首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
We report a rapid and simple method for sensing estradiol by electro‐oxidation on a multi‐walled carbon nanotube (MWCNT) and gold nanoparticle (AuNP) modified glassy carbon electrode (GCE). Compared with a bare GCE, AuNP/GCE and MWCNT/GCE, the composite modified GCE shows an enhanced response to estradiol in 0.1 M phosphate buffer solution. Experimental parameters, including pH and accumulation time for estradiol determination were optimised at AuNP/MWCNT/GCE. A pH of 7.0 was found to be optimum pH with an accumulation time of 5 minutes. Estradiol was determined by linear sweep voltammetry over a dynamic range up to 20 %mol L?1 and the limit of detection was estimated to be 7.0×10?8 mol L?1. The sensor was successfully applied to estradiol determination in tap water and waste water.  相似文献   

2.
In this study, interaction of tetracycline (TC) and DNA in the Britton? Robinson buffer solution (BR) was studied by cyclic voltammetry. The experimental results reveal that TC can bind strongly to DNA and the association constant and binding number between TC and DNA was obtained. Then DNA was immobilized on a glassy carbon electrode by UV‐irradiation. Through this process, water‐soluble DNA was converted into insoluble materials, and a stable DNA film was formed on the electrode. The electrochemical oxidation behavior of TC was studied at UV‐irradiated DNA film modified glassy carbon electrode (UV‐DNA‐GCE). The response of modified electrode was optimized with respect to pH, accumulation time, ionic strength, drug concentration and other variables. TC at the surface of modified electrode showed a linear dynamic range of 0.30–90.00 µM and a detection limit of 0.27 µM. To demonstrate the applicability of the modified electrode, it was used for the analysis of real samples such as pharmaceutical formulations and milk.  相似文献   

3.
制备了对氨基苯磺酸/石墨烯复合膜修饰电极,研究了汞在修饰电极上的电化学行为。 在0.1 mol/L、pH=4.0的磷酸盐缓冲液中,以此修饰电极为工作电极,在-1.2 V搅拌富集5 min,用差分脉冲伏安法测定0.31 V处的溶出峰电流。 结果表明,该电极显著提高了汞离子的电化学响应信号。 在优化条件下,峰电流与Hg2+的浓度在1.0×10-6~5.0×10-4 mol/L范围内呈良好的线性关系,相关系数为0.995。 方法的检出限为5.0×10-7 mol/L。 将该法用于水样中痕量汞的测定,回收率为92.2%~105.2%。  相似文献   

4.
In this work, low‐cost and environmentally friendly natural zeolite exchanged with Mn2+ cations was used for the first time to modify the glassy carbon electrode with the aim to obtain a fast and simple sensor for voltammetric determination of paracetamol (PAR). The Mn‐zeolite/graphite modified glassy carbon electrode (MnZG?GCE) was prepared by evaporation of solvent from dispersion of the zeolite/graphite mixture with the polymer in acetone. The electrochemical characteristics of MnZG?GCE were conducted by electrochemical impedance spectroscopy and cyclic voltammetry. Compared with graphite modified GCE (G?GCE), MnZG?GCE exhibited better electrochemical parameters, which confirms the superiority of applying zeolite in the proposed sensor. The optimization of the pH‐value of supporting electrolyte and instrumental parameters were carried out. The peak current was proportional to the concentration of PAR in a phosphate buffer saline of pH 6.0 in the range from 0.029 to 0.69 mg L?1 (R=0.9997) with limit of detection of 8.8 μg L?1. Finally, the proposed electrode was successfully applied to determine the paracetamol in pharmaceutical formulation and certified reference materials. The satisfactory recoveries, which ranged from 89.2 to 102.7 %, were obtained for all studied samples. It confirmed the attractiveness of relatively inexpensive, easy to fabricate and non‐toxic MnZG?GCE in determination of PAR in complicated matrixes.  相似文献   

