首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel sequential injection (SI) method was developed for the determination of penicillamine (PA) and ephedrine (EP) based on the reaction of these drugs with tris(bipyridyl)ruthenium(II) (Ru(bpy)32+) and peroxydisulfate (S2O82−) in the presence of light. Derivatization of PA and EP with aldehydes has resulted in a significant enhancement of the chemiluminescence emission signal by at least 25 times for PA and 12 times for EP, leading to better sensitivities and lower detection limits for both drugs. The instrumental setup utilized a syringe pump and a multiposition valve to aspirate the reagents, (Ru(bpy)32+ and S2O82−), and a peristaltic pump to propel the sample. The experimental conditions affecting the derivatization reaction and the chemiluminescence reaction were systematically optimized using the univariate approach. Under the optimum conditions linear calibration curves between 0.2–24 μg mL−1 for PA and 0.2–20 μg mL−1 for EP were obtained. The detection limits were 0.1 μg mL−1 for PA and 0.03 μg mL−1 for EP. The procedure was applied to the analysis of PA and EP in pharmaceutical products and was found to be free from interferences from concomitants usually present in these preparations.  相似文献   

2.
1H, 13C and 15N NMR spectroscopy has been applied for investigation of amine adducts with rhodium(II) tetraacetate dimer and rhodium(II) tetratrifluoroacetate dimer in CDCl3 solution. Subsequent formation of two adducts, 1:1 and 2:1, was proved by NMR and VIS titration experiments, and by NMR measurements at reduced temperatures, from 233 to 273 K. The adduct formation shift, defined as Δδadductδligand and characterizing complexation reaction, varies from ca. 0 to +1.6 ppm for 1H, from ca. −10 to +6 ppm for 13C and from −4.4 to −39 ppm for 15N NMR. Formation of N–Rh bond slows the inversiof on the nitrogen atom and generates, in the case of N-methyl-(1-phenylethyl)-amine, a nitrogenous chiral center in the molecule. VIS spectra of amine-dirhodium salt mixture contain two bands in the 532–597 nm spectral range, assigned to 1:1- and 2:1-adducts.  相似文献   

3.
An atomic absorption spectrophotometric method for the determination of trace copper after adsorption of its 1-nitroso-2-naphthol-3,6-disulfonic acid chelate on Ambersorb 572 has been developed. This chelate is adsorbed on the adsorbent in the pH range 1–8. The copper chelate is eluted with 5 ml of 0.1 mol l−1 potassium cyanide and determined by flame atomic absorption spectrometry (FAAS). The selectivity of the proposed procedure was also evaluated. Results show that iron(III), zinc(II), manganese(II) and cobalt(II) at the 50 μg l−1 level and sodium(I), potassium(I), magnesium(II), calcium(II) and aluminium(III) at the 1000 μg l−1 level did not interfere. A high enrichment factor, 200, was obtained. The detection limit (3σ) of copper was 0.34 μg l−1. The precision of the method, evaluated by seven replicate analyses of solutions containing 5 μg of copper was satisfactory and the relative standard deviation was 1.7%. The adsorption of copper onto Ambersorb 572 can formally be described by a Langmuir equation with a maximum adsorption capacity of 14.3 mg g−1 and a binding constant of 0.00444 l mg−1. The accuracy of the method is confirmed by analysing tomatoes leaves (NIST 1573a) and lead base alloy (NBS 53e). The results demonstrated good agreement with the certified values. This procedure was applied to the determination of copper in waters (tap, river and thermal waters), aluminium foil and tea samples.  相似文献   

4.
Automated sequential injection (SIA) method for chemiluminescence (CL) determination of nonsteroidal anti-inflammatory drug indomethacin (I) was devised. The CL radiation was emitted in the reaction of I (dissolved in aqueous 50% v/v ethanol) with intermediate reagent tris(2,2′-bipyridyl)ruthenium(III) (Ru(bipy)33+) in the presence of acetate. The Ru(bipy)33+ was generated on-line in the SIA system by the oxidation of 0.5 mM tris(2,2′-bipyridyl)ruthenium(II) (Ru(bipy)32+) with Ce(IV) ammonium sulphate in diluted sulphuric acid. The optimum sequence, concentrations, and aspirated volumes of reactant zones were: 15 mM Ce(IV) in 50 mM sulphuric acid 41 μL, 0.5 mM Ru(bipy)32+ 30 μL, 0.4 M Na acetate 16 μL and I sample 15 μL; the flow rates were 60 μL s−1 for the aspiration into the holding coil and 100 μL s−1 for detection. Calibration curve relating the intensity of CL (peak height of the transient CL signal) to concentration of I was curvilinear (second order polynomial) for 0.1–50 μM I (r = 0.9997; n = 9) with rectilinear section in the range 0.1–10 μM I (r = 0.9995; n = 5). The limit of detection (3σ) was 0.05 μM I. Repeatability of peak heights (R.S.D., n = 10) ranged between 2.4% (0.5 μM I) and 2.0% (7 μM I). Sample throughput was 180 h−1. The method was applied to determination of 1 to 5% of I in semisolid dosage forms (gels and ointments). The results compared well with those of UV spectrophotometric method.  相似文献   

