首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
在金电极表面电沉积银为氧化还原探针,利用有机多孔材料(PTC-NH2)、纳米金(nano-Au)固载甲胎蛋白抗体(anti-AFP),制备出用于检测甲胎蛋白(AFP)的安培型免疫传感器。通过交流阻抗技术、循环伏安法研究了电极的电化学特性,考察了孵育时间、测试液pH值等实验条件对传感器性能的影响,并利用扫描电子显微镜(SEM)对电极的修饰过程进行了表征。该传感器对AFP有良好的电流响应,线性范围分别为1.0~20.0ng/mL和20.0~60.0 ng/mL,检测限为0.6 ng/mL。  相似文献   

2.
A sensitive and specific electrochemical immunosensor was developed with α‐fetoprotein (AFP) as the model analyte by using gold nanoparticle label for enzymatic catalytic amplification. A self‐assembled monolayer membrane of mercaptopropionic acid (MPA) was firstly formed on the electrode surface through gold‐sulfur interaction. Monoclonal mouse anti‐human AFP was covalently immobilized to serve as the capture antibody. In the presence of the target human AFP, gold nanoparticles coated with polyclonal rabbit anti‐human AFP were bound to the electrode via the formation of a sandwiched complex. With the introduction of goat anti‐rabbit IgG conjugated with alkaline phosphatase, the dentritical enzyme complex was formed through selective interaction of the secondary antibodies with the colloidal gold‐based primary antibody at the electrode, thus affording the possibility of signal amplification for AFP detection. Current response arising from the oxidation of enzymatic product was significantly amplified by the dentritical enzyme complex. The current signal was proportional to the concentration of AFP from 1.0 ng mL?1 to 500 ng mL?1 with a detection limit of 0.8 ng mL?1. This system could be extended to detect other target molecules with the corresponding antibody pairs.  相似文献   

3.
The electrochemical immunosensor for α‐fetoprotein (AFP) was fabricated based on the platform of gold nanoparticles (GNP)/graphene (Gr)‐prussian blue (PB). By electrodeposition, GNP were modified on the surface of the prepared Gr‐PB. The anti‐AFP‐1,1′‐ferrocenedicarboxylic acid (FcDA) as label was directly immobilized on the platform of GNP/Gr‐PB. And after the immunoreactions, the formed complex inhibited the electron transfer and decreased the catalytic current of FcDA toward the reduction of H2O2. And in the range of 10–3200 pg·mL?1, the decreased current is linear with the concentration of AFP, with a detection limit of 3 pg·mL?1. The developed immunoassay method showed good precision, high sensitivity, acceptable stability and reproducibility, and could be used for the detection of real samples with consistent results in comparison with those obtained by the enzyme linked immunosorbent assay (ELISA) method.  相似文献   

4.
In the present work, a newly functional nanoparticle has been prepared to immobilize the protein for the detection of α‐1‐fetoprotein (AFP). Prussian blue (PB) nanoparticle was initially synthesized under ultrasonic condition, then bovine serum albumin (BSA) was used to coat the PB nanoparticle to improve the stability of the PB nanoparticle as well as functionalize the surface of PB nanoparticle, and then gold colloids were loaded on the BSA‐coated PB nanoparticle to construct a core‐shell‐shell nanostructure via the conjunction of thiolate linkages or alkylamines of the BSA. Finally, a convenient, effective and sensitivity amperometric immunosensor for the detection of α‐1‐fetoprotein (AFP) was constructed by the employment of these functional core‐shell‐shell microspheres. The preparation of the nanoparticle (Au‐BSA‐PB NPs) was characterized by transmission electron microscopy (TEM), and the assembly of the biosensor was characterized with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The dynamic range of the resulted immunosensor for the detection of AFP is from 0.02 ng/mL to 200.0 ng/mL with a detection limit of 0.006 ng/mL (S/N=3). Moreover, this biosensor displays good selectivity, stability and reproducibility.  相似文献   

5.
Lu Zhou  Ruo Yuan  Yaqin Chai 《Electroanalysis》2007,19(11):1131-1138
A poly(vinylchloride) (PVC) membrane based potentiometric immunosensor for the direct detection of alpha‐fetoprotein (AFP) has been developed. First, Au colloid particle was chemisorbed upon amino groups of o‐phenylenediamine, which were dissolved in plasticized PVC membrane. Then alpha‐fetoprotein antibody (anti‐AFP) was immobilized upon the surface of the Au colloid particle to prepare a potentiometric AFP immunosensor. The Au colloid particle modified PVC membrane was characterized by digital photo and transmission electron microscope (TEM). The immunosensor exhibited fast potentiometric response (≤4 min) and showed specific response to AFP in the range of 4.9 to 158.5 ng/mL with a correlation coefficient of 0.9971 and a detection limit of 1.6 ng/mL. The factors influencing the performance of the immunosensor were also studied in detail. Moreover, the proposed method is economical and efficient as well as potentially attractive for clinical immunoassays.  相似文献   

