首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
孙慧婧  崔冬妮 《应用化学》2022,39(3):470-479
采用同位素稀释结合固相萃取对水样进行预处理,建立了环境水体中涕灭威及其代谢物(涕灭威亚砜、涕灭威砜)的超高效液相色谱-串联质谱分析方法.水样加同位素内标涕灭威-D3、涕灭威亚砜-D3和涕灭威砜-D3,经HLB固相萃取柱富集净化后,用Waters ACQUITYTM BEH C18色谱柱(2.1 mm×100 mm,1....  相似文献   

2.
An element-specific detection method, based on atomic absorption spectrometry (AAS) using solar blind photocells instead of a dispersion system, is described for the determination of Hg-, As-, and Se-species. Spectrometric investigations of AAS background lamps for As and Se measured with a CsI-cathode photocell shows its quality as narrow band detector. Species determination can be carried out subsequently to prior separation by HPLC or GC. The LODs for alkylated Hg species were below 1 ng/L, and for methylated As species below 1 microg/L. The relative standard deviation was < 10%. With the components described the production of cheap and automated dedicated speciation spectrometers is possible.  相似文献   

3.
马立利  贾丽  周欣燃  刘艳  范筱京  潘灿平 《色谱》2014,32(6):635-639
建立了多壁碳纳米管滤过型净化柱净化-超高效液相色谱/串联质谱联用技术同时测定生姜中涕灭威及其代谢物的分析方法。生姜样品经乙腈提取后,用多壁碳纳米管滤过型净化柱进行2次反复抽提净化,净化液用氮气吹干,用乙腈-水(5:95,v/v)溶解,采用正离子多反应监测(MRM)模式进行分析,外标法定量。结果表明:涕灭威、涕灭威砜及涕灭威亚砜在0.5~200 μg/L浓度范围内呈线性,其相关系数(r2)均大于0.99;在2、20、200 μg/kg添加水平下,回收率为71.4%~89.8%,相对标准偏差范围为0.7%~13.2%;3种目标物的定量限为1.0~2.0 μg/kg。本方法操作简单,灵敏度、准确度和精密度均满足农药多残留检测技术的要求,适用于生姜中涕灭威及其代谢物残留的快速测定。  相似文献   

4.
Analysis of caffeine and its metabolites is of interest with respect to caffeine exposure, for kinetic and metabolism studies and for opportunistic in vivo estimation of drug metabolizing enzyme activity in humans and animals. For the latter, analysis is usually done by high-performance liquid chromatography (HPLC) with UV detection. However, this method is close to the detection limit for certain of the metabolites and requires very long chromatography, 30-60 min. We have developed a fast method for the quantification of caffeine and its metabolites 1-methylxanthine, 1-methyluric acid, 1,7-dimethyluric acid, 5-acetylamino-6-amino-3-methyluracil (AAMU) and 5-acetylamino-6-formylamino-3-methyluracil (AFMU) by HPLC tandem mass spectrometry (MS/MS) in urine that requires only its dilution with buffer and centrifugation before injection into the HPLC/MS/MS system. The chromatography lasts 7 min and is followed by 4.5 min for re-equilibration of the HPLC column, giving a total analysis time of 11.5 min. The method provides a great sensitivity improvement with detection limits for all analytes 相似文献   

5.
An element-specific detection method, based on atomic absorption spectrometry (AAS) using solar blind photocells instead of a dispersion system, is described for the determination of Hg-, As-, and Se-species. Spectrometric investigations of AAS background lamps for As and Se measured with a CsI-cathode photocell shows its quality as narrow band detector. Species determination can be carried out subsequently to prior separation by HPLC or GC. The LODs for alkylated Hg species were below 1 ng/L, and for methylated As species below 1 μg/L. The relative standard deviation was < 10%. With the components described the production of cheap and automated dedicated speciation spectrometers is possible. Received: 18 May 1999 / Revised: 6 September 1999 / Accepted: 13 September 1999  相似文献   

