 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, reliable and reproducible method, based on capillary zone electrophoresis with amperometric detection, has been developed for the determination of idarubicin in human urine. A carbon disk electrode was used as working electrode. The optimal conditions of separation and detection were pH 5.6 phosphate buffer ¶(0.20 mol/L), 22 kV for the separation voltage and 1.00 V (vs. Ag/AgCl, 3 mol/L KCl) for the detection potential. The linear range was from 4.0 × 10–7 to 2.0 × 10–5 mol/L with a regression coefficient of 0.9986, and the detection limit was 8.0 × 10–8 mol/L. The method was directly applied to the determination of idarubicin in spiked human urine without any other sample pretreatment except filtration, and the assay results were satisfactory.  相似文献   

2.
Jin W  Dong Q  Yu D  Ye X 《Electrophoresis》2000,21(8):1535-1539
Capillary zone electrophoresis was employed for the determination of myoglobin in human urine using end-column amperometric detection with a carbon fiber microelectrode at a constant potential of 1.80 V vs. saturated calomel electrode (SCF). The optimum conditions of separation and detection are: 3.73 x 10-4 mol/L sodium diethyl malonyl urea (barbitone sodium), 1.34 x 10-4 mol/L HCl for the buffer solution, 20 kV for separation voltage, 5 kV and 5 s for injection voltage and injection time, respectively. The limit of detection is 4.4 x 10-8 mol/L or 84 amole signal to noise (S/N = 2). The relative standard deviation is 2.9% for the migration time and 2.5% for the electrophoretic peak current. The method can be used for the determination of myoglobin in human urine. The samples can be directly injected and need no pretreatment. The method is also rapid, less than 2 min, and has a recovery rate of 94-106%.  相似文献   

3.
Jin W  Xu Q  Li W 《Electrophoresis》2000,21(7):1415-1420
Capillary zone electrophoresis was employed for the determination of clozapine using an end-column amperometric detection at a carbon fiber array microdisk electrode with simplified capillary/electrode alignment. The optimum conditions of separation and detection are: Britton-Robinson buffer, pH 2.0 (1.3 x 10(-2) mol/L total concentration of acids, 3.2 x 10(-3) mol/L NaOH), 15 kV for separation voltage, 5 kV and 10 s for injection voltage and injection time, respectively. The limit of detection is 4.2 x 10(-7) mol/L or 1.2 fmole (signal to noise, S/N = 2). The relative standard deviation is 1.4% for the migration time and 2.5% for the electrophoretic peak current. The method was applied to the determination of clozapine in human blood. The recovery of the method is between 94-104%.  相似文献   

4.
A new and sensitive method for the determination of norepinephrine (NE), synephrine, and isoproterenol was developed by CE separation and indirect electrochemiluminescence detection (ECL) based on their quenching effects on the tris(2,2'-bipyridyl)-ruthenium(II)/tripropylamine (TPA) system. The conditions for CE separation and ECL detection were investigated in detail. Under the optimum conditions, the three analytes were well separated within 9 min. The LODs (S/N = 3) in standard solution are 2.6 x 10(-8) mol/L for NE, 6.6 x 10(-9) mol/L for synephrine and 8.4 x 10(-8) mol/L for isoproterenol, respectively. The precisions of intraday and interday are less than 4.4 and 6.1%, respectively. The LOQs (S/N = 10) in real human urine samples are 2.6 x 10(-7) mol/L for NE, 8.8 x 10(-8 ) mol/L for synephrine, and 8.8 x 10(-7) mol/L for isoproterenol, respectively. The applicability of the proposed method was illustrated in the determination of 20 human urine samples from diabetic patients and healthy persons. The results obtained indicated that the level of NE in patients (mean value 0.41 micromol/L) was higher than that in healthy persons (mean value 0.24 micromol/L).  相似文献   

5.
Liu YM  Cao JT  Tian W  Zheng YL 《Electrophoresis》2008,29(15):3207-3212
A novel method for the determination of norfloxacin (NOR) and levofloxacin (LVX) was developed by CE separation and electrochemiluminesence detection (ECL). The methods for capillary conditioning and the effect of solvent type were studied. Parameters affecting the CE and ECL were also investigated. Under the optimum conditions, the two analytes were well separated within 9 min. The LODs (S/N = 3) in standard solution are 4.8 x 10(-7) mol/L for NOR and 6.4 x 10(-7) mol/L for LVX, respectively. The precisions of intraday and interday are less than 4.2 and 8.1%, respectively. The LOQs (S/N = 10) in real human urine samples are 1.2 x 10(-6) mol/L for NOR and 1.4 x 10(-6) mol/L for LVX, respectively. The applicability of the proposed method was illustrated in the determination of NOR and LVX in human urine samples and the monitoring of pharmacokinetics for NOR. The recoveries of NOR and LVX at different levels in human urine samples were between 84.3 and 92.3%.  相似文献   