6.
A novel and highly sensitive electrochemical immunosensor was developed for the detection of protein biomarker tumor necrosis factor‐alpha (TNF‐α) based on immobilization of TNF‐α‐antibody (anti‐TNF‐α) onto robust nanocomposite containing gold nanoparticles (AuNP), multiwalled carbon nanotubes (MWCNTs) and ionic liquid (1‐buthyl‐3‐methylimidazolium bis (trifluoromethyl sulfonyl)imide). Functionalized MWCNT‐gold nanoparticle was produced by one‐step synthesis based on the direct redox reaction. The electrochemical properties of nanocomposite were characterized by electrochemical impedance spectroscopy and cyclic voltammetry. The anti‐TNF‐α was immobilized or entrapped in the nanocomposite and used in a sandwich type complex immunoassay with anti‐TNF‐α labeled with horseradish peroxidase as secondary antibody. Under optimum conditions, the immunosensor could detect TNF‐α in a linear range from 6.0 to 100 pg mL?1 with a low detection limit of 2.0 pg mL?1. The simple fabrication method, high sensitivity, good reproducibility, stability, as well as acceptable accuracy for TNF‐α detection in human serum samples are the main advantages of this immunosensor, which might have broad applications in protein diagnostics and bioassay.  相似文献   

7.
《Electroanalysis》2018,30(1):31-37
The electrochemical detection of alpha‐feto protein based on novel gold nanoparticles‐ poly(propylene imine) dendrimer platform is reported. The platform was prepared by co‐electrodeposition of gold nanoparticles and generation 3 poly (propylene imine) dendrimer on a glassy carbon electrode. Each modifying step was characterised by cyclic voltammetry and electrochemical impedance spectroscopy. The electrochemical measurements showed that the platform was stable, conducting and exhibited reversible electrochemistry. Results obtained from the electrochemical impedance spectroscopy interrogation in [Fe(CN)63−/4−] redox probe showed a marked reduction in charge transfer resistance (Rct) after each modification step. The immunosensor was prepared by immobilisation of a probe anti‐alpha feto protein (AFP) on the platform for 3 hrs at 35 °C followed by blocking the surface with bovine serum albumin to minimise non‐specific binding. The prepared immunosensor was used to detect AFP over a wide concentration range from 0.005 to 500 ng/mL and detection limits of 0.0022 and 0.00185 ng/mL were obtained for SWV and EIS measurements respectively. The immunosensor gave good stability over a period of fourteen days when stored at 4 °C.  相似文献   

8.
Calmodulin (CaM) is an important intracellular calcium‐binding protein. It plays a critical role in a variety of biological and biochemical processes. In this paper, a new electrochemical immunosensing protocol for sensitive detection of CaM was developed by using gold‐silver‐graphene (AuAgGP) hybrid nanomaterials as protein immobilization matrices and gold nanorods (GNRs) as enhanced electrochemical labels. Electrode was first modified with thionine‐chitosan film to provide an immobilization support for gold‐silver‐graphene hybrid nanomaterials. The hybrid materials formed an effective matrix for binding of CaM with high density and improved the electrochemical responses as well. Gold nanorods were prepared for the fabrication of enhanced labels (HRP‐Ab2‐GNRs), which provided a large capacity for HRP‐Ab2 immobilization and a facile pathway for electron transfer. With two‐step immunoassay format, the HRP‐Ab2‐GNRs labels were introduced onto the electrode surface, and produced electrochemical responses by catalytic reaction of HRP toward enzyme substrate of hydrogen peroxide (H2O2) in the presence of thionine. The proposed immunosensor showed an excellent analytical performance for the detection of CaM ranging from 50 pg mL?1 to 200 ng mL?1 with a detection limit of 18 pg mL?1. The immunosensor has also been successfully applied to the CaM analysis in two cancer cells (HepG2 and MCF‐7) with high sensitivity, which has shown great potency for improving clinic diagnosis and treatment for cancer study.  相似文献   