5.
The electrochemical reduction of three common insecticides such as cypermethrin (CYP), deltamethrin (DEL) and fenvalerate (FEN) was investigated at glassy carbon electrode (GCE), multiwalled carbon nanotubes modified GCE (MWCNT‐GCE), polyaniline (herein called as modifier M1) and polypyrrole (herein called as modifier M2) deposited MWCNT/GCE using cyclic voltammetry. Influences of pH, scan rate, and concentration were studied. The surface morphology of the modified film was characterized by scanning electron microscopy (SEM) and X‐ray diffraction analysis (XRD). A systematic study of the experimental parameters that affect differential pulse stripping voltammetry (DPSV) was carried out and the optimized experimental conditions were arrived at. The calibration plots were linear over the insecticide's concentration range 0.1–100 mg L?1 and 0.05–100 mg L?1 for all the three insecticides at MWCNT‐GCE and MWCNT(M1)‐GCE respectively. The MWCNT(M2)‐GCE performed well among the three electrode systems and the determination range obtained was 0.01–100 mg L?1 for CYP, DEL and FEN. The limit of detection (LOD) was 0.35 μg L?1, 0.9 μg L?1 and 0.1 μg L?1 for CYP, DEL and FEN respectively on MWCNT(M2)‐GCE modified system. Suitability of this method for the trace determination of insecticide in spiked soil sample was also determined.  相似文献   

6.
A sensitive electrochemical method was developed for the determination of bisphenol A (BPA) at a glassy carbon electrode (GCE) modified with a multiwalled carbon nanotubes (MWCNTs)‐gold nanoparticles (GNPs) hybrid film, which was prepared based on the electrostatic interaction between positively charged cetyltrimethylammonium bromide (CTAB) and negatively charged MWCNTs and GNPs. The MWCNT‐GNPs/GCE exhibited an enhanced electroactivity for BPA oxidation versus unmodified GCE and MWCNTs/GCE. The experimental parameters, including the amounts of modified MWCNTs and GNPs, the pH of the supporting electrolyte, scan rate and accumulation time, were examined and optimized. Under the optimal conditions, the differential pulse voltammetric anodic peak current of BPA was linear with the BPA concentration from 2.0×10?8 to 2×10?5 mol L?1, with a limit of detection of 7.5 nmol L?1. The proposed procedure was applied to determine BPA leached from real plastic samples with satisfactory results.  相似文献   

7.
《Electroanalysis》2002,14(23):1615-1620
Electrochemically modified glassy carbon electrode (GCE) was used to study the electrochemical oxidation and detection of denatured single‐stranded (ss) DNA by means of adsorptive stripping voltammetry. The modification of GCE, by electrochemical oxidation at +1.75 V (vs.SCE) for 10 min and cyclic sweep between +0.3 V and ?1.3 V for 20 cycles in pH 5.0 phosphate buffer, results in 100‐fold improvement in sensitivity for ssDNA detection. We speculated that the modified GCE has a high affinity to single‐stranded DNA through hydrogen bond (specific static adsorption). Single‐stranded DNA can accumulate at the GCE surface at open circuit and produce a well‐defined oxidation peak corresponding to the guanine residues at about +0.80 V in pH 5.0 phosphate buffer, while the native DNA gives no signal under the same condition. The peak currents are proportional to the ssDNA concentration in the range of 0–18.0 μg mL?1. The detection limit of denatured ssDNA is ca. 0.2 μg mL?1 when the accumulation time is 8 min at open circuit. The accumulation mechanism of ssDNA on the modified GCE was discussed.  相似文献   

8.
The present study was aimed at investigating the use of a mixture multiwall carbon nanotube (MWCNT) and thionine (Th) dye in designing of a thionine‐based electrochemical biosensor containing catalase (Ct) enzyme (MWCNT‐Nafion‐Th/Ct) onto a glassy carbon electrode (GCE). The effects of pH, MWCNT concentration and thionine concentration on electrochemical response were explored for optimum analytical performance. The modified electrode exhibited a pair of well‐defined, quasi‐reversible peaks at formal potential (Eo′) = ‐0.218 ± 0.017 V vs. Ag/AgCl corresponding to the Thox/Thred redox couples in the presence of MWCNT, Nafion, and Ct. The electrochemical parameters, including charge‐transfer coefficient (0.36), and apparent heterogeneous electron transfer rate constant (4.28 ± 0.26 s?1) were determined. Using differential pulse voltammetry, the prepared enzyme electrode exhibited a linear response to hydrogen peroxide (H2O2) in the range of 10.0‐100.0 μM with a detection limit 8.7 μM and a sensitivity of 6051.0 μA mM?1 cm?2.  相似文献   