5.
A simple and rapid flow injection (FI) method is reported for the determination of phosphate (as molybdate reactive P) in freshwaters based on luminol chemiluminescence (CL) detection. The molybdophosphoric heteropoly acid formed by phosphate and ammonium molybdate in acidic conditions generated chemiluminescence emission via the oxidation of luminol. The detection limit (3× standard deviation of blank) was 0.03 μg P l−1 (1.0 nM), with a sample throughput of 180 h−1. The calibration graph was linear over the range 0.032–3.26 μg P l−1 (r2=0.9880) with relative standard deviations (n=4) in the range 1.2–4.7%. Interfering cations (Ca(II), Mg(II), Ni(II), Zn(II), Cu(II), Co(II), Fe(II) and Fe(III)) were removed by passing the sample through an in-line iminodiacetate chelating column. Silicate interference (at 5 mg Si l−1) was effectively masked by the addition of tartaric acid and other common anions (Cl, SO42−, HCO3, NO3 and NO2) did not interfere at their maximum admissible concentrations in freshwaters. The method was applied to freshwater samples and the results (26.1±1.1–62.0±0.4 μg P l−1) were not significantly different (P=0.05) from results obtained using a segmented flow analyser method with spectrophotometric detection (24.4±4.45–84.0±16.0 μg P l−1).  相似文献   

6.
Two new coordination polymers of copper(I) chloride and pyrazinic acid (pyz-H), namely [CuCl(pyz-H)2]·2H2O (1) and [Cu2Cl2(pyz)(H2O)]·H2O (2) have been prepared and characterized by spectroscopic, magnetic and crystallographic methods. The overall physical measurements suggest that 1 is diamagnetic and contains monodentate N-pyrazinic acid, whereas 2 is paramagnetic and contains tridentate N,N′,O- chelating bridging pyrazinato anion. In the structure of 1 as elucidated by X-ray single crystal analysis, the asymmetric units [CuCl(pyz)2] are linked together forming a zigzag chain with tetrahedral copper(I) environment. The two lattice water molecules form hydrogen bonds with the uncoordinated N atom and carboxylate group O atom of pyz-H molecules. The Cu–N bond lengths are 2.009(6) Å and Cu–Cl distances are 2.337(2) Å. Complex 2 has a three-dimensional structure with the chains [Cu(I)Cu(II)(C5H3N2O2)Cl2(H2O)] interconnected by [Cu(I)Cl2N] tetrahedral unit and [Cu(II)NO2Cl2] polyhedra. The Cu(I)–Cl and Cu(I)–N distances are 2.327(2)–2.581(2) Å and 1.988(6) Å, respectively, whereas the Cu(II)–Cl and Cu(II)–N bond lengths are 2.258(2), 2.581(2) Å, and 2.017(6) Å, respectively. Hydrogen bonds of the type O–HO are formed between lattice and coordinated water, and carboxylate oxygens of pyrazinato ligand giving rise to a three-dimensional network. The Cl anions act as bridging ligands in both complexes. The magnetic data of complex 2 have been measured from 2 to 300 K and discussed.  相似文献   

7.
Hydrothermal reaction of copper(II) acetate, 2,2′-bipyridine (bipy) and NH4VO3 at 170 °C lead to a new layered polyoxovanadate with organically covalent-bonded copper(II) complex, Cu2(bipy)2V6O17 (1). Cu2(bipy)2V6O17 (1) is a new copper(II) vanadium(V) oxide featuring a new layered architecture, in which the V2O7 dimeric units and the cyclic tetranuclear V4O12 cluster units are interconnected via corner sharing into a unique one-dimensional {V6O17}4− anionic chain, such chains are further bridged by {Cu(bipy)}2+ complex cations into a 010 organic–inorganic hybrid layer.  相似文献   

