首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
High-throughput chiral liquid chromatography/tandem mass spectrometry   总被引:3,自引:0,他引:3  
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments.  相似文献   

2.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

3.
Urine, a blood filtrate produced by the urinary system, is an ideal bio-sample and a rich source of biomarkers for diagnostic information. Many components in urine are useful in clinical diagnosis, and urinary proteins can be strong indication for many diseases such as proteinuria, kidney, bladder and urinary tract diseases. To enhance our understanding of urinary proteome, the urine proteins were prepared by different sample cleanup preparation methods and identified by nano-high performance liquid chromatography electrospray ionization tandem mass spectrometry followed by peptide fragmentation pattern. The experimental results demonstrated that a total of 2283 peptides, corresponding to 311 unique proteins, were identified from human urine samples, in which 104 proteins with higher confidence levels. The present study was designed to establish optimal techniques to create a proteomic map of normal urinary proteins. Also, a discussion of novel approaches to urine protein cleanup and constituents is given.  相似文献   

4.
A multiresidue analysis method has been developed for the determination of pesticides in water by ultra-performance liquid chromatography (UPLC) combined with tandem mass spectrometry (MS/MS). The selected pesticides represent a broad range of polarity and volatility [benzoylcyclohexanedione (mesotrione and sulcotrione); chloroacetamide (acetochlor, alachlor, dimethenamide, and metolachlor); phenoxyacetic acid (2,4-D and MCPA); phenoxypropionic (dichloprop and mecoprop); phenylurea (chlortoluron, diuron, isoproturon, linuron, and metoxuron); sulfonylurea (foramsulfuron, iodosulfuron, and nicolsulfuron); triazine (atrazine, cyanazine, desethylatrazine (DEA), desisopropylatrazine (DIA), simazine, and terbutylazine)]. The analytes were extracted using solid-phase extraction (SPE). The separation was carried out on an acquity UPLC BEH C18 column (1.7 microm, 50 mm x 1 mm ID) using a gradient elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile. The pesticides were detected with a tandem mass spectrometer after being ionised positively or negatively (depending on the molecule) using an electrospray ionisation (ESI) source. To achieve the suitable extraction conditions for sample preparation, several parameters affecting the efficiency of SPE such as the nature of the sorbent and the eluent, extractant volume and pH were studied. The best recovery was obtained by the extraction with an Oasis HLB cartridge and 3 mL of a solution of acetonitrile/dichloromethane (1:1, v/v) at pH 2. The average recoveries of the pesticides in different samples ranged from 82 to 109%. The weight least squares (WLS) linear regression was used to calculate the limits of detection and quantification (LOD and LOQ) because the dispersion was heteroskedastic. All the pesticides could be correctly quantified at a concentration level of 50 ng L(-1) and most of them could be detected at a concentration inferior or equal to 8 ng L(-1). Efficiency and robustness of this method were evaluated by the analysis of several samples of real natural water.  相似文献   

5.
6.
A rapid and sensitive method for the determination of miglitol in human plasma using voglibose as internal standard has been developed and validated. Samples of plasma were deproteinated with acetonitrile and washed with dichloromethane before being analyzed by reversed-phase high-performance liquid chromatography (HPLC). Separation was carried out on a short Nucleosil C(18) column (5 microm, 50 x 4.6 mm i.d.) using 10 mmol/L ammonium acetate at 1.0 mL/min as mobile phase. The detector was an Applied Biosystems Sciex API 4000 mass spectrometer using atmospheric pressure chemical ionization (APCI) for ion production. The instrument was operated at unit resolution in the multiple reaction monitoring mode. The assay was linear over the range 5.00-2000 ng/mL with a limit of detection of 1.00 ng/mL. Intra- and inter-day precision were <2.82% and <2.92%, respectively, with accuracy of 93.3-106%. The assay was successfully applied to a clinical pharmacokinetic study of miglitol given as a single oral dose (50 mg) to healthy volunteers.  相似文献   

7.
A rapid method was developed for the simultaneous profiling of 29 free fatty acids in plasma using ultra-performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC/ESI-MS/MS). Barium acetate was used as the cationization agent in the positive ion mode for sensitive multiple reaction monitoring (MRM) experiments. The cis- and trans-C18:1 and -C18:2 isomers were baseline-separated using two tandem reversed-phase C18 UPLC columns, while identification of two pairs of positional isomers of C18:3 and C20:3 required isomer-specific product ions, as the analytes were not chromatographically resolved. The assay linearity was greater than three orders of magnitude and correlation coefficients were >0.99; the limits of detections were typically less than 0.2 microM. The method was successfully applied to plasma free fatty acid profiling of samples from volunteers who participated in a randomized crossover study involving the administration of either placebo or fish oil capsules. The results clearly indicate the ability to measure the time profiles of the n-3 fatty acids eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) in plasma for the volunteers given fish oil capsules while the concentrations of the other free fatty acids and the total free fatty acid concentration in plasma remained virtually constant.  相似文献   

