首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
新型离子交换硅胶键合相的制备及评价   总被引:2,自引:0,他引:2  
雷晓玲  王俊德  丛润滋 《色谱》1999,17(5):431-434
二甲基氯硅烷与硅胶表面反应,形成牢固的SiH键之后,连接上活泼的中间体——烯丙基缩甘油醚作为柔软的分子臂,最后接上二乙基氨基,由此制得了新型的离子交换硅胶键合相。经漫反射红外光谱、元素分析和高效液相色谱法对键合相进行了鉴定和评价。结果表明:键合反应按预定路线进行,键合相具有较好的色谱性能。此种方法可有效地运用于无孔硅胶填料的制备。  相似文献   

2.
Very fast reversed-phase separations of biomacromolecules are performed using columns made with superficially porous silica microsphere column packings ("Poroshell"). These column packings consist of ultra-pure "biofriendly' silica microspheres composed of solid cores and thin outer shells with uniform pores. The excellent kinetic properties of these new column packings allow stable, high-resolution gradient chromatography of polypeptides, proteins, nucleic acids, DNA fragments, etc. in a fraction of the time required for conventional separations. Contrasted with <2-microm non-porous particles, Poroshell packings can be used optimally with existing equipment and greater sample loading capacities, while retaining kinetic (and separation speed) advantages over conventional totally porous particles.  相似文献   

3.
Summary A new reversed-phase (RP) HPLC method has been developed and validated for the separation of the main opium alkaloids morphine, codeine, thebaine, papaverine and noscapine on a non-porous (micropellicular) stationary phase. On this phase quantification of the compounds by internal standardization with brucine was achieved extremely rapidly, in ca 1.5 min, only. Thus, the analysis time for the opium alkaloids was approximately one tenth of that on porous stationary phases. Different opium samples were investigated using non-porous and porous packings. The correlation between the results was excellent. Presented at Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, September 1–3, 1999  相似文献   

4.
Adsorptive membranes were investigated for the downstream processing of plasmid DNA by quantifying both separation efficiencies and adsorption uptake with the anion-exchange membranes. Separation efficiencies of the 10-ml Mustang-Q were measured using pulses of 6.1-kilo base pair plasmid DNA and lysozyme tracers, and comparing the responses for both conventional and reverse-flow operation. The plasmid exhibited nearly 200 plates/cm, almost as high efficiency as the protein despite the large difference in size. This behavior contrasts strongly with typical behavior for spherical porous particle packings, which predicted large decreases in efficiency with increases in tracer size. Batch adsorption isotherms for the 6.1-kilo base pair plasmid on small sheets of anion-exchange membranes at various ionic strengths showed high capacities for very large biomolecules. The maximum binding capacity for the membrane unit was calculated as 10 mg plasmid/ml, an order of magnitude greater than typical values reported for porous beads.  相似文献   

5.
Qin W  Li SF 《The Analyst》2003,128(1):37-41
An ionic liquid (IL) coated capillary was prepared and investigated for DNA separation. The electroosmotic flow of the capillary was reversed between pH 4.5 and 9. Below 900 base pairs the larger DNA fragment suffered more retardation in the IL coated capillary due to the increasing charge density of the fragment with size. In the presence of 4% hydroxyethylcellulose, the phiX174 DNA-Hae III digest fragments were baseline separated in both IL- and polyacrylamide-coated capillary except for the fragments of 271 and 281 base pairs; while the analysis time was shorter in the IL-coated capillary. Our experiments indicated that the IL-coated capillary could work stably in the run buffer for at least 96 h with no notable deterioration in performance.  相似文献   

6.
Xu F  Jabasini M  Liu S  Baba Y 《The Analyst》2003,128(6):589-592
On a polymethylmethacrylate (PMMA) microchip, double-stranded DNA fragments with a wide size range from 50 bp to 20 kbp were separated by two polymer solutions. One was a hydroxypropylmethylcellulose-4000 (HPMC-4000) solution of 1.3% (w/v) to separate fragments below 590 bp, and another was a mixed four molecular weight poly(ethylene oxide) solution at a total concentration of 0.1% to separate fragments above 520 bp. The widths at half height (wh) of the fragments had a good relationship with their migration times (tR) in both polymer solutions. Such a relationship was suitable for obtaining the wh values of unresolved peaks, calculating the resolution of two adjacent fragments, and optimizing microchip separation matrices. Based on the relativity, a low viscosity medium containing 2% HPMC-50 and 8% glucose was optimized for high-performance separation of a phiX174 HaeIII restriction fragment digest.  相似文献   

