首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Acetaminophen (APAP) is a widely used analgesic and antipyretic drug. It is mainly metabolized by phase 1 and 2 reactions in the liver, and thus it could be involved in many drug–drug interactions. Therefore, the study of APAP metabolism is important in toxicological and pharmacokinetic studies. The objective of this study was to develop a rapid and sensitive method for the determination of APAP and its six metabolites in rat plasma for the pharmacokinetic studies. APAP and its metabolites were separated through a Capcell Pak MGII C18 column and quantitated with a 16 min run in a triple‐quadruple mass spectrometer. The mobile phases were composed of 0.1% formic acid in either 95% water or 95% acetonitrile and analysis was performed twice in positive and negative modes. Validations such as accuracy, precision, recovery, matrix effect and stability were found to be within acceptance criteria of validation guidelines, indicating that the assay was applicable to the determination of the plasma concentrations of drug and its six metabolites. In conclusion, we developed an LC‐MS/MS method for the quantitative analysis of APAP and its six metabolites in rat plasma, and this method appears to be useful for pharmacokinetic/toxicokinetic studies of APAP and its metabolites in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
A sensitive, rapid and specific liquid chromatography–electrospray ionization–tandem mass spectrometry method was developed and validated for the determination of aristolochic acid‐I (AA‐I) in rat plasma. Finasteride was used as the internal standard (IS). The analyte was separated on a Zorbax Eclipse XDB‐C18 column by isocratic elution with methanol‐10 mM ammonium acetate (75:25, v/v, pH = 7.3) at a flow rate of 0.25 mL/min, and analyzed by mass spectrometry in positive multiple reaction monitoring mode. The precursor‐to‐product ion transitions of m/z 359.0 → 298.2 and m/z 373.1 → 305.2 were used to detect AA‐I and IS, respectively. Good linearity was achieved over a range of 0.4–600 ng/mL. Intra‐ and inter‐day precisions measured as relative standard deviation were less than 13.5%, and accuracy ranged from 94.2 to 97.5%. The developed method was successfully applied in the pharmacokinetic study of AA‐I in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A sensitive and selective liquid chromatography mass spectrometry method for determination of curdione in rabbit plasma was developed. After addition of tramadol as internal standard (IS), protein precipitation by acetonitrile was used for sample preparation. Chromatographic separation was achieved on a Zorbax SB‐C18 (2.1 × 50 mm, 3.5 µm) column with acetonitrile–0.1% formic acid as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive‐ion mode; selective ion monitoring was used for quantification using target fragment ions m/z 237 for curdione and m/z 264 for the IS. Calibration plots were linear over the range of 20–4000 ng/mL for curdione in plasma. The lower limit of quantification for curdione was 20 ng/mL. Mean recovery of curdione from plasma was in the range 94.3–98.4%. The RSD of intra‐day and inter‐day precision were both less than 9%. This method is simple and sensitive enough to be used in pharmacokinetic research for the determination of curdione in rabbit plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

4.
Dendrobine, considered as the major active alkaloid compound, has been used for the quality control and discrimination of Dendrobium which is documented in the Chinese Pharmacopoeia. In this work, a sensitive and simple ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method for determination of dendrobine in rat plasma is developed. After addition of caulophyline as an internal standard (IS), protein precipitation by acetonitrile–methanol (9:1, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 (2.1 ×100 mm, 1.7 µm) column with acetonitrile and 0.1% formic acid as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 264.2 → 70.0 for dendrobine and m/z 205.1 → 58.0 for IS. Calibration plots were linear throughout the range 2–1000 ng/mL for dendrobine in rat plasma. The RSDs of intra‐day and inter‐day precision were both <13%. The accuracy of the method was between 95.4 and 103.9%. The method was successfully applied to pharmacokinetic study of dendrobine after intravenous administration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
An LC‐MS/MS method was developed for the simultaneous determination of vitexin and isovitexin in rat plasma, using puerarin as the internal standard (IS). Plasma samples extracted with protein precipitation procedure were separated on a Diamonsil® C18 column (150 × 4.6 mm, 5 µm) with a mobile phase composed of methanol and 0.1% formic acid (45:55, v/v). The detection was accomplished by multiple reaction monitoring mode in positive electrospray ionization source. The optimized mass transition ion‐pairs for quantitation were m/z 431.2 → 311.1 for vitexin and isovitexin, and m/z 415.1 → 295.1 for IS. The total run time was 7.5 min for each injection. The calibration curves were linear (r2 > 0.99) over the investigated concentration range (2.00–2000 ng/mL) and the lower limits of quantification were 2.00 ng/mL in rat plasma sample. The intra‐ and inter‐day relative standard deviations were no more than 14.9% and the relative errors were within the range of ?3.2–2.1%. The extraction recoveries for both compounds were between 89.3 and 97.3%. The robust LC‐MS/MS method was further applied in the pharmacokinetic study in Sprague–Dawley rats after oral administration of Santalum album L. leaves extract at a dose of 116 mg/kg. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration.  相似文献   

7.
