首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
We present the development process for National Institute of Metrology (NIM) bovine serum albumin (BSA) certified reference material (CRM). Each CRM unit contains about 200 mg of purified BSA. The moisture, ignition residue, molecular weight, and high-performance liquid chromatography (HPLC) purity were analyzed and mass spectrometry based protein identification was carried out to ensure the material was BSA. Both amino acid based isotope dilution mass spectrometry (IDMS) and a purity deduction method were selected for value assignment. The certified value was the average of the IDMS and the purity deduction result. HPLC purity analysis was used to examine the homogeneity and stability of solid BSA CRM. Fifteen units were selected for between-bottle homogeneity examination and seven subsamples from the same bottle were selected for within-bottle homogeneity examination. Statistics showed the CRM passed both the between-bottle and the within-bottle homogeneity examination. The CRM stability under storage conditions (-20 °C) was tested for 18 months and no trend was observed. Uncertainties from the balance, amino acid purity, hydrolysis, method reproducibility, homogeneity, and stability were taken into account in uncertainty evaluation. The final certified value of NIM BSA CRM is (0.963±0.038) g/g.  相似文献   

2.
The National Metrology Institute of Japan has issued a certified reference material (CRM) of freshwater lake sediment for polycyclic aromatic hydrocarbon (PAHs) analyses. The certification used three extraction techniques: pressurized liquid extraction (PLE) with toluene, PLE with dichloromethane/ethyl acetate (1:1 by volume), and alkaline extraction (1 M KOH in methanol) in combination with microwave-assisted extraction. Both gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/dopant-assisted atmospheric pressure photoionization/MS (LC/DA-APPI/MS) analyses were used. Certified values are provided for 18 PAHs at 1–25 μg kg−1 except for perylene (2.08 × 103 μg kg−1), and information values are provided for two. Since the values of PAHs in the CRM are much lower than those in other CRMs and are comparable to those found at sites with little human influence, the CRM is suitable for PAH monitoring in sediment and soil samples.  相似文献   

3.
Excessive glucose present in the blood of diabetic patients binds with the hemoglobin of red blood cells resulting in the formation of glycated hemoglobin (HbA1c). Measurement of HbA1c levels may help in identifying the efficacy of the ongoing treatment and hence provide a better control over the disease. In the present study, we have synthesized a sensitive and stable scaffold, which consists of Au nanoparticles (GNPs)-dotted tubular TiO2, for the construction of an electrochemical HbA1c biosensor. 12-phosphotungstic acid has been used as a reducer after depositing well-dispersed GNPs on TiO2 nanotubes (TiO2 NTs) and an electron mediator by accelerating the electron transfer between the conductor and protein. The fabricated electrode was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), Fourier transform infrared spectroscopy (FTIR) and electrochemical impedance spectroscopic analysis (EIS). Biosensor exhibited low detection limit (0.5 μM), fast response time (3 s) and wide linearity (from 0.5 to 2000 μM). The working electrode was used 100 times over 4 months, when stored at 4 °C. The HbA1c biosensor was then effectively used to measure the % of HbA1c in the blood of apparently healthy persons and diabetic patients.  相似文献   

4.
Arsenate [As(V)] solution reference material, National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 7912-a, for speciation of arsenic species was developed and certified by NMIJ, the National Institute of Advanced Industrial Science and Technology. High-purity As2O3 reagent powder was dissolved in 0.8 M HNO3 solution and As(III) was oxidized to As(V) with HNO3 to prepare 100 mg kg-1 of As(V) candidate CRM solution. The solution was bottled in 400 bottles (50 mL each). The concentration of As(V) was determined by four independent analytical techniques—inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, graphite furnace atomic absorption spectrometry, and liquid chromatography inductively coupled plasma mass spectrometry—according to As(V) calibration solutions, which were prepared from the arsenic standard of the Japan Calibration Service system and whose species was guaranteed to be As(V) by NMIJ. The uncertainties of all the measurements and preparation procedures were evaluated. The certified value of As(V) in the CRM is (99.53 ± 1.67) mg kg-1 (k = 2).  相似文献   