7.
An increasing number of hereditary diseases are becoming amenable to diagnosis by analysis of DNA as the responsible genes are located and identified. Gel electrophoresis of DNA fragments plays a central role in the diagnosis of hereditary disease. Electrophoretic separation of differently sized fragments enables the characterization or typing of normal variants which are known to be genetically linked to disease genes. For some diseases it is possible to directly detect mutations by DNA electrophoresis. Deletion mutants may be detected by a restriction fragment of altered size or by a failure to amplify a coding region with the polymerase chain reaction. Carriers of small deletions, involving a few base pairs, may be identified by DNA amplification which produces heteroduplexes that show characteristic, anomalous electrophoretic migration. Mutations that alter restriction sites also alter the sizes of restriction fragments. Common disease mutations that alter a single base pair may be detected using a pair of reactions with normal and mutant oligonucleotides under conditions where a perfect match is necessary for hybridization, amplification or ligation. Alternatively a mismatched oligonucleotide primer may be designed to generate a restriction site with either the normal or mutant allele, following DNA amplification. Finally a number of techniques are available that are useful as screening tools for novel mutations.  相似文献   

8.
A method for the determination of phosphorylation sites in phosphoproteins based on column-switching high-performance liquid chromatography (HPLC) has been developed. The HPLC system consisted of a titania precolumn for the selective adsorption of phosphopeptides, an anion-exchange analytical column and a UV detector (215 nm). Rabbit muscle phosphorylase a (RPa) and porcine stomach pepsin (PSP) were tested as model phosphoproteins. After protease digestion, the resulting phosphopeptides were successfully isolated by column-switching HPLC. The phosphopeptide fractions were analyzed by electrospray ionization mass spectrometry with a positive or negative ion mode after purification by reversed-phase HPLC. Pseudo-molecular ion peaks corresponding to Gln-Ile-Ser(p)-Val-Arg (MW 681.7) and Glu-Ala-Thr-Ser(p)-Gln-Glu-Leu (MW 856.8) were detected from the tryptic digest of RPa and chymotryptic digest of PSP, respectively, which agreed with the theoretically expected phosphopeptide fragments.  相似文献   

9.
Capillary zone electrophoresis and high-performance liquid chromatography were compared with regard to the separation of oligonucleotides and double-stranded DNA. Both anion-exchange and reversed-phase high-performance liquid chromatography on non-porous particles are considered to be superior to capillary electrophoresis in terms of speed and selectivity in the analysis of oligonucleotides up to 30 bases in length. Moreover, reversed-phase chromatography allows the simultaneous purification of detritylated oligonucleotides with recoveries > 90%. Compared with anion-exchange chromatography, there is no need for a subsequent desaltation step because the volatile buffer system can be readily evaporated. With regard to dsDNA, however, the resolving power of capillary electrophoresis cannot be matched by anion-exchange chromatography at present. Moreover, the combined use of hydroxyethylcellulose and ethidium bromide not only yielded a separation efficiency equal to that achieved by means of gel-filled capillaries but also avoids some of their limitations such as the destruction of the gel matrix at high current densities and the bias involved in electrokinetic injection.  相似文献   

10.
The impact of hexadecyltrimethylammonium bromide (CTAB) on the separation of ds-DNA by capillary electrophoresis in conjunction with laser-induced fluorescence (CE-LIF) detection using poly(ethylene oxide) (PEO) solution is described. The use of CTAB for improved separation reproducibility and efficiency of DNA has not been demonstrated although it is widely used for controlling the magnitude and direction of electroosmotic flow in CE. With increasing CTAB concentration, the interactions of DNA with ethidium bromide (EtBr) and with the capillary wall decrease. For the separation of DNA fragments with the sizes ranging from several base pairs (bp) to 2,176 bp, a polymer solution consisting of 0.75% poly(ethylene oxide), 100 mM TB buffer (pH 8.0), 25 microg/mL EtBr, and 0.36 microg/mL CTAB is proper. Using the PEO solution, we separated a mixture of DNA markers V (pBR 322/HaeIII digest) and VI (pBR 328/BglI digest and pBR 328/HinfI digest) within 8 min at -375 V/cm, with the limit of detection of 2.0 ng/mL based on the peak height for the 18-bp DNA fragment. The method is highly efficient (>10(6)plate/m), repeatable (RSD of the migration times <1.5%), and sensitive. In addition, it is convenient to fill a capillary (75 microm in diameter) with such a low-viscosity PEO solution by syringe pushing.  相似文献   

