首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The use of a bis(terpyridine)ruthenium(ii) complex for peptide labeling (Ru-CO labeling) supplied high intensity peaks in mass spectrometry (MS) analysis that overcame the contribution of protonation or sodiated adduction to peptides. Ru-CO-labeled insulin A- and B-chains were detected simultaneously in comparable peak abundance by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The mass spectra of chymotryptic peptide fragments of Ru-CO-labeled insulin also simultaneously indicated both N-terminal fragment ions, and amino acid sequences were determined easily by matrix-assisted laser desorption/ionization post-source-decay (MALDI-PSD). The sensitivity of detecting Ru-CO-labeled peptide fragment ions was not dependent on the length or the sequences of the peptides. The Ru-CO labeling method was applied to tryptic myoglobin fragments. The method indicated that each fragment ion is detected nearly equal in abundance and enabled the desired fragment ions to be distinguished from matrix clusters or their in-source fragments in lower mass regions. The desired fragment ions can be found in the mass region higher than 670.70 (= Ru-CO). This method provided a high sequence coverage (96%) by peptide mass fingerprinting (PMF). Application of this method to a protein mixture (myoglobin, lysozyme and ubiquitin) successfully achieved high sequence-coverage characterization (>90%) of these proteins simultaneously.  相似文献   

2.
通过酸酐同系物标记蛋白质的N-末端,经过凝胶电泳分离,使用基质辅助激光解析电离飞行时间质谱仪进行鉴定,建立了一种基于化学标记和质谱技术的、用于蛋白质的N-末端鉴定和相对定量新方法。标记后的蛋白质的N端肽以相差14 Da的成对峰形式在质谱中出现,而非N-末端肽则是以单峰呈现,从而实现了末端肽的特异性识别;通过端肽的信号强度对3种标记蛋白质的不同比例的混合溶液实现了相对定量分析。  相似文献   

3.
We have examined the applicability of the 'nested' collision induced dissociation/post-source decay (CID/PSD) method to the sequencing of novel peptides from solitary wasps which have neurotoxic venom for paralyzing other insects. The CID/PSD spectrum of a ladder peptide derived from an exopeptidase digest was compared with that of the intact peptide. The mass peaks observed only in the CID/PSD spectrum of a ladder peptide were extracted as C-terminal fragment ions. Assignment of C-terminal fragment ions enabled calculation of N-terminal fragment masses, leading to differentiation between N-terminal fragment ions and internal fragment ions. This methodology allowed rapid and sensitive identification by removing ambiguity in the assignment of the fragment ions, and proved useful for sequencing unknown peptides, in particular those available as natural products with a limited supply.  相似文献   

4.
A method incorporating nested collision-induced dissociation/post-source decay (CID/PSD) combined with endopeptidase digestion is described as an approach to determine the sequence of N-terminally modified peptides. The information from immonium and related ions observed in the CID/PSD spectrum was used for the selection of a suitable endopeptidase for the digestion of peptides. Rapid and reliable assignment of peptide sequence was performed by the comparison of CID/PSD spectra of both intact and endopeptidese-digested peptide fragments, since the assignments of the observed fragment ions to either N- or C-terminal ions can thus be carried out unambiguously. This nested CID/PSD method was applied to the sequence determination of two peptides from the solitary wasps Anoplius samariensis and Batozonellus maculifrons (pompilid wasps), which could not be sequenced by the Edman method due to N-terminal modification.  相似文献   

