首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
One-dimensional Ni/Au/PPy-COOH nanowires with multiple segments were synthesized in this study. Smooth surfaces and magnetic properties of nanowires were investigated by scanning transmission electron microscopy (SEM), Energy-dispersive X-ray spectroscopy (EDX), and Electron Spin Resonance (ESR) techniques. The nanowires were used to modify the screen-printed electrode surface and as a micro-environment for Trametes versicolor laccase. The ability of this enzyme biosensor to detect dopamine change in human biological samples was demonstrated by a wide linear range (0.01–50 μM) and a low LOD (2.265 nM). In addition, the biosensor exhibited excellent selectivity allowing the detection of dopamine in the presence of ascorbic acid, uric acid, L-Cys, serotonin, and glucose, with high sensitivity of reduction currents obtained at −0.2 V (vs. Ag/AgCl). The proposed biosensor allowed the detection of dopamine in commercial serum and artificial urine with recovery values close to 100 %. It also demonstrated reproducibility, reusability, and long-term storage stability. The sensitivity, Kmapp, and Imax values of the biosensor were determined as 2.05 μM and 1.03 μA, respectively. The LAC-Ni/Au/PPy-COOH/NAF/SPE biosensor is a reliable design for detecting dopamine with a wide linear range.  相似文献   

2.
Polymer-stabilized Pd nanoparticles on carbon support were synthesized by a low thermal procedure that does not involve the utilization of a reducing agent such as NaBH4 or hydrogen gas for the formation of the metallic nanoparticles. The Pd-catalyzed graphite particles were then mixed with known amounts of glucose oxidase (GOx) enzyme and Nafion to prepare a GOx-immobilized ink. A glassy carbon electrode (GCE) modified with the GOx ink was used to evaluate the performance of the biosensor electrode. The results of TEM and AFM show that the Pd nanoparticles are uniformly distributed on top of the substrate. Results are presented for sensing glucose through the voltammetric measurement of H2O2. Coupled with the simplicity of preparation, the biosensor exhibited high sensitivity and extended linear range for glucose measurement. Further, the electrochemical characteristics of the nanocomposite biosensor were evaluated with respect to the electrochemistry of potassium ferricyanide by cyclic voltammetry. Whereas the presence of polymer and Nafion improved the stability of both the ink and biosensor electrode, the concentration of glucose was measured without interferences from oxygen, ascorbic acid and uric acid because of the Nafion.  相似文献   

3.
Wu J  Zou Y  Gao N  Jiang J  Shen G  Yu R 《Talanta》2005,68(1):12-18
C/Fe nanocomposite (CFN) was synthesized by a procedure similar to an exfoliation/adsorption process to intercalate Fe3+ into graphite oxide (GO) layers and would be reduced in a H2 atmosphere. The results of X-ray diffractometry (XRD) and transimission electron microscopy (TEM) show that the form of CFN is carbon nanotube-Fe nanoparticle composite with α-Fe distributed on the nanotube wall. Paste electrode has been constructed using CFN mixed with paraffin. The electrochemical characteristics of such carbon-Fe nanocomposite paste electrode (CFNPE) has been compared with that of carbon paste electrode (CPE) and evaluated with respect to the electrochemistry of potassium ferricyanide, ascorbic acid and cysteine by cyclic voltammetry. CFNPE can accelerate the electron-transfer to improve the electrochemical reaction reversibility. To fabricate the third-generation glucose biosensor, glucose oxidase (GOD) was immobilized on CFNPE surface with Nafion covered after a pretreatment. Oxygen, ascorbic acid and uric acid have no interference with the glucose detection. The biosensor displays a remarkable sensitivity and stability and the results used in the determination of glucose in the human serum samples are satisfactory.  相似文献   

4.
One of the major problems in amperometric biosensors based on detection of H2O2 produced by enzymatic reaction between oxidase enzymes and substrate is the interference of redox active compounds such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). To minimize these interferences, sodium bismuthate was used for the first time as an insoluble pre‐oxidant in the flow injection (FI) amperometric glucose biosensor at a Glucose oxidase (GOx) immobilized Pt/Pd bimetallic modified pre‐anodized pencil graphite electrode (p.PGE). In this context, these interfering compounds were injected into a flow injection analysis (FIA) system using an injector which was filled with NaBiO3. Thus, these interferents were converted into their redox inactive oxidized forms before reaching the electrode in the flow cell. While glucose was not influenced by the pre‐oxidant in the injector, the huge oxidation peak currents of the interferents decreased significantly in the biosensor. FI amperometric current time curves showed that the AA, DA and UA were minimized by 96 %, 86 %, and 98 % respectively, in the presence of an equivalent concentration of interferences in a 1.0 mM glucose solution. The proposed FI amperometric glucose biosensor exhibits a wide linear range (0.01–10 mM, R2=0.9994) with a detection limit of 2.4×10?3 mM. Glucose levels in the artificial serum and two real samples were successfully determined using the fabricated FI amperometric biosensor.  相似文献   