11.
A HPLC technique has been developed, based on hydrophobic-interaction Chromatography with a non-porous packing (TSKgel Butyl-NPR, Tosoh Biosep LLC), that allows separation of the open circular (nicked) and supercoiled forms of five DNA plasmids, ranging in size from 4 to 30 kilo base pairs (kb). The identity of the bands was determined through light scattering and gel electrophoresis. Several buffers, gradients, flow-rates and temperatures were evaluated in determining the optimum operating conditions for the separation. For all plasmids a reversed ammonium sulfate in phosphate buffer (pH 7.1) gradient was established. The chromatographic resolution between the supercoiled and nicked peaks was found to be a function of flow-rate and temperature. The resolution and the elution order did not vary with plasmid size, with the open-circular form always being eluted before the supercoiled form. Hydrophobic-interaction chromatography is a useful alternative to ion exchange or size exclusion for the chromatography of large plasmids, up to 30 kb.  相似文献   

12.
Ring-opening metathesis polymerization- (ROMP) derived monoliths were prepared from 5-norborn-2-enemethyl bromide (NBE-CH2Br) and tris(5-norborn-2-enemethoxy)methylsilane ((NBE-CH2O)3SiCH3) within the confines of surface-silanized borosilicate columns (100 × 3 mm I.D.), applying Grubbs’ first generation benzylidene-type catalyst [RuCl2(PCy3)2(CHPh)]. Monoliths were converted into weak anion exchangers via reaction with diethyl amine. The resulting monolithic anion exchangers demonstrated a very good potential for the anion-exchange separation of nucleic acids applying a phosphate buffer (0.05 mol/L, pH 7) and NaCl (1.0 mol/L) as a gradient former. Fast and efficient separations, indicated by sharp and highly symmetric analyte peaks, were established. Except for the 267 and 298 base pair fragments, the eleven fragments of a ds-pUC18 DNA Hae III digest were baseline separated within ∼8 min. Nineteen fragments of a ds-pBR322 Hae III digest were separated within ∼12 min. There, only the 192 and 213 base pair fragments and the 458, 504 and 540 base pair fragments coeluted. A ds-pUC18 DNA Hae III digest was used as a control analyte in evaluating the influence of organic additives on the mobile phase such as methanol and acetonitrile on nucleic acid separation. Methanol, and even better, acetonitrile improved the separation efficiency and shortened the analysis time.  相似文献   

13.
In an earlier study we showed that a blend of thermoresponsive and nonthermoresponsive hydroxyalkylcelluloses could be used to create a thermally tunable polymer network for double-stranded (ds) DNA separation. Here, we show the generality of this approach using a family of polymers suited to a wider range of DNA separations: a blended mixture of N,N-dialkylacrylamide copolymers with different thermoresponsive behaviors. A mixture of 47% w/w N,N-diethylacrylamide (DEA)/53% w/w N,N-dimethylacrylamide (DMA) (DEA47; thermoresponsive, transition temperature = 55 degrees C in water) and 30% w/w DEA/70% w/w DMA (DEA30; nonthermoresponsive, transition temperature > 85 degrees C in water) copolymers in the ratio of 1:5 w/w DEA47:DEA30 was used to separate a dsDNA restriction digest (PhiX174-HaeIII). We investigated the effects of changing mesh size on dsDNA separation, as controlled by temperature. We observed good DNA separation performance with the copolymer blend at temperatures ranging from 25 degrees C to 48 degrees C. The separation selectivity was evaluated quantitatively for certain DNA fragment pairs as a function of temperature. The results were compared with those obtained with a control matrix consisting only of the nonthermoresponsive DEA30. Different DNA fragment pairs of various sizes show distinct temperature-dependent selectivities. Over the same temperature range, no significant temperature dependence of selectivity is observed for these DNA fragment pairs in the nonthermoresponsive control matrix. Overall, the results show similar trends in the temperature dependency of separation selectivity to what was previously observed in hydroxyalkylcellulose blends, for the same DNA fragment pairs. Finally, we showed that a ramped temperature scheme enables improved separation in the blended copolymer matrix for both small and large DNA fragments, simultaneously in a single capillary electrophoresis (CE) run.  相似文献   