5.
Microwave digestion and isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-SFMS) has been applied to the determination of Pb in rice flour. In order to achieve highly precise determination of low concentrations of Pb, the digestion blank for Pb was reduced to 0.21 ng g−1 after optimization of the digestion conditions, in which 20 mL analysis solution was obtained after digestion of 0.5 g rice flour. The observed value of Pb in a non-fat milk powder certified reference material (CRM), NIST SRM 1549, was 16.8 ± 0.8 ng g−1 (mean ± expanded uncertainty, k = 2; n = 5), which agreed with the certified value of 19 ± 3 ng g−1 and indicated the effectiveness of the method. Analytical results for Pb in three brown rice flour CRMs, NIST SRM 1568a, NIES CRM 10-a, and NIES CRM 10-b, were 7.32 ± 0.24 ng g−1 (n = 5), 1010 ± 10 ng g−1 (n = 5), and 1250 ± 20 ng g−1 (n = 5), respectively. The concentration of Pb in a candidate white rice flour reference material (RM) sample prepared by the National Metrology Institute of Japan (NMIJ) was observed to be 4.36 ± 0.28 ng g−1 (n = 10 bottles). Figure Digestion blank of Pb was carefully reduced to approximately 0.2 ng g-1 which permitted the highly precise determination of Pb at low ng g-1 level in foodstuff samples by ID-SFMS  相似文献   

6.
A flow-injection analytical (FIA) system, comprised of an electrochemical detector with a fructosyl-peptide oxidase (FPOX-CET) reactor and a flow-type spectrophotometer, was proposed for the simultaneous measurement of glycohemoglobin and total hemoglobin in blood cell. The blood cell samples were hemolyzed with a surfactant and then treated with protease. In the first stage of operation, total hemoglobin in digested sample was determined spectrophotometrically. In the second stage, fructosyl valyl histidine (FVH) released from glycohemoglobin by the selective proteolysis was determined specifically using the electrochemical detector with the FPOX-CET reactor. The FIA system could be automatically processed at an analytical speed of 40 samples per hour. The proposed assay method could determine selectively only the glycated N-terminal residue of β-chain in glycohemoglobin and total hemoglobin in blood cell. The enzymatic hemoglobin A1c (HbA1c) value calculated by the concentration ratio of the FVH to total hemoglobin, was closely correlated with the HbA1c values certified by the Japan Diabetic Society (JDS) and the International Federation of Clinical Chemistry (IFCC).  相似文献   

7.
A candidate certified reference material (CRM) for multiple shellfish toxins (domoic acid, okadaic acid and dinophysistoxins, pectenotoxins, yessotoxin, azaspiracids and spirolides) has been prepared as a freeze-dried powder from mussel tissues (Mytilus edulis). Along with the certified values, the most important characteristics for a reference material to be fit-for-purpose are homogeneity and stability. Acceptable between-bottle homogeneity was found for this CRM. Within-bottle homogeneity was assessed using domoic acid, and it was shown that repeated subsampling of the CRM can be performed precisely down to 0.35 g. Both short- and long-term stability studies carried out under isochronous conditions demonstrated excellent stability of the various toxins present in the material. While degradation of some analytes was observed at +60°C in short-term studies, it was determined that shipping at ambient temperature is adequate. No instability was detected in long-term stability studies, and it was shown that the material can be held at +18°C safely for up to 1 year. To guarantee stability of the CRM over its lifetime the stock will be maintained at −20°C. The results of the homogeneity and stability testing show that CRM–FDMT1 is appropriate for its intended use in quality assurance and quality control of shellfish toxin analysis methods.  相似文献   