5.
The gold nanostar@silica core–shell nanoparticles conjugated with glucose oxidase (GOx) enzyme molecules have been developed as the surface-enhanced Raman scattering (SERS) biosensor for label-free detection of glucose. The surface-immobilized GOx enzyme catalyzes the oxidation of glucose, producing hydrogen peroxide. Under laser excitation, the produced H2O2 molecules near the Au nanostar@silica nanoparticles generate a strong SERS signal, which is used to measure the glucose concentration. The SERS signal of nanostar@silica∼GOx nanoparticle-based sensing assay shows the dynamic response to the glucose concentration range from 25 μM to 25 mM in the aqueous solution with the limit of detection of 16 μM. The sensing assay does not show any interference when glucose co-exists with both ascorbic acid and uric acid. The sensor can be applied to a saliva sample.  相似文献   

6.
A simple procedure was developed to prepare a glassy carbon electrode modified with multi walled carbon nanotubes (MWCNTs) and Celestin blue. Cyclic voltammograms of the modified electrode show stable and a well defined redox couple with surface confined characteristic at wide pH range (2–12). The formal potential of redox couple (E′) shifts linearly toward the negative direction with increasing solution pH. The surface coverage of Celestine blue immobilized on CNTs glassy carbon electrode was approximately 1.95×10?10 mol cm?2. The charge transfer coefficient (α) and heterogeneous electron transfer rate constants (ks) for GC/MWCNTs/Celestine blue were 0.43 and 1.26 s?1, respectively. The modified electrode show strong catalytic effect for reduction of hydrogen peroxide and oxygen at reduced overpotential. The glucose biosensor was fabricated by covering a thin film of sol‐gel composite containing glucose oxides (GOx) on the surface of Celestine blue /MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 0.3 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. The accuracy of the biosensor for glucose detection was evaluated by detection of glucose in a serum sample, using standard addition protocol. In addition biosensor can reach 90% of steady currents in about 3.0 sec and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) was eliminated. Furthermore, the apparent Michaelis–Menten constant 2.4 mM, of GOx on the nano composite exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility of redox couple, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this procedure for modification of glucose biosensor.  相似文献   

7.
An amperometric glucose biosensor was successfully developed by electrochemical polymerization of p-chlorophenol (4-CP) at a Pt electrode in the presence of glucose oxidase. The amperometric response of this biosensor to hydrogen peroxide, formed as the product of enzymatic reaction, was measured at a potential of 0.6 V (vs. SCE) in phosphate buffer solution. The performances of sensors, prepared at different monomer concentrations and polymerization potentials, were investigated in detail. The biosensor prepared under optimal conditions had a linear response to glucose ranging from 2.5 × 10–4 to 1.5 × 10–2 mol L–1 with a correlation coefficient of 0.997 and a response time of less than 2 s. Substrate selectivity of the polymer-based enzyme electrode was tested for coexisting interferents such as uric acid and ascorbic acid, and no discernible response was observed. After 90 days, the response of the biosensor remained almost unchanged, indicating very good stability.  相似文献   

8.
A glucose biosensor has been fabricated by immobilizing glucose oxidase (GOx) on unhybridized titanium dioxide nanotube arrays using an optimized cross-linking technique. The TiO2 nanotube arrays were synthesized directly on a titanium substrate by anodic oxidation. The structure and morphology of electrode material were characterized by X-ray diffraction and scanning electron microscopy. The electrochemical performances of the glucose biosensor were conducted by cyclic voltammetry and chronoamperometry measurements. It gives a linear response to glucose in the 0.05 to 0.65 mM concentration range, with a correlation coefficient of 0.9981, a sensitivity of 199.6 μA mM?1 cm?2, and a detection limit as low as 3.8 µM. This glucose biosensor exhibited high selectivity for glucose determination in the presence of ascorbic acid, sucrose and other common interfering substances. This glucose biosensor also performed good reproducibility and long-time storage stability. This optimized cross-linking technique could open a new avenue for other enzyme biosensors fabrication.
Figure
A schematic diagram for the fabrication of unhybridized TiO2 nanotube arrays glucose biosensor via optimized cross-linking technique.  相似文献   

