首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Parathyroid hormone (PTH) is a common clinical marker whose quantification relies on immunoassays, giving variable results as batch, brand, or target epitope changes. Sheathless CE‐ESI‐MS, combining CE resolution power and low‐flow ESI sensitivity, was applied to the analysis of PTH in its native conformation in the presence of related forms. Fused silica and neutral‐coated capillaries were investigated, as well as preconcentration methods such as transient isotachophoresis, field‐amplified sample injection (FASI), and electrokinetic supercharging (EKS). The method for the separation of PTH and its variants was first developed using fused‐silica capillary with UV detection. An acidic BGE was used to separate 1–84 PTH (full length), 7–84 PTH, and 1–34 PTH. Acetonitrile was added to the BGE to reduce peptide adsorption onto the capillary wall and transient isotachophoresis was used as analyte preconcentration method. The method was then transferred to a sheathless CE‐ESI‐MS instrument. When using a fused silica capillary, CE‐MS was limited to μg/mL levels. The use of a neutral coating combined with FASI or EKS allowed a significant increase in sensitivity. Under these conditions, 1–84 PTH, 7–84 PTH, and 1–34 PTH were detected at concentrations in the low ng/mL (FASI) or pg/mL (EKS) range.  相似文献   

2.
A highly sensitive and selective on‐line two‐dimensional reversed‐phase liquid chromatography/electrospray ionization–tandem mass spectrometry (2D‐LC‐ESI/MS/MS) method was developed and validated to determine rifaximin in rat serum by direct injection. The 2D‐LC‐ESI/MS/MS system consisted of a restricted access media column for trapping proteins as the first dimension and a Waters C18 column as second dimension using 0.1% aqueous acetic acid:acetonitrile as mobile phase in a gradient elution mode. Rifampacin was used as an internal standard. The linear dynamic range was 0.5–10 ng/mL (r2 > 0.998). Acceptable precision and accuracy were obtained over the calibration range. The assay was successfully used in analysis of rat serum to support pharmacokinetic studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
Benzofurazan derivatization reagents, 4‐[2‐(N,N‐dimethylamino)ethylaminosulfonyl]‐7‐(2‐aminopentylamino)‐2,1,3‐benzoxadiazole (DAABD‐AP) and 4‐[2‐(N,N‐dimethylamino) ethylaminosulfonyl]‐7‐(2‐aminobutylamino)‐2,1,3‐benzoxadiazole (DAABD‐AB), for short‐chain carboxylic acids in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) were synthesized. These reagents reacted with short chain carboxylic acids in the presence of the condensation reagents at 60°C for 60 min. The generated derivatives were separated on the reversed‐phase column and detected by ESI‐MS/MS with the detection limits of 0.1–0.12 pmol on column. Upon collision‐induced dissociation, a single and intense product ion at m/z 151 was observed. These results indicated that DAABD‐AP and DAABD‐AB are suitable as the derivatization reagents in LC/ESI‐MS/MS analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
Eflornithine (α‐difluoromethylornithine) has been used to treat second‐stage (or meningoencephalitic‐stage) human African trypanosomiasis and currently is under clinical development for cancer prevention. In this study, a new ultraperformance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS)‐based assay was developed and validated for the quantification of eflornithine in rat brain. To improve chromatographic retention and MS detection, eflornithine was derivatized with 6‐aminoquinolyl‐N‐hydroxysuccinimidyl carbamate for 5 min at room temperature prior to injection. Derivatized eflornithine was separated on a reverse‐phase C18 UPLC column with a 6‐min gradient; elution occurred at approximately 1.5 min. Prior to derivatization, eflornithine was reproducibly extracted from rat brain homogenate by methanol protein precipitation (~70% recovery). Derivatized eflornithine was stable in the autosampler (6 °C) for at least 24 h. This new assay had acceptable intra‐ and interday accuracy and precision over a wide dynamic range (5000‐fold) and excellent sensitivity with a lower limit of quantification of 0.1 µm (18 ng/mL) using only 10 μL of rat brain homogenate. The validated eflornithine assay was applied successfully to determine eflornithine distribution in different regions of rat brain in an in situ rat brain perfusion study. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
