首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(9):1698-1713
Abstract

This work reports the development of a biosensor method for the label‐free detection of specific DNA sequences. In the initial phase, square wave voltammetry (SWV) was used in a comparative investigation into the electrochemical oxidation of purines (guanine and adenine) and DNA fragments at various electrode surfaces: carbon paste (CPE), glassy carbon electrode (GCE), and gold (AuE). Relative to the carbon electrodes, an approximate 4.0‐fold, 6.0‐fold, and 3.25‐fold increase in the anodic response was observed when guanine, adenine, and hydrolyzed DNA, respectively, were measured on the AuE. It was shown that the guanine and adenine bases could be successfully determined by use of SWV for a deoxyribonucleic acid sample following acid hydrolysis. This label‐free detection of hydrolyzed DNA on gold electrodes has significant advantages over methods using existing carbon electrode materials because of its higher sensitivity and the potential applicability of microfabrication techniques for the production of the requisite gold electrodes.

In another phase of development, the times and conditions for DNA hydrolysis and purine release were investigated. It was shown that under optimal conditions, trace levels of the purine bases could be readily detected following 20 min of hydrolysis at room temperature. The proposed method can be used to estimate the guanine and adenine contents in DNA with in a linear range of 5–30 ng ml?1.

Finally, when appropriate probe sequences were first adsorbed on the surface of the screen‐printed gold electrode (SPGE), this electrochemical biosensor could be used to specifically detect sequences from ss corona virus aviair following hybridization and hydrolysis reactions on the sensor surface. No enhancement of the voltammetric response was observed when the sensor was challenged with a non‐complementary DNA sequence.  相似文献   

2.
A room temperature ionic liquid N‐butylpyridinium hexafluorophosphate (BPPF6) was used as a binder to make an ionic liquid modified carbon paste electrode (IL‐CPE), which showed good characteristics such as simple preparation procedure, fast electrochemical response and good conductivity. The electrochemical oxidation of ascorbic acid (AA) on the new IL‐CPE was carefully studied. The oxidation peak potential of AA on the IL‐CPE appeared at 109 mV (vs. SCE), which was about 338 mV decrease of the overpotential compared to that obtained on the traditional carbon paste electrode (CPE) and the oxidation peak current was increased for about four times. The electrochemical parameters of AA on the IL‐CPE were calculated with the charge transfer coefficient (α) and the electrode reaction rate constant (ks) as 0.87 and 0.800 s?1, respectively. Based on the relationship of the oxidation peak current and the concentration of AA a sensitive analytical method was established with cyclic voltammetry. The linear range for AA determination was in the range from 1.0×10?5 to 3.0×10?3 mol/L with the linear regression equation as Ip (μA)=?2.52–0.064C (μmol/L) (n=13, γ=0.9942) and the detection limit was calculated as 8.0×10?6 mol/L (3σ). The proposed method was free of the interferences of coexisting substances such as dopamine (DA) and amino acids etc., and successfully applied to the vitamin C tablets determination.  相似文献   

3.
In this paper a molecular wire modified carbon paste electrode (MW‐CPE) was firstly prepared by mixing graphite powder with diphenylacetylene (DPA). Then a graphene (GR) and chitosan (CTS) composite film was further modified on the surface of MW‐CPE to receive the graphene functionalized electrode (CTS‐GR/MW‐CPE), which was used for the sensitive electrochemical detection of adenosine‐5′‐triphosphate (ATP). The CTS‐GR/MW‐CPE exhibited excellent electrochemical performance and the electrochemical behavior of ATP on the CTS‐GR/MW‐CPE was carefully studied by cyclic voltammetry with an irreversible oxidation peak appearing at 1.369 V (vs. SCE). The electrochemical parameters such as charge transfer coefficient (α) and electrode reaction standard rate constant (ks) were calculated with the results of 0.53 and 5.28×10?6 s?1, respectively. By using differential pulse voltammetry (DPV) as detection technique, the oxidation peak current showed good linear relationship with ATP concentration in the range from 1.0 nM to 700.0 µM with a detection limit of 0.342 nM (3σ). The common coexisting substances, such as uric acid, ascorbic acid and guanosine‐5′‐triphosphate (GTP), showed no interferences and the modified electrode was successfully applied to injection sample detection.  相似文献   