8.
Progesterone is one of the steroid hormones. The hormone is especially important in preparing the uterus for the implantation of the blastocyst and in maintaining pregnancy. Its concentration in serum is measured to determine ovarian function and to predict early pregnancy. The progesterone concentration is also important for in-vitro fertilization and embryo-transfer outcomes. We have established isotope dilution liquid chromatography–tandem mass spectrometry as a primary method for the measurement of progesterone in human serum. Progesterone and its isotopic analogue, progesterone-13C2, in serum were monitored at mass transitions of m/z 315.2/109.2 and 317.2/111.2 respectively in multiple-reaction monitoring (MRM) mode with electrospray positive ionization. For validation of the method, progesterone in a National Institute of Standards and Technology standard reference material (NIST SRM) was measured, and the measured results were in good agreement with the reference values within the uncertainty. On the basis of the established method, progesterone certified reference material (CRM) was developed in this work. The certified value was (1.41 ± 0.036) μg kg−1. The repeatability of 1.1% and reproducibility of 0.14% showed that ID LC–MS–MS is a reliable and reproducible method. The expanded uncertainty for the measurement of progesterone in the CRM was approximately 2.6% within 95% confidence limits. The detection limit of progesterone was approximately 0.6 μg kg−1. The progesterone CRMs were distributed to representative clinical laboratories in the Republic of Korea for comparison with the chemiluminescence immunoassay (CLIA), which is the most sensitive immunoassay method. The results from the comparison showed quite a large bias among the participating laboratories. This implies that the CRM is a very important material for establishment of traceability to its practical use.  相似文献   

9.
A certified matrix reference material (CRM) for the measurement of benzene in ambient air has been developed at Laboratoire National de Métrologie et d’Essais. The production of these CRMs was conducted using a gravimetric method fully traceable to the International System of Units. The CRMs were prepared by sampling an accurate mass of a gaseous primary reference material of benzene, using a high-precision laminar flowmeter and a mass flow controller, with a PerkinElmer sampler filled with Carbopack™ X sorbent. The relative standard deviations obtained for the preparation of a batch of 20 tubes loaded with 500 ng of benzene were below 0.2%. Each CRM is considered independent from the others and with its own certified value and an expanded uncertainty estimated to be within 0.5%, lower than the uncertainties of benzene CRMs already available worldwide. The stability of these materials was also established up to 12 months. These CRMs were implemented during proficiency testing, to evaluate the analytical performances of seven French laboratories involved in benzene air monitoring.  相似文献   

10.
Reliable measurement results of electrolytic conductivity (EC), in particular for low values, must be metrologically traceable and be based on a realistic measurement uncertainty budget. The use of certified reference materials (CRMs) can help to achieve this goal. This paper presents results from all stages of the certification of an EC CRM with a conductivity of 1.5 μS cm?1, including the preparation of the batch solution and the evaluation of the homogeneity and stability of the bottled CRM. An uncertainty budget is presented for the CRM, including the main contributions from each of these sources. The CRM batch remained stable within its certified uncertainty for more than 1 year.  相似文献   

11.
This article describes the effect of a change in reference method for HbA1c measurement on results in our EQA programme. Important indicators of analytical quality, particularly reproducibility, bias and uncertainty, were assessed. Basic analytical quality indicators for the measurement of HbA1c in an EQA survey during 2000–2008 were evaluated. Three EQA surveys per year were performed. Usually there were more than 200 participating laboratories in each survey. Reproducibility, systematic differences, bias, and methodology changes before and after IFCC reference method implementation were determined. In the EQA surveys, target values traceable to the IFCC reference method are used. Estimation of the combined uncertainty of the result was a voluntary part of the surveys and was reported by 50% of participating laboratories. Reproducibility of all participants’ measurements was close to the target value of CV = 5.0% (coefficient of variation). The group of participants using HPLC methodology had reproducibility lower than 5.0% in each survey, whilst the immunochemistry group usually had CV values more than 6.0%. The differences in individual results from target values ranged in the interval ±12% for HPLC methods but more (−8 to +30%) for immunochemistry methods. During the monitored time interval the number of participants using HPLC methods increased up to 70% whilst the number of participants using immunochemistry methods decreased approximately to 30%. The combined uncertainty (u c ) reported by participants varies between 4.0 and 4.5% for HbA1c values between 30 and 90 mmol/mol. No significant differences between precision and systematic errors (bias) after the implementation of IFCC method of measurement for HbA1c to routine processes for HPLC were observed. Immunochemical methods do not fulfil requirements for analytical reproducibility.  相似文献   

