首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A nonenzymatic amperometric sensor for sensitive and selective detection of glucose has been constructed by using highly dispersed Pt nanoparticles supported onto mesoporous carbons (MCs). The Pt nanoparticles/mesoporous carbons (Pt/MCs) composites modified electrode displayed high electrocatalytic activity towards the oxidation of glucose. At an applied potential of 0.1 V, the Pt/MCs electrode has a linear dependence (R=0.996) in the glucose concentration up to 7.5 mM with a sensitivity of 8.52 mA M?1 cm?2. The Pt/MCs electrode has also shown highly resistant toward poisoning by chloride ions and without interference from the oxidation of common interfering species.  相似文献   

2.
PtRu nanoparticles were supported on multiwall carbon nanotubes (MWNTs), which were further fabricated as an electrode for nonenzymatic glucose sensing. Transmission electron microscope and X‐ray diffraction patterns were used for characterization of the PtRu nanoparticles on MWNTs. Cyclic voltammetry and chronopotentiometry were applied to investigate the performance of the PtRu/MWNTs nanocomposite electrode for nonenzymatic oxidation of glucose. The PtRu/MWNTs electrode shows high electrocatalytic activity towards the oxidation of glucose in 0.1 M NaOH solution and thus can be used to selectively detect glucose. Under the optimal potential (+0.55 V vs. Ag/AgCl), the biosensor effectively performs a selective electrochemical analysis of glucose in the presence of common interferents, such as ascorbic acid (AA), dopamine (DP) and uric acid (UA). Wide linear calibration ranging from 1 mM to 15 mM, high sensitivity of 28.26 μA cm?2 mM?1, low detection limit of 2.5×10?5 M, and fast response time of 10 s were achieved for the detection of glucose at the PtRu/MWNTs electrode.  相似文献   

3.
Herein, we have demonstrated a preparation of palladium nanoparticles on electroactivated graphite nanosheets modified screen printed carbon electrode (PdNPs‐EGNS/SPCE) by a simple electrochemical method. The well‐prepared electrocatalyst was potentially applied to the high performance electrocatalytic oxidation of hydrazine in neutral medium. The PdNPs‐EGNS novel composite was characterized by scanning electron microscope (SEM) and the average diameter and thickness of PdNPs and EGNS were found to be ~38 nm and 85 nm, respectively. The high performance electrocatalytic determination of hydrazine was performed by the amperometric i‐t method. The fabricated sensor displayed irreversible electrocatalytic oxidation of hydrazine with diffusion‐controlled electrode process. The oxidation of hydrazine at PdNPs‐EGNS/SPCE showed wider linear range 0.05–1415 µM and high sensitivity 4.382 µA µM?1 cm?2. The as‐prepared electrocatalyst achieved quick response towards hydrazine with a lower detection limit 4 nM.  相似文献   

4.
Titanium dioxide nanoparticle/gold nanoparticle/carbon nanotube (TiO2/Au/CNT) nanocomposites were synthesized, and then characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy dispersive X-ray spectroscopy (EDX). A TiO2/Au/CNT nanocomposite-modified glassy carbon (GC) electrode was prepared using the drop coating method and was investigated using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), differential pulse voltammetry (DPV), and amperometric current–time response (I-T). The modified material is redox-active. The nonenzymatically detected amount of ascorbic acid (AA) on the TiO2/Au/CNT electrode showed a linear relationship with the AA concentration, for concentrations from 0.01 to 0.08 μM; the sensitivity was 117,776.36 μA?·?cm?2?·?(mM)?1, and the detection limit was 0.01 μM (S/N?=?3). The results indicated that the TiO2/Au/CNT nanocomposite-modified GC electrode exhibited high electrocatalytic activity toward AA. This paper describes materials consisting of a network of TiO2, Au, and MWCNTs, and the investigation of their synergistic effects in the detection of AA.  相似文献   

