首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Capillary liquid chromatography based on particulate and monolithic stationary phases was used to screen complex peptide libraries by fast gradient elution coupled on-line to electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). A slightly modified commercial electrospray interface consisting of a fused-silica transfer capillary and low dead volume stainless steel union at which the electrospray voltage was grounded enabled the effluent of all the capillary columns to be directly sprayed into the mass spectrometer. Stable electrospray conditions were generated over a wide range of mobile phase compositions, alleviating the need for a tapered end of the spray capillary, pneumatic assistance or preheated nebulizer gas. Since the identification of complex samples containing numerous isobaric substances is facilitated by chromatographic separation prior to mass spectrometry, stationary phase materials have been employed which offer a fast, efficient elution and, due to the complexity of samples, a high loading capacity. Silica-based monolithic capillary columns combine these three characteristics in a unique manner due to a tailored adjustment of both macro- and mesopore sizes in the highly porous silica structure. As we demonstrate by a comparative study of the silica-based monolithic and packed capillaries for LC/MS analysis of complex peptide libraries, silica monoliths show superior performance over packed beds of small-diameter particles with respect to analysis time and separation efficiency. Libraries with more than 1000 different peptides could be screened in less than 20 min.  相似文献   

2.
The components of secondary organic aerosols (SOAs) generated from the gas‐phase ozonolysis of two C10H16‐terpenes (α‐pinene; sabinene) and a cyclic C6H10 alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed‐phase high‐performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well‐known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental compositions were determined. In order to provide additional information for the structural elucidation of these compounds, collision‐induced dissociation was applied. Based on the MS/MS spectra, two higher molecular weight products are proposed to be an ester and a peroxide. Molecular formulae calculated from the exact masses show that the SOA‐compounds are heavily oxidized and this information creates the background to a discussion of potential reaction pathways for the formation of higher molecular weight compounds. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A novel strategy was developed to extend the application of electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) to the analysis of long-chain polysaccharides. High molecular weight polydisperse maltodextrins (poly-alpha(1-4) glucose) and dextrans (poly-alpha(1-6) glucose) were chosen as model compounds in the present study. Increased ionization efficiency of these mixtures in the positive ion mode was achieved upon modification of their reducing end with nitrogen-containing groups. The derivatization method is based on the formation of a new C--N bond between 1,6-hexamethylenediamine (HMD) and the reducing end of the polysaccharide, which exists in solution as an equilibrium between the hemiacetal and the open-ring aldehyde form. To achieve the chemical modification of the reducing end, two synthetic pathways were developed: (i) coupling of HMD by reductive amination and (ii) oxidation of the hemiacetal to lactone, followed by ring opening by HMD to yield the maltodextrin lactonamide of 1,6-hexanediamine (HMMD). Amino-functionalized polysaccharides were analyzed by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FTICR-MS) in the positive ion mode by direct flow injection. The hexamethylenediamine (HMD) and maltodextrin lactonamide of 1,6-hexanediamine (HMMD) moieties provide increased proton affinities which dramatically improve the detection of the long-chain polysaccharides by FTICR-MS. The present approach allowed for identification of single components in mixtures with prominent heterogeneity in the degree of polymerization (DP), without the need for chromatographic separation prior to MS. The high mass accuracy was essential for the unambiguous characterization of the species observed in the analyzed mixtures. Furthermore, molecular components containing up to 42 glucose residues were detected, representing the largest polysaccharide chains analyzed so far by ESI FTICR-MS.  相似文献   

4.
Electrospray ionization (ESI) was performed on a Fourier transform ion cyclotron resonance mass spectrometer for the endgroup and monomer mass determination of three poly(oxyalkylene)s in the mass range of 400–8000 Da. A combined use of the multiple charge states observed with ESI, leads to a threefold increase in accuracy of the endgroup and monomer determination. The improvement is attributed to the increased number of datapoints used for the regression procedure, yielding more accurate results. Endgroup masses are determined with a mass error better than 5 and 75 millimass units for the molecular weight range of 400–4200 and 6200–8000 Da, respectively. A mass error of better than 1 millimass unit was observed for all monomer mass determinations. With ESI, endgroup and monomer masses have been determined for poly(ethylene glycol) oligomers with a mass higher than 8000 Da. This is almost two times higher than observed with matrix-assisted laser desorption/ ionization on the same instrument.  相似文献   

