首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到9条相似文献,搜索用时 0 毫秒
1.
Moderately uniform magnetic poly(methylmethacrylate–divinylbenzene–glycidylmethacrylate) microspheres (poly(MMA–DVB–GMA) microspheres) were prepared by spraying suspension copolymerization of methyl methacrylate, divinylbenzene and glycidyl methacrylate in the presence of Fe3O4 magnetic fluid. A protein adsorption assay indicated that these magnetic microspheres could significantly improve the capacity of protein adsorption.  相似文献   

2.
Plasma surface modification can be used to improve the surface properties of commercial pure Ti by creating functional groups to produce bioactive materials with different surface topography. In this study, a titanium surface was modified with acrylic acid (AA) using a plasma treatment and immobilized with bioactive arginine-glycine-aspartic acid (RGD) peptide, which may accelerate the tissue integration of bone implants. Both terminals containing the -NH2 of RGD peptide sequence and -COOH of poly(acrylic acid) (PAA) thin film were combined with a covalent bond in the presence of 1-ethyl-3-3-dimethylaminopropyl carbodiimide (EDC). The chemical structure and morphology of AA film and RGD immobilized surface were investigated by X-ray photoelectron spectroscopy (XPS), Fourier transform infrared (FT-IR), atomic force microscopy (AFM), and scanning electron microscopy (SEM). All chemical analysis showed full coverage of the Ti substrate with the PAA thin film containing COOH groups and the RGD peptide. The MC3T3-E1 cells were cultured on each specimen, and the cell alkaline phosphatase (ALP) activity were examined. The surface-immobilized RGD peptide has a significantly increased the ALP activity of MC3T3-E1 cells. These results suggest that the RGD peptide immobilization on the titanium surface has an effect on osteoblastic differentiation of MC3T3-E1 cells and potential use in osteo-conductive bone implants.  相似文献   

3.
This contribution demonstrates a synthesis of comb polymer consisting of a poly(epichlorohydrin) (PECH) backbone and poly(oxyethylene methacrylate) side chains. Atom transfer radical polymerization (ATRP) was used to directly initiate the chlorine atoms of PECH macroinitiator. The structure of comb polymer was characterized by nuclear magnetic resonance (1H nuclear magnetic resonance) and Fourier transform infrared (FT-IR) spectroscopy, presenting the successful “grafting from” method using ATRP. The comb polymer was used as a polymer matrix for dissolving potassium iodide (KI) to prepare solid polymer electrolyte. FT-IR spectroscopy indicates that the potassium salts are dissolved in the polymeric matrix due to coordination interaction with the ether oxygens of graft copolymer. Differential scanning calorimetry showed that glass transition temperature (T g) of polymer electrolytes continuously increased with increasing salt concentration up to 15 wt.%, mostly due to coordinative interactions between the potassium ions and the ether oxygens of polymer matrix. Ionic conductivity at room temperature increased with increasing salt concentrations up to 5 wt.% (maximum ionic conductivity ~3.7 × 10−5 S/cm), after which it gradually decreased.  相似文献   

4.
Melting points in mixtures of a crystallizable polymer with a low-molar-mass diluent depend on both, the diluent fraction and the crystal thickness. A differentiation of the two factors can be achieved by temperature-dependent SAXS experiments. A corresponding study, complemented by DSC, dilatometry, microscopy and AFM-imaging, was carried out for mixtures of a poly(ethylene-co-octene) with n-C16H34, c-C16H32 and methyl-anthracene, respectively. All diluents lead for a constant crystal thickness to melting point depressions in agreement with Raoult's law. On the other hand, the effect of the diluents on the thickness of the crystals formed at a fixed crystallization temperature varies. While in the presence of the two alkanes thicker crystals form, no effect arises for the methyl-anthracene—as was previously found for the octene-co-units. We consider these observations as a further support for our view that polymer crystallization follows a multi-stage route which includes a passage through an intermediate mesomorphic phase. Under such conditions crystal thicknesses would only be affected if the diluent is still present in the mesomorphic phase and stay invariant if the diluent molecules are already rejected when this intermediate phase forms.  相似文献   

5.
Laser-induced forward transfer (LIFT) of the enzyme luciferase was explored as a potential technique to be used in the fabrication of a microchip adenosine triphosphate (ATP) sensor. Poly(dimethylsiloxane) (PDMS) was selected as the substrate for deposition of the luciferase. In comparison with other solid substrates, such as glass and polystyrene, it was found that the flexibility of PDMS made it a superior substrate for the immobilization of micro-spots of luciferase. LIFT of luciferase onto a PDMS substrate using a 355 nm laser was successfully carried out, while the bioactivity of the enzyme was maintained. Yellow luminescence ascribed to luciferase was observed from a transferred spot on the PDMS chip from the enzymatic reaction between luciferin and ATP. A microchip ATP sensor was also fabricated by attaching a small photodiode to the PDMS chip. On the basis of the fabricated microchip, the Michaelis-Menten relation between the luminescence intensity from the spot, and the ATP concentration was confirmed. The potential for fabricating biosensors using a combination of the LIFT technique with a PDMS substrate was shown to be very good.  相似文献   