A sensitive and selective liquid chromatography tandem mass spectrometry method for determination of azasetron hydrochloride in rabbit plasma was developed. After addition of doxapram hydrochloride as internal standard (IS), protein precipitation by 10% trichloroacetic acid was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB-C(18) (2.1 × 50 mm, 3.5 μm) column with acetonitrile-water as mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used to quantification using target fragment ions m/z 349.9 → 223.5 for azasetron hydrochloride and m/z 378.9 → 291.8 for the IS. Calibration plots were linear over the range of 6-1000 ng/mL for azasetron hydrochloride in plasma. The lower limit of quantitation for azasetron hydrochloride was 6 ng/mL. The mean recovery of azasetron hydrochloride from plasma was in the range 85.6-92.7%. The RSDs of intra-day and inter-day precision were both less than 12%. This method is simple and sensitive enough to be used in pharmacokinetic research for determination of azasetron hydrochloride in rabbit plasma.  相似文献   

8.
A rapid, sensitive and specific method using liquid chromatography with tandem mass spectrometric detection (LC‐MS) was developed for the analysis of sauchinone in rat plasma. Di‐O‐methyltetrahydrofuriguaiacin B was used as internal standard (IS). Analytes were extracted from rat plasma by liquid–liquid extraction using ethyl acetate. A 2.1 mm i.d. × 150 mm, 5 µm, Agilent Zorbax SB‐C18 column was used to perform the chromatographic analysis. The mobile phase was methanol–deionized water (80:20, v/v). The chromatographic run time was 7 min per injection and the flow‐rate was 0.2 mL/min. The tandem mass spectrometric detection mode was achieved with electrospray ionization interface in positive‐ion mode (ESI+). The m/z ratios [M + Na]+, m/z 379.4 for sauchinone and m/z 395.4 for IS were recorded simultaneously. Calibration curve were linear over the range of 0.01–5 µg/mL. The lowest limit of quantification was 0.01 µg/mL. The intra‐day and inter‐day precision and accuracy of the quality control samples were 2.94–9.42% and 95.79–108.05%, respectively. The matrix effect was 64.20–67.34% and the extraction recovery was 93.28–95.98%. This method was simple and sensitive enough to be used in pharmacokinetic research for determination of sauchinone in rat plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

10.