8.
Jin Pan  Yuming Huang  Weiqun Shu  Jia Cao 《Talanta》2007,71(5):1861-1866
At pHs ≥ 11.45, trace Al was found to enhance the CL from luminol–KMnO4 system. However, at pHs ≤ 10.42, it was found to inhibit strongly the CL from luminol–KMnO4 system. The effect of pH, luminol and potassium permanganate concentrations on the kinetic characteristics of CL system was investigated in the presence of trace Al. On this basis, a flow injection inhibition chemiluminescence method was established for the determination of trace Al in this study. Under optimized conditions, the CL decreased linearly with Al(III) concentration in the range of 8–500 μg L−1 and the detection limit (3σ) of 2 μg L−1. The relative standard deviation (R.S.D.) is 3.6% for 100 μg L−1 Al(III) (n = 11). The method has been applied to the determination of trace Al in real water samples with satisfactory results without the pretreatment of samples. The results given by the proposed method are in good agreement with those given by ICP-AES detection method.  相似文献   

9.
Li B  Zhang Z  Liu W 《Talanta》2001,55(6):1097-1102
A novel chemiluminescence (CL) flow system for the determination of chlortetracycline is described. It is based on the direct CL reaction of chlortetracycline and [Cu(HIO6)2]5− in KOH medium. The unstable [Cu(HIO6)2]5− was on-line electrogenerated by constant-current electrolysis. The CL intensity was linear with chlortetracycline concentration in the range of 0.1–100 μg ml−1. The determination limit was 5.3×10−8 g ml−1. The whole process could be completed in 1 min. The proposed method is suitable for automatic and continuous analysis, and has been applied satisfactorily to analysis of chlortetracycline in biological fluid.  相似文献   

10.
A sequential injection analysis (SIA) system is proposed for the determination of iron (II). Fe(II) was determined by SIA based on the reaction between 1,10-phenanthroline and iron (II), yielding an orange–red colour complex with absorption maximum at 512 nm. The method involved aspiration of 187 μl sample/standard zone followed by a zone of a reagent solution containing 140 μl of 7.8 × 10−4 mol l−1 1,10-phenanthroline into a carrier stream to be stacked inside a holding coil and flow reversed through a reaction coil to a detector. The optimum condition was evaluated and the calibration curve is linear over a range of 0.25 to 5.0 mg l−1 of Fe(II) with detection limit of 18 μg l−1. A sample throughput of 40 h−1 was established. This technique is found to be simple, accurate, reproducible and sensitive. The proposed method was successfully applied for the determination of total iron as Fe(II) in pharmaceutical products (multi-vitamin tablets) and is especially useful for the determination of iron (II) in tablets with lower iron (II) contents. The results were found to be in good agreement with the results obtained by manual UV/Vis spectrophotometry and flame atomic absorption spectrometry (FAAS) and with claimed values by the manufacturers.  相似文献   

11.
Mori I  Kawakatsu T  Fujita Y  Matsuo T 《Talanta》1999,48(5):99-1044
Spectrophotometric determinations of palladium(II) and tartaric acid were respectively investigated by using the color reactions between 2(5-nitro-2-pyridylazo)-5-(N-propyl-N-3-sulfopropylamino)phenol(5-NO2.PAPS) and palladium(II) in strong acidic media, and between 5-NO2.PAPS, niobium(V) tartaric acid in weak acidic media. The calibration graphs were linear in the range of 0–25 μg/10 ml palladium(II), with an apparent molecular coefficient () of 6.2×104 l mol−1 cm−1 at 612 nm, and 0–23 μg/10 ml tartaric acid with =1.08×106 l mol−1 cm−1 at 612 nm, respectively. The proposed methods were selective and sensitive in comparison with other chelating pyridylazo dyes–palladium(II) or metavanadic acid–tartaric acid method, and the effect of foreign ions such as copper(II) was negligible for the assay of palladium(II) with 5-NO2.PAPS.  相似文献   

