首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and reliable method for the evaluation of triacylglycerols (TAGs) in vegetable oils by capillary electrochromatography (CEC) with UV-Vis detection, using octadecyl acrylate (ODA) ester-based monolithic columns, has been developed. The percentages of the porogenic solvents in the polymerization mixture, and the mobile phase composition, were optimized. The optimum monolith was obtained at the following ratios: 40:60% (wt/wt) monomers/porogens, 60:40% (wt/wt) ODA/1,3-butanediol diacrylate and 23:77% (wt/wt) 1,4-butanediol/1-propanol (14 wt% 1,4-butanediol in the polymerization mixture). A satisfactory resolution between TAGs was achieved in less than 12 min with a 65:35 (v/v) acetonitrile/2-propanol mixture containing 5 mM ammonium acetate. The method was applied to the analysis of TAGs of vegetable oil samples. Using linear discriminant analysis of the CEC TAG profiles, the vegetable oils belonging to six different botanical origins (corn, extra virgin olive, hazelnut, peanut, soybean and sunflower) were correctly classified with an excellent resolution among all the categories.  相似文献   

2.
The separation and determination of tocopherols (Ts) in vegetable oils by CEC using methacrylate ester-based monolithic columns has been developed. The effects of pore size of the monolithic columns were studied, and the composition of mobile phase was optimized. The optimal pore size of the monolith was obtained with 12 wt% 1,4-butanediol in the polymerization mixture. Excellent resolution between tocopherols was achieved within 10 min analysis time with a 99:1 v/v MeOH-aqueous buffer containing 5 mM tris(hydroxymethyl)aminomethane at pH 8.0. The LODs were lower than 2.3 microg/mL, and interday and column-to-column reproducibilities at 25 microg/mL were better than 5.6%. Using a 93:7 v/v MeOH-aqueous buffer, both tocopherols and tocotrienols (T(3)s) of grapeseed and palm oils were resolved. Application to the detection of olive oil adulteration with low-cost edible oils was demonstrated.  相似文献   

3.
Lauryl methacrylate (LMA)‐ester based monolithic columns photo‐polymerized using lauroyl peroxide (LPO) as initiator were prepared, and their morphological and CEC properties were studied. The composition of the polymerization mixture (i.e. ratios of monomers/porogenic solvents, 1,4‐butanediol/1‐propanol and LMA/crosslinker) was optimized. The morphological and chromatographic properties of LMA columns were evaluated by means of SEM pictures and van Deemter plots of PAHs, respectively. The polymerization mixture selected as optimal provided a fast separation of a mixture of PAHs with excellent efficiencies (minimum plate heights of 8.9–11.1 μm). Satisfactory column‐to‐column (RSD<4.5%) and batch‐to‐batch reproducibilities (RSD<6.3%) were achieved. The LMA columns photo‐polymerized with LPO were compared with those prepared with AIBN. Using PAHs, alkylbenzenes and basic compounds for testing, the columns obtained with LPO gave the best compromise between efficiency, resolution and analysis time.  相似文献   

4.
Lauryl methacrylate‐based (LMA) monolithic columns for CEC, prepared using either thermal initiation or by UV‐irradiation in the presence of AIBN have been compared. Thermal polymerization was carried out at 70°C for 20 h. For UV initiation, the effects of the time exposure to UV light and irradiation energy were investigated. For each initiation process, the influence of composition of porogenic solvent (1,4‐butanediol/1‐propanol ratio) on the physical and electrochromatographic properties of the resulting monoliths was also evaluated. Photochemically lauryl methacrylate stationary phases initiated showed higher permeabilities and better efficiencies than those prepared by thermal initiation. After optimization of polymerization mixture, photopolymerized columns provided a permeability of 4.25×10?13 m2 and a minimum plate height of 13.4 μm for a mixture of polycyclic aromatic hydrocarbons. Similar column‐to‐column and batch‐to‐batch reproducibilities, with RSD values below 11.6 and 11.0 % for the thermal‐ and UV‐initiated columns, respectively, were obtained.  相似文献   