6.
Jin W  Li W  Xu Q  Dong Q 《Electrophoresis》2000,21(7):1409-1414
Capillary zone electrophoresis was employed for the determination of metronidazole using end-column amperometric detection with a gold microelectrode at a constant potential of -0.52V vs. saturated calomel electrode. To overcome interference of oxygen in the solution, a deaeration injector and a deaeration protector at the detection cell were used. The optimum conditions of separation and detection are 1.0 x 10(-3) mol/L potassium dihydrogen citrate (KH2C6H5O7) for the buffer solution, 20 kV for the separation voltage, and 5 kV and 10 S for injection voltage and injection time, respectively. The limit of detection is 6.0 x 10(7) mol/L or 0.78 fmole (S/N = 3). The relative standard deviation is 3.9% for the electrophoretic peak current. The method was applied to the determination of metronidazole in human urine.  相似文献   

7.
Dong Q  Yu D  Ye X  Jin W 《Electrophoresis》2001,22(1):128-133
Capillary zone electrophoresis was employed for the determination of human serum transferrin using end-column amperometric detection with a carbon fiber microelectrode at a constant potential of 1.9 V vs. saturated calomel electrode (SCE). The optimum conditions of separation and detection are 7.5 x 10(-4) mol/L Tris-3.44 x 10(-4) mol/L HCl for the buffer solution, 20 kV for the separation voltage, 5 kV and 10 s for the injection voltage and the injection time, respectively. The limit of detection is 6.7 x 10(-8) mol/L or 440 amol (S/N = 2). The relative standard deviations are 0.67% for the migration time and 1.5% for the electrophoretic peak current. The method was applied to the determination of transferrin in human serum. The recovery is between 93-104%.  相似文献   

8.
M Jin  Q Dong  R Dong  W Jin 《Electrophoresis》2001,22(13):2793-2796
Capillary zone electrophoresis was employed for the determination of pyruvate in human sweat using electrochemical detection with a carbon fiber microdisk bundle electrode at a constant potential of 1.60 V vs. saturated calomel electrode. The optimum separation conditions are 3.6 x 10(-3) mol/L Na2HPO4-1.4 x 10(-3) mol/L NaH2PO4 (pH 7.2) for the buffer solution, and 18 kV for the separation voltage. The limits of detection of pyruvate are 8.0 x 10(-6) mol/L or 24 fmol (S/N = 3) for the injection voltage of 6 kV and the injection time of 10 s. The relative standard deviation is 2.0% for the migration time and 5.7% for the electrophoretic peak current. The method was applied to determining pyruvate in human sweat.  相似文献   

9.
Capillary zone electrophoresis was employed for the determination of diclofenac sodium using an end-column amperometric detection with a carbon fiber microelectrode, at a constant potential of 0.83 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 4.90 x 10(-3) mol/l Na2HPO4-3.10 x 10(-3) mol/l NaH2PO4 (pH 7.0) for the buffer solution, 10 kV for the separation voltage, 5 kV and 10 s for the injection voltage and the injection time, respectively. The limit of detection is 2.5 x 10(-6) mol/l or 5.2 fmol (S/N=2). The relative standard deviation is 0.8% for the migration time and 4.7% for the electrophoretic peak current. The method was applied to the determination of diclofenac sodium in human urine.  相似文献   

10.
Jin W  Yu D  Dong Q  Ye X 《Electrophoresis》2000,21(5):925-929
Capillary zone electrophoresis was employed for the determination of pipemidic acid using an end-column amperometric detection with a carbon fiber microdisk array electrode, at a constant potential of -1.10 V vs. saturated calomel electrode. The optimum conditions of separation and detection were 1.2 x 10(-4) mol/LNaOAc - 8.8 x 10(-4) mol/ LHOAc for the buffer solution, 20 kV for the separation voltage, 5 kV and 10 s for the injection voltage and the injection time. The limit of detection was 1.05 x 10(-7) mol/L or 189 amol (S/N=3). The relative standard deviation was 0.31% for the migration time and 2.0% for the electrophoretic peak current. The method was applied to determining pipemidic acid in human serum.  相似文献   

