首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work,we reported a simultaneous determination approach for Pb(II),Cd(II)and Zn(II)atμg L 1concentration levels using differential pulse stripping voltammetry on a bismuth film electrode(BiFE).The BiFE could be prepared in situ when the sample solution contained a suitable amount of Bi(NO)3,and its analytical performance was evaluated for the simultaneous determination of Pb(II),Cd(II)and Zn(II)in solutions.The determination limits were found to be 0.19μg L 1for Zn(II),and0.28μg L 1for Pb(II)and Cd(II),with a preconcentration time of 300 s.The BiFE approach was successfully applied to determine Pb(II),Cd(II)and Zn(II)in tea leaf and infusion samples,and the results were in agreement with those obtained using an atomic absorption spectrometry approach.Without Hg usage,the in situ preparation for BiFE supplied a green and acceptability sensitive method for the determination of the heavy metal ions.  相似文献   

2.
《Electroanalysis》2017,29(3):880-889
A new method for modifying electrodes with Ag nanoparticles (AgNPs) using electrospray deposition for sensitive, selective detection of Zn(II), Cd(II), and Pb(II) in aerosol samples when combined with Bismuth and Nafion coating and square‐wave anodic stripping voltammetry (SWASV) is reported. Carbon stencil‐printed electrodes (CSPEs) fabricated on a polyethylene transparency (PET) sheet were produced for an inexpensive, simple to fabricate, disposable sensor that can be used with the microliter sample volumes for analysis. Sensor performance was improved by modifying the electrode surface with electrospray‐deposited AgNPs. The use of electrospray deposition resulted in more uniform particle dispersion across the electrode surface when compared to drop‐casting. Using AgNP‐modified electrodes combined with Bi and Nafion, experimental detection limits (LODs) of 5.0, 0.5, and 0.1 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively, were achieved. The linear working ranges were 5.0–400.0 μg L−1, 0.5–400.0 μg L−1, and 0.1–500.0 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively. Interference studies showed Cu(II) was the only metal that interfered with this assay but inference could be eliminated with the addition of ferricyanide directly to the sample solution. This electrochemical sensor was applied for the simultaneous determination of Zn(II), Cd(II), and Pb(II) within source particulate matter (PM) samples collected on filters using an aerosol test chamber.  相似文献   

3.
This paper describes the development of a methodology for quantification of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments by anodic stripping voltammetry (ASV) automated by Sequential Injection Analysis (SIA) using a graphite screen printed sensor modified with mercury. Determinations were made by standard addition automated by the SIA system. The limits of detection and quantification were, respectively, 1.3 and 4.3 µg L?1 for Cu(II), 1.4 and 4.6 µg L?1 for Pb(II), 0.6 and 1.8 µg L?1 for Cd(II) and 4.2 and 14 µg L?1 for Zn(II). These limits were obtained for a sample volume of 1000 µL, flow rate of 10 µL s?1 (during the deposition step), and utilizing 3 flow reversals (volume of reversion=950 µL), totalizing a deposition time of 315 s. The potentiostat worked synchronically with the SIA system applying the conditioning potential of ?0.1 V vs. pseudo reference of Ag (100 s), deposition potential of ?1.0 V for Cu(II), Pb(II) and Cd(II) or ?1,3 V for Zn(II), square wave frequency of 100 Hz, potential step of 6 mV and pulse height of 40 mV. For quantification of Zn(II) in sediment extracts, deposition of Ga0 on the working electrode was necessary to avoid the formation of intermetallic between Zn0 and Cu0. The accuracy of the method was assessed by spike and recovery experiments in water samples which resulted recovery rates near 100 % of the spiked concentrations. Recoveries of concentrations in the certified sediment sample CRM‐701 undergoing the three steps sequential extraction procedure of BCR varied from 71.7 % for Zn(II) in the acetic acid extract to 112.4 % for Cu(II) in the oxidisable fraction, confirming that the standard addition approach corrected the matrix effects in the complex samples of sediment extracts.  相似文献   

