首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive high-performance liquid chromatographic method for the simultaneous assay of amiodarone and desethylamiodarone in plasma, urine and tissues has been developed. The method for plasma samples and tissue samples after homogenizing with 50% ethanol, involves deproteinization with acetonitrile containing the internal standard followed by centrifugation and direct injection of the supernatant into the liquid chromatograph. The method for urine specimens includes extraction with a diisopropyl ether-acetonitrile (95:5, v/v) mixture at pH 7.0 using disposable Clin-Elut 1003 columns, followed by evaporation of the eluate, reconstitution of the residue in methanol-acetonitrile (1:2, v/v) mixture and injection into the chromatograph. Separation was obtained using a Radial-Pak C18 column operating in combination with a radial compression separation unit and a methanol-25% ammonia (99.3:0.7, v/v) mobile phase. A wavelength of 242 nm was used to monitor amiodarone, desethylamiodarone and the internal standard. The influence of the ammonia concentration in the mobile phase on the capacity factors of amiodarone, desethylamiodarone and two other potential metabolites, monoiodoamiodarone (L6355) and desiodoamiodarone (L3937) were investigated. Endogenous substances or a variety of drugs concomitantly used in amiodarone therapy did not interfere with the assay. The limit of sensitivity of the assay was 0.025 micrograms/ml with a precision of +/- 17%. The inter- and intra-day coefficient of variation for replicate analyses of spiked plasma samples was less than 6%. This method has been demonstrated to be suitable for pharmacokinetic and metabolism studies of amiodarone in man.  相似文献   

2.
ZLR-8 is a nitric oxide releasing derivative of diclofenac for the treatment of inflammation. In this paper, a sensitive and reliable high-performance liquid chromatography method for simultaneous determination of ZLR-8 and its active metabolite diclofenac in the plasma of beagle dogs has been developed and validated. After the addition of ketoprofen as the internal standard (IS), plasma samples were extracted with n-hexane-isopropanol (95:5, v/v) mixture solution and separated by HPLC on a reversed-phase C(18) column with a mobile phase of gradient procedure. Analytes were determined by the UV detector which was set at 280 nm. The method was proved to be sensitive and specific by testing six different plasma batches. Calibration curves of ZLR-8 and diclofenac were linear over the range 0.05-4.0 microg/mL. The within- and between-batch precisions (RSD%) were lower than 10% and accuracy ranged from 85 to 115%. The lower limit of quantification was identifiable and reproducible at 0.05 microg/mL. The proposed method has been readily implemented in preclinical pharmacokinetics studies of ZLR-8 and its active metabolite diclofeance. Representative plasma concentration vs time profiles resulting from administration of ZLR-8 to beagle dogs are presented in this communication.  相似文献   

3.
4.
A high-performance liquid chromatography assay with ultraviolet detection was developed for the simultaneous determination of the anti-epileptic drugs lamotrigine, carbamazepine and zonisamide in human plasma and serum. Lamotrigine, carbamazepine, zonisamide and the internal standard chloramphenicol were extracted from serum or plasma using liquid-liquid extraction under alkaline conditions into an organic solvent. The method was linear in the range 1-30 microg/mL for lamotrigine, 2-20 microg/mL for carbamazepine, and 1-40 microg/mL for zonisamide. Within- and between-run precision studies demonstrated coefficient of variation <10% at all tested concentrations. Other anti-epileptic medications tested did not interfere with the assay. The method is appropriate for determining lamotrigine, carbamazepine and zonisamide serum or plasma concentrations for therapeutic monitoring.  相似文献   

5.
6.
Oxycodone (14-hydroxy-7,8-dihydrocodeinone) is a potent opioid receptor agonist. In the present study, a liquid-liquid extraction-based reversed-phase HPLC method with UV detection was validated and applied for the analysis of oxycodone and its major metabolite, noroxycodone, in human plasma. The analytes were separated using a mobile phase, consisting of acetonitrile and phosphate buffer (8:92, v/v) at a flow rate of 1 mL/min, and UV detection at 205 nm. The retention times for oxycodone, noroxycodone and codein (internal standard) were 14.7, 13.8 and 10.2 min, respectively. The validated quantitation range of the method was 2-100 ng/mL for oxycodone and 10-100 ng/mL for noroxycodone. The developed procedure was applied to assess the pharmacokinetics of oxycodone and its metabolite following administration of a single 20 mg oral dose of oxycodone hydrochloride to one healthy male volunteer.  相似文献   