9.
We report the adsorptive voltammetric determination of nifedipine on multiwalled carbon nanotubes (MWCNT)‐modified glassy carbon electrode (GCE). Nifedipine was adsorbed on the MWCNT and then reduced using linear sweep and cyclic voltammetry (LSV and CV). Parameters such as pH and accumulation time were tested. The MWCNT‐modified GCE showed enhanced currents and good signal‐to‐noise characteristics in comparison with the bare GCE. Consecutive measurements with the modified electrode were highly repeatable and reproducible. The MWCNT/GCE was used for the determination of nifedipine and is recommended for quantitation in dissolution test studies. In this study we have tested normal and extended‐release pharmaceutical formulations of nifedipine using USP apparatus 2 and tracking the released drug in solution by the proposed voltammetric method. The main advantage of the voltammetric determination is the feasibility to detect the drug in‐situ avoiding tedious intermediate steps such as filtration, collection and replenishment of sample solutions. This work seeks to demonstrate the feasibility of applying voltammetric techniques in dissolution test studies.  相似文献   

10.
《Electroanalysis》2017,29(7):1741-1748
The determination of lead ions by inhibition of choline oxidase enzyme has been evaluated for the first time using an amperometric choline biosensor. Choline oxidase (ChOx) was immobilized on a glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT) through cross‐linking with glutaraldehyde. In the presence of ChOx, choline was enzymatically oxidized into betaine at –0.3 V versus Ag/AgCl reference electrode, lead ion inhibition of enzyme activity causing a decrease in the choline oxidation current. The experimental conditions were optimised regarding applied potential, buffer pH, enzyme and substrate concentration and incubation time. Under the best conditions for measurement of the lowest concentrations of lead ions, the ChOx/MWCNT/GCE gave a linear response from 0.1 to 1.0 nM Pb2+ and a detection limit of 0.04 nM. The inhibition of ChOx by lead ions was also studied by electrochemical impedance spectroscopy, but had a narrower linear response range and low sensitivity. The inhibition biosensor exhibited high selectivity towards lead ions and was successfully applied to their determination in tap water samples.  相似文献   

11.
An electrochemical method for the determination of tripelennamine hydrochloride (TPA) using cetyltrimethylammoniumbromide‐multiwalled carbon nanotubes modified glassy carbon electrode (MWCNT‐CTAB/GCE) was developed. Because of good electrical conductivity of MWCNT and catalytic behavior of CTAB, new electrode significantly enhances the sensitivity for the detection of TPA. Parameters such as amount of modifier suspension, scan rate, pH of measure solution, heterogeneous rate constant were investigated. The electrode exhibits a linear potential response in the range of 1.0×10?8 M to 3.0×10?6 M with a detection limit of 2.38× 10?9 M. The modified electrode was successfully applied to the determination of TPA in pharmaceutical and real samples.  相似文献   

12.
A sensitive electroanalytical method is presented for the determination of 4‐hexylresorcinol using adsorptive stripping voltammetry (AdsSV) at a multiwalled carbon nanotube modified basal plane pyrolytic graphite electrode (MWCNT‐BPPGE). This method is also extended to the use of a MWCNT modified screen‐printed electrode (MWCNT‐SPE), thereby demonstrating that this approach can easily be incorporated into a facile and inexpensive electrochemical sensor.  相似文献   