5.
Paeoniflorin standard was first investigated by electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry (ESI-FTICR-MS/MS) using a sustained off-resonance irradiation (SORI) collision-induced dissociation (CID) method at high mass resolution. The experimental results demonstrated that the unambiguous elemental composition of product ions can be obtained at high mass resolution. Comparing MS/MS spectra and the experimental methods of hydrogen and deuterium exchange, the logical fragmentation pathways of paeoniflorin have been proposed. Then, the extracts of the traditional Chinese medicine Paeonia lactiflora Pall. were analyzed by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS). By comparison with the ESI-FTICR-MS/MS data of paeoniflorin, the isomers paeoniflorin and albiflorin in Paeonia lactiflora Pall. have been identified using HPLC/MS with CID in an ion trap and in-source CID. Furthermore, using the characteristic fragmentation pathways, the retention times (t(R)) in HPLC and MS/MS spectra, the structures of three other kinds of monoterpene glycoside compounds have been identified on-line without time-consuming isolation. Thus an HPLC/ESI-MS method for the analysis of constituents in Paeonia lactiflora Pall. has been established.  相似文献   

6.
7.
The internal energy of protonated leucine enkephalin has been manipulated in electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry with two newly designed pump-probe experiments. Blackbody infrared radiation was applied to pump an ion population into a well-defined internal energy distribution below the dissociation threshold. Following this pumping stage, the internal energy distribution was probed using on-resonance collisional activation to dissociate the ions. These pump-probe experiments were carried out in two different ways: (a) using on-resonance collisional activation with variable kinetic energies to dissociate the ions at a constant initial ion temperature (determining the precursor ion survival percentage as a function of kinetic energy) and (b) using on-resonance collisional activation with a constant kinetic energy to dissociate the ions at variable initial ion temperatures (to investigate the ion survival yield-initial ion temperature dependence). Using this approach, a detailed study of the effects of the initial ion temperature, the probing kinetic energy and the internal energy loss rate on the effective conversion efficiency of (laboratory-frame) kinetic energy to internal energy was conducted. This conversion efficiency was found to be dependent on the initial ion temperature. Depending on the experimental conditions the conversion efficiency (for collisions with argon) was estimated to be about 4.0 +/- 1.7%, which agrees with that obtained from a theoretical modeling. Finally, the reconstructed curves of the ion survival yield versus the mode of the (final) total internal energy distribution of the activated ion population (after pump and probe events) at different pump-probe conditions reveal the internal energy content of the activated ions.  相似文献   

8.
Because of poor aqueous solubility and lack of UV chromophores, the characterization of long-chain hydrocarbons and ceramides by conventional UV and mass spectrometric methods has not been successful. Therefore, a novel coaxial electrospray ionization method was developed for characterizing reaction products of phytosphingosine and hexacosanoic acid in toluene and tetrahydrofuran (THF), by high resolving power Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). Simultaneous spraying of a solution of apolar analytes and polar reagents into the gas phase readily enabled protonation and/or sodiation of analyte with enhanced signal-to-noise (S/N). Sample introduction was by direct infusion such that the sprayers were arranged either along the instrument line-of-sight (for monospray and coaxial spray modes) or in a 45 degrees configuration for dual-spray mode. For dual-spray and coaxial spraying, p-toluenesulphonic acid was used as a reagent and sprayed simultaneously with the analyte dissolved in toluene or THF. Compounds were characterized by accurate mass measurement of the protonated and/or sodiated molecules.  相似文献   

9.
The fragmentations of four strychnos alkaloids have been investigated by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS) in the positive ion mode. Experiments using multi-stage tandem mass spectrometry (ESI-FT-ICR-MSn) allowed us to obtain precise elemental compositions of product ions at high mass resolution. The experimental data demonstrated that the nitrogen bridge and the coordinated oxygen atom on the nitrogen bridge in the alkaloid compounds were the active sites in the MS2 fragmentations. The loss of CH3 or the OCH3 group in those alkaloids, which have an OCH3 substituent, was the dominant fragmentation mode in the MS3 fragmentations. Logical fragmentation schemes for strychnos alkaloids have been proposed and these should be useful for the identification of these compounds.  相似文献   