The derivatization reagents for carboxylic acids, N‐(Pyridin‐3‐yl)hydrazinecarbothioamide, N‐[4‐(dimethylamino)phenyl]hydrazinecarbothioamide, 1‐(2‐aminoethyl)‐3‐(pyridin‐3‐yl)thiourea, 1‐(2‐aminoethyl)‐3‐[4‐(dimethylamino)phenyl]thiourea and 4‐(2‐aminoethyl)‐N‐phenylpiperazine‐1‐carbothioamide were synthesized. These reagents reacted with carboxylic acids at 60°C for 45 min in the presence of the condensation reagents. The generated derivatives were favorably separated on the reversed‐phase column and sensitively detected by electrospray ionization tandem mass spectrometry. These reagents enhanced the electrospray ionization response of the analyte and generated a particular product ion efficiently by collision‐induced dissociation, and thus they were suitable for MS/MS detection. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
The major metabolite of duloxetine is a glucuronide conjugate of 4‐hydroxy duloxetine (4‐HD). However, interestingly, there have been no reports determining concentrations of 4‐HD and no fully validated method has been established for measuring duloxetine and 4‐HD in rat plasma. We developed a method for the simultaneous quantification of duloxetine and its metabolite in rat plasma using high‐performance liquid chromatography tandem mass spectrometry. Duloxetine and 4‐HD were analyzed on a reverse‐phase C18 analytical column after protein precipitation of the plasma sample with methanol, using carbamazepine as an internal standard. The isocratic mobile phase of 5 mm ammonium acetate–methanol (4:6, v/v) was eluted at 0.4 mL/min. Quantification was performed on a triple‐quadrupole mass spectrometer using electrospray ionization, and the ion transition monitored in selective reaction monitoring mode. The coefficient of variation for assay precision was <18.0%, and the accuracy was 84.0–118.0%. This method was successfully used to measure the concentrations of duloxetine and its metabolite in plasma following the oral administration of a single 40 mg/kg dose in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
A rapid, sensitive, and reliable ultra‐performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6‐aminoquinolyl‐carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C18 column with Acetonitrile–acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5–1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples.  相似文献   

8.
A sensitive, specific and accurate HPLC method for the quantification of rivastigmine (RSM) in rat urine was developed and validated. The method involves the simple liquid–liquid extraction of RSM and pyridostigmine as an internal standard (IS) from rat urine with tertiary methyl butyl ether. The chromatographic separation of RSM and IS was achieved with 20 mm ammonium acetate buffer (pH 6.5) and acetonitrile (65:35, v/v) delivered at flow‐rate of 1 mL/min on a Kromasil KR‐100. The method was in linear range from 50 to 5000 ng/mL. The validation was done as per FDA guidelines and the results met the acceptance criteria. The method was successfully applied for the quantification of RSM in rat urine. Besides method validation, we have identified two metabolites of RSM in urine. Both the metabolites were characterized by HPLC‐PDA and LC‐MS/MS and it was found that one metabolite is novel. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
A simple and practical derivatization procedure for increasing the detectability and enantiomeric separation of chiral carboxylic acids in LC/ESI‐MS/MS has been developed. (S)‐Anabasine (ANA) was used as the derivatization reagent and rapidly reacted with carboxylic acids [3‐hydroxypalmitic acid (3‐OH‐PA), 2‐(β‐carboxyethyl)‐6‐hydroxy‐2,7,8‐trimethylchroman (γ‐CEHC), and etodolac] in the presence of 4‐(4,6‐dimethoxy‐1,3,5‐triazin‐2‐yl)‐4‐methylmorpholium chloride. The resulting ANA‐derivatives were highly responsive in ESI‐MS operating in the positive‐ion mode and gave characteristic product ions during MS/MS, which enabled sensitive detection using selected reaction monitoring; the detection responses of the ANA‐derivatives were increased by 20–160‐fold over those of the intact carboxylic acids and the limits of detection were in the low femtomole range (1.8–11 fmol on the column). The ANA‐derivatization was also effective for the enatiomeric separation of the chiral carboxylic acids; the resolution was 1.92, 1.75, and 2.03 for 3‐OH‐PA, γ‐CHEC, and etodolac, respectively. The derivatization procedure was successfully applied to a biological sample analysis; the derivatization followed by LC/ESI‐MS/MS enabled the separation and detection of trace amounts of 3‐OH‐PA in neonatal dried blood spot and γ‐CEHC in human saliva with a simple pretreatment and small sample volume.  相似文献   

10.