12.
Norkus E 《Talanta》1998,47(5):759-1301
A potentiometric titration for cobalt(II) determination in the presence of Co(III) based on the oxidation of Co(II) with Na2CrO4 in ethylenediamine medium and back-titration of the oxidant excess with (NH4)2Fe(SO4)2 in acid medium is described. The titration is monitored with a Pt indicator electrode and carried out until the greatest jump of potential from one drop of titrant appears. A RSD smaller than 1.5% has been obtained for 50–300 μmol Co(II). The method proposed was applied in the analysis of a new type electroless copper plating solutions containing Co(II)-ethylenediamine complex compounds as reducing agents. Cu(II), Co(III) and Cr(III) do not interfere in the determination of Co(II).  相似文献   

13.
Bailey BW  Dagnall RM  West TS 《Talanta》1966,13(12):1661-1665
A sensitive spectrofluorimetric procedure for the determination of copper(II) in the range 0.001–0.006 ppm [1–6 × 10−7 g) has been developed, utilising the ternary complex system [Cu(phen)2 Rose Bengal]. The complex is extracted into chloroform, diluted with ammoniacal acetone and its fluorescence measured at 570 mμ with excitation at 560 mμ. The fluorescence is constant for several days. The reaction is rendered selective for copper by a preliminary extraction of bis(2, 9-dimethyl-l, 10-phenanthroline)copper(I) nitrate from an EDTA medium.  相似文献   

14.
Duan H  Liu Z  Liu S  Yi A 《Talanta》2008,75(5):1253-1259
Under the HCl solution and heating condition, penicillin antibiotics such as amoxicillin (AMO), ampicillin (AMP), sodium cloxacillin (CLO), sodium carbenicillin (CAR) and sodium benzylpenicillin (BEN) could react with Fe(III) to produce Fe(II) which further reacted with Fe(CN)63− to form a Fe3[Fe(CN)6]2 complex. By virtue of hydrophobic force and Van der Waals force, the complex aggregated to form Fe3[Fe(CN)6]2 nanoparticles with an average diameter of 45 nm. This resulted in a significant enhancement of resonance Rayleigh scattering (RRS) and non-linear scattering such as second-order scattering (SOS) and frequency doubling scattering (FDS). The increments of scattering intensity (ΔI) were directly proportional to the concentrations of the antibiotics in a certain range. The detection limits for the five penicillin antibiotics were 2.9–6.1 ng ml−1 for RRS method, 4.0–6.8 ng ml−1 for SOS method and 7.4–16.2 ng ml−1 for FDS method, respectively. Among them, the RRS method exhibited the highest sensitivity and the AMO system was more sensitive than other antibiotics systems. Based on the above researches, a new highly sensitive and simple method for the indirect determination of penicillin antibiotics has been developed. It can be applied to the determination of penicillin antibiotics in capsule, tablet, human serum and urine samples. In this work, the spectral characteristics of absorption, RRS, SOS and FDS spectra, the optimum conditions of the reaction and the influencing factors were investigated. In addition, the reaction mechanism was discussed.  相似文献   

15.
A sequential injection analysis (SIA) spectrophotometric method for the determination of trace amounts of zinc(II) with 1-(2-pyridylazo)-2-naphthol (PAN) is described. The method is based on the measurement of absorbance of the zinc(II)–PAN chelate solubilized with a non-ionic surfactant, Triton X-100, no extraction procedure is required in the proposed method, yielding a pink colored complex at pH 9.5 with absorption maximum at 553 nm. The SIA parameters that affect the signal response have been optimized in order to get the better sensitivity and minimum reagent consumption. A linear relationship between the relative peak height and concentration was obtained in the concentration range of 0.1–1.0 μg ml−1. The limit of detection (LOD, defined as 3σ) and limit of quantification (LOQ, defined as 10σ) were 0.02 and 0.06 μg ml−1, respectively. The sample throughput about 40 samples/h was obtained. The repeatability were 1.32 and 1.24% (n = 10) for 0.1 and 0.5 μg ml−1, respectively. The proposed method was successfully applied to the assay of zinc(II) in three samples of multivitamin tablets. The results were found to be in good agreement with those obtained by flame atomic absorption spectrophotometric method and with the claimed values by the manufactures. The t-test showed no significant difference at 95% confidence level.  相似文献   

16.
Ohura H  Imato T  Yamasaki S 《Talanta》1999,49(5):1383-1015
A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3–ClO2 and ClO3–HClO has been developed, using both a redox electrode detector and a Fe(III)–Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2 obtained by the transient potential change were enhanced 700–800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2 is as low as 5×10−8 M with use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3 was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3 was 2×10−6 M with the use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3–ClO2 or ClO3–HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2×10−5–2×10−4 M for ClO3, and 1×10−6–1×10−5 M for HClO and ClO2. The reproducibility of the present method was in the range 1.5–2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3 added to the sample.  相似文献   