4.
The electrochemical behavior of oxadiargyl at a graphene‐paste electrode modified with an azo dye, 2‐(4‐((4‐acetylphenyl)diazenyl)phenylamino)ethanol (ADPE), ADPE/MGRPE was investigated. The modified electrode showed high electrocatalytic activity toward oxadiargyl. The apparent electron transfer rate constant (ks) and charge transfer coefficient (α) between electrode and ADPE were 1.16 s?1 and 0.41, respectively. The differential pulse voltammetry response of the modified graphene‐paste electrode was linear against the concentration of oxadiargyl in the range from 0.03 to 1.4 mg L?1. The limit of detection was found to be 1.3 µg L?1 (S/N=3). The practical analytical utility of this electrode was demonstrated by measurement of oxadiargyl in river water, soil and rice samples.  相似文献   

5.
《Electroanalysis》2005,17(19):1740-1745
A p‐chloranil modified carbon paste electrode was constructed and the electrochemical behavior of this electrode was studied in the aqueous solution with different pH. From the E1/2–pH diagram for this compound the values of formal potential E0' and pKa of some different redox and acid‐base couples depending on the solution pH were estimated. The diffusion coefficient, D, value for p‐chloranil was estimated 1.5×10?7 cm2 s?1. It has been shown by direct current cyclic voltammetry and double potential step chronoamperometry, that this p‐chloranil incorporated carbon paste electrode, can catalyze the oxidation of ascorbic acid in the aqueous buffered solution. Under the optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 325 mV less positive than that at an unmodified carbon past electrode. The catalytic oxidation peak currents was linearly dependent on the ascorbic acid concentration and a linear calibration curve was obtained in the range of 7×10?5 M–4×10?3 M of ascorbic acid with a correlation coefficient of 0.9998. The limit of detection (3σ) was determined as 3.5×10 ?5 M. This method was used as simple, selective and precise voltammetric method for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

6.
A new selective carbon paste electrode (CPE), was applied as an electrochemical sensor for the detection of norepinephrine (NOE). The sensor was modified with 6‐amino‐4‐(3,4‐dihydroxyphenyl)‐3‐methyl‐1,4‐dihydropyrano[2,3‐c],pyrazole‐5‐carbonitrile (ADPC) assisted Fe2O3@CeO2 coreshell nanoparticles (CNs) synthesized by simple method. To identify the redox properties of the modified electrode, and to examine its electrochemical properties, cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV) were conducted. Through electrochemical investigations, the coefficient of electron transfer between ADPC and the CNs/CPE (i. e. carbon paste electrode which was modified with CNs), the apparent charge transfer rate constant (ks), and the diffusion coefficient (D) were calculated. The NOE oxidation occurred at the optimum pH of 7.0 and a potential that was about 235 mV less positive than that of the unmodified carbon paste electrode. The interaction between the two metals in the Fe2O3@CeO2 coreshell led to an increase in the surface area and, consequently a sharp increase in the current. The differential pulse voltammogram of NOE showed two linear dynamic ranges an excellent detection limit (3σ) of 40 nM. In addition, NOE, AC and Trp were simultaneously determined at the modified electrode. Finally, NOE was quantitated in a number of real samples.  相似文献   

7.
A novel carbon paste electrode modified with carbon nanotubes and 5‐amino‐2′‐ethyl‐biphenyl‐2‐ol (5AEB) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for electrocatalytic oxidation of levodopa (LD) and carbidopa (CD), is described. Cyclic voltammetry (CV) was used to investigate the redox properties of this modified electrode at various scan rates. The apparent charge transfer rate constant, ks, and transfer coefficient, a, for electron transfer between 5AEB and CPE were calculated as 17.3 s?1 and 0.5, respectively. Square wave voltammetry (SWV) exhibits a linear dynamic range from 2.5×10?7 to 2.0×10?4 M and a detection limit of 9.0×10?8 M for LD.  相似文献   

8.
Herein, a sodium montmorillonite-modified carbon paste electrode is described for the electrochemical determination of guanine. Guanine yields a well-defined and very sensitive oxidation peak at the sodium montmorillonite-modified carbon paste electrode. Compared with the unmodified carbon paste electrode, the modified electrode facilitates the electron transfer of guanine, since it notably increases the oxidation peak current and lowers the oxidation overpotential of guanine. Based on this, a simple sensitive reliable electrochemical method is proposed for the detection of guanine after all the experimental parameters, such as solution pH value, sodium montmorillonite content in the carbon paste electrode, accumulation potential, and time, are optimized. Under the optimized conditions, the oxidation peak current of guanine varies linearly with its concentration in the range 5.0×10−8 to 2.0×10−5 M and the detection limit (signal-to-noise=3) is 2.0×10−8 M after 4-min accumulation. This method is successfully demonstrated with urine samples. Published in Russian in Elektrokhimiya, 2006, Vol. 42, No. 2, pp. 178–182. The text was submitted by the authors in English.  相似文献   