12.
Ethylene glycol monobutyl ether (EGBE), an industrial solvent, is absorbed by the body not only by inhalation but also by dermal absorption (liquid or vapour). EGBE is metabolized to butoxyacetic acid (BAA). Pooled freeze-dried urine candidate reference material (RM) was prepared from urine obtained from persons occupationally exposed to EGBE. This material has the advantage of containing butoxyacetic acid in both the free and conjugated (glutamine and glycine) forms, as found in native urine. In all GC method modifications used, acid hydrolysis was used to release BAA from its conjugated form. The amount of butoxyacetic acid in homogeneity and stability testing was measured by GC after derivatisation with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide. Detection was by MS in EI mode, in the authors’ laboratory. For interlaboratory comparison of the reference material GC methods with MS, FID, and ECD were used. Different extraction solvents (dichloromethane–isopropanol 2:1, ethyl acetate, or dichloromethane) and derivatisation reagents (trimethylsilyldiazomethane, N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide) were used. Using ANOVA (at the statistical level α = 0.05) no changes were found in the concentration of butoxyacetic acid during fifteen month isochronous stability testing, or in homogeneity testing. The uncertainty contributions were u h = 8.8 mg L−1 and u s = 6.5 mg L−1. The concentration of butoxyacetic acid in freeze-dried urine RM was evaluated from the results of eight laboratory data sets within an interlaboratory comparison by use of the interactive statistical software IPECA. The contribution to total uncertainty derived from interlaboratory comparison was u i = 12.7 mg L−1. The reference value (c = 273 ± 33 mg L−1) is an unweighted arithmetic average of accepted results. The value is traceable to the pure butoxyacetic acid (98% w/w; Acros Organic #257760010) used as calibrant. The uncertainty given is combined expanded uncertainty derived from the results from interlaboratory comparison, and from homogeneity and stability tests (k = 2). The reference material will be used to verify method performance in the biological monitoring of occupational exposure to EGBE.  相似文献   

13.
Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of polychlorinated biphenyls (PCBs). The raw materials for the CRMs were an insulation oil (CRM 7902-a and CRM 7903-a) and a fuel oil (CRM7904-a and CRM 7905-a). A solution of PCB3, PCB8, and technical PCB products, comprising four types of Kaneclor, was added to the oil matrices. The total PCB concentrations in the PCB-fortified oils (CRM 7902-a and CRM 7904-a) are approximately 6 mg kg−1. In addition, the mineral oils which were not fortified with PCBs were also distributed as CRMs (CRM 7903-a and CRM 7905-a). Characterization of these CRMs was conducted by the NMIJ/AIST, where the mineral oils and the PCB solution were analyzed using multiple analytical methods such as dimethylsulfoxide extraction, normal-phase liquid chromatography, gel permeation chromatography, reversed-phase liquid chromatography, and chromatography using sulfoxide-bonded silica; and/or various capillary columns for gas chromatography, and two ionization modes for mass spectrometry. The target compounds in the mineral oils and those in the PCB solution were determined by one of the primary methods of measurement, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 11 PCB congeners (PCB3, 8, 28, 52, 101, 118, 138, 153, 180, 194, and 206) in the CRMs. These CRMs have information values for PCB homologue concentrations determined by using a Japanese official method for determination of PCBs in wastes and densities determined with an oscillational density meter. Because oil samples having arbitrary PCB concentrations between respective property values of the PCB-fortified and nonfortified CRMs can be prepared by gravimetric mixing of the CRM pairs, these CRMs can be used for validation of PCB analyses using various instruments which have different sensitivities. Figure Preparation and certification processes of the mineral oil CRMs (example shown is polychlorinated biphenyls in insulation oil, high/low concentrations) Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