5.
Isomeric triazine pesticides: prometryn (N,N′-bis(1-methylethyl)-6-(methylthio)-1,3,5-triazine-2,4-diamine) and terbutryn (N-(1,1-dimethylethyl)-N′-ethyl-6-(methylthio)-1,3,5-triazine-2,4-diamine) are quantitatively analyzed by matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) without prior separation. The total concentration of the pesticide isomers was quantified by ‘standard’ MALDI using simetryn as an internal standard, while the composition of the isomeric mixture was estimated using post-source decay (PSD) MALDI-MS. Prometryn and terbutryn generate different PSD-MALDI product ions, and a PSD fragment characteristic of each isomeric pesticide is used for quantification of the mixture. Specifically, the fragment at m/z=186 is used for quantification of terbutryn, while the fragment at m/z=200 is used for prometryn. Fast evaporation and dried droplet methods were employed in PSD-MALDI quantification, and linear signal response was obtained for both methods. However, the fast evaporation method showed better quantitative characteristics and a lower detection limit.  相似文献   

6.
A method for the simultaneous determination of the number of free cysteine groups and disulfide-bound cysteine groups in proteins has been developed based on the sequential labeling of free and bound thiol functionalities with two ferrocene-based maleimide reagents. Liquid chromatography/electrochemistry/mass spectrometry was used to assign the N-(2-ferroceneethyl)maleimide (FEM) labeled free cysteine functionalities in a tryptic digest mixture, whereas a precursor ion scan enables the detection of peptides with ferrocenecarboxylic acid-(2-maleimidoyl)ethylamide (FMEA) labeled disulfide-bound cysteine groups after reduction. Fragment spectra of the labeled peptides yield an excellent coverage of b-type and y-type ions. The ferrocene labeled cysteines were fragmented as 412 Da (FEM) and 455 Da (FMEA). These fragment masses are significantly higher than unlabeled amino acids or dipeptides and are easily detected. The position of free and disulfide-bound cysteine may therefore be assigned in an amino acid sequence.  相似文献   

7.
We report a 'top-down' approach for characterization of proteins, and identification of binding sites in protein-drug complexes using nanoelectrospray ionization hybrid quadrupole time-of-flight tandem mass spectrometry (nanoESI-MS/MS). The efficiency of direct fragmentation of intact protein ions and the feasibility of this method were initially demonstrated using several well-characterized proteins with different molecular weights including metallothionein (6126 Da), cytochrome c (horse, 12360 Da), myoglobin (horse, 16592 Da), and hemoglobin (human, 64453 Da). Simply varying collision energy without enzyme digestion and gel or LC separation generated a range of peptide fragments of these proteins. Over 80% of these peptide ions matched those in the SWISS-PROT database with mass accuracy of 8 to 32 ppm with external calibration. This technique was further applied to fragment a cisplatin-metallothionein complex to identify the binding sites, demonstrating a potential application in the study of drug-protein binding.  相似文献   

8.
Sequences and end groups of complex copolyesters were determined by fragmentation analysis by means of matrix‐assisted laser desorption/ionization collision‐induced dissociation tandem mass spectrometry (MALDI CID MS/MS). The complexity of the crude copolyester mixture was reduced by a chromatographic separation followed by a MALDI time‐of‐flight (TOF) investigation of fractions. Due to overlapping compositional and end‐group information a clear assignment of end groups was very difficult. However, the fragmentation of suitable precursor ions resulted in typical fragment ion patterns and, therefore, enabled a fast and unambiguous determination of the end groups and composition of this important class of polymers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
We have acquired multi-stage mass spectra (MSn) of four branched N-glycans derived from human serum IgG by matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight mass spectrometry (MALDI-QIT-TOF-MS) in order to demonstrate high sensitivity structural analysis. [M+H]+ and [M+Na]+ ions were detected in the positive mode. The detection limit of [M+Na]+ in MS/MS and MS3 measurements for structural analysis was found to be 100 fmol, better than that for [M+H]+. The [M+H]+ ions subsequently fragmented to produce predominantly a Y series of fragments, whereas [M+Na]+ ions fragmented to give a complex mixture of B and Y ions together with some cross-ring fragments. Three features of MALDI-QIT-CID fragmentation of [M+Na]+ were cleared by the analysis of MS/MS, MS3 and MS4 spectra: (1) the fragment ions resulting from the breaking of a bond are more easily generated than that from multi-bond dissociation; (2) the trimannosyl-chitobiose core is either hardly dissociated, easily ionized or it is easy to break a bond between N-acetylglucosamine and mannose; (3) the fragmentation by loss of only galactose from the non-reducing terminus is not observed. We could determine the existence ratios of candidates for each fragment ion in the MS/MS spectrum of [M+Na]+ by considering these features. These results indicate that MSn analysis of [M+Na]+ ions is more useful for the analysis of complicated oligosaccharide structures than MS/MS analysis of [M+H]+, owing to the higher sensitivity and enhanced structural information. Furthermore, two kinds of glycans, with differing branch structures, could be distinguished by comparing the relative fragment ion abundances in the MS3 spectrum of [M+Na]+. These analyses demonstrate that the MSn technology incorporated in MALDI-QIT-TOF-MS can facilitate the elucidation of structure of complex branched oligosaccharides.  相似文献   