11.
采用电聚合方法在石墨烯纳米片(GN)的表面聚合一层聚对氨基苯磺酸(PABSA),制备了聚对氨基苯磺酸/石墨烯复合修饰玻碳电极(PABSA/GN/GCE)。研究了尿酸(UA)和抗坏血酸(AA)在该修饰电极上的电化学行为。与聚对氨基苯磺酸修饰电极(PABSA/GCE)及石墨烯单层膜修饰电极(GN/GCE)相比,复合修饰电极PABSA/GN/GCE显著提高了对UA和AA的检测灵敏度和分离度。在0.1 mol/L磷酸盐缓冲溶液(pH7.0)中,UA和AA的峰电位差达344 mV,表明PABSA/GN/GCE能实现对UA的选择性测定。UA的峰电流与其浓度呈良好的线性关系,线性范围为1.0×10-7~8.0×10-4mol/L,检出限为4.5×10-8mol/L。该复合修饰电极用于尿样中尿酸的测定,结果满意。  相似文献   

12.
Liu YM  Wang CQ  Mu HB  Cao JT  Zheng YL 《Electrophoresis》2007,28(12):1937-1941
A rapid and sensitive method to detect three catecholamines, isoprenaline, epinephrine, and dopamine, by CE coupled with direct luminol-potassium periodate chemiluminescence (CL) detection is described. The conditions for CE separation and CL reaction were systematically optimized. Under the optimum conditions, the baseline separation of three catecholamines was achieved within 6.5 min. The LODs obtained in standard solution were 5.3 x 10(-8 )mol/L for isoprenaline, 4.7 x 10(-8 )mol/L for epinephrine, and 1.5 x 10(-7 )mol/L for dopamine. The RSD of the migration time and peak area were less than 1.8 and 3.6% (n = 5), respectively. The present method was applied to the determination of the dopamine in urine samples of cigarette smokers and nonsmokers. The results obtained indicate that there is a close relationship between the content of dopamine in human urine and the amount of cigarettes smoked daily; the level of dopamine in smokers is higher than in nonsmokers.  相似文献   

13.
A voltammetric determination of adriamycin (ADM) at a carbon paste electrode (CPE) in the presence of cetyltrimethylammonium bromide (CTAB) is described. ADM strongly adsorbs on the surface of the electrode by the adsorption of CTAB, thereby affecting the reduction current. This method provides a detection limit below 10(-10) mol/L for ADM. The experimental parameters, which influence the voltammetric responses of ADM, e.g. the pH value, variety and concentration of surfactants and the scan rate, were optimized. The reduction peak current changes linearly with the ADM concentration over the range from 2.5 x 10(-8) mol/L to 5 x 10(-6) mol/L. The detection limit is 4 x 10(-10) mol/L for an accumulation time of 3 min. The coefficient of variation, determined at 4 x 10(-6) mol/L ADM, is 3.0% (n = 8). Using this method, ADM in the patient's urine samples, which undergoes active ADM chemotherapy, was determined.  相似文献   

14.
A rapid, selective, and sensitive kinetic flow-injection method for iodide content determination with amperometric detection on a platinum electrode was developed. The method is based on the catalytic effect of iodide on the Mn3+ reaction with As3+ in the presence of sulfuric acid. The calibration curve was linear in the concentration range from 5.0 x 10(-7) to 1.0 x 10(-4) mol/L iodide. The limit of detection (LOD) was found to be 5.0 x 10(-9) mol/L iodide. The relative standard deviations (RSD) were 1.68% and 3.03% for 1.0 x 10(-3) mol/L standard and 1.0 x 10(-6) mol/L iodide solution (n = 6), respectively. The method has been successfully applied for determination of iodide in waters, table salts, fodder, organic substances and human blood sera. The results were compared with those obtained by a standard AOAC (Association of Official Analytical Chemists) method, as well as with those obtained by a kinetic spectrophotometric procedure for determination of iodide.  相似文献   

15.
CE methods have been developed for the determination of taurine in pharmaceutical formulation (microemulsion) and in biological media such as sweat. The CE system with end-column pulsed amperometric detection has been found to be an interesting method in comparison with UV and fluorescence detection for its simplicity and rapidity. A gold-disk electrode of 100 mm diameter was used as the working electrode. The effects of a field decoupler at the end of the capillary, separation voltage, injection and pressure times were investigated. A detection limit of 4 x 10(-5) mol/L was reached using integrated pulsed amperometric detection, a method successfully applied to taurine analysis of the biological samples such as sweat. For taurine analysis of oil-in-water microemulsion, fluorescence detector was the favored method, the detection limit of which was 4 x 10(-11) mol/L.  相似文献   

16.
Cao W  Liu J  Yang X  Wang E 《Electrophoresis》2002,23(21):3683-3691
A new end-column electrochemiluminescence (ECL) detection technique coupling to capillary electrophoresis (CE) is characterized. A 300 microm diameter Pt working electrode was used to directly couple with a 75 microm inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy) 3 2+ showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy) 3 2+ in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 microm capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 220-260 microm. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 microm capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 x 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 x 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-8) mol/L.  相似文献   