Crizotinib is a small molecule inhibitor of anaplastic lymphoma kinase (ALK) and can be used to treat ALK‐positive nonsmall‐cell lung cancer. A rapid and simple high‐performance liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of crizotinib in rat plasma using a chemical synthetic compound buspirone as the internal standard (IS). The plasma samples were pretreated by a simple protein precipitation with methanol–acetonitrile (1:1, v/v). Chromatographic separation was successfully achieved on an Agilent Zorbax XDB C18 column (2.1 × 50 mm, 3.5 µm). The gradient elution system was composed of 0.1% formic acid aqueous solution and 0.1% formic acid in methanol solution. The flow rate was set at 0.50 mL/min. The multiple reaction monitoring was based on the transitions of m/z = 450.3 → 177.1 for crizotinib and 386.2 → 122.2 for buspirone (IS). The assay was successfully validated to demonstrate the selectivity, matrix effect, linearity, lower limit of quantification, accuracy, precision, recovery and stability according to the international guidelines. The lower limit of quantification was 1.00 ng/mL in 50 μL of rat plasma. This LC‐MS/MS assay was successfully applied to the quantification and pharmacokinetic study of crizotinib in rats after intravenous and oral administration of crizotinib. The oral absolute bioavailability of crizotinib in rats was 68.6 ± 9.63%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
A selective and sensitive liquid chromatography tandem mass spectrometry method (LC‐MS/MS) was developed and validated for the determination of cefdinir in rat plasma and urine. Following a simple protein precipitation using methanol, chromatographic separation was achieved with a run time of 10 min using a Synergi 4 µ polar‐RP 80A column (150 × 2.0 mm, 4 µm) with a mobile phase consisting of 0.1% formic acid in water and methanol (65:35, v/v) at a flow rate of 0.2 mL/min. The protonated precursor and product ion transitions for cefdinir (m/z 396.1 → 227.2) and cefadroxil, an internal standard (m/z 364.2 → 208.0) were monitored in the multiple reaction monitoring in positive ion mode. The calibration curves for plasma and urine were linear over the concentration range 10–10,000 ng/mL. The lower limit of quantification was 10 ng/mL. All accuracy values were between 95.1 and 113.0% and the intra‐ and inter‐day precisions were <13.0% relative standard deviation. The stability under various conditions in rat plasma and urine was also found to be acceptable at three concentrations. The developed method was applied successfully to the pharmacokinetic study of cefdinir after oral and intravenous administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
BAPTA-AM is the acetoxymethylester of the calcium chelator BAPTA and has demonstrated efficacy in several animal models of cerebral ischemia. This paper describes the development of a method for the determination of BAPTA-AM in rat plasma by liquid chromatography/tandem mass spectrometry. Owing to multiple ester groups in the structure of BAPTA-AM, [M + Na](+) was chosen as the analytical ion for quantification of BAPTA-AM. During the analytical method development, a high percentage of organic solvent and the addition of an amount of sodium acetate and formic acid in the mobile phase were found to favor the sensitivity and reproducibility of [M + Na](+). Poor fragmentation was usually observed in the MS/MS spectra of sodium adduct ions. However, abundant and reproducible fragment ions were observed for the BAPTA-AM sodium adduct ion, and therefore the traditional selective reaction-monitoring mode was used to further improve the sensitivity of MS detection. Because of the lability of the ester bond, a combination of fluoride and hydrochloric acid was applied to minimize the enzymatic hydrolysis, and acetonitrile was chosen to avoid the chemical hydrolysis or solvolysis during the sample collection and preparation procedure. On the basis of these studies, a rapid, sensitive and reproducible method for the determination of BAPTA-AM in rat plasma, using LC/ESI-MS/MS and a simple protein precipitation procedure, was developed and validated. Also, the present method was successfully applied to the determination of BAPTA-AM plasma concentrations for pharmacokinetic studies in rats.  相似文献   

13.
Wang J  Zhu X  Peng Y  Zha W  Feng D  Zhu Y  Wan P  Qi H  He J  Zhou J  Sun J 《Biomedical chromatography : BMC》2012,26(11):1371-1376
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of trans‐stilbene glycoside (SG) in rat plasma. As trans‐SG can be rapidly isomerized under light exposure, trans‐SG plasma samples were prepared in the dark and assayed immediately. Trans‐SG and internal standard were extracted by protein precipitation. Chromatographic separation was achieved on a C18 column with a gradient elution program. The detection of analytes was performed by negative ion via multiple reaction monitoring mode. The precursor‐to‐product ions of m/z 405.1 → 242.9 for trans‐SG and m/z 389.1 → 226.9 for polydatin (internal standard) were monitored. No interference of endogenous components was observed for any plasma samples that we studied.The method was linear over the concentration range of 1.0–1000.0 ng/mL with a good correlation coefficient. The lower limit of quantification was 1.0 ng/mL for trans‐SG. The intra and inter‐batch accuracy for trans‐SG in stable rat plasma samples ranged from 93.3 to 102.7% and the variation was less than 8.1%. The extraction recoveries of trans‐SG in rat plasma were from 102.8 to 112.4% and the matrix effects were also acceptable. This method was successfully applied to pharmacokinetic study of trans‐SG in rats after intravenous administration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