6.
刘菁华  孙振中  黄雪玲  郭霞  孙建华 《色谱》2015,33(4):434-440
建立了养殖水体及沉积物中11种磺胺化合物的高效液相色谱-柱后衍生分析方法。养殖水体过滤后采用HLB固相萃取柱进行净化、富集;沉积物采用甲醇/EDTA-Mcllvaine缓冲液(1:1, v/v)提取,HLB固相萃取柱净化富集。经高效液相色谱分离,用荧光胺衍生试剂进行柱后衍生,荧光检测器检测。对柱后衍生系统参数进行了优化,确定了荧光胺溶液的浓度、流速和反应温度分别为0.2 g/L、0.15 mL/min和50 ℃,磺胺化合物在0.01~1.0 mg/L范围内线性显著,其相关系数r2值大于0.99995。11种磺胺类药物在养殖水体和沉积物中的加标回收率分别为79.3%~100.7%和74.6%~95.3%,相对标准偏差为2.2%~11.0%和2.6%~10.3%,检出限(LOD, S/N=3)为0.9~5.5 ng/L和0.3~1.3 μg/kg,定量限(LOQ, S/N=10)为3.0~18.1 ng/L和1.0~4.4 μg/kg。该法可应用于养殖环境中磺胺类药物的定性定量检测,具有较好的实用性。  相似文献   

7.
Yang X  Li P  Zhao Y  Wu Y 《色谱》2012,30(3):309-313
建立了花生中涕灭威及其代谢物涕灭威砜、涕灭威亚砜的高效液相色谱-线性离子阱三级质谱分析方法。样品经环己烷饱和的乙腈提取,凝胶渗透色谱净化后,用高效液相色谱-线性离子阱三级质谱法对样品中的目标物进行定性确证和定量分析。在Capcell PAK CR色谱柱上以含5 mmol/L NH4Ac-HAc的乙腈为流动相进行梯度洗脱分离。采用电喷雾离子源正离子模式进行三级选择离子监测,以涕灭威-d3作为3个目标物的内标物。通过比较基质匹配曲线和纯溶剂标准曲线计算回收率评估基质效应。方法的线性范围为10~500 μg/L,检出限为4~5 μg/kg。涕灭威、涕灭威砜、涕灭威亚砜在3个加标水平(10、20、40 μg/kg)的回收率为81.5%~115%,相对标准偏差为6.35%~15.1%。应用该方法对花生样品进行了测定,结果令人满意。  相似文献   

8.
Abstract

A simplified method for the determination of aldicarb and its oxidation products, aldicarb sulfoxide, and aldicarb sulfone, in water has been developed. Aldicarb and its metabolites are adsorbed on Amberlite XAD-2 polymer resin and then eluted with acetone. The eluate is analyzed for aldicarb and aldicarb sulfoxide by high performance liquid chromatography (HPLC) with UV detection at 254 nm. Total aldicarb residues can be determined by a colorimetric method. Typical detection limits in drinking water are 1 μg/1.  相似文献   

9.
The unique selectivities which can be generated through optimization of stationary/mobile phase combinations have been applied to the development of an isocratic, reversed-phase high-performance liquid chromatographic method for the separation of aldicarb and its primary soil degradation products. The method utilizes a cyanopropyl bonded stationary phase and water-acetonitrile mobile phase and is capable of separating aldicarb and its various sulfoxide, sulfone and oxime derivatives in less than 10 min. When combined with multiple-wavelength UV detection and an appropriate preconcentration step, this method can in principle be applied to the routine monitoring of aldicarb and its soil derivatives in water at concentrations less than 1 microgram/l.  相似文献   

10.
A novel, sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry) method with on-line extraction and clean-up for the screening and confirmation of residues of tetracyclines in kidney has been developed. After liquid extraction of homogenised kidney with McIlvain buffer, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization followed by multiple reaction monitoring. For each tetracycline the collisional decomposition of the protonated molecule to a unique, abundant fragment ion was monitored. The method has been validated for tetracycline, oxytetracycline, chlortetracycline and doxycycline. Calibration curves resulting from spiked blank kidney samples at the 100-1200 microgram/kg level showed good linear correlation. At the level of 600 microgram/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 7%. The limits of detection (LODs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 18, 23, 24 and 21 microgram/kg, respectively. The limits of quantification (LOQs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 36, 46, 47 and 42 microgram/kg, respectively. The recoveries ranged from 71 to 91%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of tetracyclines in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