9.
Folic acid (FA) deficiency is associated with several clinical conditions such as megaloblastic anemia, neuropsychiatric, and pregnancy-related syndromes, this makes FA an important metabolite to be monitored. We have fabricated an electrochemical biosensor based on gold nanoparticles decorated molybdenum disulfide nanosheets (AuNPs−MoS2NSs) nanocomposite as a transducer matrix for specific and rapid electrochemical detection of FA. Differential pulse voltammetry (DPV) studies displayed a rapid analytical response of the fabricated AuNPs−MoS2NSs/GCE sensor probe towards FA in a wide concentration range of 0.001–100 μM with a very low detection limit of 0.72±0.03 nM. The selectivity of the fabricated sensor probe has been examined in the presence of interferents such as dopamine, uric acid, ascorbic acid, glucose, and urea. The clinical potential of the fabricated biosensor was established by monitoring FA in human serum samples. The developed AuNPs−MoS2NSs/GCE sensor probe showed high reproducibility and stability, indicating its promise for FA detection in clinical settings.  相似文献   

10.
A new H2O2 enzymeless sensor has been fabricated by incorporation of thionin onto multiwall carbon nanotubes (MWCNTs) modified glassy carbon electrode. First 50 μL of acetone solution containing dispersed MWCNTs was pipetted onto the surface of GC electrode, then, after solvent evaporations, the MWCNTs modified GC electrode was immersed into an aqueous solution of thionin (electroless deposition) for a short period of time <5–50 s. The adsorbed thin film of thionin was found to facilitate the reduction of hydrogen peroxide in the absence of peroxidase enzyme. Also the modified electrode shows excellent catalytic activity for oxygen reduction at reduced overpotential. The rotating modified electrode shows excellent analytical performance for amperometric determination of hydrogen peroxide, at reduced overpotentials. Typical calibration at ?0.3 V vs. reference electrode, Ag/AgCl/3 M KCl, shows a detection limit of 0.38 μM, a sensitivity of 11.5 nA/μM and a liner range from 20 μM to 3.0 mM of hydrogen peroxide. The glucose biosensor was fabricated by covering a thin film of sol–gel composite containing glucose oxides on the surface of thionin/MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 1 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. In addition biosensor can reach 90% of steady currents in about 3.0 s and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) is eliminated. The usefulness of biosensor for direct glucose quantification in human blood serum matrix is also discussed. This sensor can be used as an amperometric detector for monitoring oxidase based biosensors.  相似文献   

11.
In this communication, an amperometric glucose biosensor based on MnO2/MWNTs electrode was reported. MnO2 was homogeneously coated on vertically aligned MWNTs by electrodeposition. The MnO2/MWNTs electrode displayed high electrocatalytic activity towards the oxidation of glucose in alkaline solution, showing about 0.30 V negative shift in peak potential with oxidation starting at ca. −0.20 V (vs. 3 M KCl–Ag/AgCl) as compared with bare MWNTs electrode. At an applied potential of +0.30 V, the MnO2/MWNTs electrode gives a linear dependence (R = 0.995) in the glucose concentration up to 28 mM with a sensitivity of 33.19 μA mM−1. Meanwhile, the MnO2/MWNTs electrode is also highly resistant toward poisoning by chloride ions. In addition, interference from the oxidation of common interfering species such as ascorbic acid, dopamine, and uric acid is effectively avoided. The MnO2/MWNTs electrode allows highly sensitive, low-potential, stable, and fast amperometric sensing of glucose, which is promising for the development of nonenzymatic glucose sensor.  相似文献   

12.
A highly sensitive and selective glucose biosensor has been developed based on immobilization of glucose oxidase within mesoporous carbon nanotube–titania–Nafion composite film coated on a platinized glassy carbon electrode. Synergistic electrocatalytic activity of carbon nanotubes and electrodeposited platinum nanoparticles on electrode surface resulted in an efficient reduction of hydrogen peroxide, allowing the sensitive and selective quantitation of glucose by the direct reduction of enzymatically‐liberated hydrogen peroxide at ?0.1 V versus Ag/AgCl (3 M NaCl) without a mediator. The present biosensor responded linearly to glucose in the wide concentration range from 5.0×10?5 to 5.0×10?3 M with a good sensitivity of 154 mA M?1cm?2. Due to the mesoporous nature of CNT–titania–Nafion composite film, the present biosensor exhibited very fast response time within 2 s. In addition, the present biosensor did not show any interference from large excess of ascorbic acid and uric acid.  相似文献   