5.
Monolithic capillary columns have been prepared in fused‐silica capillaries by radical co‐polymerization of ethylene dimethacrylate and butyl methacrylate in the presence of porogen solvent mixtures containing various concentration ratios of 1‐propanol, 1,4‐butanediol, and water with azobisisobutyronitrile as the initiator of the polymerization reaction. The through pores in organic polymer monolithic columns can be characterized by “equivalent permeability particle size”, and the mesopores with stagnant mobile phase by “equivalent dispersion particle size”. Increasing the concentration of propanol in the polymerization mixture diminishes the pore volume and size in the monolithic media and improves the column efficiency, at a cost of decreasing permeability. Organic polymer monolithic capillary columns show similar retention behaviour to packed alkyl silica columns for compounds with different polarities characterized by interaction indices, Ix, but have different methylene selectivities. Higher concentrations of propanol in the polymerization mixture increase the lipophilic character of the monolithic stationary phases. Best efficiencies and separation selectivities were found for monolithic columns prepared using 62–64% propanol in the porogen solvent mixture. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra‐column contributions.  相似文献   

6.
Vinyl ester‐based monoliths are proposed as a new group of stationary phase for CEC. The capillary monolithic columns were prepared by using two vinyl ester monomers, vinyl pivalate (VPV), and vinyl decanoate (VDC) by using ethylene dimethacrylate (EDMA) as the cross‐linking agent, and 2‐acrylamido‐2‐methylpropane sulfonic acid as the charge‐bearing monomer. The monoliths with different pore structures and permeabilities were obtained by varying the type and composition of the porogen mixture containing isoamyl alcohol and 1,4‐butanediol. The electrochromatographic separation of alkylbenzenes was successfully performed by using an acetonitrile/aqueous buffer system as the mobile phase in a CEC system. Vinyl ester monoliths with short alkyl chain length (i.e. poly(VPV‐co‐EDMA) exhibited better separation performance compared with the monolith with long alkyl chain length (i.e. poly(VDC‐co‐EDMA). In the case of VPV‐based monoliths, the theoretical plate numbers higher than 250 000 plates/m were achieved by using a porogen mixture containing 33% v/v of isoamyl alcohol. For both VDC and VPV‐based monoliths, the column efficiency was almost independent of the superficial velocity in the range of 2–12 cm/min.  相似文献   

7.
A polymethacrylate‐based strong cation‐exchange capillary monolithic column was prepared by in‐situ copolymerization for the fast separation of proteins. Glycidyl methacrylate (GMA) was used as monomer, ethylenedimethacrylate (EDMA) as cross link agent and the mixture of 1‐propanol, 1,4‐butanediol and water as porogen solvent. The monolith was sulfonated using 1 mol/L Na2SO3 based on a ring opening of epoxides. The influences of the contents of the porogen solvent and GMA and the various concentration ratios of 1‐propanol to 1,4‐butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of the monolith were characterized by SEM and mercury intrusion porosimetry, respectively. Using only 1.5 cm length of this monolithic capillary column, four kinds of proteins, trypsin, cytochrome C, lysozyme (egg white) and egg albumin, were successfully separated from each other in 5 min at a high flow rate of 110 mm/s.  相似文献   

8.
Monolithic columns were synthesized inside 1.02 mm internal diameter fused‐silica lined stainless‐steel tubing. Styrene and butyl, hexyl, lauryl, and glycidyl methacrylates were the functional monomers. Ethylene glycol dimethacrylate and divinylbenzene were the crosslinkers. The glycidyl methacrylate polymer was modified with gold nanoparticles and dodecanethiol (C12). The separation of alkylbenzenes was investigated by isocratic elution in 60:40 v/v acetonitrile/water. The columns based on polystyrene‐co‐divinylbenzene and poly(glycidyl methacrylate)‐co‐ethylene glycol dimethacrylate modified with dodecanethiol did not provide any separation of alkyl benzenes. The poly(hexyl methacrylate)‐co‐ethylene glycol dimethacrylate and poly(lauryl methacrylate)‐co‐ethylene glycol dimethacrylate columns separated the alkyl benzenes with plate heights between 30 and 60 μm (50 μL min?1 and 60°C). Similar efficiency was achieved in the poly(butyl methacrylate)‐co‐ethylene glycol dimethacrylate column, but only at 10 μL min?1 (0.22 mm s?1). Backpressures varied from 0.38 MPa in the hexyl methacrylate to 13.4 MPa in lauryl methacrylate columns (50 μL min?1 and 60°C). Separation of proteins was achieved in all columns with different efficiencies. At 100 μL min?1 and 60°C, the lauryl methacrylate columns provided the best separation, but their low permeability prevented high flow rates. Flow rates up to 500 μL min?1 were possible in the styrene, butyl and hexyl methacrylate columns.  相似文献   

