首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
This work focusses on the estimation of induced photoneutrons energy, fluence, and strength using nuclear track detector (NTD) (CR-39). Photoneutron energy was estimated for three different linear accelerators, LINACs as an example for the commonly used accelerators. For high-energy linear accelerators, neutrons are produced as a consequence of photonuclear reactions in the target nuclei, accelerator head, field-flattening filters and beam collimators, and other irradiated objects. NTD (CR-39) is used to evaluate energy and fluence of the fast neutron. Track length is used to estimate fast photoneutrons energy for linear accelerators (Elekta 10 MV, Elekta 15 MV, and Varian 15 MV). Results show that the estimated neutron energies for the three chosen examples of LINACs reveals neutron energies in the range of 1–2 MeV for 10 and 15 MV X-ray beams. The fluence of neutrons at the isocenter (Φtotal) is found to be (4×106 n cm2 Gy?1) for Elekta machine 10 MV. The neutron source strengths Q are calculated. It was found to be 0.2×1012 n Gy?1 X-ray at the isocenter. This work represents simple, low cost, and accurate methods of measuring fast neutrons dose and energies.  相似文献   

2.
This Letter reports the order of magnitude enhancement in neutron yield from Sahand plasma focus device with krypton seeded deuterium operation. The highest average neutron yield of 2.2×109 neutrons per shot was achieved at 1.00 Torr deuterium with 3% krypton which is higher than the best average neutron yield of 3.18×108 neutrons per shot for pure deuterium operation. Estimation of average neutron energy showed that the maximum and minimum average energies are 2.98±0.6 MeV at 16 kV in 0.25 Torr deuterium with 3% Kr and 2.07±0.2 MeV at 18 kV operation in 0.5 Torr deuterium with 3% Kr, respectively. The anisotropy of neutron emission from Sahand DPF showed that the neutrons are produced mainly by beam-target mechanisms.  相似文献   

3.
Abstract

The change in electrical properties of TGS crystals due to induced defects created by fast neutron irradiation of two different energies (2 and 14 MeV) and different integrated neutron fluxes have been studied in the vicinity of phase transition. It is observed that the electrical conductivity increases with increase of neutron fluence up to 1.7 × 1010 n · cm?2 and the values of the relative change of electrical conductivity in case of 2 MeV are higher than that of 14 MeV neutrons at the same neutron fluence (φ)  相似文献   

4.
At present, high energy electron linear accelerators (LINACs) producing photons with energies higher than 10 MeV have a wide use in radiotherapy (RT). However, in these beams fast neutrons could be generated, which results in undesired contamination of the therapeutic beams. These neutrons affect the shielding requirements in RT rooms and also increase the out-of-field radiation dose to patients. The neutron flux becomes even more important when high numbers of monitor units are used, as in the intensity modulated radiotherapy. Herein, to evaluate the exposure of patients and medical personnel, it is important to determine the full radiation field correctly. A model of the dual photon beam medical LINAC, Siemens ONCOR, used at the University Hospital Centre of Osijek was built using the MCNP611 code. We tuned the model according to measured photon percentage depth dose curves and profiles. Only 18 MV photon beams were modeled. The dependence of neutron dose equivalent and energy spectrum on field size and off-axis distance in the patient plane was analyzed. The neutron source strength (Q) defined as a number of neutrons coming from the head of the treatment unit per x-ray dose (Gy) delivered at the isocenter was calculated and found to be 1.12 × 1012 neutrons per photon Gy at isocenter. The simulation showed that the neutron flux increases with increasing field size but field size has almost no effect on the shape of neutron dose profiles. The calculated neutron dose equivalent of different field sizes was between 1 and 3 mSv per photon Gy at isocenter. The mean energy changed from 0.21 MeV to 0.63 MeV with collimator opening from 0 × 0 cm2 to 40 × 40 cm2. At the 50 cm off-axis the change was less pronounced. According to the results, it is reasonable to conclude that the neutron dose equivalent to the patient is proportional to the photon beam-on time as suggested before. Since the beam-on time is much higher when advanced radiotherapy techniques are used to fulfill high conformity demands, this makes the neutron flux determination even more important. We also showed that the neutron energy in the patient plane significantly changes with field size. This can introduce significant uncertainty in dosimetry of neutrons due to strong dependence of the neutron detector response on the neutron energy in the interval 0.1–5 MeV.  相似文献   