4.
The antimony film microelectrode (SbFME) is presented for measuring trace heavy metal ions in combination with anodic stripping voltammetry. The SbFME was tested in model solutions of 0.01 M HCl containing Cd(II) and Pb(II) in the presence of dissolved oxygen. The microsensor exhibited good linear behavior in the examined concentration range 20 μg L−1 to 100 μg L−1 and LoD of 1.9 and 3.1 μg L−1 for Cd(II) and Pb(II), respectively. The suitability of SbFME for measuring trace levels of Cu(II) was demonstrated using the standard reference material of natural water exploiting the sensor's specific characteristic of low re‐oxidation signal for antimony.  相似文献   

5.
A cost-effective sequential injection system incorporating with an in-line UV digestion for breakdown of organic matter prior to voltammetric determination of Zn(II), Cd(II), Pb(II) and Cu(II) by anodic stripping voltammetry (ASV) on a hanging mercury drop electrode (HMDE) of a small scale voltammetric cell was developed. A low-cost small scale voltammetric cell was fabricated from disposable pipet tip and microcentrifuge tube with volume of about 3 mL for conveniently incorporated with the SI system. A home-made UV digestion unit was fabricated employing a small size and low wattage UV lamps and flow reactor made from PTFE tubing coiled around the UV lamp. An in-line single standard calibration or a standard addition procedure was developed employing a monosegmented flow technique. Performance of the proposed system was tested for in-line digestion of model water samples containing metal ions and some organic ligands such as strong organic ligand (EDTA) or intermediate organic ligand (humic acid). The wet acid digestion method (USEPA 3010a) was used as a standard digestion method for comparison. Under the optimum conditions, with deposition time of 180 s, linear calibration graphs in range of 10-300 μg L−1 Zn(II), 5-200 μg L−1 Cd(II), 10-200 μg L−1 Pb(II), 20-400 μg L−1 Cu(II) were obtained with detection limit of 3.6, 0.1, 0.7 and 4.3 μg L−1, respectively. Relative standard deviation were 4.2, 2.6, 3.1 and 4.7% for seven replicate analyses of 27 μg L−1 Zn(II), 13 μg L−1 Cd(II), 13 μg L−1 Pb(II) and 27 μg L−1 Cu(II), respectively. The system was validated by certified reference material of trace metals in natural water (SRM 1640 NIST). The developed system was successfully applied for speciation of Cd(II) Pb(II) and Cu(II) in ground water samples collected from nearby zinc mining area.  相似文献   

6.
The present article reports the application of Thiosemicarbazide‐modified multiwalled carbon nanotubes (MWCNTs‐TSC) as a new, easily prepared selective and stable solid sorbent for the preconcentration of trace Co(II), Cd(II), Cu(II) and Zn(II) ions in aqueous solution prior to the determination by flame atomic absorption spectrometry. The studied metal ions can be adsorbed quantitatively on MMWNTs at pH 5.0 and then eluted completely with HNO3 (1.5 mol L?1) prior to their determination by flame atomic absorption spectrometry. The separation/preconcentration conditions of analytes were investigated, including the pH, the sample flow rate and volume, the elution condition and the interfering ions. The maximum adsorption capacity of the adsorbent at optimum conditions were found to be 32.5, 27.3, 44.5 and 34.1 mg g?1 for Co(II), Cd(II), Cu(II) and Zn(II), and the detection limits of the method were found to be 0.28, 0.13, 0.21 and 0.17 μg L?1, respectively. The proposed method was successfully applied for extraction and determination of the analytes in well water, sea water, wastewater, soil, and blood samples.  相似文献   

