首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The fabrication and evaluation of a glassy carbon electrode (GCE) modified with ordered mesoporous carbon (OMC), 2‐mercaptoethanesulfonate (MES)‐tethered polyaniline (PANI) and bismuth for simultaneous determination of trace Cd2+ and Pb2+ by differential pulse anodic stripping voltammetry (DPASV) are presented here. The morphology and electrochemical properties of the fabricated electrode were respectively characterized by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). Experimental parameters such as PANI disposition, preconcentration potential, preconcentration time and bismuth concentration were optimized. Under optimum conditions, the fabricated electrode exhibited linear calibration curves ranged from 1 to 120 nM for Cd2+ and Pb2+. The limits of detection (LOD) were 0.26 nM for Cd2+ and 0.16 nM for Pb2+ (S/N=3), respectively. Additionally, repeatability, reproducibility, interference and application were also investigated, and the proposed electrode exhibited excellent performance. The proposed method could be extended for the development of other new sensors for heavy metal determination.  相似文献   

2.
《Electroanalysis》2017,29(8):1903-1910
This paper describes the electrochemical behaviors of Cd2+ and Pb2+ on the proposed mesoporous carbon microspheres/mefenamic acid/nafion modified glassy carbon electrode (MC/MA/Nafion/GC) studied by square wave anodic stripping voltammetry (SWASV). The prepared material is characterized by XRD, SEM, FTIR, RAMAN and BET analysis. Experimental parameters, such as the deposition potential and time, the pH value of buffer solution were optimized. Under the optimized conditions, the electrode responded linearly to Cd2+ and Pb2+ in the concentration range from 50 to 300 nM, and the detection limits were 24.2 and 11.26 nM respectively. The sensitivity determined was 0.0623 μA/nM (Cd2+) and 0.192 μA/nM (Pb2+). Multiple metal ion detection with clear demarcation of peaks was produced by the electrode. Moreover, the modified electrode has possessed good selectivity and reproducibility of Cd2+ and Pb2+ detection. We also investigated the interference of various anions and surfactants for the detection of Cd2+ and Pb2+ ions. Finally the modified electrode was used to detect the presence of metal ions in practical samples and the results obtained are comparatively good with respect to AAS.  相似文献   

3.
《Electroanalysis》2004,16(23):1977-1983
2,2‐bis(3‐Amino‐4‐hydroxyphenyl)hexafluoropropane (BAHHFP) was electro‐polymerized oxidatively on glassy carbon by cyclic voltammetry. The activity of the modified electrode towards ascorbic acid (AA), uric acid (UA) and dopamine (DA) was characterized with cyclic voltammetry and differential puls voltammetry (DPV). The findings showed that the electrode modification drastically suppresses the response of AA and shifts it towards more negative potentials. Simultaneously an enhancement of reaction reversibility is seen for DA and UA. Unusual, selective preconcentration features are observed for DA when the polymer‐modified electrode is polarized at negative potential. In a ternary mixture containing the three analytes studied, three baseline resolved peaks are observed in DPV mode. At physiological pH 7.4, after 5 min preconcentration at ?300 mV, peaks positions were ?0.073, 0.131 and 0.280 V (vs. Ag/AgCl) for AA, DA and UA, respectively. Relative selectivities DA/AA and UA/AA were over 4000 : 1 and 700 : 1, respectively. DA response was linear in the range 0.05–3 μM with sensitivity of 138 μA μM?1 cm?2 and detection limit (3σ) of 5 nM. Sensitive quantification of UA was possible in acidic solution (pH 1.8). Under such conditions a very sharp peak appeared at 630 mV (DPV). The response was linear in the range 0.5–100 μM with sensitivity of 4.67 μA μM?1 cm?2 and detection limit (3σ) of 0.1 μM. Practical utility was illustrated by selective determination of UA in human urine.  相似文献   

4.
In this paper a sensor to detect acetylcholine on the basis of ZnFe2O4 nanoparticles modified screen printed electrode (SPE) is reported. In the range 0.08–500.0 μM, with the detection limit of 0.024±0.001 μM, acquired anodic peak currents where shown to be linearly dependent on acetylcholine concentrations by differential pulse voltammetry (DPV). It was proven that acetylcholine oxidation at adjusted electrode surface takes place at 100 mV potential less positive compared to an unadjusted screen printed electrode. The electron transfer coefficient (α=0.51) and diffusion coefficient (D=9.3×10?6 cm2/s) of acetylcholine oxidation were determined too. In addition, this original sensor possesses numerous benefits such as reproducibility, high stability and rapid response (20 s).  相似文献   