14.
Ion pair reverse phase high performance liquid chromatography on non-porous alkylated poly(styrene-divinylbenzene) particles enables the high resolution separation of double stranded DNA fragments. To further understand the separation mechanisms involved in ion pair reverse phase liquid chromatography we have analysed the effects of curved or "bent" DNA fragments with respect to their separation using both gel electrophoresis and ion pair reverse phase liquid chromatography. Size dependent separations of curved DNA fragments that migrate anomalously during gel electrophoresis were observed using ion pair reverse phase liquid chromatography. To further study the sequence effect and resulting changes in hydrophobicity of the duplex DNA, PCR fragments were generated that contain uracil in place of thymine. The resulting fragments were shown to elute with shorter retention times, demonstrating that sequence-specific effects can alter the retention of duplex DNA. The study was extended to the investigation of non-canonical B-DNA structures (Holliday junctions) under various chromatographic conditions, demonstrating that the coaxial stacking of the helices in such structures, in the presence of magnesium causes a change in retention.  相似文献   

15.
We describe the application of capillary electrophoresis to detect DNA fragments, obtained after amplifying a part of the apolipoprotein E (apoE) gene with polymerase chain reaction (PCR). Compared to conventional agarose slab gel electrophoresis (AGE), CE appears the method of choice with regard to resolution and sensitivity, to detect DNA fragments in the range of 20-100 base pairs. Especially discrimination between apoE2/E2 and apoE2/E3 genotypes is more reliable with CE than with AGE, this being of great clinical value in the diagnosis of familiary dysbetalipoproteinemia.  相似文献   

16.
Capillary gel electrophoresis (CGE) and polymer-based microelectrophoretic platforms were investigated to analyze low-abundant point mutations in certain gene fragments with high diagnostic value for colorectal cancers. The electrophoretic separations were carried out on single-stranded DNA (ssDNA) products generated from an allele-specific ligation assay (ligase detection reaction, LDR), which was used to screen for a single base mutation at codon 12 in the K-ras oncogene. The presence of the mutation generated a ssDNA fragment that was >40 base pairs (bp) in length, while the primers used for the ligation assay were <30 bp in length. Various separation matrices were investigated, with the success of the matrix assessed by its ability to resolve the ligation product from the large molar excess of unligated primers when the mutant allele was lower in copy number compared to the wild-type allele. Using CGE, LDR product models (44 and 51 bp) could be analyzed in a cross-linked polyacrylamide gel with a 1000-fold molar excess of LDR primers (25 bp) in approximately 45 min. However, when using linear polyacrylamide gels, these same fragments could not be detected due to significant electrokinetic biasing during injection. A poly(methylmethacrylate) (PMMA) microchip of 3.5 cm effective column length was used with a 4% linear polyacrylamide gel to analyze the products generated from an LDR. When the reaction contained a 100-fold molar excess of wild-type DNA compared to a G12.2D mutant allele, the 44 bp ligation product could be effectively resolved from unligated primers in under 120 s, nearly 17 times faster than the CGE format. In addition, sample cleanup was simplified using the microchip format by not requiring desalting of the LDR prior to loading.  相似文献   

17.
Huang MF  Hsu CE  Tseng WL  Lin YC  Chang HT 《Electrophoresis》2001,22(11):2281-2290
Separations of phiX-174/HaeIII DNA restriction fragments have been performed in the presence of electroosmotic flow (EOF) using five different polymer solutions, including linear polyacrylamide (LPA), poly(ethylene oxide) (PEO), hydroxypropylcellulose (HPC), hydroxyethylcellulose (HEC), and agarose. During the separation, polymer solutions entered the capillary by EOF. When using LPA solutions, bulk EOF is small due to adsorption on the capillary wall. On the other hand, separation is faster and better for the large DNA fragments (> 872 base pairs, bp) using derivative celluloses and PEO solutions. Several approaches to optimum resolution and speed by controlling EOF and/or altering electrophoretic mobility of DNA have been developed, including (i) stepwise changes of ethidium bromide (0.5-5 microg/mL), (ii) voltage programming (125-375 V/cm), (iii) use of mixed polymer solutions, and (iv) use of high concentrations of Tris-borate (TB) buffers. The DNA fragments ranging from 434 to 653 bp that were not separated using 2% PEO (8,000,000) under isocratic conditions have been completely resolved by either stepwise changes of ethidium bromide or voltage programming. Compared to PEO solutions, mixed polymer solutions prepared from PEO and HEC provide higher resolving power. Using a capillary filled with 600 mM TB buffers, pH 10.0, high-speed (< 15 min) separation of DNA (pBR 322/HaeIII digest, pBR 328/ Bg/l digest and pBR 328/Hinfl digest) has been achieved in 1.5% PEO.  相似文献   