9.
制备了易于磁性分离、硫堇(Thi)包覆的四氧化三铁(Fe3O4)纳米复合物。通过静电吸附作用,将萘酚(Nafion)、Thi包覆的Fe3O4复合纳米粒子层层修饰到玻碳电极表面,再利用Thi分子中的氨基吸附纳米金,最后固载甲胎蛋白抗体,从而制得灵敏度高、稳定性好的无试剂电流型甲胎蛋白免疫传感器。实验通过透射电子显微镜(TEM)对该复合纳米粒子进行表征,并用循环伏安法考察了电极的电化学特性。结果表明,Fe3O4/Thi复合纳米粒子修饰的电极在实验过程中呈现出良好的氧化还原活性,其检测范围为0.05~20μg/L,检出限为0.03μg/L。  相似文献   

10.
A novel amperometric immunosensor for the determination of alpha-fetoprotein (AFP) was constructed using films of multi-wall carbon nanotubes/DNA/thionine/gold nanoparticles (nano-Au). Firstly, multi-wall carbon nanotubes (MWCNT) dispersed in poly(diallydimethlammonium chloride) (PDDA) were immobilized on the nano-Au film which was electrochemically deposited on the surface of glassy carbon electrode. Then a negatively charged DNA film was absorbed on the positively charged PDDA. Subsequently, thionine was attached to the electrode via the electrostatic interaction between thionine and the DNA. Finally, the nano-Au was retained on the thionine film for immobilization of AFP antibody (anti-AFP). The modification process was characterized by cyclic voltammetry (CV) and scanning electron microscope (SEM). The factors possibly influenced the performance of the proposed immunosensors were studied in detail. Under optimal conditions, the proposed immunosensor exhibited good electrochemical behavior to AFP in a two concentration ranges: 0.01–10.0 and 10.0–200.0 ng/mL with a relatively low detection limit of 0.04 ng/mL at three times the background noise. Moreover, the selectivity, repeatability and stability of the proposed immunosensor were acceptable.  相似文献   

11.
An electrochemical biosensor was developed for the determination of Escherichia coli (E. coli) in water. For this purpose, silver‐gold core‐shell (Ag@Au) bioconjugates and anti‐E. coli modified PS‐microwells were designed in a sandwich‐type format in order to obtain higher sensitivity and selectivity. Ag@Au bimetallic nanoparticles were synthesized by co‐reduction method. The core‐shell formation was analyzed by using UV‐Vis spectroscopy and transmission electron microscopy. Biotin labeled anti‐E. coli antibodies were coupled with Ag@Au nanoparticles to form bioconjugates. The electrochemical immunosensor was prepared by immobilizing anti‐E. coli on polystyrene (PS)‐microwells via chemical bonding. These modified microwells were identified with X‐ray photoelectron spectroscopy and surface enhanced Raman spectroscopy. E. coli was sandwiched between Ag@Au bioconjugates and anti‐E. coli on PS‐microwells at different concentrations. The relationship between the E. coli concentration and stripping current of gold ions (Au3+) were investigated by square wave anodic stripping voltammetry at pencil graphite electrode. The proposed method can provide some advantages such as lower detection limit and shorter detection time. The electrochemical response for the immunosensor was linear with the concentration of the E. coli in the range of 101 and 105 cfu/mL with a limit of detection 3 cfu/mL. The procedure maintains good sensitivity and repeatability and also offers utility in the fields of environmental monitoring and clinical diagnosis.  相似文献   

12.
Various sensor‐based immunoassay methods have been extensively developed for the detection of cancer antigen 15‐3 (CA 15‐3), but most often exhibit low detection signals and low detection sensitivity, and are unsuitable for routine use. The aim of this work is to develop a simple and sensitive electrochemical immunoassay for CA 15‐3 in human serum by using nanogold and DNA‐modified immunosensors. Prussian blue (PB), as a good mediator, was initially electrodeposited on a gold electrode surface, then double‐layer nanogold particles and double‐strand DNA (dsDNA) with the sandwich‐type architecture were constructed on the PB‐modified surface in turn, and then anti‐CA 15‐3 antibodies were adsorbed onto the surface of nanogold particles. The double‐layer nanogold particles provided a good microenvironment for the immobilization of biomolecules. The presence of dsDNA enhanced the surface coverage of protein, and improved the sensitivity of the immunosensor. The performance and factors influencing the performance of the immunosensor were evaluated. Under optimal conditions, the proposed immunosensor exhibited a wide linear range from 1.0 to 240 ng/mL with a relatively low detection limit of 0.6 ng/mL (S/N=3) towards CA 15‐3. The stability, reproducibility and precision of the as‐prepared immunosensor were acceptable. 57 serum specimens were assayed by the developed immunosensor and standard enzyme‐linked immunosorbent assay (ELISA), respectively, and the results obtained were almost consistent. More importantly, the proposed methodology could be further developed for the immobilization of other proteins and biocompounds.  相似文献   

