首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method has been developed for photometric detection of cyclodextrins (CD) in liquid chromatography using iodine (I2) generated electrochemically in-situ. Iodide ion in the mobile phase was electrochemically oxidized to I2 which was subsequently reacted with I, in an electrochemical flow cell, forming I3. The absorbance of I3 was found to be greatly enhanced when CD were present in the mobile phase. The absorbance enhancement was caused by the change in the mole fraction of I3, because of the inclusion reaction of I3 with CD. On the basis of this phenomenon, CD were detected by means of a photodiode-array UV–visible detector positioned downstream of the electrochemical flow cell. The signals were found to be linearly dependent on CD concentration. Because the formation constants of I3 with CD decrease in the order -CD>-CD>-CD, -CD was most detectable by the method. Detection limits were 1.0 mol L–1 for -CD, 65 mol L–1 for monoG1--CD, 100 mol L–1 for -CD, and 200 mol L–1 for -CD.  相似文献   

2.
    
Zusammenfassung Es werden Erfahrungen mit der Kombination von automatischem Aminosäurenanalysator und Szintillations-Durchflußzelle zur Bestimmung der spezifischen Radioaktivität 14C-markierter Aminosäuren im Gehirn mitgeteilt. Die Erfassungsgrenze beträgt 3 · 10–4 Ci/ml Eluat, die Reproduzierbarkeit 5–1% vom Mittelwert im Meßbereich von 1 · 10–3 bis 5 · 10–2 Ci.
A method for the determination of the specific radioactivity of free amino-acids in tissue extracts of mammals
Some experiences are given with a measuring device for the determination of the specific radioactivity of 14C-labelled brain amino-acids. The apparatus consists of an automatic amino-acid analyzer combined with a flow cell filled with anthracene. The reproducibility of the method is ±5% to ±1% m.e. in the range of 1×10–3 Ci to 5×10–2 Ci. A quantitative determination of 3×10–4 Ci/ml eluant is still possible.
  相似文献   

3.
A high-performance thin layer chromatographic method coupled with densitometric analysis has been developed for measurement of benazepril and cilazapril, both pure and in their commercial dosage forms. The active substances were extracted from tablets with methanol (mean recovery 102%) and chromatographed on silica gel 60 F254 HPTLC plates in horizontal chambers with ethyl acetate–acetone–acetic acid–water, 8:2:0.5:0.5 (v/v), as mobile phase. Chromatographic separation of these ACE inhibitors was followed by UV densitometric quantitation at 215 nm. Calibration plots were constructed in the range 0.4 to 2.0 g L–1 for benazepril (2.0–10.0 g spot–1) and from 0.5 to 1.5 g L–1 for cilazapril (4.0–12.0 g spot–1) with good correlation coefficients (r 0.990). The method was used to determine benazepril and cilazapril in pharmaceutical preparations with satisfactory precision (1.4% < RSD < 5.6%) and accuracy (1.7 < RE < 5.1).  相似文献   

4.
An upper bound can be set to the dipole moment of the X-H bond (with X+H polarity) for symmetrical molecules of XH4 and XH3 type from the experimental values of the g factor and bond length. The following upper bounds have been found to the bond dipole moments: CH4 (C+H<0.902 D, SiH4, (Si+H)<4.21 D, GeH4+ (Ge+H)<3.59 D, NH3 (N+H)<0, PH3 (P+H)<2.74 D. These results enable one to rule out certain published data on the dipole moment of the C-H bond in methane as certainly incorrect. In the case of the ammonia molecule, the possibility of N+H polarity is ruled out.Translated from Teoreticheskaya i Éksperimental'naya Khitniya, No. 3, pp. 346–350, May–June, 1985.  相似文献   

5.
A method, based on the measurement of the -photopeak at 332 keV arising from a124Sn(n, )125mSn reaction, has been developed for the rapid measurement of Sn at concentrations of 20 g g–1, present as the cross-linking agent, in explosive charges. The method is comparative, and has a limit of detection of 0.6 g g–1 and a precision of 5% RSD. The method requires no sample preparation and is economical in effort.  相似文献   

6.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

7.
The aim of the present study was to develop a sensitive method to measure dextromethorphan and dextrorphan in urine by HPLC to support pharmacogenetic studies in ethnic groups. Linearity was assessed in the range: 0.015–10 g mL–1 for dextromethorphan and 1-10 g mL–1 for dextrorphan. Inter and intra-day coefficients of variation were < 10%. Limits of detection and quantitation were 0.003 g mL–1 and 0.015 g mL–1 for dextromethorphan and 0.24 g mL–1 and 1.0 g mL–1 for dextrorphan, respectively. The method is reliable in helping determine the phenotype of Mexican ethnic groups using model drugs such as dextromethorphan.  相似文献   