7.
Total dissolved and labile concentrations of Cd(II), Cu(II), Ni(II) and Pb(II) were determined at six locations of the Bourgas Gulf of the Bulgarian Black Sea coast. Solid phase extraction procedure based on monodisperse, submicrometer silica spheres modified with 3-aminopropyltrimethoxysilane followed by the electrothermal atomic absorption spectrometry (ETAAS) was developed and applied to quantify the total dissolved metal concentrations in sea water. Quantitative sorption of Cd, Cu, Ni and Pb was achieved in the pH range 7.5–8, for 30?min, adsorbed elements were easily eluted with 2?mL 2?mol?L?1 HNO3. Since the optimal pH for quantitative sorption coincides with typical pH of Black Sea water (7.9–8.2), on-site pre-concentration of the analytes without any additional treatment was possible. Detection limits achieved for total dissolved metal quantification were: Cd 0.002?µg?L?1, Cu 0.005?µg?L?1, Ni 0.03?µg?L?1, Pb 0.02?µg?L?1 and relative standard deviations varied from 5–13% for all studied elements (for typical Cd, Cu, Ni and Pb concentrations in Black Sea water). Open pore diffusive gradients in thin films (DGT) technique was employed for in-situ sampling and pre-concentration of the sea water and in combination with ETAAS was used to determine the proportion of dynamic (mobile and kinetically labile) species of Cd(II), Cu(II), Ni(II) and Pb(II) in the sea water. Obtained results showed strong complexation for Cu and Pb with sea water dissolved organic matter. The ratios between DGT-labile and total dissolved concentrations found for Cu(II) and Pb(II) were in the range 0.2–0.4. For Cd and Ni, these ratios varied from 0.6 to 0.8, suggesting higher degree of free and kinetically labile species of these metals in sea water.  相似文献   

8.
A solid phase extraction system for separation and preconcentration of trace amounts of Pb(II), Ni(II), Cd(II) and Cu(II) is proposed. The procedure is based on the adsorption of Pb2+, Ni2+, Cd2+ and Cu2+ ions on a column of 1-(2-pyridylazo)-2-naphthol (PAN) immobilised on surfactant-coated clinoptilolite prior to their determinations by Flame Atomic Absorption Spectroscopy (FAAS). The effective parameters including pH, sample volume, sample flow rate and eluent flow rate were also studied. The analytes collected on the column were eluted with 5 mL of 1 mol L?1 nitric acid. A concentration factor of 180 can be achieved by passing 900 mL of sample through the column. The detection limits (3 s) for Cd, Cu, Pb and Ni were found to be 0.28, 0.12, 0.44 and 0.46 µg L?1, respectively. The relative SDs at 10 µg L?1 (n = 10) for analytes were in the range of 1.2–1.4%. The method was applied to the determination of Pb, Ni, Cd and Cu in water samples.  相似文献   

9.
This paper describes a comparative study of the simultaneous determination of Cd(II), Pb(II), Tl(I), and Cu(II) in highly saline samples (seawater, hydrothermal fluids, and dialysis concentrates) by ASV using the mercury‐film electrode (MFE) and the bismuth‐film electrode (BiFE) as working electrodes. The features of MFE and BiFE as working electrodes for the single‐run ASV determinations are shown and their performances are compared with that of HMDE under similar conditions. It was observed that the stripping peak of Tl(I) was well separated from Cd(II) and Pb(II) peaks in all the studied saline samples when MFE was used. Because of the severe overlapping of Bi(III) and Cu(II) stripping peaks in the ASV using BiFE, as well as the overlapping of Pb(II) and Tl(I) stripping peaks in the ASV using HMDE, the simultaneous determination of these metals was not possible in highly saline medium using these both working electrodes. The detection limits calculated for the metals using MFE and BiFE (deposition time of 60 s) were between 0.043 and 0.070 μg L?1 for Cd(II), between 0.060 and 0.10 μg L?1 for Pb(II) and between 0.70 and 8.12 μg L?1 for Tl(I) in the saline samples studied. The detection limits calculated for Cu(II) using the MFE were 0.15 and 0.50 μg L?1 in seawater/hydrothermal fluid and dialysis concentrate samples, respectively. The methods were applied to the simultaneous determination of Cd(II), Pb(II), Tl(I), and Cu(II) in samples of seawater, hydrothermal fluids and dialysis concentrates.  相似文献   