5.
Novel CuO thin films composed of porous nanosheets were in situ formed on indium tin oxide (ITO) by a simple, low temperature solution method, and used as working electrodes to construct nonenzymatic glucose sensor after calcinations. Cyclic voltammetry revealed that the CuO/ITO electrode calcinated at 200 °C exhibited better electrocatalytic activity for glucose. For the amperometric glucose detection, such prepared electrode showed low operating potential of 0.35 V and high sensitivity of 2272.64 μA mM?1 cm?2. Moreover, the CuO/ITO electrode also showed good stability, reproducibility and high anti‐interference ability. Thus, it is a promising material for the development of non‐enzymatic glucose sensors.  相似文献   

6.
易清风  黄武  于文强  李磊  刘小平 《中国化学》2008,26(8):1367-1372
利用电热法,一步制备出新型的钛基Ni-Sn/Ti电极(Ni8Sn/Ti, Ni7Sn3/Ti 和 Ni/Ti)。扫描电镜(SEM)图像表明,催化剂以片状的纳米颗粒形式沉积于钛基体上。利用电化学伏安技术、电位阶跃法和电化学交流阻抗谱(EIS),研究了这些电极在1mol.L�1NaOH溶液中对甲醇氧化反应的电催化活性。研究表明,与Ni7Sn3/Ti,Ni/Ti以及多晶镍电极相比,Ni8Sn/Ti电极对甲醇氧化反应表现出更高的阳极氧化电流和更低的起始电位。EIS分析表明,在本文所考察的阳极电位和甲醇浓度下,Ni8Sn/Ti电极对甲醇氧化反应显示出极低的电荷传递电阻。结果表明,这种新型的钛基Ni8Sn/Ti电极对甲醇氧化反应具有极高的电催化活性。  相似文献   

7.
Prussian blue nanoparticles (PBNPs) were prepared by a self‐assembly process on a glassy carbon electrode (GCE) modified with poly(o‐phenylenediamine) (PoPD) film. The stepwise fabrication process of PBNP‐modified PoPD/GCE was characterized using scanning electron microscopy and electrochemical impedance spectroscopy. The prepared PBNPs showed an average size of 70 nm and a homogeneous distribution on the surface of the modified electrode. The PBNPs/PoPD/GCE showed electrocatalytic activity towards the oxidation of pyridoxine (PN) and was used as an amperometric sensor. The modified electrode exhibited a linear response for PN oxidation over the concentration range 3–38.5 μM with a detection limit of ca 6.10 × 10?7 M (S/N = 3) and sensitivity of 2.79936 × 103 mA M?1 cm?2 using an amperometric method. The mechanism and kinetics of the catalytic oxidation reaction of PN were investigated using cyclic voltammetry and chronoamperometry. The values of α, kcat and D were estimated as 0.36, 1.089 × 102 M?1 s?1 and 8.9 × 10?5 cm2 s?1, respectively. This sensor also exhibited good anti‐interference and selectivity. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
A non-enzymatic sensor was developed for the determination of glucose in alkaline medium by anodisation of copper in sodium potassium tartrate solution. The morphology of the modified copper electrode was studied by scanning electron microscopy, and its electrochemical behavior by cyclic voltammetry and electrochemical impedance spectroscopy. The electrode enables direct electrocatalytic oxidation of glucose on a CuO/Cu electrode at 0.7 V in 0.1 M sodium hydroxide. At this potential, the sensor is highly selective to glucose even in the presence of ascorbic acid, uric acid, or dopamine which are common interfering species. The sensor displays a sensitivity of 761.9 μA mM?1 cm?2, a linear detection range from 2 μM to 20 mM, a response time of <1 s, and a detection limit of 1 μM (S/N = 3). It was tested for determination of glucose level in blood serum.  相似文献   

