for OSC and SC were 10 and 5 ng/mL, respectively. Recoveries of both analytes were greater than 85% at the low, medium and high concentrations. Both analytes were stable during all sample storage, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of OSC to rats with a dose of 15 mg/kg.  相似文献   

17.
A rapid, sensitive and selective liquid chromatography-tandem spectrometry method was developed and validated for determination of paeoniflorin in rat plasma using geniposide as the internal standard. The samples were pretreated with solid-phase extraction using Extract-Clean cartridges. Separation of paeoniflorin and IS was achieved on a reversed-phase C18 column (50x4.6 mm i.d.) with a mobile phase made up of acetonitrile and 0.05% formic acid (25:75, v/v) at a flow rate of 0.5 mL/min. Detection was carried out on a triple quadrupole tandem mass spectrometer by multiple-reaction monitoring and an electrospray ionization source was employed as the ionization source. The lower limit of quantification obtained was 4 ng/mL (n=6) using 200 microL plasma with an accuracy of -3.67% (relative error) and a precision of 4.13% (relative standard deviation). A good linearity was found in the range of 4-1000 ng/mL. The intra- and inter-day relative standard deviations in the measurement of quality control samples 10, 150 and 800 ng/mL ranged from 3.73 to 4.94% and from 4.31 to 6.56%, respectively. The accuracy was from -3.93 to -1.11% in terms of relative error. The analyte and IS were stable in the battery of stability studies. This method was successfully applied to a pharmacokinetic study of paeoniflorin after a single oral administration of 53.36 mg/kg paeoniflorin to rats.  相似文献   

18.
A sensitive and rapid liquid chromatographic/tandem mass spectrometric method was developed and validated for the determination of sertraline in human plasma. The analyte and internal standard (IS, diphenhydramine) were extracted with 3 mL of diethyl ether/dichloromethane (2:1, v/v) from 0.25 mL plasma, then separated on a Zorbax Eclipse XDB C18 column using methanol/water/formic acid (75:25:0.1, v/v/v) as the mobile phase. The triple quadrupole mass spectrometry was applied via an atmospheric pressure chemical ionization (APCI) source for detection. The fragmentation pattern of the protonated sertraline was elucidated with the aid of product mass spectra of isotopologous peaks. Quantification was performed using selected reaction monitoring of the transitions of m/z 306 --> 159 for sertraline and m/z 256 --> 167 for the IS. The method was linear over the concentration range of 0.10-100 ng/mL. The intra-day and inter-day precisions, expressed by relative standard deviation, were both less than 6.7%. Assay accuracies were within +/-6.9% as terms of relative error. The lower limit of quantification (LLOQ) was identifiable and reproducible at 0.10 ng/mL with a precision of 8.3% and an accuracy of 9.6%. The validated method has been successfully applied for the pharmacokinetic study and bioequivalence evaluation of sertraline in 18 healthy volunteers after a single oral administration of 50 mg sertraline hydrochloride tablets.  相似文献   

19.
《Analytical letters》2012,45(7):1381-1391
Abstract

A rapid, sensitive, and specific liquid chromatography‐electrospray ionization mass spectrometric (LC‐ESI‐MS) method has been developed for quantification of gliclazide in human plasma. The analyte and tolbutamide (internal standard, I.S.) were extracted from plasma samples with n‐hexane–dichloromethane (1:1, v/v) and analyzed on a C18 column. The chromatographic separation was achieved within 4.0 min by using methanol–0.5% formic acid (80:20, v/v) as mobile phase and the flow rate was 1.0 mL/min. Ion signals m/z 324.0 and 271.0 for gliclazide and internal standard were measured in the positive mode, respectively. The method was linear within the range of 2.5–2000 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra‐ and inter‐day precisions were lower than 2.8% in terms of relative standard deviation (RSD). The inter‐day relative error (RE) as determined from quality control samples (QCs) ranged from ?1.93% to 1.85%. This validated method was successfully applied for the evaluation of pharmacokinetic profiles of gliclazide modified‐release tablets in 20 healthy volunteers.  相似文献   

20.
A rapid, sensitive and specific high-performance liquid chromatography/electrospray ionization mass spectrometric (LC-ESI-MS) method was developed and validated for the quantification of madecassoside, a major active constituent of Centella asiatica (L.) Urb. herbs, in rat plasma. With paeoniflorin as an internal standard (IS), a simple liquid-liquid extraction process was employed for the plasma sample preparation. Chromatographic separation was achieved within 6 min on a Shim-pack CLC-ODS column using acetonitrile and water (60:40, v/v) containing 0.1% (v/v) formic acid as the mobile phase. The detection was performed by MS with electrospray ionization interface in negative selected ion monitoring (SIM) mode. The linear range was 11-5500 ng/mL with the square regression coefficient (r(2) ) of 0.9995. The lower limit of quantification was 11 ng/mL. The intra- and inter- day precision ranged from 4.99 to 9.03%, and the accuracy was between 95.82 and 111.80%. The average recoveries of madecassoside and IS from spiked plasma samples were >92%. The developed method was successfully applied to the pharmacokinetic study of madecassoside in rats after an oral administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