9.
A novel ionic liquid (IL) monolithic capillary column was successfully prepared by thermal free radical copolymerization of IL (1-vinyl-3-octylimidazolium chloride, ViOcIm+Cl) together with lauryl methacrylate (LMA) as the binary functional monomers and ethylene dimethacrylate (EDMA) as the cross-linker in binary porogen. The proportion of monomers, porogens and cross-linker in the polymerization mixture was optimized in detail. The resulting IL-monolithic column could not only generate a stable reversed electroosmotic flow (EOF) in a wide pH range (2.0–12.0), but also effectively eliminate the wall adsorption of the basic analytes. The obtained IL-monolithic columns were examined by scanning electron microscopy (SEM) and Fourier transform infrared (FT-IR). These results indicated that the IL-monolithic capillary column possessed good pore properties, mechanical stability and permeability. The column performance was also evaluated by separating different kinds of compounds, such as alkylbenzenes, thiourea and its analogues, and amino acids. The lowest plate height of ∼6.8 μm was obtained, which corresponded to column efficiency (theoretical plates, N) of ∼147,000 plates m−1 for thiourea. ILs, as a new type of functional monomer, present a promising option in the fabrication of the organic polymer-based monolithic columns in CEC.  相似文献   

10.
In this study, vinyl phenyl boronic acid modified lauryl methacrylate‐based monolithic column was successfully prepared for cation exchange/hydrophobic interaction monolithic chromatography of small molecules and proteins in nano LC. The polymeric mixture consisted of lauryl methacrylate, vinyl phenyl boronic acid as cation exchanger, ethylene dimethacrylate as cross‐linker, polyethylene glycol and methanol as binary porogenic solvent, and azobisisobutyronitrile as initiator. The resulting monolith showed good permeability and mechanical stability. Different ratios of monomer and porogens were used for optimizing the properties of the column. The monolithic column performance with respect to hydrophobic and cation exchange interactions was assessed by the separation a series of alkyl benzenes and anilines, respectively. cis‐Diol‐containing compounds such as phenols were also utilized to evaluate the retention behaviors of the vinyl phenyl boronic acid modified monolithic column. The monolithic column showed cation exchange interactions in the separation of aniline compounds. Theoretical plate number up to 52 000 plates/m was successfully achieved. The prepared monolith was further applied to the proteins with different acetonitrile content.  相似文献   

11.
Monolithic capillary columns for hydrophobic interaction chromatography (HIC) have been prepared by thermally initiated, single-step in situ polymerization of mixtures of monovinyl monomers including butyl methacrylate and/or 2-hydroxyethyl methacrylate, with a divinyl crosslinker glycerol dimethacrylate or 1,4-butanediol dimethacrylate using two different porogen systems. Two porogenic solvent mixtures were used; one "hydrophilic", consisting of water, butanediol, and propanol, and one "hydrophobic," comprising dodecanol and cyclohexanol. The porous structures of the monoliths were characterized and their performance was demonstrated with a separation of a mixture of myoglobin, ribonuclease A, and lysozyme under conditions typical of HIC.  相似文献   

12.
In this work,a novel kind of particulate capillary precolumns with double-end polymer monolithic frits has been developed.Firstly,the polymer monolithic frit at one end was prepared via photo-initiated polymerization of a mixture of lauryl methacrylate and ethyleneglycol dimethacrylate with 1-propanol and 1,4-butanediol as porogens and 2,2-dimethoxy-2-phenylacetophenone as a photo-initiator in UV transparent coating capillary(100 μm i.d.).Subsequently,C18 particles(5 μm,100 A) were packed into the capillary,and sealed with the polymer monolithic frit at another end.To prevent the reaction of monomers and C18 particles,the packed C18 particles were masked during UV exposure.The loading capacity of such a precolumn was determined to be about 9 μg by frontal analysis with a synthetic peptide APGDR1 YVHPF as a model sample.Furthermore,two parallel precolumns were incorporated into a two-dimensional nano-liquid chromatography(2D nano-LC) system with dual capillary trap columns for peptide trapping and concentration.Compared to 2D nano-LC system with a single trap column,such two dimensional separations could be operated simultaneously to improve the analysis throughput.All these results demonstrated that such capillary precolumns with double frits would be promising for high-throughput proteome analysis.  相似文献   