8.
Nandrolone (19‐nortestosterone) is an androgenic anabolic steroid illegally used as a growth‐promoting agent in animal breeding and as a performance enhancer in athletics. Therefore, its use was officially banned in 1974 by the Medical Commission of the International Olympic Committee (IOC). Following nandrolone administration, the main metabolites in humans are 19‐norandrosterone, 19‐norethiocolanolone and 19‐norepiandrosterone, and their presence in urine is the basis of detecting its abuse. The present work was undertaken to determine, in human urine, nandrolone metabolites (phase I and phase II) by developing and comparing multiresidue liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) methods. A double extraction by solid‐phase extraction (SPE) was necessary for the complete elimination of the interfering compounds. The proposed methods were also tested on a real positive sample, and they allow us to determine the conjugated/free fractions ratio reducing the risk of false positive or misleading results and they should allow laboratories involved in doping control analysis to monitor the illegal use of steroids. The advantages of LC/MS/MS over GC/MS (which is the technique mainly used) include the elimination of the hydrolysis and derivatization steps: it is known that during enzymatic hydrolysis several steroids can be converted into related compounds and deconjugation is not always 100% effective. The validation parameters for the two methods were similar (limit of quantification (LOQ) <1 ng/mL and percentage coefficient of variance (CV%) <16.4), and both were able to confirm unambiguously all the analytes, thus confirming the validity of both techniques. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
研究建立了血清中尿素测定的新方法,以尿素同位素标记物(Urea-13C,15N2)为内标,样品用乙腈沉淀蛋白。以ZORBAXRX-SIL色谱分离柱,V(乙腈):V(水)=95:5为流动相,使用电喷雾三重四极杆串联质谱的多重反应监测模式(Multiple Reaction Monitoring,MRM)测定,以及同位素稀释的括号法进行定量。所建立的液相色谱同位素稀释串联质谱法(ID-LCMS/MS)对于分析血清尿素的批内、批间RSD分别为0.21%~0.85%、0.05%~0.38%,回收率为97.9%~102.3%,采用美国国家标准和技术研究院(NIST)的血清标准物质SRM909b进行了方法确证,测定结果与标准值的相对偏差小于0.5%且在其定值范围内。  相似文献   

10.
11.
Gatifloxacin is an advanced-generation, 8-methoxyfluoroquinolone that is active against a broad spectrum of pathogens, including antiobiotic resistant Streptococcus pneumoniae. Development of a rapid, sensitive and selective method for the determination of gatifloxacin in human plasma is essential for understanding the pharmacokinetics of the drug when administered orally or intravenously. Solid phase extraction (SPE) using Oasis HLB was used to extract gatifloxacin and the internal standard ciprofloxacin from plasma. A method based on liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS) was developed and validated to quantitate gatifloxacin in human plasma. The precursor and major product ions of the analyte were monitored on a triple quadrupole mass spectrometer with positive ion electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. Mechanisms for the formation of collision-induced dissociation products of gatifloxacin are proposed. Linear calibration curves were generated from 10--1000 ng/mL with coefficients of determination greater than 0.99. The interday and intraday precision (%RSD) was less than 6.0% and accuracy (%error) was less than 5.4% for gatifloxacin. The limit of detection (LOD) for the method was 500 pg/mL based on a signal-to-noise ratio of 3.  相似文献   

12.
A simple, sensitive and rapid high-performance liquid chromatography/positive electrospray ionization tandem mass spectrometry method was developed and validated for the assay of clopidogrel in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase column and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H](+) ions, m/z 322/212 for clopidogrel and m/z 264/154 for the internal standard. The assay exhibited a linear dynamic range of 5-6000 pg/mL for clopidogrel in human plasma. The lower limit of quantification was 5 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

13.
Glycosylation is one of the most common posttranslational modifications (PTMs) of proteins, the characterization of which is commonly achieved through proteomic protocol, involving trypsin digestion followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, it is often not possible to characterize all glycopeptides in a complex sample because of the high complexity of glycoproteomic samples, and the relative lower abundances of glycopeptides in comparison to the unmodified peptides. We present here a targeted MS/MS analysis approach, which utilizes a previously developed computational tool, GlyPID, to guide multiple experiments, thus permitting a complete characterization of all N‐glycosylation sites of glycoproteins present in a complex sample. We have tested our approach using model glycoproteins analyzed by high‐resolution LTQ‐FT MS. The results demonstrate a potential use of our method for a high‐throughput characterization of complex mixtures of glycosylated proteins. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