11.
Peptides containing a free alpha- or epsilon-amino group react with fluorescamine under mild alkaline conditions to generate a highly fluorescent but unstable reaction product and, consequently, practical high-performance liquid chromatographic (HPLC) approaches to analysis have typically involved the use of postcolumn derivatization. An automated precolumn approach is reported in which peptides are reacted with fluorescamine just prior to HPLC analysis by a commercially available autoinjector with derivatization capabilities. The autoinjector added base and fluorescamine reagent solutions to a sample vial containing peptide analytes, and the derivatization reaction was allowed to proceed for 5 min at room temperature prior to injection into the HPLC system. The derivatized peptides were analyzed by reversed-phase HPLC with fluorescence detection (excitation at 390 nm; emission 470-nm cut-off filter) on an octylsilica column. Optimization of the precolumn reaction conditions and the use of narrower HPLC columns (2 mm I.D.) resulted in a typical on-column detection limit of 30-50 fmol of peptide, which was substantially lower than that in previously reported post-column methods. This approach was applied to the HPLC of several naturally occurring and synthetic peptides containing alpha- and epsilon-amino groups. In combination with solid-phase extraction, prior to automated precolumn fluorescence derivatization and chromatographic analysis, the methodology was used for the determination of a synthetic growth hormone-releasing peptide in plasma samples.  相似文献   

12.
Simultaneous dispersive liquid-liquid microextraction (DLLME) and derivatization combined with gas chromatography-electron-capture detection (GC-ECD) was used to determine chlorophenols (CPs) in water sample. In this derivatization/extraction method, 500 microL acetone (disperser solvent) containing 10.0 microL chlorobenzene (extraction solvent) and 50 microL acetic anhydride (derivatization reagent) was rapidly injected by syringe in 5.00 mL aqueous sample containing CPs (analytes) and K(2)CO(3) (0.5%, w/v). Within a few seconds the analytes derivatized and extracted at the same time. After centrifugation, 0.50 microL of sedimented phase containing enriched analytes was determined by GC-ECD. Some effective parameters on derivatization and extraction, such as extraction and disperser solvent type and their volume, amount of derivatization reagent, derivatization and extraction time, salt addition and amount of K(2)CO(3) were studied and optimized. Under the optimum conditions, enrichment factors and recoveries are in the range of 287-906 and 28.7-90.6%, respectively. The calibration graphs are linear in the range of 0.02-400 microg L(-1) and limit of detections (LODs) are in the range of 0.010-2.0 microg L(-1). The relative standard deviations (RSDs, for 200 microg L(-1) of MCPs, 100 microg L(-1) of DCPs, 4.00 microg L(-1) of TCPs, 2.00 microg L(-1) of TeCPs and PCP in water) with and without using internal standard are in the range of 0.6-4.7% (n=7) and 1.7-7.1% (n=7), respectively. The relative recoveries of well, tap and river water samples which have been spiked with different levels of CPs are 91.6-104.7, 80.8-117.9 and 83.3-101.3%, respectively. The obtained results show that simultaneous DLLME and derivatization combined with GC-ECD is a fast simple method for the determination of CPs in water samples.  相似文献   

