1.
《Electroanalysis》2006,18(9):918-927
Uric acid (UA) sensor based on molecularly imprinted polymer‐modified hanging mercury drop electrode was developed for sensitive and selective analysis in aqueous and blood serum samples. The uric acid‐imprinted polymer was prepared from melamine and chloranil and coated directly onto the surface of a hanging mercury drop electrode, under charge‐transfer interactions at +0.4 V (vs. Ag/AgCl), in model 303A electrode system connected with a polarographic analyzer/stripping voltammeter (PAR model 264A). The binding event of uric acid was detected in the imprinted polymer layer through differential pulse, cathodic stripping voltammetry (DPCSV) at optimized operational conditions [accumulation potential +0.4 V (vs. Ag/AgCl), accumulation time 120 s, pH 7.0, scan rate 10 mV s?1, pulse amplitude 25 mV]. The limit of detection for UA was found to be 0.024 μg mL?1 (RSD=0.64%, S/N=3). Under the optimized operational conditions, the sensor was able to differentiate between uric acid and other closely structural‐related compounds and interfering substances. Ascorbic acid (AA), a major interferent in UA estimation, was not adsorbed on the surface of sensor electrode. The present sensor is, therefore, UA‐selective at all concentrations of AA present in human blood serum samples. The précised and accurate quantification of UA have been made in the dilute as well as concentrated regions varying within limits 0.1–4.0 and 9.8–137.0 μg mL?1, respectively.  相似文献   

2.
An electrochemical sensor based on electropolymerizing o‐phenylenediamine (o‐PD) on a glassy carbon electrode (GCE) was developed for determination of reducing sugars. The molecular imprinted sensor was tested by differential pulse voltammetry (DPV) to verify the changes in peak currents of hexacyanoferrate. Under the optimum analytical conditions, the current change was linear to the logarithm of glucose and fructose concentration from 0.25 to 25 µM. The detection limit of glucose and fructose were 0.185 µM and 0.173 µM, respectively. Besides, the applicability of the sensitive sensor has been successfully evaluated by determining reducing sugars in the samples from sugarcane industries.  相似文献   

3.
Taher Alizadeh 《Electroanalysis》2009,21(13):1490-1498
The design and construction of an extra high selective voltammetric sensor for parathion by using a molecularly imprinted polymer (MIP) as recognition element was introduced. A parathion selective MIP and a nonimprinted polymer (NIP) were synthesized and then incorporated in the carbon paste electrode. The MIP‐CP electrode showed very high recognition ability in comparison to NIP‐CP. It was shown that electrode washing after parathion extraction, led to enhanced selectivity. Some parameters affecting the sensor response were optimized and then the calibration curve was plotted. A dynamic linear range of 1.7–900 nM was obtained. The detection limit of the sensor was calculated as 0.5 nM. This sensor was used successfully for parathion determination in real samples such as ground water and vegetables.  相似文献   

4.
Lakshmi D  Prasad BB  Sharma PS 《Talanta》2006,70(2):272-280
Molecularly imprinted polymers (MIP) have been elucidated to work as artificial receptors. In our present study, a MIP was applied as a molecular recognition element to a chemical sensor. We have constructed a creatinine sensor based on a MIP layer selective for creatinine and its differential pulse, cathodic stripping voltammetric detection (DPCSV) on a hanging mercury drop electrode (HMDE). The creatinine sensor was fabricated by the drop coating of dimethylformamide (DMF) solution of a creatinine-imprinted polymer onto the surface of HMDE. The modified-HMDE, preanodised in neutral medium at +0.4 V versus Ag/AgCl for 120 s, exhibited a marked enhancement in DPCSV current in comparison to the less anodised (≤+0.3 V) HMDE. The creatinine was preconcentrated and instantaneously oxidised in MIP layer giving DPCSV response in the concentration range of 0.0025-84.0 μg mL−1 [detection limit (3σ) 1.49 ng mL−1]. The sensor was found to be highly selective for creatinine without any response of interferents viz., NaCl, urea, creatine, glucose, phenylalanine, tyrosine, histidine and cytosine. The non-imprinted polymer-modified electrode did not show linear response to creatinine. The imprinting factor as high as 9.4 implies that the imprinted polymer exclusively acts as a recognition element of creatinine sensor. The proposed procedure can be used to determine creatinine in human blood serum without any preliminary treatment of the sample in an accurate, rapid and simple way.  相似文献   