13.
A carbon‐coated iron nanoparticles (CIN, a new style fullerence related nanomaterial) modified glassy carbon electrode (CIN/GCE) has been developed for the determination of uric acid (UA). Electrochemical behaviors of UA on CIN/GCE were explored by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). It was found that the voltammetric response of UA on CIN/GC was enhanced dramatically because of the strong accumulation effect of CIN and the large working area of the CIN/GC electrode. The parameters including the pH of supporting electrolyte, accumulation potential and time, that govern the analytical performance of UA have been studied and optimized. The DPV signal of UA on CIN/GCE increased linearly with its concentration in the range from 5.0×10?7 to 2.0×10?5 M, with a detection limit of 1.5×10?7 M (S/N=3). The CIN/GCE was used for the determination of UA in samples with satisfactory results. The proposed CIN/GCE electrochemical sensing platform holds great promise for simple, rapid, and accurate detection of UA.  相似文献   

14.
《Electroanalysis》2005,17(9):806-814
The electrochemical behavior of a sonogel‐carbon electrode towards nine phenolic compounds (chloro‐, nitro‐ and alkyl‐phenols) was studied; one of them (4‐chloro‐3‐methylphenol) was used to evaluate characteristics of the electrode, such as accumulation and cleaning procedure of the electrode surface, reproducibility of the measurements, and influence of time from fabrication on electrochemical response. A polyethyleneglycol‐modified sonogel‐carbon electrode was found to improve the electrochemical response towards the analyte. A linear relationship between peak height and concentration in the range 0.005–0.5 mg L?1 was obtained, with a detection limit of 2.8 μg L?1. The studies of electrochemical parameters, as well as interferences, are also included.  相似文献   

15.
A new composite electrode has been fabricated based on coating multi‐walled carbon nanotubes (MWCNTs) and n‐octylpyridinum hexafluorophosphate (OPPF6) ionic liquid composite on a glassy carbon (GC) electrode (OPPF6‐MWCNTs/GCE). This electrode shows very attractive electrochemical performances for electrooxidation of risperidone (RIS) compared to conventional electrodes using carbon and mineral oil, notably improved sensitivity and stability. The oxidation peak potentials in cyclic voltammogram of RIS on the OPPF6‐MWCNTs/GCE was occurred around 230 mV vs. SCE at Britton–Robinson (B–R) buffer (pH 4.0) at scan rate of 100 mV s?1. The electrochemical parameters such as diffusion coefficient (D), charge transfer coefficient (α) and the electron transfer rate constant (k/s) were determined using cyclic voltammetry. Under the optimized conditions, the peak current was linear to risperidone concentration over the concentration range of 10–200 nM with sensitivity of 0.016 μA/nM?1 using differential pulse voltammetry. The detection limit was 6.54 nM (S/N = 3). The electrode also displayed good selectivity and repeatability. In the presence of clozapine (CLZ) the response of RIS kept almost unchanged. Thus this electrode could find application in the determination of RIS in some real samples. The analytical performance of the OPPF6‐MWCNTs/GCE was demonstrated for the determination of RIS in human serum and pharmaceutical samples.  相似文献   

16.
A new voltammetric sensor based on molecularly imprinted poly(acrylic acid)‐MWCNT nanocomposite (MIP‐MWCNT) drop‐coated onto glassy carbon electrode (GCE) was developed and applied to tramadol (TR) determination in pharmaceutical samples. The voltammetric sensor prepared by suspension of MIP‐MWCNT at 1 : 1 (w/w) ratio show an improved performance compared to unmodified GCE. The electrochemical method is based on preconcentration of tramadol onto MIP‐MWCNT modified GCE surface at ?1.5 V vs Ag/AgCl for 180 s in 0.1 Britton‐Robinson buffer (pH 8.0) at stirred solution. Upon preconcentration, the differential anodic voltammogram was recorded under the optimized condition giving rise to an analytical curve varying from 9.0 up to 30.0 μmol L?1 (R2=0.997) and limits of detection and quantification of 1.4 and 4.8 μmol L?1, respectively. The method precision was assessed in terms of intraday (n=6) and interday (two consecutive days) precision, giving relative standard deviations (RSD%) values between 2.8 to 7.4 %. Excipients usually found in pharmaceutical pills (magnesium stearate, microcrystalline cellulose, starch, and silica) and paracetamol were evaluated as potential interferents, however no interference was evidenced in TR determination. The method applicability was evaluated by TR analysis in pharmaceutical samples. Moreover, the method accuracy was attested by comparison of addition and recovery assays with a reference technique (high‐performance liquid chromatography).  相似文献   