A sensitive and efficient liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of piperaquine (PQ) and its N ‐oxidated metabolite (PQ‐M) in plasma. A simple protein precipitation procedure was used for sample preparation. Adequate chromatographic retention was achieved on a C18 column under gradient elution with acetonitrile and 2 mm aqueous ammonium acetate containing 0.15% formic acid and 0.05% trifluoroacetic acid. A triple‐quadrupole mass spectrometer equipped with an electrospray source was set up in the positive ion mode and multiple reaction monitoring mode. The method was linear in the range of 2.0–400.0 ng/mL for PQ and 1.0–50.0 ng/mL for PQ‐M with suitable accuracy, precision and extraction recovery. The lower limits of detection (LLOD) were established at 0.4 and 0.2 ng/mL for PQ and PQ‐M, respectively, using 40 μL of plasma sample. The matrix effect was negligible under the current conditions. No effect was found for co‐administrated artemisinin drugs or hemolysis on the quantification of PQ and PQ‐M. Stability testing showed that two analytes remained stable under all relevant analytical conditions. The validated method was successfully applied to a pharmacokinetic study performed in rats after a single oral administration of PQ (60 mg/kg).  相似文献   

11.
A rapid, novel and reliable UHPLC‐MS/MS method was developed and validated for simultaneous determination of cyclophosphamide (CP) and its dechloroethylated metabolite, 2‐dechloroethylcyclosphamide (2‐DCECP) in human plasma. The plasma samples were conducted by protein precipitation with 3‐fold acetonitrile, containing 0.1% formic acid. Mass spectrometric detection was performed using electrospray positive ionization with multiple reaction monitoring mode, using tinidazole as internal standard (IS). Chromatographic separation was performed on an Agilent poroshell 120 SB‐C18 column (2.1 × 75 mm, 2.7 µm) using gradient elution of acetonitrile and 0.1% formic acid at a flow rate of 0.5 mL/min, the total run time was 2.5 min. The limit of quantification (LOQ) was 20 ng/mL for both CP and 2‐DCECP. Accuracies and precisions were <15% at LOQ and below 10% at quality control concentration levels. This UHPLC‐MS/MS method was successfully applied for the estimation of CP and 2‐DCECP in human plasma, which was also useful for clinical toxicology studies and therapeutic drug monitoring of CP. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
In this paper, an ultra high performance liquid chromatography tandem mass spectrometric (UPLC‐ESI‐MS/MS) method in positive ion mode was established to systematically identify and to compare the major aconitum alkaloids and their metabolites in rat plasma and urine after oral administration of Fuzi extract. A total twenty‐nine components including twenty‐five C19‐diterpenoid alkaloids and four C20‐diterpenoid alkaloids were identified in Fuzi extract. Thirteen of the parent components and five metabolites were detected in rat plasma and sixteen parent compounds and six metabolites in urine. These parent components found in rat plasma and urine were mainly C19‐diterpenoid alkaloids. All of the metabolites in vivo were demethylated metabolites (phase I metabolites), which suggested that demethylation was the major metabolic pathway of aconitum alkaloids in vivo. A comparison of the parent components in rat plasma and urine revealed that 3‐deoxyacontine was found in plasma but not in urine, while kalacolidine, senbusine and 16‐β‐hydroxycardiopetaline existed in urine but not in plasma, which indicated that most alkaloids components were disposed and excreted in prototype form. This research provides some important information for further metabolic investigations of Fuzi in vivo.  相似文献   

13.