7.
A method for the simultaneous determination of pirprofen and its metabolite, the pyrrole derivative, in human plasma is described. The two compounds and the butyric acid analogue of the pyrrole derivative used as internal standard are extracted from plasma with chloroform, then back-extracted into an alkaline buffer. After addition of acid, the aqueous phase is assayed by high-performance liquid chromatography using a fixed-wavelength ultraviolet detector at 254 nm. The limit of quantitation is 0.1 micrograms/ml (0.396 mumol/l for pirprofen and 0.400 mumol/l for the pyrrole derivative).  相似文献   

8.
9.
10.
A high-performance liquid chromatographic method for the determination of R- and S-prenylamine in human plasma and urine is described. It involves a two-step liquid-liquid extraction of prenylamine from biological material and preparation of diastereomeric urea derivatives with R-(-)-naphthylethyl isocyanate, a chiral fluorescence marker. Separation and quantitation of the diastereomeric prenylamine derivatives are carried out by a reversed-phase high-performance liquid chromatographic system with fluorimetric detection. The limit of determination is less than 2 ng of enantiomer per ml of urine and less than 1 ng of enantiomer per ml of plasma. A preliminary kinetic study on one healthy volunteer who had received a single oral dose of racemic prenylamine (100-mg film tablet) showed distinctly higher plasma and urine concentrations of the R-enantiomer.  相似文献   

11.
A high-performance liquid chromatographic assay has been developed and validated for the determination of centbutindole and its hydroxy metabolite in serum. The method involves extraction of serum samples with diethyl ether at pH greater than 8, back-extraction into 0.5 M hydrochloric acid and finally again with diethyl ether after addition of 2 M potassium hydroxide. Separation was accomplished by reversed-phase high-performance liquid chromatography on a cyano column with an acetonitrile-phosphate buffer system. The recovery of centbutindole and its metabolite was always greater than 80%. Calibration curves were linear over the concentration range 0.25-5 ng/ml for centbutindole and 0.05-1 ng/ml for the hydroxy metabolite. Although the lower limit of detection was 0.1 ng/ml for centbuntindole and 0.02 ng/ml for the hydroxy metabolite, the reliable limits of quantitation were 0.25 and 0.05 ng/ml, respectively, using 4 ml of serum.  相似文献   

12.
A method has been developed for the simultaneous determination of Tranilast, N-(3',4'-dimethoxycinnamoyl)anthranilic acid (N-5'), and metabolites in plasma and urine from humans, dogs and rodents administered N-5'. Total N-5' and metabolite N-3 conjugates were determined in human urine. Detection limits in plasma were 0.2 micrograms/ml for metabolite N-3-S and N-5' and 0.1 micrograms/ml for metabolites N-3 and N-4. In urine, detection limits were 2 micrograms/ml for metabolite N-3-S and N-5' and 1 micrograms/ml for metabolites N-3 and N-4. Metabolite N-4 was not identified in any sample assayed.  相似文献   

13.
A rapid, sensitive, stereospecific reversed-phase high-performance liquid chromatographic method was developed for simultaneous quantitation of ketoprofen enantiomers, probenecid and their conjugates in biological fluids. Following addition of the internal standard, indoprofen, the constituents were extracted into isooctane-isopropanol (95:5), water-washed, extracted with chloroform, then evaporated and the residue sequentially derivatized with ethyl chloroformate and L-leucinamide hydrochloride. The formed diastereomers were chromatographed on a reversed-phase column with a mobile phase of 0.06 M KH2PO4-acetonitrile-triethylamine (65:35:0.1) at a flow-rate of 1 ml/min and a detection wavelength of 275 nm. The minimum quantifiable concentration was 0.5 micrograms/ml in 100 microliters of rat plasma and urine samples. The intra- and inter-day coefficients of variation for this method are less than 10%. The assay is successfully applied to a pharmacokinetic study. The simultaneous analysis of probenecid with several other non-steroidal anti-inflammatory drugs was also successful.  相似文献   