10.
Recent mass spectrometry instrumentation developments include the appearance of novel hybrid tandem instrumentation, Q-TOF, consisting of a quadrupole mass analyzer (MS1) and a time-of-flight (TOF) analyzer. The TOF analyzer is not scanned, but collects all fragment ions entering the analyzer at a given time. Thus, the typical precursor scan experiment cannot be performed. Instead, a full MS-MS spectrum can be acquired for each mass passed by MS1. Appropriate data manipulation, i.e. extracted ion current chromatograms, can correlate specific fragment ion formation to the parent ion. Precursor scanning and LC-MS-MS are compared on a Q-TOF instrument for the determination of protein modifications, including acetylation and phosphorylation. Model peptides used for phosphopeptide detection were generated from a mixture of beta-casein. Model acetylated peptides were generated from a mixture of acetylated substance P1-9 and substance P1-11. The results were then applied to a more complex mixture, a digest of HIV-p24. Results indicate that precursor scanning is useful for screening, but that LC-MS-MS has a sensitivity advantage and is less susceptible to suppression effects. LC-MS-MS, therefore, appears to be better for the detection of trace components in complex mixtures.  相似文献   

11.
PSD does not usually generate a complete series of y-type ions, particularly at high mass, and this is a limitation for de novo sequencing algorithms. It is demonstrated that b(2) and b(3) ions can be used to help assign high mass x(N-2) and x(N-3) fragments that are found in vacuum ultraviolet (VUV) photofragmentation experiments. In addition, v(N)-type ion fragments with side chain loss from the N-terminal residue often enable confirmation of N-terminal amino acids. Libraries containing several thousand peptides were examined using photodissociation in a MALDI-TOF/TOF instrument. 1345 photodissociation spectra with a high S/N ratio were interpreted.  相似文献   

12.
A strategy for the characterization of bacterial lipoprotein-in this case Braun’s lipoprotein (an outer membrane 7-ku lipoprotein) isolated from Escherichia coli—is described by time-of-flight mass spectrometric (TOF/MS) techniques [252Cf plasma desorption (PD) TOF/MS and matrix-assisted laser desorption-ionization (MALDI) TOF/MS]. Covalent linkage of lipid at the N-terminal cysteine (posttranslationally modified to a S-[2,3-bis(acyloxy)-propyl]-N-acylcysteine) and, therefore, strict insolubility in aqueous solution constitute common features for this class of proteins. Relative molecular mass determination of the major molecular species of Braun’s lipoprotein was obtained by selection of an appropriate mixture of organic solvents compatible with matrix/support materials useful for the mass spectrometric techniques applied. Minor components of this lipoprotein that differ only in the fatty acid composition of the lipid anchor were detected by PD TOF/MS after enzymatic release of the extremely hydrophobic N-terminal amino acid followed by selective extraction with chloroform. Part of the primary sequence of this lipoprotein was confirmed based on peptide fragment ions observed in the positive ion PD mass spectra of cyanogen bromide-generated peptide fragments that had been isolated previously by reverse phase high-performance liquid chromatography (HPLC). Peptidoglycan fragments that represent the attachment sites of lipoprotein to peptidoglycan were enzymatically released, separated by reverse phase HPLC, and finally characterized by time-of-flight mass spectrometric techniques (252Cf-PD TOF/MS, MALDI TOF/MS). The results obtained with both techniques differed only in the better sensitivity obtained with MALDI TOF/MS, which consumed a factor of 100 to 1000 less material than with PD TOF/MS.  相似文献   