9.
Diphenylamine (DPA) monomers have been electropolymerized on the amino‐functionalized multiwalled carbon nanotube (AFCNT) composite film modified glassy carbon electrode (GCE) by cyclic voltammetry (CV). The surface morphology of PDPA‐AFCNT was studied using field‐emission scanning electron microscopy (FE‐SEM). The interfacial electron transfer phenomenon at the modified electrode was studied using electrochemical impedance spectroscopy (EIS). The PDPA‐AFCNT/GCE represented a multifunctional sensor and showed good electrocatalytic behavior towards the oxidation of catechol and the reduction of hydrogen peroxide. Rotating‐disk electrode technique was applied to detect catechol with a sensitivity of 1360 µA mM?1 cm?2 and a detection limit of 0.01 mM. Amperometric determination of hydrogen peroxide at the PDPA‐AFCNT film modified electrode results in a linear range from 10 to 800 µM, a sensitivity of 487.1 µA mM?1 cm?2 and detection limit of 1 µM. These results show that the nano‐composite film modified electrode can be utilized to develop a multifunctional sensor.  相似文献   

10.
A nonenzymatic glucose sensor was successfully established by electrochemically decorating cobalt oxides (CoOx) on a nanoporous gold electrode (NPG) using cobalt hexacyanoferrate (CoHCF) as a precursor. It exhibited high sensitivity and long‐term stability as well as satisfactory quantification of glucose concentration in human serum samples. The morphology and surface analysis of the resulting CoOx/NPG were carefully characterized. Two detection methods, cyclic voltammetry and amperometry, were employed to evaluate the performance of CoOx/NPG towards glucose sensing in alkaline solution. Using cyclic voltammetry, at ?0.5 V, the glucose partial oxidation peak current is linear to the glucose concentration up to 14 mM with a sensitivity of 283.7 µA mM?1 cm?2. A linear amperometric response at 0.55 V was obtained in the glucose concentration range from 2 µM to 2 mM with a sensitivity of 2025 µA mM?1 cm?2 and a response time <3 s.  相似文献   

11.
Commercially available copper foam (CF) was used as a 3D porous electrochemical sensing platform for nonenzymatic glucose detection. CF shows high electrocatalytic activity towards glucose oxidation and can be used directly for glucose electrochemical sensing without any pretreatment. The sensor exhibits high performance towards glucose in 0.1 M NaOH solution with the linear range from 1 μM to 0.5 mM, the sensitivity of 5.85 mA mM?1 cm?2 and the detection limit of 0.5 μM (S/N=3) simultaneously. Furthermore, the sensor shows a high selectivity for glucose against the common interferences and good reliability for glucose detection in human serum samples.  相似文献   

12.
In this study, an available and inexpensive graphite substrate, was easily modified with Ni/Cr nanoparticles via electrodeposition technique in a very short time (3 min) and used as an electrocatalyst for glucose oxidation in alkaline solution. Graphite electrode modified with Ni/Cr nanoparticles demonstrated an outstanding electrocatalytic performance to glucose oxidation in comparison to examined Ni‐based electrodes or even different materials in other reports. It is noteworthy to mention that adding a little Cr led to a synergistic effect with Ni; accordingly, the presence of Cr not only resulted in a greater adsorption of glucose molecules by chromium oxide but also boosted conductivity of the nickel oxide because of the enhancement of Ni(III) amount. The electrochemical studies were performed by cyclic voltammetry and electrochemical impedance spectroscopy (EIS). The morphology and structure of catalyst layer was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), X‐ray diffraction (XRD) and energy dispersive x‐ray spectroscopy (EDS). The linear range of the electrode by cyclic voltammetry was between 2–31 mM with a high sensitivity of 2094 μA cm?2 mM?1. The repeatability and reproducibility of the proposed electrode was examined in glucose solution which were 0.3 % and 4.7 %, respectively. According to the low cost, ease and fast preparation, good repeatability and high sensitivity, this electrode can be a good candidate for nonenzymatic glucose oxidation.  相似文献   