Ilaprazole is a new proton pump inhibitor designed for the treatment of gastric ulcers, and limited data is available on the metabolism of the drug. In this article, the structural elucidation of urinary metabolites of ilaprazole in human was described by HPLC‐ESI‐MS/MS and stopped‐flow HPLC‐NMR experiments. Urinary samples were precipitated by sodium carbonate solution, and then extracted by liquid–liquid extraction after adding ammonium acetate buffer solution. The enriched sample was separated using a C18 reversed‐phase column with the mobile phase composed of acetonitrile and 0.05 mol/L ammonium acetate buffer solution in a gradient solution, and then directly coupled to ESI‐MS/MS detection in an on‐line mode or 1H‐NMR (500 MHz) spectroscopic detection in a stopped‐flow mode. As a result, four sulfide metabolites, ilaprazole sulfide (M1), 12‐hydroxy‐ilaprazole sulfide (M2), 11,12‐dihydroxy‐ilaprazole sulfide (M3) and ilaprazole sulfide A (M4), were identified by comparing their MS/MS and NMR data with those of the parent drug and available standard compounds. The main biotransformation reactions of ilaprazole were reduction and the aromatic hydroxylation of the parent drug and its relative metabolites. The result testified that HPLC‐ESI‐MS/MS and HPLC‐NMR could be widely applied in detection and identification of novel metabolites. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Tacrine, as a drug for treating Alzheimer's disease (AD), has low efficacy owing to its single function and serious side effects. However, tacrine‐6‐ferulic acid (T6FA), the dimer which added ferulic acid to tacrine, has been found to be a promising multifunctional drug candidate for AD and much more potent and selective on acetylcholinesterase (AChE) than tacrine. The aim of the present work was to develop and validate an LC‐MS/MS method with electrospray ionization for the quantification of T6FA in rat plasma using tacrine‐3‐ferulic acid (T3FA) as internal standard and to examine its application for pharmacokinetic study in rats. Following a single liquid–liquid extraction with ethyl acetate, chromatographic separation was achieved at 25 °C on a BDS Hypersil C18 column with a mobile phase composed of 1% formic acid and methonal (30:70, v/v) at a flow rate of 0.2 mL/min. Quantification was achieved by monitoring the selected ions at m/z 474.2 → 298.1 for T6FA and m/z 432.2 → 199.0 for T3FA. The method was validated to be rapid, specific, accurate and precise over the concentration range of 0.5–1000.0 ng/mL in rat samples. Furthermore, it was successfully applied for the pharmacokinetic measurement of T6FA with an oral administration at 40 mg/kg to rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
The derivatization regents for carboxylic acids, DAABD-AE (4-[2-(N,N-dimethylamino)ethylaminosulfonyl]7-(2-aminoethylamino)-2,1,3-benzoxadiazole), MePZBD-AE ([4-(4-N-methyl)piperazinosulfonyl]-7-(2-aminoethylamino)-2,1,3-benzoxadiazole) and APZBD-NHMe ([4-(4-N-aminoethyl)piperazinosulfonyl]-7-methylamino-2,1,3-benzoxadiazole) were developed for electrospray ionization-mass spectrometry (ESI-MS). The derivatization reaction with fatty acids was completed at 60 degrees C within 30 min. The derivatives of fatty acids were separated on a reversed-phase column and detected with ESI-MS. The detection limits attained for fatty acids were femtomol range and the calibration curves were linear over the range from 0.1 to 100 pmol (r2 > 0.992) for DAABD-AE and MePZBD-AE. DAABD-NHMe was applied to the analysis of fatty acids in rat plasma samples.  相似文献   

16.
Calcineurin inhibitor nephrotoxicity, especially for the widely used tacrolimus, has become a major concern in post‐transplant immunosuppression. Multiparametric amino acid metabolomics is useful for biomarker identification of tacrolimus nephrotoxicity, for which specific quantitative methods are highlighted as a premise. This article presents a targeted metabolomic assay to quantify 33 amino acids and biogenic amines in human urine by high‐performance liquid chromatography coupled with tandem mass spectrometry. Chromatographic separation was carried out on an Agilent Zorbax SB‐C18 column (3.0 × 150 mm, 5 μm) with addition of an ion‐pairing agent in the mobile phase, and MS/MS detection was achieved in both the positive and negative multiple reaction monitoring modes. Good correlation coefficients (r2 > 0.98) were obtained for most analytes. Intra‐ and inter‐day precision, stability, carryover and incurred sample reanalysis met with the acceptance criteria of the guidance of the US Food and Drug Administration. Analysis on urine from healthy volunteers and renal transplantation patients with tacrolimus nephrotoxicity confirmed symmetric dimethylarginine and serine as biomarkers for kidney injury, with AUC values of 0.95 and 0.81 in receiver operating characteristic analysis, respectively. Additionally, symmetric dimethylarginine exhibited a tight correlation with serum creatinine, and was therefore indicative of renal function. The targeted metabolomic assay was time and cost prohibitive for amino acid analysis in human urine, facilitating the biomarker identification of tacrolimus nephrotoxicity.  相似文献   

17.