13.
A novel microfluidic method of continually detecting and counting beads‐labeled cells from a cell mixture without fluorescence labeling was presented in this paper. The detection system is composed of a microfluidic chip (with a permanent magnet inserted along the channel), a signal amplification circuit, and a LabView® based data acquisition device. The microfluidic chip can be functionally divided into separation zone and detection zone. By flowing the pre‐labeled sample solution, the target cells will be sequentially separated at the separation zone by the permanent magnet and detected and counted at the detection zone by a microfluidic resistive pulse sensor. Experiments of positive separation and detection of T‐lymphocytes and negative separation and detection of cancer cells from the whole blood samples were carried out to demonstrate the effectiveness of this method. The methodology of utilizing size difference between magnetic beads and cell‐magnetic beads complex for beads‐labeled cell detection is simple, automatic, and particularly suitable for beads‐based immunoassay without using fluorescence labeling.  相似文献   

14.
Isolation of tryptic peptide ions, along with their differentially labeled analogs derived from an artificial QconCAT protein, is performed using multiple correlated harmonic excitation fields in an FT-ICR cell. Simultaneous fragmentation of the isolated unlabeled and labeled peptide pairs using IRMPD yields specific y-series fragment ions useful for quantification. The mass increment attributed to stable isotope labeling at the C-terminus is maintained in the C-terminal fragment ions, providing multiple measurements of labeled/unlabeled intensity ratios during highly selective detection. The utility of this approach has been demonstrated in the absolute quantification of components of an unfractionated chicken muscle protein mixture.  相似文献   

15.
Data on defocused metastable ions have been obtained for a series of structurally significant fragment ions in the mass spectra of the estrogenic steroid, estrone methyl ether and the alkaloid tropine. These data, in conjunction with measurements on defocused metastable ions in the mass spectra of isotopically labeled analogs and complete high resolution mass spectra provide important insights into the details of fragmentation processes, specifically: (a) an enumeration and determination of the frequent multiple origins of fragment ions in the mass spectra of such complex molecules, (b) specification of skeletal atoms lost and retained in concerted (one step) processes, and at each step of stepwise processes, leading to a particular fragment ion and (c) information on the relative contributions of concerted and stepwise processes resulting in the genesis of a given ion.  相似文献   

16.
We present a novel enhancement to matrix-assisted laser desorption ionization (MALDI) post-source decay (PSD) analysis whereby fragment ions from multiple precursor ions are acquired into the same spectrum without employing a timed ion gate to preselect each parent ion. Fragment ions are matched to their corresponding precursor ions by comparing spectra acquired at slightly different reflectron electric fields. By measuring the difference in time-of-flight (TOF) between the two spectra for each fragment, it is possible to calculate the mass of the fragment ion and its parent. This new "parallel PSD" technique reduces analysis time and consumes less sample than conventional PSD, which requires an ion gate for serial preselection of precursor ions.  相似文献   

17.
Here, we explore a de novo sequencing strategy in which we combine Lys-N protein digestion with differential isotopic dimethyl labeling to facilitate the (de novo) identification of multiply charged peptides in ESI-MS, both under CID and ETD conditions. For a large fraction of the Lys-N generated peptides, all primary amines are present at the N-terminal lysine, enabling specific labeling of the N-terminus. Differential derivatization of only the peptide N-terminus in combination with the simultaneous fragmentation of the corresponding isotopologues allows the straightforward distinction of N-terminal fragments from C-terminal and internal fragments. Furthermore, also singly and multiply charged N-terminal fragments can easily be distinguished due to the mass differences of the isotope labeled fragment pairs. As a proof of concept, we applied this approach to proteins isolated from an avocado fruit, and were able to partially de novo sequence and correctly align, with green plant homologues, a previously uncharacterized avocado ascorbate peroxidase.  相似文献   