5.
All materials provide, to a lesser or greater extent, shielding against nuclear radiations. Armoured fighting vehicles (AFVs) have steel as the structural material, which appears to be a reasonably good gamma and neutron shield material but a shield of pure iron would not be equally effective against whole range of neutron energies as it has a few resonances in electron volt range, and it reduces energy of fast neutrons to lower energy neutrons. These neutrons will be absorbed through radiative capture and emit gamma radiations. Thus it is essential that an effective shield should contain a large amount of moderating material, hydrogen being preferred with low atomic number materials (B, C, Li) and lead (Pb) to ensure that the neutrons do not diffuse at intermediate energies in the shield as well as gamma attenuation will also take place. In order to have a suitable shield material for armoured vehicles which serves as neutron and gamma radiation attenuator, polyethylene polymer with fillers lining materials are preferred. These materials were evaluated against gamma and fast neutrons using radioactive sources for suitability to fitment into combat vehicle as per the requirement of protection factor values. The detector for gamma radiation was used as Nal(Tl) while for neutron, CR-39 film was used.   相似文献   

6.
E. A. Bogomolov  O. Adriani  G. A. Bazilevskaya  G. C. Barbarino  R. Bellotti  M. Boezio  V. Bonvicini  M. Bongi  S. Bottai  A. Bruno  A. Vacchi  E. Vannuccini  G. I. Vasilyev  S. A. Voronov  A. M. Galper  C. De Santis  V. Di Felice  G. Zampa  N. Zampa  M. Casolino  D. Campana  A. V. Karelin  P. Carlson  G. Castellini  F. Cafagna  A. A. Kvashnin  A. N. Kvashnin  S. V. Koldashov  S. A. Koldobskiy  S. Y. Krutkov  A. A. Leonov  A. G. Mayorov  V. V. Malakhov  M. Martucci  L. Marcelli  W. Menn  M. Merge  V. V. Mikhailov  E. Mocchiutti  A. Monaco  N. Mori  R. Munini  G. Osteria  B. Panico  P. Papini  P. Picozza  M. Pearce  M. Ricci  S. B. Ricciarini  M. F. Runtso  M. Simon  R. Sparvoli  P. Spillantini  Y. I. Stozhkov  Y. T. Yurkin 《Bulletin of the Russian Academy of Sciences: Physics》2017,81(2):132-135
The first results from measuring the spectra of solar neutrons with energies of ~10–1000 MeV in the solar flares of 2006–2015 observed by the PAMELA international space experiment are presented. The PAMELA neutron detector with 3He counters and a moderator with an area of 0.18 m2 allows us to estimate the flux of solar neutrons during solar flares. Solar neutrons with energies of ~10–1000 MeV likely occurred in 21 out of the 24 analyzed flares of 2006–2015.  相似文献   

7.
Activation cross sections for the 89Y(n, 2n)88Y reaction at neutron energies between 12.6 and 17.8 MeV have been measured by using the mixed-powder method and γ-ray detection by a Ge(Li) spectrometer. Using the 27Al(n, α)24Na reaction for monitoring the neutron flux, the measured cross-section values for the 89Y(n, 2n)88Y reaction were found to be 331±32 mb, 603±58 mb, 820±79 mb, 1040±100 mb, 1072±103 mb, 1172±112 mb, 1221±117 mb and 1218±117 mb at the respective incident neutron energies of 12.6±0.1 MeV, 13.3±0.1 MeV, 14.0±0.4 MeV, 14.9±0.3 MeV, 15.1±0.3 MeV, 16.0±0.4 MeV, 16.7±0.5 MeV and 17.8±0.7 MeV. The measured values are compared with the experimental values of others and with the theoretical values obtained from calculations based on the statistical model for the formation of a compound nucleus and its subsequent emission of neutrons.  相似文献   