13.
The electrocatalytic and analytical ability to glucose on a highly dispersed Pt nanoparticles supported on active carbon (Pt/C) modified electrode was investigated. The Pt/C nanocomposite was synthesized using a microwave method. The structural characterization and surface morphology of the prepared Pt/C nanocomposite was examined using X-ray diffraction, energy-dispersive X-ray, scanning and transmission electron microscopy. The results show that the Pt nanoparticles with 3–10 nm in diameter are well dispersed on the surface of active carbon. The electrocatalytic and analytical ability of Pt nanoparticles supported on active carbon modified electrode (Pt/C/GCE) was studied using cyclic voltammetry (CV) and chronoamperommetry. The Pt/C/GCE exhibits strong electrocatalytic activity to the glucose oxidation. Under optimal conditions, the Pt/C/GCE performed a current response towards glucose oxidation at a broad concentration range from 0.05 to 11.95 mM. Two linear regions could be observed at 0.05 to 3.5 mM with a sensitivity of 1.29 μA mM–1 cm–2 and at 3.5 to 11.95 mM with a sensitivity of 0.85 μA mM–1 cm–2, respectively. The Pt/C/GCE exhibits sufficient sensitivity and abilities of anti-interference.  相似文献   

14.
《Electroanalysis》2018,30(8):1811-1819
Novel copper‐palladium nanoparticles modified glassy carbon electrodes (Cu−Pd/GC) with enhanced nonenzymatic sensing for glucose were facilely prepared by one‐step electrodeposition. The structure and composition of the prepared nanoparticles were characterized by XRD, SEM, TEM and EDS, respectively. The electrode modified process was characterized by electrochemical impedance spectroscopy. Cyclic voltammetry and chronoamperometric experiments were used to evaluate the electrocatalytic activities of the electrodes toward glucose. The surface morphology and the electrocatalytic activities of Cu−Pd/GC was compared to Pd and Cu nanoparticles modified glassy carbon electrodes (Pd/GC and Cu/GC), respectively. Thanks to homogeneous distribution of Cu−Pd nanoparticles and the synergistic effect of Cu and Pd atoms, Cu−Pd/GC exhibited the highest sensitivity (298 μA mM−1 cm−2) and the widest linear amperometric response (0.01 mM to 9.6 mM, R2=0.996) toward glucose compared to Pd/GC and Cu/GC. The detection limit of Cu−Pd/GC was 0.32 μM (S/N=3). In addition, the as‐prepared Cu−Pd/GC glucose sensor also exhibited exceptional capabilities of anti‐interference, reproducibility and long‐term stability. The as‐prepared sensor was also evaluated for determination of glucose concentration in human blood serum samples, which exhibited high reliability and accuracy, having great potential in clinical application.  相似文献   

15.
The present study describes the fabrication of a sensitive amperometric sensor for the determination of persulfate. The immobilization surface was prepared by modifying a glassy carbon (GC) electrode with a nanocomposite containing ruthenium oxide (RuOx) nanoparticles and thionine (TH) or celestin blue (CB). The modified electrodes indicated excellent electrocatalytic activity toward persulfate reduction at a potential of +0.1 V. The proposed sensor showed detection limits of 1.46 µM for the GC/RuOx/TH modified electrode and 2.64 µM for the GC/RuOx/CB modified electrode. The sensitivities were obtained as 3 nA µM?1 at a concentration range of 10 µM to 11 mM for the GC/RuOx/TH modified electrode and 1 nA µM?1 at a concentration range of 10 µM to 6 mM for the GC/RuOx/CB modified electrodes.  相似文献   

16.
A cobalt oxide nanocluster/overoxidized polypyrrole composite film electrochemical sensing interface was fabricated by two step electrochemical method. The electrochemical properties and electrocatalytic activity of the resulting modified electrode were also studied carefully. The results showed that this modified electrode exhibited good stability, good anti‐interference ability, as well as high electrocatalytic activity to the oxidation of glucose. The linear range for the amperometric determination of glucose was 2.0×10?7–2.4×10?4 mol L?1 and 2.4×10?4–1.4×10?3 mol L?1 with a detection limit of 5.0×10?8 mol L?1 (S/N=3), respectively. The sensitivity was 1024 µA mM?1 cm?2.  相似文献   