13.
A approach was successfully employed for constructing a solid‐state electrochemiluminescence (ECL) immunosensor by layer‐by‐layer self‐assembly of multiwall carbon nanotubes (MWCNTs)‐Nafion composite film, Ru(bpy)32+/nano‐Pt aggregates (Ru‐PtNPs) and Pt nanoparticles (PtNPs). The influence of Pt nanoparticles on the ECL intensity was quantitatively evaluated by calculating the electroactive surface area of different electrodes with or without PtNPs to immobilize Ru(bpy)32+. The principle of ECL detection for target α‐fetoprotein antigen (AFP) was based on the increment of resistance after immunoreaction, which led to a decrease in ECL intensity. The linear response range was 0.01–10 ng mL?1 with the detection limit of 3.3 pg mL?1. The immunosensor exhibited advantages of simple preparation and operation, high sensitivity and good selectivity.  相似文献   

14.
In this work, a novel sandwich‐type electrochemical immunosensor with electroactive nickel hexacyanoferrate nanoparticles (NiHCFNPs) as matrix was constructed for α‐fetoprotein (AFP) detection in a signal‐off manner by using FeS2?AuNPs nanocomposite catalyzed insoluble precipitation to significantly inhibit the electrochemical signal. Initially, the NiHCFNPs with excellent electrochemical property was modified on the electrodeposited nano‐Au electrode to obtain a strong initial electrochemical signal. Subsequently, another nano‐Au layer was formed for immobilization of capture antibody (Ab1). In the presence of target AFP, the prepared FeS2?AuNPs‐Ab2 bioconjugate could be specifically recognized and immobilized on electrode through the sandwich‐type immunoreaction. The FeS2 with large specific surface areas were used as scaffolds to load abundant mimicking enzyme AuNPs. With the help of hydrogen peroxide (H2O2), FeS2?AuNPs with peroxidase‐like activity accelerated the 4‐chloro‐1‐naphthol (4‐CN) oxidation with generation of insoluble precipitation on electrode, which would greatly hinder the electron transfer and thus caused the decrease of electrochemical signal for quantitative determination of AFP. This approach achieved a wide dynamic linear range from 0.0001 to 100 ng mL?1 with an ultralow limit detection of 0.028 pg mL?1. Especially, the proposed AFP immunosensor can be applied to detect human serum samples with satisfactory results, indicating a potential application in clinical monitoring of tumor biomarkers.  相似文献   

15.
《Analytical letters》2012,45(7):735-745
A simple and disposable electrochemical immunosensor for detection of 68 kDa alpha-fetoprotein (AFP) was fabricated based on films of silk fibroin protein membrane (SFPM)/Prussian blue (PB)/deposition of gold nanoparticles (DpAu). First, DpAu and PB were electrochemically deposited successively on the surface of indium tin oxide (ITO) electrode. Then, SFPM with excellent biocompatibility was modified on the surface of PB/DpAu/ITO. The SFPM could form a stable matrix on the electrode surface for the deposition of immunoactive agents. More importantly, the SFPM could prevent the possible leakage of electron mediator and enhance the stability of immunosensor. Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used to characterize the assembly process of the modified electrode. The linear range of the proposed immunosensor extended from 1.0 to 200.0 ng/mL for detection of AFP with a detection limit of 0.6 ng/mL. Moreover, the CV test demonstrated the immunosensor exhibited acceptable reproducibility and stability. This composite membrane could be applied for the detection of different biomarkers, diagnosis, and monitoring of carcinoma.

[Supplementary materials are available for this article. Go to the publisher's online edition of Analytical Letters for the following free supplemental resources: additional figures.]  相似文献   

16.
A new dual‐amplification strategy of electrochemical signaling from antigen–antibody interactions was proposed via backfilling gold nanoparticles on (3‐mercaptopropyl) trimethoxysilane sol‐gel (MPTS) functionalized interface. The MPTS was employed not only as a building block for the electrode surface modification but also as a matrix for ligand functionalization with first amplification. The second signal amplification strategy introduced in this study was based on the backfilling immobilization of nanogold particles to the immunosensor surface. Several coupling techniques, such as with nanogold but not MPTS or with MPTS but not nanogold, were investigated for the determination of carcinoembryonic antigen (CEA) as a model, and a very good result was obtained with nanogold and MPTS coupling immunosensor. With the noncompetitive format, the formation of the antigen–antibody complex by a simple one‐step immunoreaction between the immobilized anti‐CEA and CEA in sample solution introduced membrane potential change before and after the antigen–antibody interaction. Under optimal conditions, the proposed immunosensor exhibited a good electrochemical behavior to CEA in a dynamic concentration range of 4.4 to 85.7 ng/mL with a detection limit of 1.2 ng/mL (at 3 δ). Moreover, the precision, reproducibility and stability of the as‐prepared immunosensor were acceptable. Importantly, the proposed methodology would be valuable for diagnosis and monitoring of carcinoma and its metastasis.  相似文献   