13.
An automated, environmentally friendly, simple, selective, and sensitive method was developed for the determination of ten primary aliphatic amines in sewage sludge at μg/kg dry weight (d.w.). The procedure involves a pressurized hot water extraction (PHWE) of the analytes from the solid matrix, followed by a fully automated on‐fiber derivatization with 2,3,4,5‐pentafluorobenzaldehyde (PFBAY) and headspace solid‐phase microextraction (HS‐SPME) and subsequent gas chromatography ion‐trap tandem mass spectrometry (GC‐IT‐MS‐MS) analysis. The limits of detection (LODs) of the method were between 0.5 and 45 μg/kg (d.w.) for all compounds except for ethyl‐, isopropyl‐, and amylamine, whose LODs were 70, 109, and 116 μg/kg (d.w.), respectively. The limits of quantification (LOQs) were between 10 and 350 μg/kg (d.w.). Repeatability and intermediate precision, expressed as RSD(%) (n=3), were lower than 18 and 21%, respectively. The method developed enabled to determine primary aliphatic amines in sludge from various urban and industrial sewage treatment plants as well as from a potable treatment plant. Most of the primary aliphatic amines were found in the sewage sludge samples analyzed corresponding to the maximum concentrations to the samples from the urban plant: for instance, isobutylamine and methylamine were found at 7728 and 12 536 μg/kg (d.w.), respectively. Amylamine was detected only in few samples but always at concentrations lower than its LOQ.  相似文献   

14.
We have developed a highly sensitive and positively charged precolumn derivatization reagent, (5‐N‐succinimidoxy‐5‐oxopentyl)triphenylphosphonium bromide (SPTPP), for amines and amino acids in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS). The handling of the derivatization reaction is quite simple and the reagent reacts with the analytes rapidly and with high efficiency. The derivatized analytes were observed to form regular and intense product ions upon MS/MS analysis; thus, highly sensitive and selective detection was possible in the selected reaction monitoring (SRM) mode. The limits of detection of the SPTPP‐derivatized analytes were less than sub‐femtomole levels. The sensitivities of the derivatized analytes increased about 500‐fold compared to those of underivatized analytes. Since the hydrophobicities of the samples increased after their derivatization, the resolution of the analytes improved dramatically when a reversed‐phase system was used. The relative standard deviations of intra‐day and inter‐day variations were below 10.6% and 13.3%, respectively. The accuracy ranged between 86.6–113% and 83.4–113%, respectively. Furthermore, the developed reagent was used for the analysis of the neurotransmitter 4‐aminobutanoic acid (GABA) and oxidative stress markers such as oxidized, nitrated, and halogenated tyrosines in rat serum. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Summary Aldicarb, aldicarb sulfoxide, and aldicarb sulfone were chromatographed on an octyl-silica bonded-phase column and on an unmodified silica column using acetonitrile/water mobile phases. The elution order of the analytes from the silica column was different from that using the octyl-silica bonded phase and allowed confirmation of residues of aldicarb sulfoxide in citrus nectar. Isocratic elution of the unmodified silica column allowed rapid sample throughput.  相似文献   

16.
刘珺  弓振斌 《色谱》2012,30(6):624-629
建立了在线光化学衍生、荧光检测、高效液相色谱(HPLC)测定辣椒油中苏丹红I、II、III和B的方法。以乙腈-水为流动相,采用梯度洗脱方式在SB-C18色谱柱上分离。用实验室自制的程序控制时间/光强光化学反应器作为在线衍生装置,优化了光衍生反应的条件和荧光检测条件。3种不同加标浓度下,辣椒油样品中4种苏丹红染料的加标回收率为81.3%~100.4%。加标水平为0.8 mg/kg下荧光信号强度的相对标准偏差(RSD,n=6)为2.6%~3.8%。苏丹红I、II、III和B的检出限(LOD)和定量限(LOQ)范围分别为0.009~0.054 mg/kg和0.030~0.181 mg/kg,优于传统的HPLC分离、二极管阵列检测器检测方法。该方法具有简单、灵敏、选择性好的特点,适用于食品样品中苏丹红的常规分析。  相似文献   

17.
A simple and rapid HPLC method with UV and fluorescence detection (FLD) for the separation of ten phenolic compounds including gallic acid, catechin, epicatechin, caffeic acid, coumaric, trans-piceid, cis-piceid, trans-resveratrol, cis-resveratrol and quercetin is reported. The UV and fluorescence detector in series provided a high selectivity for the determination of these compounds. Precisions, recoveries and LODs achieved for all the analytes were satisfactory. The proposed method was applied to the determination of these compounds in commercially available red wines.  相似文献   