9.
We studied the reactivity of peroxynitrite and different nucleic acid molecules using DNA electrochemical biosensors. SIN‐1 (3‐morpholinosydnonimine) has been used for the simultaneous generation of NO?and superoxide, i.e., as a peroxynitrite (ONOO?) donor. Double strand DNA (dsDNA), single strand DNA (ssDNA) and 15 guanine bases oligonucleotide (Oligo(dG)15) were immobilized on a carbon paste electrode to generate the biosensor and DPV was selected as the electroanalytical technique. Results showed that electrochemical biosensors were very sensitive for detecting interaction between ONOO? and DNA. A down/up effect was observed, i.e., at low ONOO? concentrations the guanine oxidation signal decreased while at high ONOO? concentrations the guanine oxidation current increased. Oligo(dG)15 exhibited greater interaction at low ONOO? concentrations than the other DNA molecules. The reactivity between ONOO? and DNA was also evaluated in solution phase, showing the same down/up effect. Finally, the capacity of DNA to hybridize was prevented after interaction with ONOO?.  相似文献   

10.
An ionic liquid N‐hexylpyridinium hexafluorophosphate (HPPF6) modified carbon paste electrode was fabricated for the sensitive voltammetric determination of adenosine in this paper. Carbon ionic liquid electrode (CILE) was prepared by mixing graphite powder and HPPF6 together and the CILE was characterized by scanning electron microscopy (SEM) and electrochemical methods. The electrochemical behaviors of adenosine on the CILE were studied carefully. Compared with the traditional carbon paste electrode (CPE), a small negative shift of the oxidation peak potential appeared with greatly increase of the oxidation peak current, which indicated the presence of ionic liquid in the carbon paste not only as the binder but also as the modifier and promoter. Under the optimal conditions the oxidation peak current increased with the adenosine concentration in the range from 1.0×10?6 mol/L to 1.4×10?4 mol/L with the detection limit of 9.1×10?7 mol/L (S/N=3) by differential pulse voltammetry. The proposed method was applied to the human urine samples detection with satisfactory results.  相似文献   

11.
In this paper, nano‐gold modified carbon paste electrode (NGMCPE) was employed to develop an electrochemical DNA hybridization biosensor. The proposed sensor was made up by immobilization of 15‐mer single stranded oligonucleotide probe for detection of target DNA. Hybridization detection relies on the alternation in guanine oxidation signal following hybridization of the probe with complementary genomic DNA. The guanine oxidation was monitored using differential pulse voltammetry (DPV). Different factors such as activation potential, activation time and probe immobilization conditions were optimized. The selectivity of the sensor was investigated by non‐complementary oligonucleotides. Diagnostic performance of the biosensor was described and the detection limit was found 1.9 × 10?13 M at the NGMCPE surface. All of the investigations were performed in both CPE and NGMCPE and finally their results were compared.  相似文献   

12.
A new electrochemical method was proposed for the determination of adenosine‐5′‐triphosphate (ATP) based on the electrooxidation at a molecular wire (MW) modified carbon paste electrode (CPE), which was fabricated with diphenylacetylene (DPA) as the binder. A single well‐defined irreversible oxidation peak of ATP appeared on MW‐CPE with adsorption‐controlled process and enhanced electrochemical response in a pH 3.0 Britton‐Robinson buffer solution, which was due to the presence of high conductive DPA in the electrode. The electrochemical parameters of ATP were calculated with the electron transfer coefficient (α) as 0.54, the electron transfer number (n) as 1.9, the apparent heterogeneous electron transfer rate constant (ks) as 2.67 × 10?5 s?1 and the surface coverage (ΓT) as 4.15 × 10?10 mol cm?2. Under the selected conditions the oxidation peak current was proportional to ATP concentration in the range from 1.0 × 10?7 mol L?1 to 2.0 × 10?3 mol L?1 with the detection limit as 1.28 × 10?8 mol L?1 (3σ) by sensitive differential pulse voltammetry. The proposed method showed good selectivity without the interferences of coexisting substances and was successful applied to the ATP injection samples detection.  相似文献   