10.
A new ion source has been developed for Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) that enables quick changes between matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) modes. When operating as an ESI source, the sample solution is sprayed through an angled nebulizer. The generated ions pass through a glass capillary followed by a skimmer and three sequential hexapole ion guides. Ions can be accumulated in the third hexapole (storage hexapole) before they are injected into the ICR trap. The second hexapole is mounted on a movable platform which also carries the MALDI sample plate. During the switch from ESI to MALDI, this platform moves the second hexapole out of the hexapole series and locates a MALDI sample plate with 384 sample positions into the area directly in front of the storage hexapole. The storage hexapole is in a medium pressure chamber (MPC) which has windows both for the incoming laser beam and for the observation optics, as well as a gas tube for pulsing collision gas into the chamber. During the MALDI operation the focused laser beam enters the MPC, passes between the hexapole rods and irradiates a MALDI sample on the target plate. The sample molecules are desorbed/ionized into the storage hexapole and simultaneously cooled by collisions with the pulsed gas. Ions desorbed from multiple laser shots can be accumulated in this hexapole before they are transferred to the ICR trap. With the combined ion source a computer-controlled switch between MALDI and ESI modes is possible in less than a minute, depending on the position of the MALDI target on the 384-spot plate. Immediate acquisition of mass spectra is possible after mode switching without the need for tuning or re-calibration.  相似文献   

11.
Characterizing polymerase chain reaction (PCR) amplicons has been accomplished for the first time using flow injection analysis coupled to electrospray ionization mass spectrometry (ESI-MS). The PCR amplicons were amplified at the human tyrosine hydroxylase short tandem repeat locus from an individual homozygotic for the 9.3 allele. One product was amplified using Pfu polymerase and yielded a blunt-ended amplicon of 82 base-pairs (bp) in length. The second PCR product was amplified using Taq polymerase that resulted in an amplicon with cohesive termini of 82 bp plus either mono- or diadenylation. The two PCR amplicons were alternatively injected using a 0.5-microL loop at 2 microM for the Pfu amplicon and 1 microM for the Taq amplicon with a flow rate of 200 nL/min during data acquisition. Both PCR amplicons were accurately identified using mass measurements illustrating the compatibility of ESI-MS for genotyping short tandem repeat sequences and the potential for high-throughput genotyping of large PCR amplicons.  相似文献   

12.
We report the first coupling of a desorption electrospray ionization (DESI) ion source to Fourier transform ion cyclotron resonance mass spectrometry (ESI-FT-ICR-MS) for high-resolution protein analysis. The DESI FT-ICR-MS source design is described in detail along with preliminary data obtained on peptides and proteins ranging from 1 to 5.7 kDa.  相似文献   

13.
In electrospray ionization (ESI) quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry, certain fragment ions (e.g. acylium ions) generated either during the ion transportation process (in the source interface region) or in the ion trap are found to undergo ion--molecule reactions with ESI solvent molecules (water, acetonitrile and aliphatic alcohols) to form adduct species. These unexpected solvated fragment ions severely complicate the interpretation of mass spectrometic data. High-resolution accurate mass measurements are important in establishing the elemental compositions of these adduct species and preventing erroneous data interpretation.  相似文献   

14.
Presented is the application and evaluation of a magnetic field focusing central trapping electrode ion accumulation cell for a capillary liquid chromatography electrospray Fourier transform ion cyclotron (LC-ESI/FTICR) mass spectrometer. The ESI source and accumulation cell are located within the magnetic field to confine the radial motion of the ions, eliminating the need for elaborate focusing optics to transport the ions to the low-pressure analyzer cell for analysis. The central trapping electrode accumulation cell increases sensitivity by providing the necessary potential well in a confined volume to capture ions currently lost during the detection event of LC/FTICR experiments. With this electrode geometry the time needed to gate the ions into the analyzer cell is reduced and pump down delays are minimized. The decreased scan time improves LC resolution and increases the number of mass spectral scans per eluted component while maintaining appropriate base pressures for high performance ESI/FTICR. Results achieved with the central trapping electrode accumulation cell include an effective duty cycle increase from 10% to 40%, a S/N increase by a factor of 30, and a mass resolution increase of 80%.  相似文献   

15.