14.
An on-chip type cation-exchange chromatography system with electrochemical detection of HbA1c, which is one of the most important diabetes marker protein, was developed using ferrocene-conjugated anti-human hemoglobin (Hb) monoclonal antibody (FcAb). The FcAb was used as an electrochemical probe for the detection of each Hb. The system contains syringe pump, on-chip type cation-exchange column consisted of PDMS and cation-exchange resin beads, and a three-electrode flow-cell system. The separation conditions of HbA1c in blood calibrator samples from other Hbs, e.g. HbA0, HbA1a or HbA1b, were optimized using the on-chip type system. The electrochemical oxidation current from FcAb reacting with each Hb was measured at 350 mV (vs. Ag/AgCl). Hbs including HbA1a and HbA1b, HbA1c and HbA0 fractions were eluted in this order. A linear relationship between HbA1c levels and electrochemical oxidation currents was obtained in the range from 4.0% to 12.6% HbA1c. All procedure including antigen-antibody reaction was completed in 15 min. Furthermore, a good correlation was obtained between KO500 method (HPLC) and our proposed method. These results indicate that the on-chip type system with electrochemical detection can be applied to a novel POCT device for rapid and precise detection of HbA1c.  相似文献   

15.
Certified reference materials (CRMs) are playing an increasingly important role in environmental monitoring in Japan. The National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) has been developing CRMs of organic calibration solutions since 2003, and has issued several NMIJ CRMs. The development of these materials was conducted at the NMIJ in cooperation with candidate material producers. The freezing-point depression method was principally adopted for assessment of the purity of starting materials to give reliable certified values. Gas chromatography with flame ionization detection (GC–FID) and/or high-performance liquid chromatography (HPLC), which are based on independent principles and whose levels of accuracy are well evaluated, were applied in combination with other methods to avoid any possible analytical bias. Purity assessment is outlined for two typical examples, 1,1-dichloro-2,2-bis(p-chlorophenyl)ethane (p,p′-DDD) and 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (p,p′-DDT), which were used as starting materials for a CRM under development. Methods adopted for gravimetric preparation and ampouling of solutions were qualified and optimized to reduce the uncertainties of certified values due to these factors. Furthermore, a new experimental scheme for assessment of stability and preparation variation is proposed for the proper estimation of uncertainties. Presented at BERM-11, October 2007, Tsukuba, Japan.  相似文献   

16.
This paper presents results from the European Commission-funded project Doncalibrant, the objective of which was to produce calibrators with certified mass fractions of the Fusarium toxins deoxynivalenol (DON), 3-acetyldeoxynivalenol (3-Ac-DON), 15-acetyldeoxynivalenol (15-Ac-DON), and nivalenol (NIV), in acetonitrile. The calibrators, available in ampoules, were sufficiently homogeneous, with between-bottle variations (s bb) of less than 2%. Long-term stability studies performed at four different temperatures between −18 and 40 °C revealed no significant negative trends (at a confidence level of 95%). Molar absorptivity coefficients (in L mol−1 cm−1) were determined for all four toxins (DON: 6805 ± 126, NIV: 6955 ± 205, 3-Ac-DON: 6983 ± 141, 15-Ac-DON: 6935 ± 142) on the basis of a mini-interlaboratory exercise. The overall uncertainty of the calibrators’ target values for DON and NIV were evaluated on the basis of gravimetric preparation data and include uncertainty contributions from possible heterogeneity, storage, and transport. The Doncalibrant project resulted in the production of calibrators for DON (IRMM-315) and NIV (IRMM-316) in acetonitrile with certified mass fractions of 25.1 ± 1.2 μg g−1 and 24.0 ± 1.1 μg g−1, respectively. Both CRMs became commercially available from the Institute for Reference Materials and Measurements (IRMM, Geel, Belgium) at the beginning of 2007.  相似文献   

