首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents comparative experimental studies of the morphology and elemental composition of fly ash particles from coal- and biomass-fired boilers, deposited in each stage of 3-stage electrostatic precipitators (ESPs). It was shown that fly ash morphology, its physical properties, and the percentage of elements in the fly ash taken from each stage of ESP depend on the kind of fuel. The biomass fly ash contains many irregular large particles, which are pieces of unburned wood. Bulk density of biomass fly ash is on average lower than that of coal fly ash, and drastically decreases in the second and third stages of ESP. The resistivity, measured at electric field of 4 kV/cm, of fly ash from biomass-fired boilers is much lower than that from coal, and can be below 102 Ω m, whereas from coal, except the first stage, varies in the range from 107 to 1010 Ω m. The low resistivity of coal fly ash in the first stage of ESP results from high carbon content, and of biomass is probably an effect of additional high percentage of potassium, calcium and sodium sulfates. The percentage of Si, Al, Na, Fe, and Ti in fly ash from coal-fired boilers is much higher than from biomass, and in the opposite, the percentage of Mg, K, Ca, Mn, Mo, S, Cl, and P in biomass ash exceeds that in coal fly ash. Potential detrimental effects of biomass combustion products (salts, acids, tar) leaving the boiler on the construction elements of the electrostatic precipitator, including electrodes and HV insulators have been discussed in this paper. It was concluded that the long-term effects of biomass co-firing on the electrostatic precipitator performance, including the collection efficiency, have not been sufficiently studied in the literature and these issues require further detailed investigations.  相似文献   

2.
The back-discharge is a type of discharge that takes place in the presence of corona discharge and occurs at an electrode covered with a dielectric layer of resistivity higher than about 108 Ω m. Back-discharge can be observed in electrostatic precipitators when dust covering the collection electrode has low conductivity. In this paper, the studies of back-discharge generated in ambient air, in point-to-plane geometry with the plate electrode covered with fly ash are presented. The discharge is characterised in terms of its visual forms, current–voltage characteristics, and light emission spectra. Three forms of back-discharge were investigated: glow discharge, streamers, and low-current back-arc discharge. The current of the back-arc discharge was only a few milliamps. The discharge was stabilised by a high series resistance. It was noted that the voltage of ignition of the back-discharge for negative polarity is lower than for a positive one. Spectroscopic measurements of emission spectra provided information on elements present in the discharge column. The elements present in the fly ash, including toxic metals, can be re-entrained into the gas as particles or can be emitted as ions or neutrals during the discharge, and can decrease the collection efficiency of electrostatic precipitators. These elements were detected in the emission spectra. The effect of the discharge on the fly ash layer was also discussed. It was observed that sinter-like leftovers remain in the dust layer after a back-arc discharge.  相似文献   

3.
This study presents the results of investigations of a hybrid electrostatic filtration system (HEFS), which combines an electrostatic precipitator (ESP) and a fibrous filter installed downstream of the ESP. The particles escaping from the ESP carry large amount of charge and this can increase the filtration efficiency of the fibrous filter. The filtration characteristics, including the efficiency, pressure drop and ozone generation, were investigated experimentally. The influence of system parameters, including the filter type, applied voltage, and distance between the ESP and fibrous filter on the overall efficiency were also studied. The measured results show that utilizing the non-high-efficient fibrous filter to remove the charged particle could provide a much higher efficiency without adding the pressure drop due to the electrostatic force. If the efficiency was similar, the ozone generated by HEFS was much lower than that of the single ESP. The results proved that filter efficiency increased with a higher applied voltage and higher initial mechanical filtration efficiency. The distance between the filter and ESP had no influence on the system filtration efficiency. The efficiency of filter in HEFS supplied with the positive voltage was slightly lower than for the negative voltage. In addition, the mathematical model was utilized to model the air filter efficiency in HEFS. The modeled and measured results agreed reasonably. Overall conclusion is that the HEFS could operate at a high efficiency with the lower applied voltage, ozone generation and pressure drop.  相似文献   