13.
This work describes the fabrication of long chain alkyl methacrylate monolithic materials for use as stationary phases in capillary liquid chromatography. After capillary inner wall surface activation with 3-(trimethoxysilyl)propyl methacrylate, monoliths were formed by copolymerization of either lauryl or stearyl methacrylate (LMA or SMA) with ethylene dimethacrylate (EDMA) as crosslinker, in the presence of azobisisobutyronitrile (AIBN) as initiator and a mixture of porogenic solvents including water, 1-propanol and 1,4-butanediol. The composition of the polymerization mixture was changed in terms of monomer, crosslinker and porogen ratio composition, in order to compare the influence of these parameters. The monoliths were prepared in 320 ??m i.d. and 200 mm length capillaries. The column morphology was characterized by optical microscopy and scanning electron microscopy (SEM). Total porosity and permeability of each column were calculated using uracil as unretained material by measuring the pressure drop across the columns as a function of linear velocity. The microglobule average size for each column was also determined using Hagen?CPoiseuille equation and compared with the SEM images. As expected, a decrease of the porogen to monomer ratio corresponded to smaller microglobules and a lower total porosity. The columns were then chromatographically evaluated; good results were obtained when these capillaries were used to separate mixtures of phenols, aromatics and drug compounds.  相似文献   

14.
Butyl methacrylate monolithic columns in 320 microm i.d. fused silica capillaries for reversed-phase capillary liquid chromatography were prepared by radical polymerization initiated thermally with azobisisobutyronitrile (AIBN). Polymerization mixture contained butyl methacrylate (BMA) as the function monomer and ethylene dimethacrylate (EDMA) as the crosslinking agent with 1,4-butanediol and 1-propanol as a binary porogen solvent. Ratio of 1,4-butanediol to 1-propanol in the porogen solvent was optimized regarding the monolithic column efficiency and performance. Total porosity, column permeability, separation impedance, Walters hydrophobicity index, retention factors, peak asymmetry factors, height equivalents to a theoretical plate and peak resolutions were used for characterization of the prepared monolithic columns. The polymerization mixture consisting of 17.8% of BMA, 21.8% of EDMA, 18.0% of 1,4-butanediol, 42.0% of 1-propanol and 0.4% AIBN generated monolithic columns of the best performance having a sufficient permeability and the lowest separation impedance. It was also demonstrated that monolithic columns of this composition exhibited good preparation reproducibility and an excellent pressure resistance when applied in capillary liquid chromatography.  相似文献   

15.
High efficiency and highly retentive monolithic silica capillary columns were obtained by polymerization of octadecyl methacrylate using alpha,alpha'-azobis-isobutyronitrile (AIBN) as a free radical initiator. Hybrid type monolithic silica columns (25 cm total length x 200 microm I.D.) prepared from a mixture of tetramethoxysilane and methyltrimethoxysilane were used as a support. The effects of the monomer and the radical initiator concentrations in the reaction mixture were examined. The performance of the columns was tested in terms of column efficiency and retention behavior by using alkylbenzenes and a few other compounds as solutes and compared with that of hybrid monolithic silica columns modified with octadecylsilyl-(N,N-diethylamino)silane (ODS-DEA). Highly retentive monolithic silica columns were obtained by polymerization at high monomer concentrations. Although a decrease in column efficiency was observed with the increase in the monomer concentration in a feed mixture, an improvement in efficiency was achieved (a plate height value lower than 10 microm) by increasing an initiator concentration without significant variations in column retention properties. Results obtained by polymerization using other monomers are also presented to demonstrate the applicability of the preparation method.  相似文献   

16.
A silica‐particle‐supported zwitterionic polymeric monolithic column, shortened as supported column (S‐column), was prepared by the in situ polymerization of methacrylic acid, ethylene dimethacrylate, and 2‐(dimethylamino)ethyl methacrylate in the presence of a ternary porogenic solvent containing water, methanol, and cyclohexanol in a 250 μm id fused‐silica capillary prepacked with 5 μm bare silica particles. In the S‐column, a thin layer of the polymers was formed around the silica particles in the form of nanoglobules, leaving the interstitial spaces between the particles free for liquid flow. The effects of the preparation conditions on the morphology of the monolith were investigated by scanning electron microscopy and backpressure measurements. The selected volumetric ratio of porogens, monomer concentration, polymerization time, and temperature are 1:1:8 (water/methanol/cyclohexanol), 25% v/v, 5 h, and 60°C, respectively. The S‐column was evaluated by comparison with its conventional organic counterpart in terms of morphology, mechanical stability, permeability, swelling–shrinking behavior, capacity, and efficiency. The results demonstrate that the S‐column is superior to its counterpart in all the terms with the exception of permeability. The above merits and zwitterionic property of the S‐column were further confirmed by separate separations of four inorganic anions and three organic cations.  相似文献   