8.
9.
The angular distribution of neutrons emitted by elastic, inelastic and fission processes on235U were measured at the incident neutron energies of 1.5, 1.9, 2.3, 4.0, 4.5, 5.0 and 5.5 MeV using nanosecond time-of-flight technique. The differential elastic scattering cross sections and their angular distributions at all the seven energies are presented. The total elastic scattering cross sections, angle and energy integrated cross sections for the inelastically scattered neutrons in energy bands of 200 keV, fission cross sections and the angular distributions of fission neutrons were extracted at 1.5, 1.9 and 2.3 MeV incident neutron energies. The energy distributions of the prompt fission neutrons and of the inelastically scattered neutrons are given at the incoming neutron energies of 1.5, 1.9 and 2.3 MeV; and the average fission neutron energies and the inelastic neutron evaporation temperatures were also evaluated at these energies.  相似文献   

10.
为获取小角度出射的单能中子源,采用蒙特卡罗软件对小型D-D中子管产生的能量为2.45 MeV的4立体角中子源进行了准直屏蔽结构设计。准直屏蔽结构分为准直器和捕获穴,准直器采用铁+含硼聚乙烯+铅的三层过滤结构,用于屏蔽照射野外杂散中子,捕获穴主要功能是增加反方向中子的弹性散射次数,从而降低出射束低能散射中子的比例。通过MCNP模拟得到了准直器各层材料的最佳厚度和出射孔尺寸以及捕获穴最佳结构。经验证,中子照射野处2.45 MeV的中子通量比照射野外大三个量级,中子照射野处低能中子通量比2.45 MeV的中子通量低一个量级,墙壁外总剂量率(中子+)在2.5 Gy/h以下。该研究对于小角度单能中子源的快速获取具有一定的实用价值,获取的中子源可用于中子剂量仪器有效性检验、中子监测仪性能测试等方面的研究。  相似文献   

11.
Recent developments in accelerator physics have led to new challenges for radiation protection dosimetry. Doses have to be determined for workplace fields which are characterized by high-energy radiation, a dominant contribution from neutrons, high intensities and pulsed time structure This may present problems for active measuring devices. As is well known, the ambient dose equivalent is often underestimated by area monitors operating in high-energy neutron fields behind shielding. Therefore, it is desirable to calibrate survey monitors in a characterized neutron field with the type of spectral fluence distribution that is expected behind shielding, i.e. where the main dose from neutrons arises from two peaks with mean energies of about 1 MeV and 100 MeV, respectively. Such a neutron fluence distribution is produced by the irradiation of a Fe-target with 200 MeV/u 12C-ions. Measurements with the extended range Bonner sphere spectrometer NEMUS of PTB were performed at two positions inside the experimental area Cave A of the heavy-ion synchrotron SIS at GSI. The measured neutron spectra show different fluence contributions for the two peaks at the two positions. The results were compared to Monte Carlo Simulations with MCNPX and FLUKA.  相似文献   