8.
Summary A simultaneous capillary Gas Chromatographic-Mass Spectrometric (GC-MS) method is described for the determination of thirteen pesticides belonging to the triazine and amide families in water. The sample is extracted in liquid-liquid mode (dichloromethane) and then the determination of the residues is carried out by capillary gas chromatography with mass spectrometric detection in the Selected-Ion Monitoring mode (SIM). The average recoveries of spiked compounds are in the 78.4–135.4% range between the relative low level (0.100 g L–1) and the relative high level (10.0 g L–1). The limits of detection (LOD) are in the 0.009–0.128 g L–1 range.  相似文献   

9.
Summary Two packing materials, C18 and PLRP-S, are studied for on-line trace enrichment of phenolic compounds in water. Various precolumns of different internal diameter are also tested and the addition of an ion-pair reagent to increase retention and thus, breakthrough volumes of phenolic compounds, is studied. Best results are obtained when a PLRP-S precolumn is coupled on-line with a C18 analytical column and DAD detector. Addition of TBA considerably increases breakthrough volumes. In contrast, when a C18 precolumn is used, breakthrough volumes are lower and it is impossible to determine TCP and PCP, under the experimental conditions used, because of interference of other nonpolar compounds in the samples. The performance of the system is evaluated with river and tap water and the preconcentration of 10 ml of sample in a PLRP-S precolumn involves a linear range between 1 g 1–1 and 20 l–1 and limits of determination between 0.5 g l–1 and 1 g l–1 are obtained.  相似文献   

10.
Summary A simple multi-residue procedure has been developed and applied to the analysis of pesticides in groundwater samples from the Comunidad Valenciana, a predominantly agricultural area on the Mediterranean coast of Spain. The procedure includes a liquid-liquid extraction, after addition of NaCl on the samples, and a subsequent analysis by capillary gas chromatography using a dual detection system with electron capture and nitrogen-phosphorous detectors. This allows the determination of more than 30 compounds (organophosphorous, organochlorine and pyrethroid pesticides) at the low ppb (g l–1) levels. Detection limits obtained varied between 0.01 g l–1 (lindane, fonofos) and 0.5 g l–1 (cypermethrin). An additional injection of the sample extracts into a gas chromatograph equipped with a column of different polarity and electron capture detector is used for the confirmation of chromatographic peaks. The recommended procedure has been applied to 66 ground water samples. Pesticides, including organophosphorus and organochlorine compounds were detected in 31 of them, in levels ranging from 0.02 to 0.7 g l–1.  相似文献   

11.
ET-AAS is investigated for the analysis of high purity mercury. Two possibilities are proposed: ET-AAS determination of trace analytes in the presence of high mercury concentrations or after matrix separation by reduction. The ET-AAS analysis of high-purity mercury under optimal instrumental parameters permits fast and reproducible determination of 0.03 gg–1 Al, Cd and Mn; 0.05 gg–1 Cu, Co, Cr, Fe, Ni and Pb and 0.2 gg–1 V. Preliminary mercury matrix reductive separation with ascorbic acid allows determination of 0.005 gg–1 Cd, 0.02 gg–1 Cu, Cr and Mn, 0.03 g g–1 Co, Ni and Pb, 0.05 g g–1 Al and Fe and 0.1 gg–1 V, but the reproducibility is lower. The main advantage of the second procedure is that it avoids laboratory and instrument pollution with toxic mercury.  相似文献   

12.
The interference contributions of uranium and thorium to the determination of cerium based on radionuclides141Ce and143Ce produced by irradiation in a reactor core was determined. The values of the interference contributions for141Ce were 0.28±0.01 g Ce/g U and /2.01±0.05/x10–3 g Ce/g Th, and for143Ce 1.33±0.03 g Ce/g U and /9.0±0.2/x10–3 g Ce/g Th.  相似文献   

13.
The determination of trace metals, e.g. Bi, Cd, Pb, in high-purity aluminium, zinc and commercial steel by flame or graphite furnace atomic absorption spectrometry following their preconcentrations as iodo complexes on XAD-1180 resin by means of a short column system is described. The recoveries are quantitative (95%). The relative standard deviations varies between 6% and 10%. The relative errors are less than 8% in a concentration range of 1 × 10–3 –4 × 10–5%. Detection limits for flame AAS and GFAAS were in the ranges of 0.002–0.110 g/ml and 0.0003–0.004 g/ml or in the ranges of 0.08–4.40 g/g and 0.012–0.16 g/g with respect to the solid samples, respectively.  相似文献   

14.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

15.
The characteristics of knitted open tube (KOT) figure eight reactors and coil reactors at l/min flow rates were compared using plate height (H) calculations and peak height measurements. Peak broadening independent of flow rate was seen for the figure eight KOT but not the coil at flow rates of 150–300 l/min. Below 150 /min, the plate height values of both reactors were inversely proportional to flow rate. It was concluded that a 0.5-m KOT figure eight reactor is the most effective way to introduce delay time for a 1 1 injection size and tubing of 0.3 mm I.D. Enhancement of peak height response was particularly pronounced at flow rates less than 100 l/min.  相似文献   