Editorial

Focus on Fourier transform ion cyclotron resonance mass spectrometry  相似文献   

16.
Electrospray ionization (ESI) in combination with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry provides for mass analysis of biological molecules with unrivaled mass accuracy, resolving power and sensitivity. However, ESI FTICR MS performance with on-line separation techniques such as liquid chromatography (LC) and capillary electrophoresis has to date been limited primarily by pulsed gas assisted accumulation and the incompatibility of the associated pump-down time with the frequent ion beam sampling requirement of on-line chromatographic separation. Here we describe numerous analytical advantages that accrue by trapping ions at high pressure in the first rf-only octupole of a dual octupole ion injection system before ion transfer to the ion trap in the center of the magnet for high performance mass analysis at low pressure. The new configuration improves the duty cycle for analysis of continuously generated ions, and is thus ideally suited for on-line chromatographic applications. LC/ESI FTICR MS is demonstrated on a mixture of 500 fmol of each of three peptides. Additional improvements include a fivefold increase in signal-to-noise ratio and resolving power compared to prior methods on our instrument.  相似文献   

17.
Liquid separation methods in combination with electrospray mass spectrometry as well as the recently introduced fragmentation method electron capture dissociation (ECD) have become powerful tools in proteomics research. This paper presents the results of the first successful attempts to combine liquid chromatography (LC) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with ECD in the analysis of a mixture of standard peptides and of a bovine serum albumin tryptic digest. A novel electron injection system provided conditions for ECD sufficient to yield extensive sequence information for the most abundant peptides in the mixtures on the time-scale of the chromatographic separation. The results suggest that LC/ECD-FTICRMS can be employed in the characterization of peptides in enzymatic digests of proteins or protein mixtures and identify and localize posttranslational modifications.  相似文献   

18.
External ion accumulation in a two-dimensional (2D) multipole trap has been shown to increase the sensitivity, dynamic range and duty cycle of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. However, it is important that trapped ions be detected without significant bias at longer accumulation times in the external 2D multipole trap. With increasing ion accumulation time pronounced m/z discrimination was observed when trapping ions in an accumulation quadrupole. In this work we show that superimposing lower rf-amplitude dipolar excitation over the main rf-field in the accumulation quadrupole results in disruption of the m/z discrimination and can potentially be used to achieve unbiased external ion accumulation with FTICR.  相似文献   

19.
We report the characterization of a recently introduced hybrid ionization source, matrix-assisted laser desorption electrospray ionization (MALDESI), coupled to a quadrupole Fourier transform ion cyclotron resonance mass spectrometry (QFT-ICR-MS) system. We first demonstrate the ability of MALDESI-QFT-ICR MS to directly analyze and provide high mass measurement accuracy (approximately 1 part-per-million) of a polypeptide using internal calibration. Second, we show the potential of MALDESI-QFT-ICR MS for the top-down characterization of multiply charged polypeptide cations. Finally, we demonstrate sub-femtomole detection limits in MALDESI-QFT-ICR MS using a combination of naturally occurring peptides and their respective stable isotope labeled forms. The results presented herein demonstrate the feasibility of several potential applications for MALDESI-QFT-ICR MS for the direct analysis of intact biological molecules.  相似文献   

20.
Capillary liquid chromatography (LC) separation coupled with external accumulation Fourier transform ion cyclotron resonance (FTICR) mass spectrometry has recently been demonstrated to have significant potential for proteomics research. Accumulation of an excessive space charge external to the FTICR cell ion trap has been shown to result in increased mass measurement error, undesirable ion discrimination and/or fragmentation, potentially causing misrepresentation or incorrect assignments of lower abundance peptides in the acquired mass spectra. In this work we report on the capability of data-dependent adjustment of ion accumulation times in the course of LC separations, further referred to as automated gain control (AGC). Three different AGC approaches were evaluated based on the number of putative peptides from a tryptic digest of four casein proteins detected in the course of LC/FTICR separations. When compared with the conventional technique, AGC was found to increase, up to a factor of 3, the total number of peptides identified.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号