12.
Contemporary linear accelerators applied in radiotherapy generate X-ray and electron beams with energies up to 20 MeV. Such high-energy therapeutic beams induce undesirable photonuclear (γ,n) and electronuclear (e,e'n) reactions in which neutrons and radioisotopes are produced. The originated neutron can also induce reactions such as simple capture, (n,γ), reactions that produce radioisotopes. In this work measurements of the non-therapeutic neutrons and the induced gamma radiation were carried out in the vicinity of a new medical accelerator, namely the Varian TrueBeam. The TrueBeam is a new generation Varian medical linac making it possible to generate the X-ray beams with a dose rate higher than in the case of the previous models by Varian. This work was performed for the X-ray beams with nominal potentials of 10 MV (flattening filter free), 15 MV and 20 MV, and for a 22 MeV electron beam. The neutron measurements were performed by means of a helium chamber and the induced activity method. The identification of radioisotopes produced during emission of the therapeutic beams was based on measurements of the energy spectra of gammas emitted in decays of the produced nuclei. The gamma energy spectra were measured with the use of the high-purity germanium detector. The correlation between the neutron field and the mode and nominal potential was observed. The strongest neutron fluence of 3.1 × 106 cm−2 Gy−1 and 2.0 × 106 cm−2 Gy−1 for the thermal and resonance energies, respectively, was measured during emission of the 20 MV X-ray beam. The thermal and resonance neutron fluence measured for the 15 MV X-rays was somewhat less, at 1.1 × 106 cm−2 Gy−1 for thermal neutrons and 6.7 × 105 cm−2 Gy−1 for resonance neutrons. The thermal and resonance neutron fluences were smallest for the 10 MV FFF beam and the 22 MeV electron beam and were around two orders of magnitude smaller than those of the 20 MV X-ray beam. This work has shown that the neutron reactions are dominant because of relatively high cross sections for many elements used in the accelerator construction. The detailed analysis of the measured spectra made it possible to identify 11 radioisotopes induced during TrueBeam delivery. In this work the following radioisotopes were identified: 56Mn, 122Sb, 124Sb, 131Ba, 82Br, 57Ni, 57Co, 51Cr, 187W, 24Na and 38Cl.  相似文献   

13.
Abstract

The shielding effect of an iron sphere assembly has been tested for a Pu-α-Be neutron source placed in the center of the shield assembly. Emergent neutron and gamma spectra were measured with a stilbene scintillation counter. Discrimination between neutrons and gammas was achieved by the pulse shape discrimination technique based on the zero crossing method. Calculations have been made using the one-dimensional transport code ANISN-Westinghouse version (ANISN-W) and the EUR LiB 15/5 cross section data set. The agreement between measurements and calculations indicates that the cross section set and the calculation model are suitable for studying the iron shielding experiments over the neutron energy range 1.35–10 MeV and the gamma energy range 0.3–6 MeV. Total macroscopic cross sections for fast neutrons, linear attenuation coefficients for gamma rays and half-value thicknesses for neutrons and gammas for the whole energy range and at different energies have been obtained.  相似文献   

14.
The O5R Monte Carlo neutron transport Code had been used to calculate the neutron albedo for neutrons reflected from plane and curved concrete shields. The present calculations were performed to investigate the fast-neutron albedo in case of ordinary concrete shield, in order to perform comparative studies with the case of neutron reflection against a flat wall. The calculations were performed for three different neutron source energies of 1 MeV, 5 MeV and 15 MeV and at neutron incident angles of 5°, 30°, 45°, 60° and 90° and for surfaces with different curvatures (flat, 100, 50, 20 and 5 cm). The results obtained reveal that there will be an appreciable error on using the flat wall albedo value in the case of duct penetration calculations. The error was assumed to be due to the neglection of the curvature effect as well as to the improper choice of the neutron incident angle.  相似文献   

15.
16.
An experiment to measure energetic neutrons and gamma rays in space was launched in the first Indian scientific satellite,Aryobhata, on April 19, 1975. From this experiment, the first measurements in space of the Earth’s albedo fiux of neutrons of energy between 20 and 500 MeV have been made; the values obtained for two mean geomagnetic vertical cut-off rigidities of 5.6 and 17.0 GV are (6.3±0.4)×10−2 and (1.4±0.3)×10−2 neutrons cm−2 sec−1 respectively. These measurements confirm that protons arising from cosmic ray albedo neutron decay, can adequately account for the protons in the inner radiation belt. Observations on gamma rays of energy between 0.2 and 24 MeV have enabled the determination of the total background gamma ray flux in space as a function of latitude. This in turn has permitted useful information on the diffuse cosmic gamma rays. We have also observed four events that showed sudden increases in the gamma ray counting rates between 0.2 and 4.0 MeV. Observational details of these events are given.  相似文献   