17.
The present work describes a rapid and accurate amperometric technique for the determination of acetaminophen (ACT) in pharmaceutical preparations and human blood serum, based on electrocatalytic oxidation of ACT at a glassy carbon electrode modified by cadmium pentacyanonitrosylferrate (CdPCNF) film. The electrocatalytic response of the modified GC electrode was linear over the concentration of 1.64-52.90 μM. The limit of detection was found to be 2.04 μM by amperometric technique. The method was successfully utilized for the determination of ACT in various pharmaceutical preparations and the results have been statistically compared with those obtained by the official method. The interference of some pharmaceutical and biological compounds was investigated. The results of interference study showed that the Nafion-coated CdPCNF|GC electrode can be utilized as a selective amperometric sensor for acetaminophen determination in human blood serum. The mean value of rate constant k for catalytic reaction, and the diffusion coefficient of ACT (D) in the phosphate buffer solution of pH 7.2 were found to be 4.27 × 102 M?1 s?1, and (4.25 ± 0.33) × 10?6 cm2 s?1, respectively.  相似文献   

18.
Deposited cobalt microparticales (Co-MPs) film onto the platinum disk electrode has been successfully used as a new amperometric sensor for the determination of ascorbic acid (AA). AA is detected by surface catalyzed oxidation involving cobalt(III) oxyhydroxides in alkaline solution. The Co-MPs/Pt electrode exhibits a high electrocatalytic activity toward the AA oxidation. The diffusion coefficient of AA (6.09 × 105 cm2/s) and the catalytic rate constant (k cat = 6.27 × 103 M–1s–1) have been determined using electrochemical approaches. The amperometric response of the modified electrode is linear against the AA concentration in the range (0.01?0.48 mM). The sensor displays the best activity with a high response signal, a good sensitivity of 74.3 μA/mM, a low detection limit of 2.5 μM (signal/noise = 3) and a fast response time (<3 s). Moreover, the reproducibility, selectivity and applicability of this biosensor are satisfactorily evaluated.  相似文献   

19.
We report on a highly sensitive and selective nonenzymatic glucose sensor based on a glassy carbon electrode modified with a composite prepared from nickel(II) hydroxide nanoplates and carbon nanofibers. The nanocomposite was characterized by scanning electron microscopy and powder X-ray diffraction. Electrodes modified with pure Ni(OH)2 and with the nanocomposite were characterized by electrochemical impedance spectroscopy. Cyclic voltammetric and amperometric methods were used to investigate the catalytic properties of the modified electrodes for glucose electrooxidation in strongly alkaline solution. The sensor exhibits a wide linear range (from 0.001 to 1.2 mM), a low detection limit (0.76 μM), fast response time (< 5 s), high sensitivity (1038.6 μA?·?mM?1?·?cm?2), good reproducibility, and long operational stability. Application of the nonenzymatic sensor for monitoring glucose in real samples was also demonstrated.
Figure
We report on a highly sensitive and selective nonenzymatic glucose sensor based on a glassy carbon electrode modified with a nanocomposite prepared from nickel (II) hydroxide nanoplates and carbon nanofibers. The facile preparation, high electrocatalytic activity, relatively fast response, favorable reproducibility and long-term performance stability demonstrate the potential applications of the sensor.  相似文献   

20.
A novel glucose biosensor was developed based on the immobilization of glucose oxidase (GOx) on reduced graphene oxide incorporated with electrochemically deposited platinum and palladium nanoparticles (PtPdNPs). Reduced graphene oxide (RGO) was more hybridized by chemical and heat treatment. Bimetallic nanoparticles were deposited electrochemically on the RGO surface for potential application of the Pd? Pt alloy in biosensor preparation. The as‐prepared hybrid electrode exhibited high electrocatalytic activities toward H2O2, with a wide linear response range from 0.5 to 8 mM (R2=0.997) and high sensitivity of 814×10?6 A/mMcm2. Furthermore, glucose oxidase with active material was integrated by a simple casting method on the RGO/PdPtNPs surface. The as‐prepared biosensor showed good amperometric response to glucose in the linear range from 2 mM to 12 mM, with a sensitivity of 24×10?6 A/mMcm2, a low detection limit of 0.001 mM, and a short response time (5 s). Moreover, the effect of interference materials, reproducibility and the stability of the sensor were also investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号