5.
A voltammetric sensor for sensitive and specific determination of trans‐resveratrol (RES) were prepared based on immobilization of an RES‐imprinted film on the surface of functionalized Indium Tin Oxide (ITO) electrode, which was modified with γ‐methacyloxypropyl trimethoxysilane (γ‐MPS). Cyclic Voltammetry (CV) was presented to extract RES from the molecularly imprinted polymer film and RES were extracted rapidly and completely. The binding performance of the imprinted electrode with the template RES were investigated using differential pulse voltammetry (DPV). The results showed that the imprinted ITO film can give selective recognition to the template RES over that of structurally analogous molecules. A linear response to RES in the concentration range of 2.0×10?6 M to 2.0×10?5 M was observed with a correlation coefficient of 0.992, and the detection limit of the electrochemical sensor was 8.0×10?7 M. Whereas, binding to the reference nonimprinted electrode, made in the same way but without the addition of template RES, there was almost no response to RES.  相似文献   

6.
利用分子印迹技术,以马来松香丙烯酸乙二醇酯为交联剂,使用自由基热聚合法在石墨烯修饰的玻碳电极表面合成毒死蜱( CPF)分子印迹聚合膜,制得了CPF分子印迹电化学传感器。采用循环伏安法、线性扫描伏安法和电化学交流阻抗法等,考察了此CPF分子印迹膜的电化学性能。在最佳检测条件下,传感器的峰电流与CPF浓度在2.0×10-7~1.0×10-5mol/L范围内呈线性关系,线性方程为Ip(μA)=-7.1834-0.2424C (μmol/L),相关系数r2=0.9959,检出限为6.7×10-8 mol/L(S/N=3)。构建了CPF分子印迹电化学传感器的动力学吸附模型,测得印迹传感器的印迹因子β=2.59,结合速率常数k=12.2324 s。传感器表现出良好的重现性和稳定性,并成功用于实际水样和蔬菜样品中CPF的测定,加标回收率为94.1%~101.4%。  相似文献   

7.
《Electroanalysis》2004,16(7):547-555
ABTS, 2,2′‐azinobis(3‐ethylbenzothiazoline‐6‐sulfonate), a colorless dianion that forms a colored radical upon oxidation, was characterized with electrochemistry and spectroscopy and demonstrated to be a detectable analyte in a polymer‐modified spectroelectrochemical sensor. Three positively charged polymers were incorporated into a thin film on an indium tin oxide (ITO) optically transparent electrode and used to concentrate ABTS at the electrode surface. Of the three films, poly(vinylbenzyl trimethyl ammonium chloride)‐poly(vinyl alcohol) (PVTAC‐PVA), poly(diallyldimethylammonium chloride)‐silica (PDMDAAC‐SiO2), and quaternized poly(4‐vinyl‐N‐methylpyridinium nitrate)‐silica (QPVP‐SiO2), PVTAC‐PVA demonstrated the best ability to absorb ABTS. Within 20 min, a change of 0.2 absorbance units at 417 nm and 13.6 μA/cm2 in anodic peak current density in cyclic voltammetry at a scan rate of 0.025 V/s were observed.  相似文献   

8.
基于Au-Pd合金修饰的玻碳电极为工作电极,采用循环伏安法将邻氨基酚与尼古丁电沉积在工作电极上,制备了尼古丁分子印迹膜传感器。采用差分脉冲伏安法研究尼古丁在尼古丁分子印迹膜传感器上的电化学行为,考察了模板溶解时间、富集时间和溶液pH值对尼古丁测定的影响。在优化实验条件下,尼古丁分子印迹膜传感器的线性范围为1.2×10~(-7)~2.5×10~(-3) mol/L,检出限为4.6×10~(-8) mol/L。用该传感器对吸烟者血液中尼古丁的含量进行检测,结果表明,该传感器具有灵敏度高、线性范围宽、重现性及稳定性好等优点。  相似文献   

9.
《Analytical letters》2012,45(6):996-1014
A novel electrochemical sensor for bisphenol A was developed through the combination of a molecular imprinting technique with a multiwalled carbon nanotube paste electrode. A molecularly imprinted polymer and nonimprinted polymer were synthesized in the presence and absence of bisphenol A, and then used to prepare the electrode. The bisphenol A imprinted polymer was applied as a selective recognition element in the electrochemical sensor. Differential pulse voltammetry was used to characterize the electrochemical behavior of bisphenol A at the modified electrodes. The results showed that the imprinted sensor had highest response for bisphenol A. Parameters including the carbon paste composition, pH, and adsorption time for the imprinted sensor were optimized. Under the optimized conditions, the differential pulse voltammetry peak current was linear with the concentration of bisphenol A from 0.08 to 100.0 µM, with a detection limit of 0.022 µM. The imprinted sensor for bisphenol A exhibited good selectivity, stability, and reproducibility. This sensor was successfully used for the determination of bisphenol A in real water samples.  相似文献   