17.
This study used high-performance affinity chromatography (HPAC) to examine the binding of gliclazide (i.e., a sulfonylurea drug used to treat diabetes) with the protein human serum albumin (HSA) at various stages of modification due to glycation. Frontal analysis conducted with small HPAC columns was first used to estimate the number of binding sites and association equilibrium constants (K a) for gliclazide with normal HSA and glycated HSA. Both normal and glycated HSA interacted with gliclazide according to a two-site model, with a class of high-affinity sites (average K a, 7.1–10 × 104 M−1) and a group of lower-affinity sites (average K a, 5.7–8.9 × 103 M−1) at pH 7.4 and 37 °C. Competition experiments indicated that Sudlow sites I and II of HSA were both involved in these interactions, with the K a values for gliclazide at these sites being 1.9 × 104 and 6.0 × 104 M−1, respectively, for normal HSA. Two samples of glycated HSA had similar affinities to normal HSA for gliclazide at Sudlow site I, but one sample had a 1.9-fold increase in affinity at this site. All three glycated HSA samples differed from normal HSA in their affinity for gliclazide at Sudlow site II. This work illustrated how HPAC can be used to examine both the overall binding of a drug with normal or modified proteins and the site-specific changes that can occur in these interactions as a result of protein modification.  相似文献   

18.
Two marine sediment certified reference materials, NMIJ CRM 7304-a and 7305-a, have been issued by the National Metrology Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) for the determination of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs). The raw materials of the CRMs were collected from a bay near industrial activity in Japan. Characterization of these CRMs was conducted by NMIJ, where the sediments were analyzed using multiple analytical methods such as pressurized liquid extraction (PLE), microwave-assisted extraction (MAE), saponification, Soxhlet extraction, supercritical fluid extraction (SFE), and ultrasonic extraction; the target compounds were determined by one of the primary methods of measurements, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 14 PCB congeners (PCB numbers 3, 15, 28, 31, 70, 101, 105, 138, 153, 170, 180, 194, 206, 209) and 4 OCPs (γ-HCH, 4,4′-DDT, 4,4′-DDE, 4,4′-DDD) in both CRMs. NMIJ CRM 7304-a has concentrations of the contaminants that are a factor of 2–15 greater than in CRM 7305-a. Both CRMs have information values for PCB homolog concentrations determined by collaborative analysis using a Japanese official method for determination of PCBs. The total PCB concentrations in the CRMs are approximately 920 and 86 μg kg−1 dry mass respectively. Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users.  相似文献   

19.
The quality control of groundwater monitoring requires the availability of representative CRMs. This paper describes the preparation of two artificial groundwater reference materials, CRM 616 (high carbonate content) and CRM 617 (low carbonate content), the homogeneity and stability studies and the analytical work performed for the certification of a range of major elements (Ca, Cl, Fe, K, Mg, Mn, Na, NO3, PO4 and SO4).  相似文献   

20.
Two reference materials, at relatively low and high concentrations (GBW08404 and GBW08405), for analysis of the mass fractions of Cd, Cr, Hg and Pb in polypropylene were developed. The reference materials were prepared by doping blank polypropylene base material with Cd, Cr, Hg and Pb in the form of oxides, salts or pigments. Homogeneity and stability studies were performed by inductively coupled plasma mass spectrometry. The certification of the four analytes was carried out by isotope-dilution mass spectrometry (IDMS) with microwave-assisted digestion. Combined uncertainties were calculated from the IDMS uncertainty evaluation budget and the uncertainty of the homogeneity. The mass fractions of Cd, Cr, Hg and Pb of the two certified reference materials (CRMs) were from 8 to 1,000 mg kg−1. The two samples were also used in an interlaboratory comparison scheme in which National Institute of Metrology, China, National Metrological Institute of Japan and Korea Research Institute of Standards and Science participated. The agreement of the comparison results proved that the certification procedure of the CRMs is valid and that the certified values of Cd, Cr, Hg and Pb are accurate and reliable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号