18.
Oligosaccharides represent complex class of analytes for mass spectrometric analysis due to the high variety of structural isomers concerning glycosidic linkages and possible branching. A systematic study of the negative ion mode matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry of various neutral oligosaccharides under selection of an appropriate matrix, like 2,5‐dihydroxyacetophenone (2,5‐DHAP) is reported here, without commonly used anion dopant strategies. Nevertheless, we were able to generate relevant in‐source decay (ISD) cross‐ring fragment ions, typically obtained in the negative ion mode. Data observed indicate that the intrinsic property of the terminal non‐reduced aldose is crucial for this behavior. A systematic study of the post source decay (PSD) of molecular, pseudomolecular and ISD cross‐ring cleavage precursor ions is reported here. A direct comparison of the positive and negative ion mode MALDI MS1 and PSD behavior of neutral oligosaccharides could also be performed under the use of the same matrix preparation, because 2,5‐DHAP is fully compatible with positive ion mode acquisition. We found that PSD spectra of deprotonated neutral oligosaccharides obtained in the negative ion mode are richer, because they contained both glycosidic and cross‐ring fragment ions. However, we also found that cross‐ring fragment ions are readily produced in the positive ion mode when potassiated precursor ions were selected. In addition, we show evidence that non‐anionic dopants and specific instrumental parameters can also significantly influence the ISD fragmentation. Taken together, our results should increase our understanding of oligosaccharide behavior in the negative ion mode as well as increase our knowledge regarding many aspects of in‐source MALDI chemistry. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
A simple and effective method was developed for peptide sequencing and protein identification through the determination of its N-terminal residue. The method of N-terminal carbamidomethylation with iodoacetamide could specifically and remarkably enhance the intensity of a1 ions in the tandem mass spectra of the peptide derivatives without significantly altering their fragmentation pattern, thus allowing determination of their N-terminal residues. The effectiveness and specificity of the method was demonstrated by confirming and extending sequence interpretation of several model peptides and proteins. The developed method was then applied in the LC-MS/MS analysis of the tryptic digests of myoglobin and a whole protein extract from rat heart tissues. The results from database searches were well validated with the enhancement of a1 ions in tandem mass spectra and the specificity of protein identification was obtained when the information of N-terminal residues was included in the database search.  相似文献   

20.
Photochemical reagents that cleave proteins at specific sites (photoproteases) are useful for studying protein structure and protein-ligand interactions. PolyammineCo(III) complexes are tested here as photochemical probes to cleave proteins. Irradiation of a mixture of lysozyme, a model protein, and polyammineCo(III) complexes resulted in the facile cleavage of the peptide backbone. Photocleavage yielded two fragments of molecular weights 10.6 and 3.7 kDa, and these masses sum to the molecular mass of lysozyme (14.3 kDa). No cleavage was detected in the absence of the metal complex, in the dark, or upon irradiation at wavelengths of >420 nm. The photocleavage yield increased with irradiation time and with the concentrations of the metal complex and the protein. N-terminal sequencing of the 10.6 kDa fragment indicated residues that are identical to the N-terminus of lysozyme, and sequencing of the 3.7 kDa fragment indicated Val-Ala-Trp-Arg, an internal sequence of lysozyme. From the known primary sequence of lysozyme and the sequencing data, the cleavage site was assigned to Trp108-Val109. Molecular modeling indicates that the observed cleavage site is within few angstroms from the proposed metal binding site at Glu35-Asp52. This is the first report of the successful photocleavage of proteins, with high selectivity, by transition metal complexes. This novel observation can facilitate the rational design of transition metal complexes for the photochemical footprinting of metal binding sites on proteins.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号