6.
Poly(vinylalcohol) (PVA) nanofibers containing gold nanoparticles have been simply obtained by electrospinning a solution containing gold nanoparticles without the additional step of introducing other stabilizing agents. The optical property of gold nanoparticles in PVA aqueous solution was observed by UV-visible absorption spectra. Morphology of the Au/PVA nanofibers and distribution of the gold nanoparticles were characterized by transmission electron microscopy (TEM). The structure transformation was characterized from PVA to PVA/Au composite by Fourier transform infrared spectroscopy (FTIR).  相似文献   

7.
A.Abdel Moez  Ahmed I.Ali  A.Tayel 《中国物理 B》2022,31(1):18103-018103
Ca12Al14O33(C12A7)and Y0.02Ca11.98Al14O33(Y-C12A7)single crystals were grown by using the traveling-solvent floating zone(TSFZ)method.The temperature was increased to avoid the bubbles and cracks which may be formed during the preparation of the ingot material.We have started with the flux higher than the normal to avoid the bubbles and make good treatment for the solid-liquid interface.The structures of both Ca12Al14O33(C12A7)and Y0.02Ca11.98Al14O33(Y-C12A7)were studied by using x-ray diffraction(XRD).Optical properties for C12A7 and Y-C12A7 single crystals have been studied in order to determine the optical parameters such as optical energy gap(Eg),refractive index n,oscillating energy(Eo),dispersion energy(Ed),volume energy loss function(VELF),and surface energy loss function(SELF).Finally,a new result for these samples is that the third-order nonlinear optical susceptibility(χ(3))was determined.The results have been discussed with effect of Y-doping on the C12A7 single crystals for optical and industrial applications.  相似文献   

8.
A method has been developed for calculating the expected fluorescence lifetime of the DPH p PC probe distributed between different membrane environments. We show how this method can be used to distinguish between lipid transfer and fusion between large unilamellar vesicles occurring in the presence of poly(ethylene glycol) (PEG). This application of the calculation took into consideration the heterogeneity of microenvironments experienced by the probe in a sample containing vesicle aggregates of different sizes. Assuming that the aggregate size distribution was a delta function of the aggregate size, comparison of the calculated and observed lifetimes yielded an estimate of the vesicle aggregate size. For vesicles of varying compositions in the presence of dehydrating concentrations of PEG, this method suggested that only small aggreggates formed. For vesicles that could be demonstrated by other means not to have fused, the data were consistent with lipid transfer occurring only between the outer leaflets of two to four vesicles, even at high PEG concentrations. For vesicles that could be demonstrated to fuse by contents mixing and size changes, the fluorescence lifetime data were consistent with lipid transfer between both the inner and the outer leaflets of two to four fused vesicles. At very high PEG concentrations, where extensive rupture and large, multilamellar products were previously observed, the lifetime data were consistent with much more extensive lipid transfer within larger aggregates. The agreement of predictions made on the basis of lifetime measurements with other observations attests to the validity of the fluorescence lifetime method. In addition, the model and data presented here provide evidence that fusion occurs between small numbers of PEG-aggregated vesicles before the removal of PEG.  相似文献   

9.
The acquisition and different appearances observed for wide bandwidth solid-state MAS NMR spectra of low-γ nuclei, using (14)N as an illustrative nucleus and employing two different commercial spectrometers (Varian, 14.1T and Bruker, 19.6T), have been compared/evaluated and optimized from an experimental NMR and an electronic engineering point of view, to account for the huge differences in these spectra. The large differences in their spectral appearances, employing the recommended/standard experimental set-up for the two different spectrometers, are shown to be associated with quite large differences in the electronic design of the two types of preamplifiers, which are connected to their respective probes through a 50Ω cable, and are here completely accounted for. This has led to different opportunities for optimum performances in the acquisition of nearly ideal wide bandwidth spectra for low-γ nuclei on the two spectrometers by careful evaluation of the length for the 50Ω probe-to-preamp cable for the Varian system and appropriate changes to the bandwidth (Q) of the NMR probe used on the Bruker spectrometer. Earlier, we reported quite distorted spectra obtained with Varian Unity INOVA spectrometers (at 11.4 and 14.1T) in several exploratory wide bandwidth (14)N MAS NMR studies of inorganic nitrates and amino acids. These spectra have now been compared/evaluated with fully analyzed (14)N MAS spectra correspondingly acquired at 19.6T on a Bruker spectrometer. It is shown that our upgraded version of the STARS simulation/iterative-fitting software is capable of providing identical sets for the molecular spectral parameters and corresponding fits to the experimental spectra, which fully agree with the electronic measurements, despite the highly different appearances for the MAS NMR spectra acquired on the Varian and Bruker spectrometers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号