14.
15.
A novel method was developed for the determination of amiodarone and desethylamiodarone by high-performance liquid chromatography (HPLC) coupled with chemiluminescent (CL) detection. The procedure is based on the post-column photolysis of the analytes into photoproducts which are active in the tris(2,2′-bipyridyl)ruthenium(III) [Ru(bpy)33+] CL system. Ru(bpy)33+ was on-line generated by photo-oxidation of the Ru(II) complex in the presence of peroxydisulfate. The separation was carried out on a Mediterranea C18 column with isocratic elution using a mixture of methanol and 0.017 mol L−1 ammonium sulfate buffer of pH 6.8. Under the optimum conditions, analytical curves, based on standard solutions, were linear over the range 0.1-50 μg mL−1 for amiodarone and 0.5-25 μg mL−1 for desethylamiodarone. The detection limits of amiodarone and desethylamiodarone were 0.02 and 0.11 μg mL−1, respectively. Intra- and inter-day precision values of 0.9% relative standard deviation (R.S.D.) (n = 10) and 1.6% R.S.D. (n = 15), respectively, were obtained. The method was applied successfully to the determination of these compounds in serum and pharmaceutical formulations.  相似文献   

16.
A high-performance liquid chromatographic method was developed for the simultaneous determination of haloperidol and reduced haloperidol in human plasma, urine and rat tissue homogenates using bromperidol as an internal standard. The method involved extraction followed by injection of 50-80 microliters of the aqueous layer onto a C18 reversed-phase column. The mobile phase was 0.5 M phosphate buffer-acetonitrile-methanol (58:31:11, v/v/v) and the flow-rate was 0.6 ml/min. The column effluent was monitored by ultraviolet detection at 214 nm. The retention times for reduced haloperidol, haloperidol and bromperidol were 5.4, 7.2 and 8.4 min, respectively. The detection limits for haloperidol and reduced haloperidol in human plasma were both 0.5 ng/ml, and the corresponding values in human urine were both 5 ng/ml. The coefficients of variation of the assay were generally low (below 10.7%) for plasma, urine, blood and tissue homogenates. No interferences from endogenous substances or any drug tested were found.  相似文献   

17.
The isoxazol derivative leflunomide [N-(4'-trifluoromethylphenyl)-5-methylisoxazole-4-carboxamide] is an inhibitor of de novo pyrimidine synthesis used for the treatment of rheumatoid artrithis. In the present study, a liquid-liquid extraction-based reversed-phase HPLC method with UV detection was validated and applied for the analysis of leflunomide and its active metabolite, A77 1726, in human plasma. The analytes were separated using a mobile phase, consisting of acetonitrile, water and formic acid (40/59.8/0.2, v/v), at a flow rate of 0.5 mL/min, and UV detection at 261 nm. The retention times for A77 1726, leflunomide and warfarin (internal standard) were 8.2, 16.2 and 12.2 min, respectively. The validated quantification range of the method was 0.05-100 micro g/mL for leflunomide and 0.1-100 micro g/mL for A77 1726. The developed procedure was applied to assess steady-state plasma concentrations of A77 1726 in patients with rheumatoid arthritis treated with 10 or 20 mg leflunomide per day.  相似文献   

18.
19.
20.
A sensitive and selective high-performance liquid chromatographic method has been developed for a new anticonvulsant, fluzinamide, and three of its active metabolites. This method requires only 0.5 ml of plasma, and it involves a single extraction with a mixture of hexane--dichloromethane--butanol (55:40:5). The plasma extract is chromatographed on a 10-micron, C18 reversed-phase column and quantitated by ultraviolet absorbance at 220 nm. The concentration--response curves for all four compounds are linear from 0.05 micrograms/ml to at least 10 micrograms/ml. The extraction efficiency of this method is greater than 90%. The accuracy and precision of the method were tested by analyzing spiked unknown samples that had been randomly distributed across the concentration range. The mean concentrations found were within +/- 9% of the various amounts added with a standard deviation of +/- 3.5%. This method has been successfully applied to the analysis of samples obtained from fluzinamide-dosed dogs, healthy unmedicated volunteers, and patients who were at steady state with phenytoin, carbamazepine, and fluzinamide.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号