10.
11.
碳纳米管修饰电极分子印迹传感器快速测定沙丁胺醇   总被引:1,自引:0,他引:1  
齐玉冰  刘瑛  宋启军 《分析化学》2011,39(7):1053-1057
以单壁碳纳米管(SWNTs)为电极材料,应用分子印迹技术,以邻苯二胺为功能单体、沙丁胺醇为模板,采用电化学聚合法制备了一种新型的快速检测沙丁胺醇分子印迹传感器,并运用电化学方法去除模板.在磷酸盐缓冲溶液(PBS)中,利用线性溶出伏安法对印迹和非印迹膜的性能进行了比较,对分子印迹膜的影响因素进行了优化.实验表明,本传感器...  相似文献   

12.
分子印迹电位型传感器快速检测猪尿液中的克伦特罗   总被引:2,自引:0,他引:2  
梁荣宁  高奇  秦伟 《分析化学》2012,(3):354-358
以盐酸克伦特罗为模板分子,采用沉淀聚合法合成了克伦特罗的分子印迹聚合物,并以其为离子载体,制得分子印迹聚合物膜克伦特罗离子选择性电极。在最优实验条件下,电极对克伦特罗阳离子的检出限可达7.0×10-8mol/L,线性范围为1.0×10-7~1.0×10-4mol/L,能斯特斜率为55.7 mV/decade。此电极具有优越的选择性、快速的响应时间以及良好的稳定性;已成功应用于实际猪尿样品中克伦特罗的测定,加标回收率为98%~107%,检测时间小于3 min。  相似文献   

13.
《Electroanalysis》2003,15(12):1031-1037
A cholesterol biosensors fabricated by immobilization of cholesterol oxidase (ChOx) in a layer of silicic sol‐gel matrix on the top of a Prussian Blue‐modified glassy carbon electrode was prepared. It is based on the detection of hydrogen peroxide produced by ChOx at ?0.05 V. The half‐lifetime of the biosensor is about 35 days. Cholesterol can be determined in the concentration range of 1×10?6?8×10?5 mol/L with a detection limit of 1.2×10?7 mol/L. Normal interfering compounds, such as ascorbic acid and uric acid do not affect the determination. The high sensitivity and outstanding selectivity are attributed to the Prussian Blue film modified on the sensor.  相似文献   

14.
A highly selective molecularly imprinted polymer electrochemical sensor for In3+ detection was proposed. In3+ ion was chelated with alizarin red S to form a complex In‐ARS. The complex was used as the template molecule to prepare a molecularly imprinted polymer (MIP) based sensor. The selectivity of the sensor was improved significantly due to the three‐dimensional specific structure of the complex, and the selective complexation of ligands for metal ions. Moreover, the sensitivity of the proposed sensor was improved by recording the reductive current of ligand in complex. This technique was highly sensitive for quantitative analysis of In3+ in the concentrations ranged from 1×10?8 mol/L to 2.5×10?7 mol/L with a detection limit of 4.7×10?9 mol/L. The proposed sensor has been successfully used in detecting In3+ in real samples.  相似文献   

15.
Measuring the serum bilirubin (BR) level is part of the common test for newborns, since high concentrations of bilirubin in the blood can cause brain damage and even death for them. Therefore, achieving a fast, accurate and cost effective method for bilirubin assay in medical diagnosis and Medical management of patients with jaundice, especially neonates, is very important. In this study, an electrochemical sensor was developed to detect low amounts of bilirubin in serum samples. The basis of the work is the BR imprinted polymer synthesis and the use of this polymer as a recognition element in the production of the bilirubin voltammetric sensor. For this purpose, bilirubin imprinted polymer was synthesized using the simple sol gel method and the prepared polymer is characterized by SEM and FT‐IR. In the next step, this polymer was applied to modify the carbon paste electrode and provide a sensitive and selective sensor for the BR molecule. The proposed sensor was able to measure the bilirubin in the concentration range of 1 to 100 μM after optimizing the operating conditions. The limit of detection (LOD) and limit of quantification (LOQ) was calculated 0.75 μM and 2.5 μM respectively. It is also applicable to bilirubin assay in serum samples.  相似文献   