4.
Lab-scale, two-stage electrostatic precipitation system comprising of precharging stage, in which PM2.5 particles are electrically charged, and collection stage, in which the charged particles are removed from the flowing gas by electric field, was investigated in this paper. Two types of electrostatic particle prechargers were compared with respect to the collection efficiency of the system: (1) co-flow precharger, in which ionic current was generated co-currently with the gas conveying the particles, and (2) counter-flow precharger, in which ionic current was generated oppositely to the flowing gas. In each case, the electrodes of precharger were supplied with DC or AC high-voltage in order to compare the effect of discharge mode on the collection efficiency of two-stage electrostatic precipitator. The collection stage was formed by two parallel-plate electrodes connected to DC high voltage source. Plate electrodes without discharge points (spikes) are corona-free electrodes, which prevent the collection stage from electrical discharges, and reduce the probability of back discharge ignition. The back discharge decreases collection efficiency of conventional electrostatic precipitators.It was concluded that the co-flow electrode configuration of the precharger, supplied with DC high voltage, has the highest total number collection efficiency for PM2.5 particles, higher than 95% and the mass collection efficiency larger than 99%. The counter-flow precharger provided only about 90% number collection efficiency of two-stage electrostatic precipitator. It was also shown that by AC electrode excitation, the collection efficiency of the system is lower than for DC supply. The two-stage electrostatic precipitators allowed obtaining higher fractional collection efficiency for PM2.5 particles than other conventional systems and can be recommended as highly effective devices for gas cleaning in power plants or cement industry.  相似文献   

5.
Recently, narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application for the cleaning of the exhaust gases emitted by diesel engines. Diesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. Therefore, an electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission.In this work, results of electrohydrodynamic (EHD) secondary flow and particle collection efficiency measurements in a narrow wire-cylinder type ESP are presented. The ESP was a glass cylinder (300 mm × 29 mm) equipped with a wire discharge electrode and two collecting cylinder-electrodes. A 0.23 mm in diameter and 100 mm long stainless-steel discharge wire electrode was mounted in the center of the cylinder, parallel to the main flow direction. The collecting electrodes were made of stainless steel cylinders, each with a length of 100 mm and inner diameter of 25.5 mm. An air flow seeded with a cigarette smoke was blown along the ESP duct with an average velocity of 0.9 m/s.The EHD secondary flow was measured using 2-dimensional particle image velocimetry (PIV) method. The PIV measurements were carried out in the wire electrode mid-plane, perpendicularly to the wire and the collecting electrodes. The results show similarities and differences of the particle flow in the wire-cylinder type ESP for a negative and a positive DC voltage polarity.The collection efficiency was calculated from the fractional particle concentration. The fractional particle concentration was measured using the optical aerosol spectrometer. The results of the fractional collection efficiency confirmed the common view that the collection efficiency of fine particles in the ESP increases with increasing voltage and it is higher for negative voltage polarity and decreases when decreasing particle diameter.  相似文献   

6.
振动流化床冷渣器试验研究   总被引:2,自引:1,他引:1  
本文提出了冷却高温炉渣的振动流化床技术,研制了集连续可控排放和冷却于一体的新型冷渣器工业装置.采用物理性质相异法较系统地研究了冷渣器内宽筛分物料的停留时间分布.对气固两相流的空气动力学特性和热态运行工况进行了试验研究和理论分析.结果表明,在风渣比为1.5~2.5Nm3/kg时,冷渣器的热回收率达到85%以上.  相似文献   

7.
A laboratory electrostatic precipitator (ESP) together with a bipolar pre-charger has been designed for studying charge-induced agglomeration and fine particle collection. In terms of particle numbers, the ESP collection efficiency drops to its minimum of near 90% for particles with diameters of near 0.2 μm and 3 μm. For other particles, its value is around 94%–95%. By using the bipolar pre-charger, the grade efficiency can be significantly increased for all particle sizes due to the charge-induced particle agglomeration. The grade collection efficiency rises to about 95%–98% for all size particles.  相似文献   

8.
A CFD model was developed to describe the particle laden gas flow through an ESP, particle charging and collection. The corona discharge was modeled using the open source software OpenFOAM to solve the Poison and charge conservation equations, and results were entered using user-defined field functions in the commercial CFD software STAR-CCM+. The gas flow, EHD flow, particle charging and dynamics were modeled using STAR-CCM+. The developed CFD model allows for direct solution of the drift and diffusional flux of gas ions. The influence of the various ESP dimensions, operating parameters and ash properties on the collection efficiency are reported.  相似文献   

9.
The aim of the present parametric study is to enhance the performances of a wire-to-square tube electrostatic precipitator (ESP) for the collection of submicrometer particles using dielectric barrier discharge (DBD). The input parameters under study are: the high voltage waveform, the wire electrode diameter, the collection electrode dimensions (width, discretization and number of collection sides) and the tube cross-section. The electrical measurements show that the discharge mode of the ESP is rather homogeneous. The particle collection efficiency as determined from aerosol spectroscopy measurements is higher at high applied voltage and within a certain frequency range. The parametric study of the ESP points out that using thicker wire electrodes as well as collection electrodes with different number of sides does not deteriorate the ESP performance. However, the penetration decreases with larger or discretized collection electrodes and larger tube cross-sections.  相似文献   