18.
无胶筛分毛细管电泳分析几百个碱基对核酸的条件优化   总被引:1,自引:0,他引:1  
丁晓萍  廖杰  刘晓达  王全立  马立人 《色谱》1998,16(6):485-488
通过正交设计实验综合分析了内充羟丙基甲基纤维素(HPMC)无胶筛分毛细管电泳中的分离场强、HPMC浓度、柱长度和柱内径对核酸分离的影响。结果表明,柱长度越长、柱内径越小、分离场强越小,分离效果越好。考虑实际情况,为能在短时间内使几百个碱基对的核酸得到有效分离,一般选择37cm×75μmi.d.的涂壁毛细管、柱内质量浓度为8g/L的HPMC、场强为324V/cm的条件,并在此种条件下分析了ApoB100基因的低浓度聚合酶链式反应(PCR)扩增产物(710bp)。  相似文献   

19.
Tseng WL  Chang HT 《Electrophoresis》2001,22(4):763-770
DNA separations were performed in poly(ethylene oxide) (PEO) solutions prepared in 100 mM Tris-boric acid (TB) buffers using a capillary filled with TB buffers with concentrations up to 2.5 M, pH 10.0. The electroosmotic flow (EOF) increased with increasing the concentration of TB buffers till 1.5 M as a result of decreasing PEO adsorption on the capillary wall. At high TB concentrations (> 1.5 M), the peaks corresponding to small DNA fragments (11 and 8 base pairs) became sharper and were detected. Relative standard deviations of the EOF coefficient and the migration times of the DNA fragments were all less than 1% using a capillary filled with TB buffers at concentrations higher than 1.5 M. When separations were performed at different pH values of PEO solutions and TB buffers, better results in terms of sensitivity, speed, and resolution were generally achieved. The fluorescence intensity of the 2176 bp fragment obtained at pH values of TB buffers/PEO solutions 10.0/8.2 was 27-fold of that at pH values 8.2/8.2. The enhancement was related to effects of pH and borate on fluorescence intensity, DNA conformation, stacking, and interactions with the capillary wall. Using a capillary filled with 400 mM TB buffers, pH 10.0, the separation of DNA (pBR 322/HaeIII digest, pBR 328/Bg/I digest and pBR 328/HinfI digest) in 1.5% PEO solutions prepared in 100 mM TB buffers, pH 9.0, at 375 V/cm was accomplished in less than 18 min.  相似文献   

20.
Accurate quantification of DNA is highly important in various fields. Determination of phosphorus by ICP-MS is one of the most effective methods for accurate quantification of DNA due to the fixed stoichiometry of phosphate to this molecule. In this paper, a smart and reliable method for accurate quantification of DNA fragments and oligodeoxythymidilic acids by hyphenated HPLC/ICP-MS equipped with a highly efficient interface device is presented. The interface was constructed of a home-made capillary-attached micronebulizer and temperature-controllable cyclonic spray chamber (IsoMist). As a separation column for DNA samples, home-made methacrylate-based weak anion-exchange monolith was employed. Some parameters, which include composition of mobile phase, gradient program, inner and outer diameters of capillary, temperature of spray chamber etc., were optimized to find the best performance for separation and accurate quantification of DNA samples. The proposed system could achieve many advantages, such as total consumption for small amount sample analysis, salt-tolerance for hyphenated analysis, high accuracy and precision for quantitative analysis. Using this proposed system, the samples of 20 bp DNA ladder (20, 40, 60, 80, 100, 120, 140, 160, 180, 200, 300, 400, 500 base pairs) and oligodeoxythymidilic acids (dT12–18) were rapidly separated and accurately quantified.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号