18.
We developed an isotopic dilution high-performance liquid chromatography (HPLC)/tandem mass spectrometer (MS/MS) method to rapidly and accurately quantify nine metabolites of several classes of pesticide in 1 mL human urine specimens. The analytes covered in the method are two organophosphate (OP) pesticide metabolites: 3,5,6-trichloro-2-pyridinol (TCPy), 2-isopropyl-6-methyl-4-pyrimidinol (IMPY); three synthetic pyrethroid metabolites: 3-phenoxy benzoic acid (3-PBA), 4-fluoro-3-phenoxybenzoic acid (4-F-3-PBA) and trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-1(1-cyclopropane) carboxylic acid (t-DCCA); three herbicide metabolites: 2,4-dichlorophenoxyacetic acid (DCPAA), 2,4,5-trichlorophenoxyacetic acid (TCPAA) and atrazine mercapturate; and one insect repellent: N,N-diethyl-meta-toluamide (DEET). The analytes are first deconjugated by incubating with acetate/β-glucuronidase buffer at 37°C for 17 h. The deconjugated analytes are extracted and concentrated from the urine matrix using solid-phase extraction cartridges, separated through C18 reversed phase HPLC, and analysed on MS/MS. The MS/MS was operated in positive and negative electrospray ionisation switch mode. Two ions from each analyte and one from each labelled internal standard are monitored for quantification and confirmation. The limit of detections (LODs) for all the analytes are in the low parts-per-trillion (0.05 ng/mL) except TCPy where it was 0.5 ng/mL) with a wide linear range (0.05 up to 40 ng/mL) and provides high accuracy (recoveries: 90–118%) and high precision (coefficient of variation <15%). The method accuracy was also verified by the analysis of proficiency testing urine samples. We analysed 101 urine samples for a recent California study cohort, and detection frequencies ranged from ~100% to 0%: 3-PBA (98%), IMPY (91%), TCPy, (89%), DCPAA (66%), 4-F-3-PBA (11%), TCPAA (0%).  相似文献   

19.
HPLC was coupled with sequential injection (SI) for simultaneous analyses of some heavy metals, including Co(II), Ni(II), Cu(II), and Fe(II). 2-(5-Nitro-2-pyridylazo)-5-[N-propyl-N-(3-sulfopropyl)amino]phenol (nitro-PAPS) was employed as a derivatizing reagent for sensitive spectrophotometric detection by online precolumn derivatization. The SI system offers an automated handling of sample and reagent, online precolumn derivatization, and propulsion of derivatives to the HPLC injection loop. The metal-nitro-PAPS complexes were separated on a C(18)-muBondapak column (3.9x300 mm(2)). Using the proposed SI-HPLC system, determination of four metal ions by means of nitro-PAPS complexes was achieved within 13 min in which the parallel of derivatization and separation were processed at the same time. Linear calibration graphs were obtained in the ranges of 0.005-0.250 mg/L for Cu(II), 0.007-1.000 mg/L for Co(II), 0.005-0.075 mg/L for Ni(II), and 0.005-0.100 mg/L for Fe(II). The system provides means for automation with good precision and minimizing error in solution handling with the RSD of less than 6%. The detection limits obtained were 2 microg/L for Cu(II) and Co(II), and 1 microg/L for Ni(II) and Fe(II). The method was successfully applied for the determination of metal ions in various samples, including milk powder for infant, mineral supplements, local wines, and drinking water.  相似文献   

20.
Photocatalytic properties of fibers containing TiO2 nanoparticles were explored for use as a self-decontaminating material using degradation of the pesticide aldicarb as the model toxin. During the analysis of the aldicarb treated sample by liquid chromatography (LC) with diode array detector (DAD), an unidentified peak was found at relative retention time (RT) 3.9 min when compared to aldicarb and major metabolites, aldicarb sulfoxide, and aldicarb sulfone. An analytical method was developed to confirm and identify this degradation product. LC–APCI/MS techniques were used first to analyze molecular ions and major fragments comparing retention times and spectra with those of known standards. FTIR and LC–MS/MS techniques were used to confirm the identity of the degradation product as 2-propenal, 2-methyl-, O-[(methylamino)carbonyl]oxime.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号