5.
A novel method for the determination of Pb2+ with bismuth film electrodes (BFEs) based on magneto-voltammetry was investigated. In the presence of a 0.6?T external magnetic field, square wave voltammetry of Pb2+ was performed with BFEs. A high concentration of Fe3+ was added to the analytes to generate a large cathodic current during the preconcentration step. A Lorentz force from the flux of net current through the magnetic field resulted in convection. Then, more Pb2+ deposited onto the electrode and larger stripping peak currents were observed. BFEs that were prepared by simultaneously depositing the bismuth and Pb2+ on an electrode offered a mercury-free environment for this determination. This method exhibits a high sensitivity of 4.61?µA?µM?1 for Pb2+ over the 1?×?10?8 to 1?×?10?6?M range. A detection limit as low as 8.5?×?10?10?M was obtained with only 1-min preconcentration. The method was successfully applied to determine Pb2+ in real water samples.  相似文献   

6.
A novel electrode was prepared that enables sensing of lead(II) ion. A suspension composed of ordered mesoporous carbon (OMC), an ionic liquid (IL), and chitosan was deposited on the highly conductive surface of a carbon ionic-liquid electrode (CILE). The surface of the sensing electrode was characterized by scanning electron microscopy and cyclic voltammetry. The new electrode can be used to determine lead(II) ion because the hydrophobic ionic liquid of the CILE can extract Pb(II), while the OMC accelerates the electron transfer rate between the electrode and Pb(II) and also strongly adsorbs Pb(II). The resulting electrode displays excellent and synergistic response to Pb(II) which is linear in the range from 0.05 to 1.4?μM, with a correlation coefficient of 0.997 and a detection limit of 25 nM.
Figure
Differential pluse anodic stripping voltammograms of 5.0?×?10?7?M Pb2+ at (1) CPE (2) CILE, (3) OMC-chitosan/CILE, (4) IL2-chitosan/CILE and (5) OMC-IL2-chitosan/CILE in 10?mM HNO3. Accumulation potential: -1.05?V, accumulation time 200?s, pulse amplitude: 50?mV, pulse width: 50?ms.  相似文献   

7.
徐琴  刘妮娜  朱俊杰 《中国化学》2005,23(11):1510-1514
A composite material of nitric acid oxidized multiwalled carbon nanotube (MWNT) and Nation was prepared. Such composite was modified on a glassy carbon electrode to determine trace of lead by differential pulsed voltammetry. In pH=6.47 NaNO3 solution, Pb^2+ ions were accumulated on the modified electrode at -0.4 V. Compared with a bare and a Nation film coated electrode, the composite coated GC electrode can reduce the accumulating potential and eliminate the toxic character of mercury. The calibration plots were linear at low concentration of 5.0× 10^-9-2.0× 10^-8 mol/L and high concentration of 2.5× 10^-8-5.0× 10^-6 mol/L. The performances characteristics indicate that the electrode can be used to determine trace Pb^2+ ions.  相似文献   

8.
Robert Piech 《Electroanalysis》2008,20(22):2475-2481
The new cyclic renewable mercury film silver based electrode (Hg(Ag)FE), applied for the determination of selenium(IV) traces in the presence of copper ions using differential pulse cathodic stripping voltammetry (DP CSV) is presented. The preparation of the Hg(Ag)FE is very simple. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition are optimized. The calibration graph is linear from 0.5 nM (39 ng L?1) to 100 nM (7.9 μg L?1) for a preconcentration time of 45 s, with correlation coefficient of 0.9995. For a Hg(Ag)FE with a surface area of 8 mm2 the detection limit for a preconcentration time of 90 s is as low as 17 ng L?1. The repeatability of the method at a concentration level of the analyte as low as 2 μg L?1, expressed as RSD is 2.7% (n=7). The proposed method was successfully applied and validated by studying the certified reference material (bovine liver BCR‐185) and simultaneously recovery of Se(IV) from spiked water samples.  相似文献   