10.
The electrostatic precipitator (ESP) has been extensively used for collecting aerosol particles emitted from coal combustion, but its collection efficiency of PM2.5 (Particulate matter whose aerodynamic diameter is less than 2.5 μm) is relatively low due to insufficient particle charging. The positive pulsed ESP is considered to enhance particle charging and improve collection efficiency. A laboratory-scale pulsed ESP with wire-plate electrode configuration was established to investigate the particle charging and penetration efficiency under controlled operating conditions of different applied impulse peak voltages, impulse frequencies, dust loadings and residence times. The results show that most particles larger than 0.2 μm are negatively charged, while most particles smaller than 0.2 μm are positively charged. For a given operating condition, the particle penetration efficiency curve has the highest penetration efficiency for particles with a diameter near 0.2 μm, and there is always a negative correlation between the particle penetration efficiency and the average number of charges per particle. Under the same operating conditions, the particle penetration efficiency decreases with increasing impulse peak voltage and impulse frequency, but increases as the dust loading increases. The results imply that residence time of 4 s is optimum for particle charging and collection. PM2.5 number reduction exceeding 90% was achieved in our pulsed ESP.  相似文献   

11.
Fly ash deposition on boiler surfaces is a major operational problem encountered in biomass-fired boilers. Understanding deposit formation, and developing modelling tools, will allow improvements in boiler efficiency and availability. In this study, deposit formation of a model biomass ash species (K2Si4O9) on steel tubes, was investigated in a lab-scale Entrained Flow Reactor. K2Si4O9 was injected into the reactor, to form deposits on an air-cooled probe, simulating deposit formation on superheater tubes in boilers. The influence of flue gas temperature (589 – 968°C), probe surface temperature (300 – 550°C), flue gas velocity (0.7 – 3.5?m/s), fly ash flux (10,000 – 40,000?g/m2h), and probe residence time (up to 60?min) was investigated. The results revealed that increasing flue gas temperature and probe surface temperature increased the sticking probability of the fly ash particles, thereby increasing the rate of deposit formation. However, increasing flue gas velocity resulted in a decrease in the deposit formation rate, due to increased particle rebound. Furthermore, the deposit formation rate increased with probe residence time and fly ash flux. Inertial impaction was the primary mechanism of deposit formation, forming deposits only on the upstream side of the steel tube. A mechanistic model was developed for predicting deposit formation in the reactor. Deposit formation by thermophoresis and inertial impaction was incorporated into the model, and the sticking probability of the ash particles was estimated by accounting for energy dissipation due to particle deformation. The model reasonably predicted the influence of flue gas temperature and fly ash flux on the deposit formation rate.  相似文献   

12.
Using electrostatic precipitators (ESPs) in filtration systems results in higher system energy efficiency than fiber-based filters, but particle re-entrainment could lower the collection efficiency of ESPs. This paper demonstrates a novel ESP that utilizes foam-covered collecting electrodes to reduce particle re-entrainment and enhance collection efficiency. Particles that settle down within the pores of the foam are less likely to re-enter the airflow. Results show that foam-covered ESPs have 99 percent collection efficiency. Parametric plots demonstrate the effects of the key design variables, such as corona voltage, repelling voltage, and free airflow velocity on collection efficiency.  相似文献   

13.
In order to improve the particle collection efficiency of the electrostatic precipitator (ESP), a transverse plate ESP with bipolar discharge electrodes is proposed. The simulations of the velocity distribution have shown that when the inlet velocity is 1 m/s, within the range of 40 mm from electrode plate, the average velocities of windward side and leeward side are less than 0.7 m/s and 0.3 m/s respectively. It is clear that the velocity near the collection electrode plate of this bipolar ESP is much lower than that of the ordinary ESP at the same inlet velocity. This low velocity can lead to higher efficiency for fine dust collection due to the less dust re-entrainment in ESP. It is also found that the average velocities are getting lower when the distance between plates electrodes are greater than 150 mm in accordance with the simulations. The voltage current characteristics of the bipolar ESP are superior to the ordinary ESP. The pressure drop of the bipolar ESP is about 30% higher than that of the ordinary one. The dust penetration of the bipolar ESP is about 54% less than that of the ordinary ESP when the sintering dust with 25.405 μm mass median diameter is used as the test particulate under the condition of the electric field from 2.1 kV/cm to 3.2 kV/cm and the velocity from 1.0 m/s to 1.5 m/s.  相似文献   