17.
多巴胺是人体内一种重要的神经传递物质 ,它参与许多生命过程[1] .因此 ,测定体内多巴胺的浓度十分重要 .多巴胺的电化学分析方法已有不少报道 [2 ,3 ] .然而 ,共存的抗坏血酸和尿酸的电化学性质与多巴胺相似 ,对多巴胺的测定会产生严重干扰 .因此建立一种选择性测定多巴胺的高灵敏度的分析方法就显得尤为重要 .碳纳米管是一种新型的纳米材料 [4 ] ,它的出现引起了广泛的研究兴趣 [5,6] .由于其性质稳定 ,不溶于水及一般的有机溶剂 ,因此限制了其在电分析方面的应用 .本文将多壁碳纳米管分散在 Nafion的无水乙醇中 ,得到了一种均匀的多壁碳…  相似文献   

18.
We report the analytical performance of glassy carbon electrodes (GCE) modified with a dispersion of multiwall carbon nanotubes (MWCNT) in polylysine (Plys) (GCE/MWCNT‐Plys). The resulting electrodes show an excellent electrocatalytic activity towards different bioanalytes like ascorbic acid, uric acid and hydrogen peroxide, with important decrease in their oxidation overvoltages. The dispersion of 1.0 mg/mL MWCNT in 1.0 mg/mL polylysine is highly stable, since after 2 weeks the sensitivity for hydrogen peroxide at GCE modified with this dispersion remained in a 90% of the original value. The MWCNT‐Plys layer immobilized on glassy carbon electrodes has been also used as a platform to build supramolecular architectures by self‐assembling of polyelectrolytes based on the polycationic nature of the polylysine used to disperse the nanotubes. The self‐assembling of glucose oxidase has allowed us to obtain a supramolecular multistructure for glucose biosensing. The influence of glucose oxidase concentration and adsorption time as well as the effect of using polylysine or MWCNT‐Plys as polycationic layers for further adsorption of GOx is also evaluated.  相似文献   

19.
《Electroanalysis》2017,29(10):2401-2409
Copper nanoparticles (nano‐Cu) were electrodeposited on the surface of glassy carbon electrode (GCE) potentiostatically at −0.6 V vs. Ag/AgCl for 60 s. The developed nano‐copper modified glassy carbon electrode (nano‐Cu/GCE) was optimized and utilized for electrochemical assay of chemical oxygen demand (COD) using glycine as a standard. The surface morphology and chemical composition of nano‐Cu/GCE were investigated using scanning electron microscope (SEM) and energy dispersive X‐ray spectrometer (EDX), respectively. The electrochemical behavior was investigated using linear sweep voltammetry (LSV) which is characterized by a remarkable anodic peak at ∼0.6 V, compared to bare GCE. This indicates that nano‐Cu enhances significantly the electrochemical oxidation of glycine. The effect of different deposition parameters, such as Cu2+ concentration, deposition potential, deposition time, pH, and scan rate on the response of the developed sensor were investigated. The optimized nano‐Cu/GCE based COD sensor exhibited a linear range of 15 to 629.3 ppm, and a lower limit of detection (LOD) of 1.7 ppm (S/N=3). This developed method exhibited high tolerance level to chloride ion (0.35 M chloride ion has minimal influence). The analytical utility of the prepared COD sensor was demonstrated by investigating the COD recovery (99.8±4.3) and the assay of COD in different water samples. The results obtained were verified using the standard dichromate method.  相似文献   

20.
A silicon carbide nanoparticle‐coated glassy carbon electrode (SiCNPs‐GCE) was employed for electrochemical determination of Quinalphos (QNP) using different electroanalytical techniques. QNP showed an enhancement in the reduction peak current at SiCNPs modified GCE in pH 7.0 (BR Buffer). The peak current was found to be linear with the QNP concentration in the range from 6.69×10?9 to 1.34×10?6 M (r=0.995) with detection limit of 1.34×10?9 M (S/N=3). The developed sensor (SiCNPs‐GCE) was employed for QNP determination in tap water, lake water, soil, mango as well as in biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号