9.
A new chemically modified bismuth film electrode coated with an ionic liquid [(1‐ethyl‐3‐methylimidazolium tetracyanoborate (EMIM TCB)] and Nafion was developed for the simultaneous determination Pb2+ and Cd2+ by anodic stripping voltammetry. Compared with conventional bismuth film electrodes, this electrode exhibited greatly improved electrochemical activity for Pb2+ and Cd2+ detection due to the unique properties of Nafion polymer and ionic liquid. The key experimental parameters related to the fabrication of the electrode and the voltammetric measurements were optimized on the basis of the stripping signals, where the peak currents increased linearly with the metal concentrations in a range of 10–120 µg L?1 with a detect limit of 0.2 µg L?1 for Pb2+, and 0.5 µg L?1 for Cd2+ for 120s deposition. High reproducibility was indicated from the relative standard deviations (1.9 and 2.5 %) for nine repetitive measurements of 20 µg L?1 Pb2+ and Cd2+, respectively. In addition, the surface characteristics of the modified BiFE were investigated by scanning electron microscopy (SEM), and results showed that fibril‐like bismuth nanostructures were formed on the porous Nafion polymer matrix. Finally, the developed electrode was applied to determine Pb2+ and Cd2+ in water samples, indicating that this electrode was sensitive, reliable and effective for the simultaneous determination of Pb2+ and Cd2+.  相似文献   

10.
《Electroanalysis》2018,30(3):533-542
A simple and highly sensitive electrochemical sensor COOH−C4 derived from dicarboxyl‐calix[4]arene modified on a screen printed gold electrode (Au) was developed for the determination of lead ions in water samples. A 3‐mercaptopropionic acid (MPA) monolayer was used as a template on the gold electrode for the surface modification with dicarboxyl‐calixarene. The modified electrodes were surface‐characterized using Fourier Transform infrared spectroscopy (FTIR). The data obtained proved the confirmation of each stage of the electrode modification. The electrochemical analyses of the COOH−C4 electrode showed an enhanced electrocatalytic activity and higher current towards Pb2+ ions as compared to the bare Au and MPA/Au electrodes. Under optimum conditions, the differential pulse voltammetry response of COOH−C4 displayed a wide linear response ranging from 280–2500 μg/L for Pb2+ with a detection limit of 6.2 μg/L. In addition, the fabricated electrode showed a high selectivity and stability towards the Pb2+ ions in presence of possible interfering species. The present method was successfully applied to determine Pb2+ ions in real samples with satisfactory precision, with a relative standard deviation of 3.12 % and an acceptable recovery of 92 %, which demonstrated the potential application of dicarboxyl‐calix[4]arene modified on electrodes for heavy‐metal sensing.  相似文献   

11.
A new sensor was developed for simultaneous detection of cadmium (Cd2+), copper (Cu2+), and lead (Pb2+), based on the voltammetric response at a carbon paste electrode modified with carbamoylphosphonic acid (acetamide phosphonic acid) self-assembled monolayer (SAM) on mesoporous silica (Ac-Phos SAMMS). The adsorptive stripping voltammetry (AdSV) technique involves preconcentration of the metal ions onto Ac-Phos SAMMS under an open circuit, then electrolysis of the preconcentrated species, followed by a square wave potential sweep towards positive values. Factors affecting the preconcentration process were investigated. The voltammetric responses increased linearly with the preconcentration time from 1 to 30 min or with metal ion concentrations ranging from 10 to 200 ppb. The responses also evolved in the same fashion as adsorption isotherm in the pH range of 2-6. The metal detection limits were 10 ppb after 2 min preconcentration and improved to 0.5 ppb after 20 min preconcentration.  相似文献   

12.
Nafion‐coated antimony film electrode (NCAFE) was prepared in situ by simultaneously plated antimony with analytes, and applied to the determination of trace Pb(II) and Cd(II) in non‐deaerated solutions by differential pulse anodic stripping voltammetry (DPASV). Various experimental parameters, which influenced the response of the NCAFE to those metals, were thoroughly optimized and discussed. The results indicated that the sensitivity and resistance to surfactants at the NCAFE were remarkably improved with relative to the antimony film electrode (AFE). In the presence of 5 mg·L?1 gelatin, the peak heights at the NCAFE showed 4‐fold enhancement for Pb and a 9‐fold enhancement for Cd over a bare AFE. Reproducibility of the sensor was satisfactory, and the relative standard deviations were 4.8% for 20 μg·L?1 Pb and 3.2% for 25 μg·L?1 Cd (n=15) with preconcentration time of 180 s. The determination limits (S/N=3) of this sensor were determined to be 0.15 μg·L?1 for Pb and 0.30 μg·L?1 for Cd with accumulation time of 300 s. The NCAFE was successfully applied to determining Pb(II) and Cd(II) in vegetable and water samples with satisfactory results.  相似文献   