10.
Nafion‐coated antimony film electrode (NCAFE) was prepared in situ by simultaneously plated antimony with analytes, and applied to the determination of trace Pb(II) and Cd(II) in non‐deaerated solutions by differential pulse anodic stripping voltammetry (DPASV). Various experimental parameters, which influenced the response of the NCAFE to those metals, were thoroughly optimized and discussed. The results indicated that the sensitivity and resistance to surfactants at the NCAFE were remarkably improved with relative to the antimony film electrode (AFE). In the presence of 5 mg·L?1 gelatin, the peak heights at the NCAFE showed 4‐fold enhancement for Pb and a 9‐fold enhancement for Cd over a bare AFE. Reproducibility of the sensor was satisfactory, and the relative standard deviations were 4.8% for 20 μg·L?1 Pb and 3.2% for 25 μg·L?1 Cd (n=15) with preconcentration time of 180 s. The determination limits (S/N=3) of this sensor were determined to be 0.15 μg·L?1 for Pb and 0.30 μg·L?1 for Cd with accumulation time of 300 s. The NCAFE was successfully applied to determining Pb(II) and Cd(II) in vegetable and water samples with satisfactory results.  相似文献   

11.
A disposable screen‐printed device containing working, auxiliary, and reference electrodes is proposed for the simultaneous voltammetric determination of Zn(II), Pb(II), Cu(II), and Hg(II) in ethanol fuel. The working electrode was printed using an ink modified with 2‐benzothiazole‐2‐thiol organofunctionalized SBA‐15 silica, in order to increase sensitivity. The performance of this electrode was compared with that of bare and SBA‐15‐modified electrodes. After optimizing the experimental parameters, the device was applied in determination of the analytes in commercial ethanol fuel samples, using 0.10 mol L?1 KCl/ethanol ratios of 30 : 70 (v/v), with [H+]=10?5 mol L?1. After 5 min of preconcentration at ? 1.3 V (vs. pseudo‐Ag/AgCl), four well‐resolved signals were obtained, enabling simultaneous determination of the four analytes using a differential pulse anodic stripping voltammetry (DPASV) procedure. The limits of detection were 0.30, 0.065, 0.030, and 0.046 µmol L?1 for Zn(II), Pb(II), Cu(II), and Hg(II), respectively. The results of these analyses were in agreement with those obtained using graphite furnace atomic absorption spectroscopy (GFAAS) for Pb(II), Cu(II), and Hg(II), and high‐resolution continuum source flame atomic absorption spectrometry (HR‐CS‐FAAS) for Zn2+, at a 95 % confidence level. Analytes originally present in the samples could be detected, and the interference of some cations and anions was evaluated.  相似文献   

12.
In the present paper novel column solid phase extraction procedure was developed for the determination of Cd(II) and Pb(II) in cows', goats', ewes', buffalos' and humans' milk samples using newly synthesized reagent 2,2′‐DPED3P (2,2′‐{[1,2‐diphenylethane‐1,2‐diylidene]dinitrilo}diphenol) for preconcentration and separation prior to differential pulse polarography using amberlite XAD‐2 in the ranges of pH 4.0–5.0. The sorbed elements were subsequently eluted with 10 mL of 2 M HCl elutes were analysed by differential pulse polarography (DPP). The interference of foreign ions has also been studied. Effects of various instrumental parameters are investigated and received conditions are optimized. The total metal concentration of the milk samples in the study area were in the following ranges 0.030–0.090 μg L?1 of Cd(II), 0.009–0.026 μg L?1 of Pb(II) respectively. The limits of detections were found to be 0.020 and 0.024 μg L?1 for Cd(II) and Pb(II) respectively by applying a preconcentration factor ~40. The proposed enrichment method was applied successfully for the determination of metal ions in cows', goats', ewes', buffalos' and humans' milk samples.  相似文献   