14.
A single-stage, single-wire vertical wet electrostatic precipitator was designed and operated in air–water droplets flow to investigate its performance. The efficiency was compared with a glass micro fiber filter and proposed semi-empirical efficiency model, which was in good accuracy while considering the vapor content. Effects of geometric parameters on efficiency under different charge conditions were discussed. Due to evaporation mechanism, the corona current decreases for high flow rates at the same applied voltage. Findings indicated while developing flow is created inside the ESP, there exists an optimum wire-to-flow inlet spacing that provides maximum droplet collection efficiency.  相似文献   

15.
In this paper, the structure of single wire-plate unit in electrostatic precipitator (ESP) was optimized and dust removal process in an entire ESP was investigated using computational fluid dynamics (CFD). Collection efficiency is higher in the center of the ESP, but becomes lower near the edges. High applied voltage, low inlet velocity and large particle diameter are beneficial for dust collecting. As particle concentration increases, collection efficiency increases at the beginning, then decreases. When particle diameter is smaller, inlet velocity and particle concentration is higher, particle trajectories become less stable as turbulence is more severe.  相似文献   

16.
Flue gases emitted from coal fired power plants are mainly cleaned with electrostatic precipitators (ESP). Increased awareness of the effects of atmospheric pollution and tightening legislation force precipitator producers to increase their ESP efficiency, especially when collecting very fine particulates (PM2.5). The fly ash characteristic parameters are formatted during combustion process and its depend on the coal type as well as boiler parameters and combustion conditions. Due to that many series of tests were done to investigate the influence of fly ash physical and chemical properties on ESP operation.  相似文献   

17.
We constructed a single-stage, laboratory-scale electrostatic precipitator (ESP) and evaluated its physical and microbial collection efficacies. Ground rice husk was examined as a representative model of airborne particles carrying microorganisms (bacteria, molds and yeasts). Physical and microbial collection efficacies were evaluated at different voltages applied to the negative discharge electrode without ozone generation. The best collection efficiencies were observed at an applied voltage of ?6.0 kV, resulting in collection efficiencies of over 90% for the physical sample and 99.95% for bacteria. No molds or yeasts in the ground rice husk passed through the ESP operating at ?6.0 kV applied voltage.  相似文献   

18.
Results of spectroscopic investigations and current–voltage characteristics of electrical discharges between a needle and plate electrodes in a gas mixture simulating flue gases from coal fired power plants at atmospheric pressure are presented in the paper. In these investigations, back discharge was generated at the plate electrode covered with fly ash layer in order to simulate the conditions similar to those in electrostatic precipitators. To characterize the physical processes in back discharges, the emission spectra were measured and compared with those obtained for normal corona discharge generated in the same electrode configuration but with fly ash removed from the electrode. The emission spectra provide information on elemental and molecular composition of the layer. It was also shown that discharge characteristics in flue gas are quite different from those occurring in ambient air.  相似文献   

19.
通常热力发电厂将飞灰中未燃碳的含量作为评价锅炉燃烧效率的重要指标,通过测量飞灰中未燃碳的含量来评价煤粉燃烧的充分程度,进而实现优化燃烧、提高机组效率。基于激光诱导击穿光谱技术(LIBS)无接触、快速响应、高灵敏度、可以在线测量等特点,备用来测量飞灰中未燃碳的含量。由于烟气中CO2气体的存在,碳谱线强度会随CO2浓度的变化而改变。为了减少CO2气体对飞灰未燃碳测量结果的影响,提出并设计了具有二级旋风分离器的LIBS测量飞灰未燃碳含量实验系统,飞灰从给粉机流出后通过二级旋风分离器进入测量腔体,脉冲激光经过透镜作用于飞灰样品进而产生等离子体。LIBS系统采用双中心波长光谱仪,可测得飞灰中C,Si,Mg,Fe,Ca和Al等主要元素谱线,同时高分辨率通道可分辨出相邻C和Fe的元素谱线,可以在获得充分的飞灰光谱信息的同时保证了测量的精度。实验结果表明该系统可有效分离和收集飞灰颗粒,减少CO2气体对测量结果的干扰,为LIBS技术的工程应用提供了更准确的依据。  相似文献   

20.
A numerical analysis on the electrostatic capture of airborne viruses and nanoparticles in a homemade particle concentrator without a unipolar charger using commercial CFD software (CFD-ACE+) was presented. We simulated the effects of inlet/outlet configurations and particle diameters on the collection efficiency of the particle concentrator, and the simulation was in good agreement with the experimental measurements. We investigated the effects of the electrode arrangement on the collection efficiency. We also discussed the maximum collection efficiency and the relationship between the electric field intensity, the positions of the simulated particles on the inlet surface, and the collection efficiency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号