13.
Simple cyclic renewable silver amalgam film electrode (Hg(Ag)FE), applied for the determination of gallium(III) using differential pulse anodic stripping voltammetry (DP ASV), is presented. The effects of various factors such as: preconcentration potential and time, pulse height, step potential and supporting electrolyte composition are optimised. The calibration graph is linear from 5?nM (0.35?µg?L?1) to 80?nM (5.6?µg?L?1) for a preconcentration time of 60?s, with correlation coefficient of 0.995. For a Hg(Ag)FE with a surface area of 9.9?mm2 the detection limit for a preconcentration time of 120?s is as low as 0.1?µg?L?1. The repeatability of the method at a concentration level of the analyte as low as 3.5?µg?L?1, expressed as RSD is 3.2% (n?=?5). The proposed method was successfully applied by studying the synthetic samples and simultaneously recovery of Ga(III) from spiked aluminium samples.  相似文献   

14.
A new sensor has been developed for the simultaneous detection of cadmium, lead, copper and mercury, using differential pulse and square wave anodic stripping voltammetry (DPASV and SWASV) at a graphite–polyurethane composite electrode with SBA‐15 silica organofunctionalized with 2‐benzothiazolethiol as bulk modifier. The heavy metal ions were preconcentrated on the surface of the modified electrode at ?1.1 V vs. SCE where they complex with 2‐benzothiazolethiol and are reduced to the metals, and are then reoxidized. Optimum SWASV conditions lead to nanomolar detection limits and simultaneous determination of Cd2+, Pb2+, Cu2+ and Hg2+ in natural waters was achieved.  相似文献   

15.
A 2,2′‐azinobis (3‐ethylbenzothiazoline‐6‐sulfonate) diammonium salt (ABTS)‐multiwalled carbon nanotubes (MWCNTs) nanocomposite/Bi film modified glassy carbon (GC) electrode was constructed for the differential pulse stripping voltammetric determination of trace Pb2+ and Cd2+. This electrode was more sensitive than ABTS‐free Bi/GC and Bi/MWCNTs/GC electrodes. Linear responses were obtained in the range from 0.5 to 35 μg L?1 for Cd2+ and 0.2 to 50 μg L?1 Pb(II), with detection limits of 0.2 μg L?1 for Cd2+ and 0.1 μg L?1 for Pb2+, respectively. This sensor was applied to the simultaneous detection of Cd2+ and Pb2+ in water samples with satisfactory recovery.  相似文献   

16.
《Electroanalysis》2018,30(5):955-961
Herein, a sensitive electrochemical Pb2+ sensor was developed which based on DNA‐functionalized Au nanoparticles(AuNPs) and nanocomposite modified electrode. The DNA‐functionalized AuNPs includes two types of DNA, namely a Pb2+‐mediated DNAzyme comprising a biotin labeled‐enzyme DNA and a substrate strand DNA with a typical stem‐loop structure, and a ferrocene‐labeled linear signal DNA. Without Pb2+, the hairpin loop impeded biotin binding to avidin on the electrode. However,when the goal Pb2+ exists, the substratum strand was divided into two fragments that lead to the enzyme strand was substratumed on the electrode and biotin was admited by avidin, bringing about DNA‐functionalized AuNP(AuNPs) deposition on the electrode surface.The differential pulse voltammetry (DPV) was used to measure electrochemical response signals connect to signal DNA.For the amplification characters of the DNA‐functionalized AuNPs and nanocomposite, the electrochemical detection signal of Pb2+ was greatly improved and revealed high specificity. Under optimum conditions, the resultant biosensor bringed out a high sensitivity and selectivity for the determination of Pb2+. The proposed method was able to detect as low as picomolar Pb2+ concentrations.  相似文献   