A rapid and sensitive LC‐MS/MS method for the quantification of fenofibric acid in rat plasma was developed and validated. Plasma samples were prepared by liquid–liquid extraction with a mixture of N‐hexane–dichloromethane–isopropanol (100:50:5, v/v/v). Isocratic chromatographic separation was performed on a reversed‐phase Discovery C18 column (2.1 × 50 mm, 5 µm). The mobile phase was methanol–water–formic (75:25:0.25, v/v/v). Detection of fenofibric acid and the internal standard (IS) diclofenac acid was achieved by ESI MS/MS in the negative ion mode using m/z 317 → m/z 213 and m/z 294 → m/z 250 transitions, respectively. The method was linear from 0.005 to 1.250 µg/mL when 100 μL plasma was analyzed. The lower limit of quantification was 0.005 µg/mL. The intra‐ and inter‐day precision values were below 8.2%, and accuracy ranged from ?0.9 to 2.1% in all quality control samples. The recovery was 90.3–94.7% and 83.3% for fenofibric acid and IS, respectively. Total run time for each sample analysis was 2.5 min. The validated method was successfully applied to a pharmacokinetic study in six rats after oral administration of fenofibrate, the ester prodrug of fenofibric acid (equivalent to fenofibric acid 5 mg/kg). The method permits laboratory scientists with access to the appropriate instrumentation to perform rapid fenofibric acid determination. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
Aripiprazole is an important antipsychotic drug. A simple, sensitive and rapid ultra‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC‐ESI‐MS/MS) method was developed and validated for the simultaneous quantification of this compound in rat plasma and brain homogenate. The analyte was extracted from rat plasma and brain homogenate using a weak cation exchange mixed‐mode resin‐based solid phase extraction. The compound was separated on an Agilent Eclipse Plus C18 (2.1 × 50 mm, 1.8 µm) column using a mobile phase of (A) 0.1% formic acid aqueous and (B) acetonitrile with gradient elution. The analyte was detected in positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, recoveries and stability were determined. The LOQ was 0.5 ng/mL for aripiprazole in plasma and 1.5 ng/g in brain tissue. The MS response was linear over the concentration range 0.5–100 ng/mL for aripiprazole in plasma and 1.5–300 ng/g in brain tissue. The precision and accuracy for intra‐day and inter‐day were better than 14%. The relative and absolute recoveries were above 72% and the matrix effects were low. This validated method was successfully used to quantify the rat plasma and brain tissue concentrations of the analyte following chronic treatment with aripiprazole. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
Vinblastine and vincristine, both of which are bisindole alkaloids derived from vindoline and catharanthine, have been used for cancer chemotherapy; their monomeric precursor molecules are vindoline and catharanthine. A simple and selective liquid chromatography mass spectrometry method for simultaneous determination of vindoline and catharanthine in rat plasma was developed. Chromatographic separation was achieved on a C18 (2.1 × 50 mm, 3.5 µm) column with acetonitrile–0.1% formic acid in water as mobile phase with gradient elution. The flow rate was set at 0.4 mL/min. An electrospray ionization source was applied and operated in positive ion mode; selective ion monitoring mode was used for quantification. Mean recoveries were in the range of 87.3–92.6% for vindoline in rat plasma and 88.5–96.5% for catharanthine. Matrix effects for vindoline and catharanthine were measured to be between 95.3 and 104.7%. Coefficients of variation of intra‐day and inter‐day precision were both <15%. The accuracy of the method ranged from 93.8 to 108.1%. The method was successfully applied in a pharmacokinetic study of vindoline and catharanthine in rats. The bioavailability of vindoline and catharanthine were 5.4 and 4.7%, respectively. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
A highly sensitive and specific atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry method was developed for serum pharmacokinetic studies of puerarin in rats. Chromatography was carried out on a reversed-phase Phenomenex Synergi 4 microm Fusion-RP80 column (150 x 2.0 mm i.d.) using a mobile phase consisting of acetonitrile-water (10:90, v/v) in 10 mm NH(4)OAc with a flow rate of 0.2 mL/min. Puerarin was analyzed in the multiple reaction monitoring mode with a precursor/product ion transition of m/z 415/267. The method was demonstrated to be specific and sensitive, and a linear response was observed over a range of 2-5000 ng/mL in rat serum. The validated method was successfully applied to the characterization of the pharmacokinetics of puerarin in rat serum after oral administration to spontaneously hypertensive rats. The blood concentration-time profile of puerarin showed a rapid initial increase, reaching a maximum and then declining within 1 h. Puerarin could not be detected after 24 h. The main pharmacokinetic parameters for puerarin after oral administration were as follows: C(max) (3.54 +/- 2.03 mg/L), T(max) (0.68 +/- 0.37 h), AUC(0-t) (7.29 +/- 3.79 mg h/L), AUC(0-infinity) (9.17 +/- 4.87 mg h/L), T(1/2) (1.7 +/- 0.6 h), CL/F (7.24 +/- 4.27 L/h/kg) and V/F (17.88 +/- 13.55 L/h/kg).  相似文献   

18.