13.
Saliva opens a door for noninvasive and painless glucose testing since it reflects changes in the body physiology of diabetic individuals as compared to healthy ones. In this paper, a unique, disposable saliva biosensor has been developed for accurate, low cost, and continuous glucose monitoring. The biosensor exhibits linear dependence of the catalytic current upon glucose bulk concentration over the 0.05–1.5 mM range (R=0.998). A detection limit of 0.003 mM can be calculated considering three times the standard deviation of the blank signal divided by the sensitivity of the sensor. The selectivity of the biosensor was evaluated by adding the interferent species of lactate, ascorbic acid and uric acid into in 0.5 mM glucose; the nearly negligible interference current indicates its good selectivity. The operational stability of the biosensor was measured in 1 mM glucose over a 2 h period (RSD=3.27 %). A clinical trial on real‐time noninvasive salivary glucose monitoring was carried out on 30 individuals by measuring subjects’ salivary glucose and blood glucose in parallel. The results show that there is a good correlation of glucose levels in saliva and in blood 2 h after breakfast. Thus, the disposable biosensor would be a potential alternative for continuous glucose detection in human saliva.  相似文献   

14.
利用多壁碳纳米管(MWCNTs)和氧化锌(ZnO)纳米棒复合物膜构建了一种新的电流型葡萄糖生物传感器。MWCNTs-ZnO复合物在超声协助下通过静电配位的方式产生。其中,ZnO纳米棒的存在加强了该复合物催化氧化H2O2的能力,增加了响应电流。与单一的MWCNTs和ZnO相比,这种纳米复合物显示了更为有效地电催化活性。在此基础上,我们以MWCNTs-ZnO复合物膜为基底,用戊二醛交联法固定葡萄糖氧化酶,电聚合邻苯二胺(PoPD)膜为抗干扰层,构建了抗干扰能力强,稳定性好,灵敏度高,响应快的葡萄糖传感器。在+0.8V的检测电位下,该传感器对葡萄糖响应的线性范围为5.0×10-6~5.0×10-3mol·L-1(R=0.997),检测限为3.5×10-6mol·L-1(S/N=3),响应时间小于10s的葡萄糖生物传感器,常见干扰物质如抗坏血酸和尿酸不影响测定。  相似文献   

15.
《Electroanalysis》2004,16(15):1221-1226
A portable fill‐and‐flow channel biosensor with a “predictor electrode” is described. The predictor electrode, on the opposite channel wall and upstream of the detector electrode, allows direct evaluation of the current due to interfering species at the detector electrode. A model is developed which shows that the reaction at the upstream predictor electrode has no significant effect on the concentration distribution of the interfering species at the detector electrode. This enables a straightforward correction of the current at the detector electrode and a determination of the analyte concentration. The effect of interference from ascorbic acid in the detection of glucose in samples was efficiently removed by using such a concept. The recovery of glucose from samples containing ascorbic acid was 103% (s=12%, n=3). The approach was also applied to a biosensor for the determination of glucose in red wine samples containing polyphenolic interferents.  相似文献   

16.
A multilayered glucose biosensor via sequential deposition of Prussian blue (PB) nanoclusters and enzyme-immobilized poly(toluidine blue) films was constructed on a bare Au electrode using electrochemical methods. The whole configuration of the present biosensor can be considered as an integration of several independent hydrogen peroxide sensing elements. In each sensing element, the poly(toluidine blue) film functioned as both the supporting matrix for the glucose oxidase immobilization and the inhibitor for the diffusion of interferences, such as ascorbic acid and uric acid. Meanwhile, the deposited Prussian blue nanocluster layers acts as a catalyst for the electrochemical reduction of hydrogen peroxide formed from enzymatic reaction. Performance of the whole multilayer configuration can be tailored by artificially arranging the sensing elements assembled on the electrode. Under optimal conditions, the biosensors exhibit a linear relationship in the range of 1 x 10(-4) to 1 x 10(-2) mol/L with the detection limit down to 10(-5) mol/L. A rapid response for glucose could be achieved in less than 3 s. For 1 mM glucose, 0.5 mM acetaminophen, 0.2 mM uric acid, and 0.1 mM ascorbic acid have no obvious interferences (<5%) for glucose detection at an optimized detection potential. The present multilayered glucose biosensor with a high selectivity and sensitivity is promising for practical applications.  相似文献   