17.
This paper describes the development of a new electrochemical sensor for 17β-estradiol (E2) determination based on glassy carbon electrode (GCE) modified with molecularly imprinted polymer grafted onto iniferter-multiwall carbon nanotubes surface (MIP-MWCNT) and dihexadecyl-hydrogen-phosphate (DHP). The electrochemical method was based on closed-circuit preconcentration of E2 in 0.1 mol L−1 phosphate buffer (pH 7.0) during 500 s. Upon preconcentration, E2 was determined by differential pulse voltammetry (DPV) exhibiting a limit of detection of 0.01 μmol L−1. The sensor exhibited higher selectivity toward E2 and it was applied for E2 determination in natural water samples, with accuracy attested by HPLC-DAD.  相似文献   

18.
This paper describes the fabrication, characterisation and the application of a Nafion/2,2′-bipyridyl/bismuth composite film-coated glassy carbon electrode (NC(Bpy)BiFE) for the anodic stripping voltammetric determination of trace metal ions (Zn2+, Cd2+ and Pb2+). The NC(Bpy)BiFE electrode is prepared by first applying a 2.5 mm3 drop of a coating solution containing 0.5 wt% Nafion and 0.1% (w/v) 2,2′-bipyridil (Bpy) onto the surface of a glassy carbon electrode, while the Bi film was plated in situ simultaneously with the target metal ions at −1.4 V. The main advantage of the polymer coated bismuth film electrode is that the sensitivity of the stripping responses is increased considerably due to the incorporation of the neutral chelating agent of 2,2′-bipyridyl (Bpy) in the Nafion film, while the Nafion coating improved the mechanical stability of the bismuth film and its resistance to the interference of surfactants. The key experimental parameters relevant to both the electrode fabrication and the voltammetric measurement were optimized on the basis of the stripping signals. With a 2 min deposition time in the presence of oxygen, linear calibration curves were obtained in a wide concentration range (about 2-0.001 μM) with detection limits of 8.6 nM (0.56 μg dm−3) for Zn2+, 1.1 nM (0.12 μg dm−3) for Cd2+ and 0.37 nM (0.077 μg dm−3) for Pb2+. For nine successive preconcentration/determination/electrode renewal experiments the standard deviations were between 3 and 5% at 1.2 μM for zinc and 0.3-0.3 μM concentration level for lead and cadmium, respectively, and the method exhibited excellent selectivity in the presence of the excess of several potential interfering metal ions. The analytical utility of the stripping voltammetric method elaborated was tested in the assay of heavy metals in some real samples and the method was validated by ICP-MS technique.  相似文献   

19.
Graphene nanosheets, dispersed in Nafion (Nafion-G) solution, were used in combination with in situ plated bismuth film electrode for fabricating the enhanced electrochemical sensing platform to determine the lead (Pb2+) and cadmium (Cd2+) by differential pulse anodic stripping voltammetry (DPASV). The electrochemical properties of the composite film modified glassy carbon electrode were investigated. It is found that the prepared Nafion-G composite film not only exhibited improved sensitivity for the metal ion detections, but also alleviated the interferences due to the synergistic effect of graphene nanosheets and Nafion. The linear calibration curves ranged from 0.5 μg L−1 to 50 μg L−1 for Pb2+ and 1.5 μg L−1 to 30 μg L−1 for Cd2+, respectively. The detection limits (S/N = 3) were estimated to be around 0.02 μg L−1 for Pb2+ and Cd2+. The practical application of the proposed method was verified in the water sample determination.  相似文献   

20.
The present paper has focused on the potential application of the bifunctional polydopamine@Fe3O4 core–shell nanoparticles for development of a simple, stable and highly selective electrochemical method for metal ions monitoring in real samples. The electrochemical method is based on electrochemical preconcentration/reduction of metal ions onto a polydopamine@Fe3O4 modified magnetic glassy carbon electrode at −1.1 V (versus SCE) in 0.1 M pH 5.0 acetate solution containing Pb2+ and Cd2+ during 160 s, followed by subsequent anodic stripping. The proposed method has been demonstrated highly selective and sensitive detection of Pb2+ and Cd2+, with the calculated detection limits of 1.4 × 10−11 M and 9.2 × 10−11 M. Under the optimized conditions, the square wave anodic stripping voltammetry response of the modified electrode to Pb2+ (or Cd2+) shows a linear concentration range of 5.0–600 nM (or 20–590 nM) with a correlation coefficient of 0.997 (or 0.994). Further, the proposed method has been performed to successfully detect Pb2+ and Cd2+ in aqueous effluent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号