13.
A novel UV-VIS spectrophotometric method was developed in this study by using solid phase extraction procedure for the simultaneous preconcentration, separation and determination of trace levels of Pb (II), Cd (II) and Zn (II) ions in various water samples by using Amberlite N,N-bis(salicylidene)cyclohexanediamine (SCHD) resin. This study presents the results of experimental procedures carried out like the adsorption of analytes to the resin, influences of some analytical parameters that effect the recovery such as pH, sample volume, sample flow rate, eluent type and concentration, eluent volume, eluent flow rate and the effects of alkaline metals, earth alkaline metals and some other transition metals. The analytes in the samples with the adjusted pH range of 4–7 were adsorbed on XAD-4-SCHD resin and eluted by using 1.0 mol L?1 nitric acid. The amounts of ions were determined by using UV-VIS spectrometer. The limits of detection were 0.03, 0.07 and 0.05 µg mL?1 for Pb (II), Cd (II) and Zn (II), respectively. The accuracy of the method was assured by the analysis of the certified standard water sample NW-TMDA-70.2 and the observed recoveries were above 93%. Different environmental water samples that contain trace amounts of Pb (II), Cd (II) and Zn (II) were analysed by using the method developed in this study. Same samples were also analysed by ICP-MS for comparison and almost the similar results were observed. The method developed in this study was successfully applied to the various environmental water samples to determine the trace levels of Pb (II), Cd (II) and Zn (II) ions.  相似文献   

14.
《Analytical letters》2012,45(11):2273-2284
Abstract

A novel voltammetric method—anodic—using a bismuth/poly(aniline) film electrode has been developed for simultaneous measurement of Pb(II) and Cd(II) at low µg L?1 concentration levels by stripping voltammetry. The results confirmed that the bismuth/poly(aniline) film electrode offered high‐quality stripping performance compared with the bismuth film electrode. Well‐defined sharp stripping peaks were observed for Pb(II) and Cd(II), along with an extremely low baseline. The detection limits of Pb(II) and Cd(II) are 1.03 µg L?1 and 1.48 µg L?1, respectively. The bismuth/poly (aniline) electrode has been applied to the determination of Pb(II) in tap water samples with satisfactory results.  相似文献   

15.
An electrochemical sensor for the simultaneous determination of Cd(II) and Pb(II) by square wave anodic stripping voltammetry (SWASV) in bivalve mollusks using a glassy carbon electrode modified with electrochemically reduced graphene oxide has been developed. The modified surface was characterized by cyclic voltammetry, high resolution scanning electron microscopy (HR‐SEM), and Raman spectroscopy. The optimum conditions were optimized and a linear range was observed from 15–105 μg L?1 with a limits of detection of 15 μg L?1 for Cd(II) and Pb(II). The methodology was validated and applied in different samples of commercial bivalve mollusks with satisfactory results. The high conductivity and greater surface area of the modifying agent improves the preconcentration capacity of the electrochemical sensor, allowing to develop a simple, rapid and sensitive analysis in the detection of lead and cadmium in marine resources.  相似文献   

16.
A multiwalled carbon nanotubes–sodium dodecyl benzene sulfonate (MWCNTs–NaDBS) modified stannum film electrode was employed for the determination of cadmium(II) and zinc(II). The Sn/MWCNTs‐NaDBS film electrode was prepared by applying MWCNTs–NaDBS suspension to the surface of the GCE, while the Sn film was plated in situ simultaneously with the target metal ions. Under optimal conditions, linear calibration curves were obtained in a range of 5.0 ?100.0 μg L?1 with detection limits of 0.9 μg L?1 for zinc(II) and 0.8 μg L?1 for cadmium(II), respectively. This film electrode was successfully applied to the determination of Zn(II) and Cd(II) in tap water sample.  相似文献   