17.
The main factors affecting the porosity of methacrylate-ester based monolithic columns were investigated. We prepared 23 monolithic capillary columns with porosity controlled by varying the proportions of butyl methacrylate and ethylene dimethacrylate monomers and of 1,4-butanediol and 1-propanol as the porogen solvent in the polymerization mixtures by thermally initiated in-situ polymerization in fused-silica capillaries. Using mixture design software, we systematically varied the composition of the polymerisation mixtures to find significant factors affecting flow-through pore formation. Multivariate analysis of the experimental data obtained for the fabricated columns yielded a model for prediction of the flow-through porosity in monolithic beds as a function of the composition of the polymerization mixture used to prepare polymethacrylate monolithic capillary columns. The mean error of prediction was lower than 8% for eight columns prepared independently of the original set of 15 columns used to derive the flow-through model. The flow-through porosity increases with increasing concentration of the binary porogen solvent mixture, the concentration of 1,4-butanediol being the main factor enhancing flow-through pore formation. On the other hand, increasing concentrations of the hydrophobic monomer butyl methacrylate and increasing concentrations of 1-propanol have a negative effect on flow-through pore formation. The capillary columns prepared with a high proportion of flow-through pores and a minimum amount of mesopores can be used for fast gradient separations of both low-molecular weight compounds and biopolymers.  相似文献   

18.
Several monolithic macroporous polymer sorbents (pore size 1–2 µm) based on alkyl methacrylates and ethylene glycol dimethacrylate as a cross-linking agent were prepared by free radical copolymerization in columns 3×150 mm. The influence of compositions of the reaction mixture and porogens and the nature of the alkyl radical in a mixture of monomers on the hydrodynamic and chromatographic characteristics of the monoliths was studied. The monoliths based on n-butyl methacrylate have rigid macroporous morphology and excellent hydrodynamic characteristics (flow rate up to 5 mL min?1). The efficiency of separation of a mixture of benzene and its derivatives in the version of reversed-phase HPLC was shown to increase with an increase in the fraction of a lauryl methacrylate additive (LMA) in the reaction mixture. The maximum separation efficiency (number of theoretical plates (tp)) was 35 000 tp m?1 for the monolith based on n-butyl methacrylate with 7% LMA in the reaction mixture.  相似文献   

19.
A surfactant-bound monolithic stationary phase based on the co-polymerization of 11-acrylamino-undecanoic acid (AAUA) is designed for capillary high performance liquid chromatography (HPLC). Using D-optimal design, the effect of the polymerization mixture (concentrations of monomer, crosslinker and porogens) on the chromatographic performance (resolution and analysis time) of the AAUA–EDMA monolithic column was evaluated. The polymerization mixture was optimized using three proteins as model test solutes. The D-optimal design indicates a strong dependence of chromatographic parameters on the concentration of porogens (1,4-butanediol and water) in the polymerization mixture. Optimized solutions for fast separation and high resolution separation, respectively, were obtained using the proposed multivariate optimization. Differences less than 6.8% between the predicted and the experimental values in terms of resolution and retention time indeed confirmed that the proposed approach is practical. Using the optimized column, fast separation of proteins could be obtained in 2.5 min, and a tryptic digest of myoglobin was successfully separated on the high resolution column. The physical properties (i.e., morphology, porosity and permeability) of the optimized monolithic column were thoroughly investigated. It appears that this surfactant-bound monolith may have a great potential as a new generation of capillary HPLC stationary phase.  相似文献   

20.
Fused-silica capillary columns (100 μm I.D.) englobing a porous monolithic stationary phase were prepared by in situ copolymerization of 2-ethylhexyl methacrylate, ethylene glycol dimethacrylate and 2-acrylamido-2-methylpropanesulfonic acid (AMPS) in the presence of a porogenic mixture containing 1-propanol, 1,4 butanediol and water. The influence of the monomers ratio and the porogen solvent composition as well as the content of AMPS in the polymerization mixture on column total porosity and efficiency was investigated to attain minimum HETP values for the reversed-phase capillary electrochromatography separation of bioflavonoids. For the most promising column, the van Deemter plots, in both μ-HPLC and CEC, were also evaluated. In CEC the reduced plate height was found almost constant (1.6–2.0) within the range of linear mobile phase velocity between 0.2–2.0 mm s−1. The chemical and mechanical stabilities of the monolithic column over a wide range of buffer pH (2-10) and time were satisfactory. Furthermore, the effects of mobile phase parameters, such as buffer concentration and organic modifier content, on the electroosmotic flow were studied systematically. CEC separations of standard mixtures of polyphenols, including flavonols, flavanones and flavanones-7-O-glycosides, were accomplished in less than 8 min. The CEC separation of the major flavanone glycoside constituents in the extract from a freshly squeezed grapefruit juice was also reported.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号