17.
Qian L  Yang X 《Talanta》2006,68(3):721-727
A new amperometric biosensor for hydrogen peroxide was developed based on cross-linking horseradish peroxidase (HRP) by glutaraldehyde with multiwall carbon nanotubes/chitosan (MWNTs/chitosan) composite film coated on a glassy carbon electrode. MWNTs were firstly dissolved in a chitosan solution. Then the morphology of MWNTs/chitosan composite film was characterized by field-emission scanning electron microscopy. The results showed that MWNTs were well soluble in chitosan and robust films could be formed on the surface. HRP was cross-linked by glutaraldehyde with MWNTs/chitosan film to prepare a hydrogen peroxide biosensor. The enzyme electrode exhibited excellent electrocatalytic activity and rapid response for H2O2 in the absence of a mediator. The linear range of detection towards H2O2 (applied potential: −0.2 V) was from 1.67 × 10−5 to 7.40 × 10−4 M with correction coefficient of 0.998. The biosensor had good repeatability and stability for the determination of H2O2. There were no interferences from ascorbic acid, glucose, citrate acid and lactic acid.  相似文献   

18.
The influence is discussed of ascorbic acid (AA) on the response of a glucose biosensor based on glucose oxidase immobilized in electropolymerized poly(ophenylenediamine) (PPD) or overoxidized poly(pyrrole) (oxPPy) films on a Pt electrode. The kinetics of the homogeneous reaction between AA and H2O2 has been investigated by two independent methods and found to be too slow to influence the response of typical glucose biosensors. Therefore, the decrease in the sensor response, observable when working in batch under typical experimental conditions, can in no way be ascribed to a depletion of H2O2, which is produced in the biocatalytic cycle via the homogeneous reaction with AA. While the purely additive Faradaic interference can practically be nullified by both entrapping membranes, electrode fouling by electro-oxidation products of AA (responsible for the observed decrease in glucose sensitivity) might still represent a problem when working with PPD based biosensors. In this respect the permeability characteristics of the film markedly influence the magnitude of the observed phenomena. The oxPPy film achieves the goal of completely eliminating ascorbate without blocking the access of glucose to the immobilized enzyme. Permanent address: Dipartimento di Chimica, Universita' della Basilicata, Via N. Sauro 85, I-85100 Potenza, Italy  相似文献   

19.
Qu F  Shi A  Yang M  Jiang J  Shen G  Yu R 《Analytica chimica acta》2007,605(1):28-33
Prussian blue nanowire array (PBNWA) was prepared via electrochemical deposition with polycarbonate membrane template for effective modification of glassy carbon electrode. The PBNWA electrode thus obtained was demonstrated to have high-catalytic activity for the electrochemical reduction of hydrogen peroxide in neutral media. This enabled the PBNWA electrode to show rapid response to H2O2 at a low potential of −0.1 V over a wide range of concentrations from 1 × 10−7 M to 5 × 10−2 M with a high sensitivity of 183 μA mM−1 cm−2. Such a low-working potential also substantially improved the selectivity of the PBNWA electrode against most electroactive species such as ascorbic acid and uric acid in physiological media. A detection limit of 5 × 10−8 M was obtained using the PBNWA electrode for H2O2, which compared favorably with most electroanalysis procedures for H2O2. A biosensor toward glucose was then constructed with the PBNWA electrode as the basic electrode by crosslinking glucose oxidase (GOx). The glucose biosensor allowed rapid, selective and sensitive determination of glucose at −0.1 V. The amperometric response exhibited a linear correlation to glucose concentration through an expanded range from 2 × 10−6 M to 1 × 10−2 M, and the response time and detection limit were determined to be 3 s and 1 μM, respectively.  相似文献   

20.
利用壳聚糖(CHI)溶液分散了纳米二氧化钛(nano-TiO2)和多壁碳纳米管(MWCNT),将该分散液修饰于玻碳电极表面形成纳米复合薄膜;用戊二醛为交联剂在该纳米复合层上固定了葡萄糖氧化酶(GOx),同时以二茂铁为电子媒介体构建了一种新型葡萄糖传感器。利用扫描电镜(SEM)、交流阻抗(AC)对所制备的传感器进行了表征,同时用循环伏安法(CV)和计时电流法(CA)考察了其对葡萄糖的电催化氧化性能。实验结果表明,在优化测试条件下该传感器对葡萄糖在0.5~20.0 mmol.L-1范围内有线性响应,检出限为0.2 mmol.L-1;电流达到95%的稳态时间小于5 s;此生物传感器具有良好的重现性和选择性,能有效排除抗坏血酸、尿酸等常见干扰物的影响并成功应用于饮料中葡萄糖含量的测定。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号