15.
Interlaboratory validation studies have been performed on 2 methods for the determination of chlormequat (CLQ) and mepiquat (MPQ). Both methods used identical extraction procedures and stable isotope internal standardization but differed in the use of liquid chromatography/mass spectrometry (LC/MS) or LC/tandem mass spectrometry (LC/MS/MS) for the determination, the amount of internal standard used, and the expected limit of detection. After addition of deuterated internal standards, CLQ and MPQ were extracted with methanol-water and determined by LC//MS or LC/MS/MS with positive electrospray ionization. Eight European laboratories participated in the LC/MS method study, analyzing mushroom, pear, wheat flour, and fruit puree with residues of CLQ in the range 0.040-1.19 mg/kg and of MPQ in the range 0.041-0.39 mg/kg. For CLQ, the Horwitz ratio (HoRat) values for individual test materials/levels were in the range 0.85-1.13 with a mean of 1.00, showing good method performance. For MPQ, the Ho values for mushroom, pear (both levels), and wheat flour were in the range 0.83-0.94, again indicating good method performance. For the determination of MPQ in infant food (fruit puree) at 0.041 mg/kg, the Ho was 1.7 when a value of 0 reported by one participant was excluded. In the LC/MS/MS study, in which 11 laboratories participated, a separate sample set was analyzed with residues of CLQ in the range 0.007-1.03 mg/kg and of MPQ in the range 0.008-0.72 mg/kg. Ho values for CLQ were in the range 0.27-1.36 and for MPQ in the range 0.51-2.10, all corresponding to acceptable method performance.  相似文献   

16.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

17.
The review discusses the pitfalls of the matrix effect in mass spectrometry detection hyphenated to liquid chromatography separation. Matrix effect heavily influences both qualitative and quantitative analyses, giving rise to suppression or enhancement of the signal. As generally recognised, the predominant cause is the presence of undesired components that co-elute in the chromatographic separation and alter the ionisation process. The interfering species can be components of the sample, compounds released during the pre-treatment/extraction process or reagents added to the mobile phase to improve chromatographic resolution. The different mechanisms proposed in literature to explain the suppression or the enhancement of the signal both in electrospray and atmospheric pressure chemical ionisations are presented and the results observed in the different experimental conditions are compared and discussed. All data together lead to conclude that the chemical properties of the target analyte, the kind of matrix, the matrix to analyte concentration ratio, the extraction process, the chromatographic conditions as well as the kind of the mass spectrometry instrumentation and the ionisation conditions can play a role. Likely all these potential causes act in a synergic way and the final effect observed is hardly due to only one of them. Depending on an unpredictable combination of conditions, signal suppression or enhancement can be observed. The review discusses the matrix effects observed in HPLC–MS and HPLC–MS/MS analysis proposes hypotheses to explain the observed behaviours and proposes methods and strategies to overcome the matrix effects.  相似文献   

18.
Tripamide is a drug widely used in clinical practice for the treatment of hypertension and edema. This work evaluated a screening method for Tripamide and its urinary metabolites in human urine, using high-performance liquid chromatography diode-array detection (HPLC/DAD). Identification of these metabolites was investigated by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) after dosing with 15 mg Tripamide. Acid hydrolysis showed that Tripamide is conjugated in the body. Two suspected metabolites were detected by HPLC/DAD. HPLC/ESI-MS/MS analysis suggested that these metabolites were probably hydroxylated together with loss of the -NH(2) group and dehydrogenation. These results will be useful in confirmation methods for Tripamide in doping control.  相似文献   

19.
Iralukast (CGP 45715A) is a potent peptido-leukotriene antagonist that is active in various in vitro and animal models for the treatment of asthma. An analytical challenge was to develop a sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method with a lower limit of quantitation (LLOQ) of 10 pg/mL for the analysis of iralukast when administered at low doses during clinical trials. Several issues had to be addressed in order to devise a LC/MS/MS assay for the above compound. First, iralukast appeared to be light sensitive and unstable at room temperature under acidic conditions. Second, a LLOQ of 10 pg/mL was needed to support several clinical trials. Third, positive electrospray ionization of iralukast did not yield the necessary sensitivity required for studies in humans. Consequently, LC/MS/MS conditions were optimized for the negative ion mode of detection. Fourth, sample preparation steps proved to be critical to reduce the possibility of microbore HPLC column (50 mm x 1.0 mm i.d.) obstruction, chromatographic deterioration, and matrix-mediated electrospray ion suppression. While our validated method addressed the above challenges, its major drawback was limited sample throughput capability. Nonetheless, plasma concentration-time profiles for patients with moderate asthma after oral administration of 200, 500, 1000, and 5000 microgram/kg/day of iralukast were successfully obtained.  相似文献   

20.
para-Aminobenzoic acid (PABA), a precursor in the synthesis of folates in plants, is determined by liquid chromatography/tandem mass spectrometry (LC/MS/MS). In plants PABA can be converted into its beta-D-glucopyranosyl ester (PABA-Glc) and can also exist in its free form. In this work, we developed and validated a quantitative method to study free and total PABA in plants. The total PABA (free PABA plus PABA-Glc) can be evaluated after acid hydrolysis at 80 degrees C for 2 hours. The plant material is homogenized and the PABA content is quantified using the standard addition procedure. The validated method is selective, sensitive, simple, accurate, has a recovery between 99.6 to 102.5%, is reproducible (RSD between 1.4 and 4.4%), and is linear between 2.5 and 1538 ng/mL. Free and total PABA determinations in five vegetables showed that different plant species had different amounts of free and total PABA, and that the ratios of total versus free PABA were also variable. This new method could be valuable for studies of folate synthesis in plants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号