A simple and sensitive LC‐MS method for the determination of periplocin in rat plasma was developed and validated. The chromatographic separation was carried out using a reverse‐phase Kromasil C18 column(150 × 4.6 mm, i.d., 5 µm) with a mobile phase composed of methanol–water (76:24, v/v). The flow rate of mobile phase was 0.8 mL/min. The calibration curve was linear within the concentration range 1–1000 ng/mL. The intra‐ and inter‐day precisions across three validation days over the entire concentration range was lower than 9.2% in terms of relative standard deviation. Accuracy determined at three quality control concentrations ranged from ?2.0 to 6.0% in terms of relative error. The validated method was applied to the pharmacokinetic study of periplocin in rat plasma after intravenous and intramuscular administration. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
A liquid chromatography–tandem mass spectrometric (LC/MS/MS) method was developed for the determination of an atypical antipsychotic drug, lurasidone, in rat plasma. The method involves the addition of acetonitrile and ziprasidone (internal standard) solution to plasma samples, followed by centrifugation. An aliquot of the supernatant was diluted with water and directly injected into the LC/MS/MS system. The separations were performed on a column packed with octadecylsilica (5 μm, 2.0 × 50 mm) with 0.1% formic acid and 0.1% formic acid in acetonitrile as mobile phase and the detection was performed using tandem mass spectrometry by multiple‐reaction monitoring via an electrospray ionization source. The standard curve was linear (r = 0.9982) over the concentration range 0.002–1 μg/mL. The intra‐ and inter‐assay precisions were 1.7 and 8.6%, respectively. The accuracy range was from 90.3 to 101.8%. The lower limit of quantification was 2.0 ng/mL using 50 μL of rat plasma sample. The developed analytical method was successfully applied to the pharmacokinetic study of lurasidone in rats. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of sodium cromoglycate (SCG) in human plasma after a nasal dose of 10.4 mg sodium cromoglycate nasal spray, using pravastatin sodium as the internal standard. The method was validated over a linear range of 0.300-20.0 ng/mL. SCG and I.S. were extracted from 1.0 mL of heparinized plasma by C(18) solid-phase extraction cartridges using methanol as eluting solvent. The dried residue was reconstituted with 100 microL of mobile phase, and 10 microL was injected onto the LC-MS/MS system. Chromatographic separation was achieved on a C(18) column (250 x 4.6 mm i.d., 5 microm particle size) with a mobile phase of methanol-acetonitrile-water (containing 2 mmol/L ammonium acetate; 42.5:42.5:15, v/v/v) at a flow rate of 0.4 mL/min. The analytes were detected with a triple quad LC-MS/MS using ESI with positive ionization. Ions monitored in the multiple reaction monitoring mode were m/z 469.0 (precursor ion) to m/z 245.0 (product ion) for SCG and m/z 447.2 (precursor ion) to m/z327.1 (product ion) for pravastatin sodium (internal standard) The average recovery of SCG from human plasma was 94.88% and the lower limit of quantitation was 0.3 ng/mL. Results from a 3-day validation study demonstrated excellent precision and accuracy across the calibration range of 0.3-20 ng/mL. The method was successfully applied to the pharmacokinetic study of SCG in healthy Chinese volunteers. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号