16.
The absolute concentrations of iodine, bromine and chlorine in milk, have been determined by epithermal neutron activation followed by high resolution gamma-ray spectrometry. Two kinds of milk commonly consumed in Israel have been investigated. The concentration of iodine, bromine and chlorine were found to be 0.18–0.30 g/ml, 2.02–2.85 g/ml and 0.65 mg/ml, respectively. The method is fast, selective, accurate and highly sensitive.  相似文献   

17.
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to determine the concentration of platinum (Pt) in silicone breast implant gel (range, 0.26–48.90 g g–1 Pt; n=15), elastomer (range, 3.05–28.78 g g–1 Pt; n=7), double lumen (range, 5.79–125.27 g g–1 Pt; n=7), foam (range, 5.79–8.36 g g–1 Pt; n=2), and capsular tissue (range, 0.003–0.272 g g–1 Pt; n=15). The results show that very high levels of Pt are present in the encasing elastomer, double lumen, and foam envelope materials. Silicone breast implants can be a source of significant Pt exposure for individuals with these implants.  相似文献   

18.
Arsenic in sea water was determined directly by graphite furnace atomic absorption spectrometry (GFAAS) using palladium nitrate as chemical modifier, at an optimum concentration of 15 mg l–1. Deuterium and Zeeman effect background correction were compared and gave detection limits of 0.6 and 0.8 g l–1, respectively. Precisions between 8 and 2%, for both correctors, were obtained with an injection volume of 40 l. The accuracy obtained with different reference materials: CRM-403 (1.461 g kg–1), NASS-4 (1.26 ±0.09 gl–1) and IAEA/W-4 (24–31 g l–1) was studied for large injection volumes for both background correction systems. Interferences by chloride, sodium, potassium, calcium and silicon were removed by Zeeman correction, whereas deuterium correction was much less effective and was insufficiently accurate for sea water samples.  相似文献   

19.
Summary Laser microprobe mass analysis (LAMMA) was applied to characterize aerosol particles collected and separated from 16m to 0.06m by a low pressure cascade impactor. Positive ion LAMMA spectra showed characteristic molecular peaks such as PbCl+, a series of Si2O+–Si2O4 + and NaAl2Si2O2 +–NaAl2Si2O5 +, and TiO+ in 0.06–0.12m, 0.5–1m and 4–8m fraction, respectively. In the negative ion LAMMA spectra, it was observed that the fragment peaks of sulfate ions were deficient above 2m and those of nitrate ions were deficient under 2m. LAMMA allows remarkable insights into the chemical nature of aerosol particles.
Charakterisierung luftgetragener Teilchen durch Laser-Microprobe-Massenspektrometrie
Zusammenfassung Laser-Microprobe-Spektrometrie (LAMMS) wurde zur Analyse atmosphärischen Aerosols herangezogen, welches im Korngrößenbereich zwischen 16m und 0.06m mit einem Niederdruckkaskadenimpaktor fraktioniert gesammelt wurde. Positive LAMMS-Spektren zeigten charakteristische molekulare Peaks, wie etwa PbCl+, eine Serie von Si2O+–Si2O4 + und NaAl2Si2O2 +–NaAl2Si2O5 +, sowie TiO+ in der 0,06–0,12-m,- 0,5–1–m- bzw. 4–8-m-Fraktion. In den negativen LAMMS-Spektren konnten über 2m keine Fragmentpeaks für Sulfationen, unter 2m. keine für Nitrationen beobachtet werden. LAMMS ermöglicht eine bemerkenswerte Einsicht in die chemische Natur von Aerosolteilchen.
  相似文献   

20.
The effect of cationic surfactants (cetyltrimethylammonium bromide, cetylpyridinium bromide, and tetrabutylammonium perchlorate) and a nonionic surfactant (OP-7) on the conditions of the immobilization of 4-(2-pyridylazo)resorcinol (PAR) on three types of silica gel (Silochrom S-120 (200–350 m), Silochrom S-120 (315–500 m), and Silochrom S-80 (200–350 m)) was studied. It was found that OP-7 does not affect the adsorption of surfactants. The effect of cationic surfactants increases in the order tetrabutylammonium perchlorate < cetyltrimethylammonium bromide < cetylpyridinium bromide. The adsorption activity of silica gels increases in the order Silochrom S-120 (315–500 m) < Silochrom S-80 (200–350 m) < Silochrom S-120 (200–350 m). Cetylpyridinium bromide provides full immobilization of PAR on silica gel Silochrom S-120 (200–350 m) in the pH range 2–9.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号