16.
采用自组装以及电聚合的方法,在磷酸盐缓冲液(PBS)中以3,4-乙烯二氧噻吩(EDOT)为功能单体,盐酸阿霉素(DOX)为模板,在金电极表面电聚合制备DOX印迹敏感膜(MIPs),构建了一种选择性检测DOX的分子印迹电化学传感器.采用循环伏安法(CV)及交流阻抗法(EIS)对其性能进行了表征.优化实验条件后,在含0.005 mol/L K3[Fe(CN)_6]及0.1 mol/L KCl的PBS中,应用差分脉冲伏安法(DPV)测试了该传感器的响应性能.实验结果表明,该传感器检测DOX的线性范围为4.0×10~(-7)~1.0×10~(-6)mol/L,相关系数为0.9967,检出限(S/N=3)达6.5×10~(-8)mol/L;采用电化学洗脱法可使传感器再生,对DOX的测定具有良好重现性及稳定性;该传感器对于干扰物长春碱、放线菌素D及5-氟尿嘧啶有微弱的电流响应,显示出良好的选择性.将该传感器用于人体血样中盐酸阿霉素的分析,回收率为96.0%~106.7%,表明其具有潜在的实用价值.  相似文献   

17.
Molecularly imprinted polymers(MIPs) were applied as molecular recognition elements to an electrochemical sensor for cinchonidine(CD). A kind of MIP was synthesized with cinchonidine as template, modified rosin( ethylene glycol maleic rosinate acrylate) containing the skeleton of phenanthrene rings as cross-linker and methylacrylic acid as functional monomer. MIP membrane was prepared on a glassy carbon electrode for the determination of CD via free radical polymerization method. Electrochemical impedance spectroscopy(EIS) and cyclic voltammetry( CV) were used to characterize the membrane electrochemical behavior in electrode fabrication process. The experimental conditions were discussed. Under optimum conditions, it was found that the response of peak currents was linear to the concentration of CD in a range of 0.013―2.26 mmol/L. The detection limit for CD is 1 μmol/L, the relative standard deviation for 100 μmol/L CD is 1.34% and the incubation time is 2 min. The sensor was applied to the determination of CD in urine samples with satisfactory results.  相似文献   

18.
The mycotoxin zearalenone (ZEA) prompts reproductive toxicity due to its strong estrogenic effects. In this work, an electrochemical sensor for determination of ZEA was developed by electropolymerization of a molecularly imprinted poly (o‐phenylenediamine) (PPD) film on screen‐printed gold electrode (SPGE) surface. The sensor was examined by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using K3[Fe(CN)6]/K4[Fe(CN)6] as redox probe. The molecularly imprinted polymer (MIP) sensor showed a wide determination range from 2.50 to 200.00 ngmL?1 for ZEA. The Limit of detection (LOD) was calculated to be 0.20 ngmL?1, based on the signal to noise (S/N) ratio equal to 3.0. The sensor displayed good repeatability, with RSD values≤4.6 %, and maintained 93.2 % of its initial response after storage for 10 days in air at room temperature. The developed method was successfully applied for the determination of ZEA in corn flakes with mean recoveries ranged from 96.2 % to 103.8 % and RSDs within the interval of 2.1 % to 3.8 %.  相似文献   

19.
In the present work, an electrochemical sensor was developed for simple and sensitive determination of tryptophan (Trp) using multi‐walled carbon nanotubes modified sol‐gel electrode (MWCNTs/SGE). The electrocatalytic oxidation of tryptophan was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that the oxidation peak current of Trp at the MWCNTs/SGE was greatly improved compared with that of the bare SGE. Furthermore, at the MWCNTs/SGE, the anodic peak potential of Trp is shifted about 220 mV to more negative value indicated that modified electrode has better electrocatalytic activity for electro‐oxidation of Trp. The anodic peak currents increased linearly with the concentration of tryptophan in the range of 0.2 × 10?6 to 15 × 10?6 M with a detection limit of 0.139 × 10?6 M (at an S/N = 3).  相似文献   

20.
A DNA probe that was based on methylene blue (MB) imprinted polyvinyl pyridine polymer (MIP) modified carbon paste electrodes were developed for the first time for electrochemical monitoring of DNA. Probes were built up by adsorbing MB onto modified electrodes prior to DNA immobilization. It was shown that DNA strongly immobilizes on MIP modified electrodes when MB was adsorbed in advance of DNA immobilization. The performance of the MB imprinted polymer modified carbon paste electrodes (MIP‐CPE) to rebind the template molecule (MB) were compared to those of control polymer modified (non‐imprinted polymer NIP‐CPE) and bare (CPE) electrodes. Electrochemical signal resulting from the oxidation of guanine moiety of the immobilized probe DNA was high enough on the constructed platform, implicating that probes of this kind could be favorably used for DNA analysis. These probes exhibited high selectivity for its complementary DNA sequences (target). HBV‐DNA hybridization was studied to evaluate the selectivity of the probes for complementary, non‐complementary and mismatch sequences. The detection limit of the probe for the target DNA was 8.72 µg/mL (1.38 µM), which was better than those attained by some earlier DNA sensor studies.  相似文献   