17.
A series of experiments has been conducted at the Frank Laboratory of Neutron Physics (FLNP) of the Joint Institute for Nuclear Research (JINR) in order to study the possibility of determining the moisture content of coke using a standard neutron source. The proposed method is based on a measurement of the spectrum of prompt γ rays emitted when samples are irradiated by fast and/or thermal neutrons. The moisture content is determined from the area of the peaks of characteristic γ rays produced in the radiative capture of thermal neutrons by the proton (Eγ = 2.223 MeV) and inelastic scattering of fast neutrons by 16O (Eγ = 6.109 MeV). The 239Pu–Be neutron source (〈E n 〉 ~ 4.5 MeV) with an intensity of ~5 × 106 n/s was used to irradiate the samples under study. A scintillation detector based on a BGO crystal was used to register the characteristic γ radiation from the inelastic fast neutron scattering and slow (thermal) neutron capture. This paper presents the results of humidity measurement in the range of 2–50% [1, 2].  相似文献   

18.
Angular distributions of neutrons elastically and inelastically scattered from238U have been measured with a time-of-flight spectrometer at seven incident neutron energies between 1.5 and 5.5 MeV. Inelastic angular distributions for groups of unresolved levels are given for incoming neutron energies of 1.5, 1.9 and 2.3 MeV. The corresponding neutron cross-sections were obtained relative to then-p scattering cross-sections. The average energies and angular distributions of the fission neutrons were extracted from the measured fission neutron spectra at 1.5,1.9 and 2.3 MeV. Cross-section calculations based on a spherical optical model have shown to be inadequate to describe the neutron-nucleus interaction in case of strong nuclear deformation. The experimental reality may be better approached, instead, if the calculations are made using a potential which takes into account the deformation of the target nucleus. Some of the present measurements are interpreted in this theoretical perspective.  相似文献   

19.
A. Hofmann 《Physics Reports》1980,64(5):253-281
The properties of synchrotron radiation from LEP are investigated. This radiation from LEP are investigated. This radiation is assumed to be in a parasitic mode without changing any of the operating parameters. At 86 GeV the radiation from the normal bending magnet has a critical energy of 0.4 MeV and a power of ~500 W/m, and is probably of limited interest. High photon energies (10–20 MeV) of high intensity can be obtained from normal and superconducting wiggler magnets. Undulators can give quasi-monochromatic radiation of high brightness with photon energies of up to 5 MeV. New magnet developments might increase this energy range. Quasi-monochromatic γ-rays of ~100 MeV can be created with soft Compton back scattering without disturbing the electron bean. This relies on future free electron lasers in the submillimetre range. The natural collimation, the polarization and the time structure make all these photon beams unique tools for research in nuclear physics. The synchrotron rediation can be used to produced photoneutrons with intensities of up to 1014 neutrons/s. It is foreseen that LEP will be equipped with superconducting cavities in later stage and that is energy will be increased to ~130 GeV. This will approximately double the photon energies obtained from wigglers and undulators.  相似文献   

20.
The nanostructure of synthetic quartz samples irradiated with fast reactor neutrons with energies E n > 0.1 MeV has been studied by small-angle neutron scattering. The fluences are varied from 1017 to 2 × 1020 neutrons/cm2. In the quartz samples irradiated with fluences higher than 1017 neutrons/cm2, point, extended (dislocation loops), and volume defects, namely, thermal peaks up to 50 nm in radius, are observed over the entire volume. At a fluence of 2 × 1020 neutrons/cm2, the total fraction of the formed defect regions, where the material is in a noncrystalline state, exceeds 10% of the sample volume. The data on the formation of a metamikt glassy phase in the quartz sample have been obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号