13.
A new hemoglobin (Hb) and room temperature ionic liquid modified carbon paste electrode was constructed by mixing Hb with 1‐butyl‐3‐methylimidazolium hexafluorophosphate (BMIMPF6) and graphite powder together. The Hb modified carbon ionic liquid electrode (Hb‐CILE) was further characterized by FT‐IR spectra, scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). Hb in the carbon ionic liquid electrode remained its natural structure and showed good direct electrochemical behaviors. A pair of well‐defined quasireversible redox peaks appeared with the apparent standard potential (E′) as ?0.334 (vs. SCE) in pH 7.0 phosphate buffer solution (PBS). The electrochemical parameters such as the electron transfer number (n), the electron transfer coefficient (α) and the heterogeneous electron transfer kinetic constant (ks) of the electrode reaction were calculated with the results as 1.2, 0.465 and 0.434 s?1, respectively. The fabricated Hb‐CILE exhibited excellent electrocatalytic activity to the reduction of H2O2. The calibration range for H2O2 quantitation was between 8.0×10?6 mol/L and 2.8×10?4 mol/L with the linear regression equation as Iss (μA)=0.12 C (μmol/L)+0.73 (n=18, γ=0.997) and the detection limit as 1.0×10?6 mol/L (3σ). The apparent Michaelis–Menten constant (KMapp) of Hb in the modified electrode was estimated to be 1.103 mmol/L. The surface of this electrochemical sensor can be renewed by a simple polishing step and showed good reproducibility.  相似文献   

14.
《中国化学会会志》2018,65(5):603-612
In this work, the electrochemical oxidation of methanol was investigated by different electrochemical methods at a carbon paste electrode (CPE) modified with (N‐5‐methoxysalicylaldehyde, N´‐2‐hydroxyacetophenon‐1, 2 phenylenediimino nickel(II) complex (Ni(II)–MHP) and reduced graphene oxide (RGO), which is named Ni(II)‐MHP/RGO/CPE, in an alkaline solution. This modified electrode was found to be efficient for the oxidation of methanol. It was found that methanol was oxidized by the NiOOH groups generated by further electrochemical oxidation of nickel(II) hydroxide on the surface of the modified electrode. Under optimum conditions, some parameters of the analyte (MeOH), such as the electron transfer coefficient (α), the electron transfer rate constant) ks), and the diffusion coefficient of species in a 0.1 M solution (pH = 13), were determined. The designed sensor showed a linear dynamic range of 2.0–100.0 and 100.0–1000.0 μM and a detection limit of 0.68 μM for MeOH determination. The Ni(II)‐MHP/RGO/CPE sensor was used in the determination of MeOH in a real sample.  相似文献   

15.
The electrochemical properties of hydrazine studied at the surface of a carbon paste electrode spiked with p‐bromanil (tetrabromo‐p‐benzoquinone) using cyclic voltammetry (CV), double potential‐step chronoamperometry and differential pulse voltammetry (DPV) in aqueous media. The results show this quinone derivative modified carbon paste electrode, can catalyze the hydrazine oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 10.00), the oxidation of hydrazine at the surface of this carbon paste modified electrode occurs at a potential of about 550 mV less positive than that of a bar carbon paste electrode. The electrocatalytic oxidation peak current of hydrazine showed a linear dependent on the hydrazine concentrations and linear analytical curves were obtained in the ranges of 6.00×10?5 M–8.00×10?3 M and 7.00×10?6 M–8.00×10?4 M of hydrazine concentration with CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 3.6×10?5 M and 5.2×10?6 M by CV and DPV methods. This method was also used for the determination of hydrazine in the real sample (waste water of the Mazandaran wood and paper factory) by standard addition method.  相似文献   

16.
The electrochemical behaviors of guanosine on the ionic liquid of N-butylpyridinium hexafluorophosphate (BPPF6) modified carbon paste electrode (CPE) was studied in this paper and further used for guanosine detection. Guanosine showed an adsorption irreversible oxidation process on the carbon ionic liquid electrode (CILE) with the oxidation peak potential located at 1.12 V (vs. SCE) in a pH 4.5 Britton-Robinson (B-R) buffer solution. Compared with that on the traditional carbon paste electrode, small shift of the oxidation peak potentials appeared but with a great increment of the oxidation peak current on the CILE, which was due to the presence of ionic liquid in the modified electrode adsorbed the guanosine on the surface and promoted the electrochemical response. The electrochemical parameters such as the electron transfer coefficient (α), the electron transfer number (n), and the electrode reaction standard rate constant (ks) were calculated as 0.74, 1.9 and 1.26 × 10−4 s−1, respectively. Under the optimal conditions the oxidation peak current showed a good linear relationship with the guanosine concentration in the range from 1.0 × 10−6 to 1.0 × 10−4 mol/L by cyclic voltammetry with the detection limit of 2.61 × 10−7 mol/L (3σ). The common coexisting substances showed no interferences to the guanosine oxidation. The CILE showed good ability to distinguish the electrochemical response of guanosine and guanine in the mixture solution. The urine samples were further detected by the proposed method with satisfactory results.  相似文献   