17.
A new PVC membrane electrode for Zn2+ ions based on tetra(2-aminophenyl) porphyrin (TAPP) as membrane carrier is prepared. The sensor exhibits a linear stable response over a wide concentration range (5.0×10−5 to 1.0×10−1 M) with a slope of 26.5 mV/decade and a limit of detection 3.0×10−5 M (1.96 ppm). It has a response time of about l0 s and can be used for at least 8 months without any divergence in potential. The propose membrane sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and can be used in pH range of 3.0–6.0. It was successfully applied to the direct determination of zinc in a pharmaceutical sample and also as an indicator electrode in potentiometric titration of Zn2+ ions.  相似文献   

18.
The reaction of 1,2-bis(diphenylthioylphosphino)hydrazine (L) with copper(I) and mercury(II) halides affords the complexes, [{CuLX}2] (X = I, Br or Cl), [HgLX2] (X = Cl or Br) and the tetrametallic complex, [{L(HgI2)2}2]. Single crystal X-ray structures have been performed on the uncoordinated ligand, L, as well as the complexes [{CuLX}2] (X = I, Br and Cl), [HgLBr2] and [{L(HgI2)2}2. The molecules of L exist as dimers as a result of pairs of N–HS hydrogen bonds. The copper(I) complexes are centrosymmetric dimetallic species, the two copper atoms being bridged by L and the X atoms. In all cases the coordination sphere around the Cu atoms is approximately trigonal pyramidal with an ‘S2X2’ donor set. The complex, [HgLBr2], is a distorted tetrahedral monomer with an ‘S2Br2’ donor set and L acting as a bidentate thus forming a seven-membered chelate ring. The tetramercury iodo complex, [{L(HgI2)2}2], contains two ‘L(HgI2)2’ units linked centrosymmetrically via an I atom from each moiety. The geometry around the Hg atoms is distorted tetrahedral. The influence of hydrogen bonding between the hydrazine backbone hydrogens of L and the coordinated halide ions in for the structures of the metal complexes is discussed.  相似文献   

19.
Lin J  Hobo T 《Talanta》1995,42(11):1619-1623
A novel chemiluminescent system, fluorescein-NH(2)OHOH(-), was developed for the determination of copper(II) in serum. A weak light emission arises from hydroxylamine in the presence of the organic reagent fluorescein in basic aqueous solution. Under the conditions of 1.2 x 10(-3) mol l(-1) NH(2)OH and 5 x 10(-3) mol l(-3) fluorescein, the light intensity is linearly dependent upon the concentration of copper(II) within the range 1-20 ppb. The relative standard deviation of the determination of copper(II) is 4.2% (n = 13) and the detection limit is 0.5 ppb. The system is highly selective for copper except in the presence of iron(II,III) and cobalt(II). In conjunction with potassium fluoride as masking agent, the method was successfully applied to the determination of microamounts of copper(II) in serum. A mechanistic study of the chemiluminescence reaction is also discussed.  相似文献   

20.
Li Liu  Jun-feng Song  Peng-fei Yu  Bin Cui 《Talanta》2007,71(5):1842-1848
A novel voltammetric method for the determination of β-d-glucose (GO) is proposed based on the reduction of Cu(II) ion in Cu(II)(NH3)42+–GO complex at lanthanum(III) hydroxide nanowires (LNWs) modified carbon paste electrode (LNWs/CPE). In 0.1 mol L−1 NH3·H2O–NH4Cl (pH 9.8) buffer containing 5.0 × 10−5 mol L−1 Cu(II) ion, the sensitive reduction peak of Cu(II)(NH3)42+–GO complex was observed at −0.17 V (versus, SCE), which was mainly ascribed to both the increase of efficient electrode surface and the selective coordination of La(III) in LNW to GO. The increment of peak current obtained by deducting the reduction peak current of the Cu(II) ion from that of the Cu(II)(NH3)42+–GO complex was rectilinear with GO concentration in the range of 8.0 × 10−7 to 2.0 × 10−5 mol L−1, with a detection limit of 3.5 × 10−7 mol L−1. A 500-fold of sucrose and amylam, 100-fold of ascorbic acid, 120-fold of uric acid as well as gluconic acid did not interfere with 1.0 × 10−5 mol L−1 GO determination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号