17.
A novel reagentless amperometric immunosensor for the determination of alpha‐fetoprotein (AFP) was prepared by immobilizing TiO2 colloids on Prussian blue (PB) modified platinum electrode, which yielded a positively charged interface with strong adsorption to deposit gold nanoparticles for immobilization of alpha‐fetoprotein antibody (anti‐AFP). The factors influencing the performance of the proposed immunosensors were studied in detail. Under the optimized conditions, cyclic voltammograms determination of AFP showed a specific response in two concentration ranges from 3.0 to 30.0 ng/mL and from 30.0 to 300.0 ng/mL with a detection limit of 1.0 ng/mL at a signal‐to‐noise ratio of 3. The proposed immunosensor exhibited high selectivity, good reproducibility, long‐term stability (>2 months) and good repeatability.  相似文献   

18.
A simple, highly sensitive and label‐free electrochemical impedance spectroscopy (EIS) immunosensor was developed using Nafion and gold nanoparticles (nano‐Au/Nafion) composites for the determination of 1‐pyrenebutyric acid (PBA). Under the optimal conditions, the amount of immobilized antibody was significantly improved on the nano‐Au/Nafion electrode due to the synergistic effect and biocompatibility of Nafion film and gold nanoparticles composites. The results showed that the sensitivity and stability of nano‐Au/Nafion composite electrode for PBA detection were much better than those of nano‐Au modified glassy carbon electrode (nano‐Au/GCE). The plot of increased electron transfer resistances (Rets) against the logarithm of PBA concentration is linear over the range from 0.1 to 150 ng·mL?1 with the detection limit of 0.03 ng·mL?1. The selectivity and accuracy of the proposed EIS immunosensor were evaluated with satisfactory results.  相似文献   

19.
Gold nanoparticles of different morphologies have been synthesized on a silica‐based organic‐inorganic hybrid material for catalytic applications. The gold nanoparticles formations proceed through in situ chemical reduction of the AuCl4? anions previously adsorbed on 3‐(1‐imidazolyl)propyl‐silsesquioxane, which plays the role of substrate and stabilizer. Two distinct reducing agents, sodium citrate and sodium borohydride, were employed to generate gold nanoparticles of different sizes. UV‐vis diffuse reflectance as well as transmission electron microscopy were employed to evaluate the particle’s morphology. Modified carbon paste electrodes were prepared from these materials and their electrochemical behavior investigated using potassium ferrocyanide and 4‐nitrophenol as redox model compounds. Both AuNPs‐modified electrodes decreased the overpotential of 4‐nitrophenol reduction by around 90 mV compared to the unmodified electrode as evidenced by cyclic voltammetry experiment. However, the smaller diameter particles (borohydride‐reduced) produced more significant catalytic effect as a consequence of their large surface area. Regarding the sensing parameters, the sensitivity is higher for the borohydride‐reduced AuNPs while the values of limit of detection are of the same order of magnitude. Thus, the detection limit and sensitivity are 70.0±0.6 nM and 187 µA/mM for the citrate‐reduced AuNPs; and 75.0±2.2 nM and 238 µA/mM for the borohydride‐reduced AuNPs.  相似文献   

20.
Xiao‐Hong Fu 《Electroanalysis》2007,19(17):1831-1839
A new electrochemical immunosensor for the detection of carbohydrate antigen‐125 (CA125), a carcinoma antigen, was developed by immobilization CA125 antibody (anti‐CA125) on gold hollow microspheres and porous polythionine (PTH) modified glassy carbon electrodes (GCE). The gold hollow microspheres provided a biocompatible microenvironment for proteins, and greatly amplified the coverage of anti‐CA125 molecules on the electrode surface. The performance and factors influencing the immunosensor were investigated in detail. The detection is based on the current change before and after the antigen‐antibody interaction. Under optimal conditions, the amperometric changes were proportional to CA125 concentration ranging from 4.5 to 36.5 U/mL with a detection limit of 1.3 U/mL (at 3σ). The CA125 immunosensor exhibited good precision, high sensitivity, acceptable stability, accuracy and reproducibility. The as‐prepared immunosensors were used to analyze CA125 in human serum specimens. Analytical results suggest that the developed immunoassay has a promising alternative approach for detecting CA125 in the clinical diagnosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号