17.
This paper describes the development and validation of a sequential injection (SI) anodic stripping voltammetry (ASV) method using the hanging mercury drop electrode for accumulation of the heavy metal cations Cu(II), Pb(II) and Cd(II). The method was applied to wastewater samples after proper acid digestion in open vessels to eliminate matrix effects. For a deposition time of 90 s at the flow rate of 10 μl s−1, the detection limits of the method were 0.06, 0.09 and 0.16 μmol L−1 for Cd, Pb and Cu, respectively. Under these conditions the linear dynamic range was between 0.20 and 9.0 μmol L−1 and the sampling frequency was 30 analyses per hour. The relative standard deviation of the method was 3%(n=7) at the concentration level of 2.0 μmol L−1. The accuracy of the method was evaluated by spiking the samples with known amounts of the metal cations, and by comparison with an independent analytical technique, the inductively coupled plasma atomic emission spectroscopy (ICP-AES). Average recoveries were around of 84%, and the results showed no evidence of systematic errors in comparison to the ICP-AES.  相似文献   

18.
A highly selective thiol-functionalized ionic liquid (thiol-FIL) was synthesized and characterized by FT-IR and ESI mass spectroscopy. The capability of thiol-FIL to extract Cd(II), Ni(II), Cr(III) and Pb(II) was evaluated. It is found that thiol-FIL possesses high selectivity for Cd(II), and this has led to a method for determination of Cd(II) by flame atomic absorption spectrometry that is free of interferences by up to a 1,000-fold excess of Na(I), Mg(II), Ca(II), Mn(II), Fe(III), Al(III), Cu(II), Zn(II), Ni(II), Cr(III), Co(II), As(III), Pb(II), and Hg(II). With extraction equilibrium time of 1 min, a good linearity (r = 0.9998) and a detection limit of 0.39 μg?L?1 were obtained. The precision (RSD) for 11 replicate measurements of 10 μg?L?1 Cd was 1.6%. The method was validated using certified reference materials. The recoveries of cadmium in spiked real samples ranged from 97% to 102%.  相似文献   

19.
A new chelating matrix has been prepared by immobilising sulfanilamide (SA) on silica gel (SG) surface modified with 3-chloropropyltrimethoxysilane as a sorbent for the solid-phase extraction (SPE) Cu(II), Zn(II) and Ni(II). The determination of metal ions in aqueous solutions was carried out by inductively coupled plasma optical emission spectrometry (ICP-OES). Experimental conditions for effective sorption of trace levels of Cu(II), Zn(II) and Ni(II) were optimised with respect to different experimental parameters using the batch and column procedures. The presence of common coexisting ions does not affect the sorption capacities. The maximum sorption capacity of the sorbent at optimum conditions was found to be 34.91, 19.07 and 23.62 mg g?1 for Cu(II), Zn(II) and Ni(II), respectively. The detection limit of the method defined by IUPAC was found to be 1.60, 0.50 and 0.61 µg L?1 for Cu(II), Zn(II) and Ni(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 4.0% (n = 8). The method was applied to the recovery of Cu(II), Zn(II) and Ni(II) from the certified reference material (GBW 08301, river sediment) and to the simultaneous determination of these cations in different water samples with satisfactory results.  相似文献   

20.
Synthesis of Mesoporous Lanthanum Phosphate and Its Use as a Novel Sorbent   总被引:2,自引:0,他引:2  
Mesoporous lanthanum phosphate was synthesized by supramolecular self-assembly of cetyltrimethylammo-nium bromide and lanthanum nitrate following digestion in phosphoric acid.TGA-DTA,XRD and SEM were em-ployed to study the uncalcined and calcined materials.Sorption behavior of Cr(Ⅲ),Mn(Ⅱ),Fe(Ⅲ),Co(Ⅱ),Ni(Ⅱ),Cu(Ⅱ),Zn(Ⅱ),Cd(Ⅱ),Ba(Ⅱ),Hg(Ⅱ)and Pb(Ⅱ)cations was studied on such materials in water,3 mol·L~(-1)ammonia,0.01 mol.L~(-1)potassium ferrocyanide and 0.01 mol·L~(-1)potassium ferricyanide solutions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号