This report describes the development and validation of a chromatography/tandem mass spectrometry method for the quantitative determination of pravastatin and its metabolite (3α‐hydroxy pravastatin) in plasma and urine of pregnant patients under treatment with pravastatin, as part of a clinical trial. The method includes a one‐step sample preparation by liquid–liquid extraction. The extraction recovery of the analytes ranged between 93.8 and 99.5% in plasma. The lower limits of quantitation of the analytes in plasma samples were 0.106 ng/mL for pravastatin and 0.105 ng/mL for 3α‐hydroxy pravastatin, while in urine samples they were 19.7 ng/mL for pravastatin and 2.00 ng/mL for 3α‐hydroxy pravastatin. The relative deviation of this method was <10% for intra‐ and interday assays in plasma and urine samples, and the accuracy ranged between 97.2 and 106% in plasma, and between 98.2 and 105% in urine. The method described in this report was successfully utilized for determining the pharmacokinetics of pravastatin in pregnant patients enrolled in a pilot clinical trial for prevention of preeclampsia. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
Isocoproporphyrin and its derivatives are commonly used as biomarkers of porphyria cutanea tarda, heavy metal toxicity and hexachlorobenzene (HCB) intoxication in humans and animals. However, most are isobaric with other porphyrins and reference materials are unavailable commercially. The structural characterisation of these porphyrins is important but very little data is available. We report here the separation and characterisation of isocoproporphyrin, deethylisocoproporphyrin, hydroxyisocoproporphyrin and ketoisocoproporphyrin, isolated in the faeces of rats fed with a diet containing HCB, by ultra high performance liquid chromatography‐exact mass tandem mass spectrometry (UHPLC‐MS/MS). Furthermore, we report the identification and characterisation of a previously unreported porphyrin metabolite, isocoproporphyrin sulfonic acid isolated in the rat faeces. The measured mass‐to‐charge ratio (m/z) of the precursor ion was m/z 735.2338, corresponding to a molecular formula of C36H39N4O11S with an error of 0.3 ppm from the calculated m/z 735.2336. The MS/MS data was consistent with an isocoproporphyrin sulfonic acid structure, derived from dehydroisocoproporphyrinogen by sulfonation of the vinyl group. The metabolite was present in a greater abundance than other isocoproporphyrin derivatives and may be a more useful biomarker for HCB intoxication. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
NMR spectra of mixtures of metabolites extracted from cells or tissues are extremely complex, reflecting the large number of compounds that are present over a wide range of concentrations. Although multidimensional NMR can greatly improve resolution as well as improve reliability of compound assignments, lower abundance metabolites often remain hidden. We have developed a carbonyl‐selective aminooxy probe that specifically reacts with free keto and aldehyde functions, but not carboxylates. By incorporating 15N in the aminooxy functional group, 15N‐edited NMR was used to select exclusively those metabolites that contain a free carbonyl function while all other metabolites are rejected. Here, we demonstrate that the chemical shifts of the aminooxy adducts of ketones and aldehydes are very different, which can be used to discriminate between aldoses and ketoses, for example. Utilizing the 2‐bond or 3‐bond 15N‐1H couplings, the 15N‐edited NMR analysis was optimized first with authentic standards and then applied to an extract of the lung adenocarcinoma cell line A549. More than 30 carbonyl‐containing compounds at NMR‐detectable levels, six of which we have assigned by reference to our database. As the aminooxy probe contains a permanently charged quaternary ammonium group, the adducts are also optimized for detection by mass spectrometry. Thus, this sample preparation technique provides a better link between the two structural determination tools, thereby paving the way to faster and more reliable identification of both known and unknown metabolites directly in crude biological extracts. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
The benefit–risk ratio of combined blocking by the direct renin inhibitor aliskiren and an angiotensin‐converting enzyme inhibitor (e.g. enalapril) on the renin–angiotensin–aldosterone system is discussed. No method was available for simultaneous determination of both drugs in urine. A novel sensitive method for simultaneous quantification in undiluted human urine was developed which enables systematic pharmacokinetic investigations, especially in poorly investigated populations like children. Matrix effects were clearly reduced by applying solid‐phase extraction followed by a chromatographic separation on XselectTM C18 CSH columns. Mobile phase consisted of methanol and water, both acidified with formic acid. Under gradient conditions and a flow rate of 0.4 mL/min the column effluent was monitored by tandem mass spectrometry with electrospray ionization. Calibration curves were constructed in the range of 9.4–9600 ng/mL regarding aliskiren, 11.6–12000 ng/mL for enalapril and 8.8–9000 ng/mL for enalaprilat. All curves were analyzed utilizing 1/x2‐weighted quadratic squared regression. Intra‐run and inter‐run precision were 3.2–5.8% and 6.1–10.3% for aliskiren, 2.4–6.1% and 3.9–7.9% for enalapril as well as 3.1–9.4% and 4.7–12.7% regarding enalaprilat. Selectivity, accuracy and stability results comply with current international bioanalysis guidelines. The fully validated method was successfully applied to a pharmacokinetic investigation in healthy volunteers. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号