17.
A high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) at a boron-doped diamond film electrode with preliminary separation and preconcentration by solid-phase extraction (SPE) has been developed for the determination of 1-hydroxypyrene (1-HP) in human urine. 1-HP is among the most widely used biomarkers of exposure to polycyclic aromatic hydrocarbons. Optimal HPLC-ED conditions have been found: mobile phase methanol-0.05 mol L(-1) phosphate buffer pH 5.0 (80:20, v/v), detection potential +1,000 mV versus Ag/AgCl (3 mol L(-1) KCl), and flow rate 0.8 mL min(-1). For SPE, LiChrolut(?) RP-18 E cartridges were used. The extraction yield was (87.0 ± 5.8)% (n = 5). The concentration dependence of 1-HP was measured in the concentration range from 0.01 to 10 μmol L(-1) (2.18-2,180 μg L(-1)) using methanolic solutions resulting from the SPE pretreatment of spiked human urine samples. The limit of detection (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) of the biomarker were 0.013 μmol L(-1) (2.84 μg L(-1)) and 0.043 μmol L(-1) (9.39 μg L(-1)), respectively, which is sufficient for its determination in the urine of persons exposed to polycyclic aromatic hydrocarbons.  相似文献   

18.
A method based on capillary electrophoresis with electrochemical detection (CE-ED) has been developed for the determination of hesperidin (HP) and synephrine (SP) in the Chinese traditional herbal drug, Pericarpium Citri Reticulatae, the dried rind of the ripe fruits of Citrus reticulata Blanco (mandarin orange). The effects of some important factors such as the acidity and concentration of running buffer, separation voltage, and detection potential were investigated to determine the optimum conditions. The working electrode was a 300 microm diameter carbon disc electrode positioned opposite the outlet of the capillary. Both analytes could be well separated within 5 min in a 40 cm long capillary at a separation voltage of 12 kV in 50 mmol L(-1) borate buffer (pH 9.0). Excellent linearity was observed for the dependence of peak current on analyte concentration in the range from 2.5 x 10(-6) to 1.0 x 10(-3) mol L(-1) for SP and from 5.0 x 10(-6) to 1.0 x 10(-3) mol L(-1) for HP. The detection limits (S/N=3) for SP and HP were 4.96 x 10(-7) mol L(-1) and 6.54 x 10(-7) mol L(-1), respectively. This method has been successfully applied for the analysis of real samples, with satisfactory results.  相似文献   

19.
Q Dong  W Jin 《Electrophoresis》2001,22(13):2786-2792
A method for determination of the drug diclofenac sodium introduced into individual human erythrocytes by electroporation using capillary zone electrophoresis with electrochemical detection at a carbon fiber array microelectrode was developed. In this method, the whole cell was injected into the separation capillary by electromigration. Cell lysis was accomplished by injecting a plug of the separation buffer (1.25 x 10(-2) mol/L Na2B4O7-3.13 x 10(-3) mol/L NaOH). The optimum conditions of separation and detection were 20 kV for the separation voltage and 1.0 V for the detection potential. The concentration of diclofenac sodium in the single cells was quantified by a calibration curve. The mean concentration of diclofenac sodium introduced into the cell was 4.21 micromol/L. The relative standard deviation of the concentration of diclofenac sodium introduced into ten cells is 10%.  相似文献   

20.
A simple and highly selective electrochemical method was developed for the simultaneous determination of aspartame and cyclamate in dietary products at a boron-doped diamond (BDD) electrode. In square-wave voltammetric (SWV) measurements, the BDD electrode was able to separate the oxidation peak potentials of aspartame and cyclamate present in binary mixtures by about 400 mV. The detection limit for aspartame in the presence of 3.0x10(-4) mol L(-1) cyclamate was 4.7x10(-7) mol L(-1), and the detection limit for cyclamate in the presence of 1.0x10(-4) mol L(-1) aspartame was 4.2x10(-6) mol L(-1). When simultaneously changing the concentration of both aspartame and cyclamate in a 0.5 mol L(-1) sulfuric acid solution, the corresponding detection limits were 3.5x10(-7) and 4.5x10(-6) mol L(-1), respectively. The relative standard deviation (R.S.D.) obtained was 1.3% for the 1.0x10(-4) mol L(-1) aspartame solution (n=5) and 1.1% for the 3.0x10(-3) mol L(-1) cyclamate solution. The proposed method was successfully applied in the determination of aspartame in several dietary products with results similar to those obtained using an HPLC method at 95% confidence level.  相似文献   