17.
An electrochemical dsDNA nanobiosensor was fabricated using amino‐functionalized multi walled carbon nanotubes modified glassy carbon electrode (NH2fMWCNTs/GCE) for the sensitive detection of DNA bases and electrochemical monitoring of drug‐DNA interaction. The influence of functional groups on MWCNT was studied by MWCNT functionalized with NH2 (NH2fMWCNTs) and COOH (COOHfMWCNT) groups based on the signal of DNA bases. The modified electrodes were characterized by scanning electron microscopy. One layer of calf thymus double stranded deoxyribonucleic acid (ct‐dsDNA) was immobilized onto the NH2fMWCNTs/GCE (dsDNA/NH2fMWCNTs/GCE). The dsDNA/NH2fMWCNTs/GCE were used to investigate the interaction between the dsDNA and the anticancer drug gemcitabine by differential pulse voltammetry in acetate buffer of pH 4.70. For the confirmation of interaction, the lowering in intensity of the current signals of guanine and adenine was considered as an indicator. Electrochemical impedance spectroscopy studies were performed for the comparison of the modified surfaces. In order to define and visualize the interaction mechanism between gemcitabine and dsDNA/NH2fMWCNTs/GCE at the molecular level, in silico methods including docking and molecular dynamics simulations were employed.  相似文献   

18.
5‐amino‐1,10‐phenanthroline‐Fe(II) complex is immobilized onto GC electrode and used for determination of DNA bases. Modifications are traced by electrochemical methods. All DNA bases are electroactive on the modified electrode. The Ips increased linearly with increase of DNA bases concentration. A wide response range was observed for each base (~4 orders for guanine (GA) and adenine (A); and ~2.5 orders for thymine (T) and cytosine (C)) with DLs of 0.15, 4.44, 133.0 and 230.0 nM, respectively. The electrode was applied for determination of calf‐thymus DNA bases. The value obtained for [(GA+C)/(A+T)], 0.78, is in good agreement with standard value, 0.77.  相似文献   

19.
《Electroanalysis》2006,18(17):1722-1726
The electrochemical properties of L ‐cysteic acid studied at the surface of p‐bromanil (tetrabromo‐p‐benzoquinone) modified carbon paste electrode (BMCPE) in aqueous media by cyclic voltammetry (CV) and double step potential chronoamperometry. It has been found that under optimum condition (pH 7.00) in cyclic voltammetry, the oxidation of L ‐cysteic acid at the surface of BMCPE occurs at a half‐wave potential of p‐bromanil redox system (e.g., 100 mV vs. Ag|AgCl|KClsat), whereas, L ‐cysteic acid was electroinactive in the testing potential ranges at the surface of bare carbon paste electrode. The apparent diffusion coefficient of spiked p‐bromanil in paraffin oil was also determined by using the Cottrell equation. The electrocatalytic oxidation peak current of L ‐cysteic acid exhibits a linear dependency to its concentration in the ranges of 8.00×10?6 M–6.00×10?3 M and 5.2×10?7 M–1.0×10?5 M using CV and differential pulse voltammetry (DPV) methods, respectively. The detection limits (2σ) were determined as 5.00×10?6 M and 4.00×10?7 M by CV and DPV methods. This method was used as a new, selective, rapid, simple, precise and suitable voltammetric method for determination of L ‐cysteic acid in serum of patient's blood with migraine disease.  相似文献   

20.
The poly(m‐toluidine) film was prepared by using the repeated potential cycling technique in an acidic solution at the surface of carbon paste electrode. Then transition metal ions of Ni(II) were incorporated to the polymer by immersion of the modified electrode in a 0.2 M NiSO4, also the electrochemical characterization of this modified electrode exhibits stable redox behavior of the Ni(III)/Ni(II) couple. The electrocatalytic ability of Ni(II)/poly(m‐toluidine)/modified carbon paste electrode (Ni/PMT/MCPE) was demonstrated by electrocatalytic oxidation of hydrogen peroxide with cyclic voltammetry and chronoamperometry methods in the alkaline solution. The effects of scan rate and hydrogen peroxide concentration on the anodic peak height of hydrogen peroxide oxidation were also investigated. The catalytic oxidation peak current showed two linear ranges with different slopes dependent on the hydrogen peroxide concentration and the lower detection limit was 6.5 μM (S/N=3). The catalytic reaction rate constant, (kh), was calculated 5.5×102 M?1 s?1 by the data of chronoamperometry. This modified electrode has many advantages such as simple preparation procedure, good reproducibility and high catalytic activity toward the hydrogen peroxide oxidation. This method was also applied as a simple method for routine control and can be employed directly without any pretreatment or separation for analysis cosmetics products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号