首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
We report the fabrication of a Ni nanoparticle modified BDD electrode and its application in the electrocatalysis of primary alcohol electrooxidation. Modification was achieved via electrodeposition from Ni(NO3)2 dissolved in sodium acetate solution (pH 5). Characterization of the Ni‐modified BDD (Ni‐BDD) was performed using ex situ atomic force microscopy (AFM) and high resolution scanning electron microscopy (SEM) coupled with energy dispersive X‐ray spectroscopy (EDX). Large nanoparticles of nickel were observed on the BDD surface ranging 5 to 690 nm in height and 0.18 μm?3 in volume, and an average number density of ca. 13×106 nanoparticles cm?2 was determined. The large range of sizes suggests progressive rather than instantaneous nucleation and growth. Electrocatalysis of ethanol and glycerol, was conducted in an alkaline medium using an unmodified BDD, Ni‐BDD and a bulk Ni macro electrode. The Ni‐BDD electrode gave the better electrocatalytic performance, with glycerol showing the greatest sensitivity. Linear calibration plots were obtained for the ethanol and glycerol additions over concentration ranges of 2.8–28.0 mM and 23–230 μM respectively. This gave an ethanol limit of detection of 1.7 mM and sensitivity of 0.31 mA/M, and the glycerol a limit of detection of 10.3 μM with a sensitivity of 35 mA/M.  相似文献   

2.
The electrochemical oxidation of procaine hydrochloride (PC?HCL, 2‐diethylaminoethyl 4‐aminobenzoate hydrochloride) was investigated at as‐deposited boron‐doped diamond (ad‐BDD) electrode, anodically oxidized BDD (ao‐BDD) electrode and glassy carbon (GC) electrode using cyclic voltammetry (CV). Well‐defined cyclic voltammograms were obtained for PC?HCL oxidation with high signal‐to‐background (S/B) ratio, low tendency for adsorption, good reproducibility and long‐term stability at ad‐BDD electrode, demonstrating its superior electrochemical behavior and significant advantages in contrast to ao‐BDD and GC electrode. At 100 μM PC?HCL, the voltammetric S/B ratio was nearly one order of magnitude higher at an ad‐BDD electrode than that at a GC electrode. In a separate set of experiments for oxidation of 100 μM PC?HCL, 96%, 92% and 84% of the initial oxidation peak current was retained at the ad‐BDD, ao‐BDD and GC electrode, respectively, by stirring the solution after the tenth cycle. The current response was linearly proportional to the square root of the scan rate within the range 10–1000 mV s?1 in 10 μM PC?HCL solutions, indicating that the oxidation process was diffusion‐controlled with negligible adsorption at an ad‐BDD surface. The good linearity was observed for a concentration range from 5 to 200 μM with a linear equation of y=0.03517x+0.65346 (r=0.999), and the detection limit was 0.5 μM for oxidation of PC?HCL at the ad‐BDD electrode. The ad‐BDD electrode could maintain 100% of its original activity after intermittent use for 3 months.  相似文献   

3.
A simple, rapid and feasible method is developed for direct and simultaneous determination of phenol (Ph), hydroquinone (HQ) and 4‐nitrophenol (4‐NP) on unmodified boron‐doped diamond (BDD) electrode. Results showed that the oxidative peaks of these three phenolic compounds can be completely separated on BDD electrode in acidic conditions by using electrochemical cyclic voltammetry technique. The peak potential separations are all higher than 0.35 V. Moreover, BDD electrode is extremely easy to be refreshed to obtain current values with good reproducibility, even if it is passivated by phenolic compounds with different adsorption characteristics. All the above features are on account of the outstanding electrochemical characteristics of BDD electrode, and lead to the advantage and feasibility for simultaneous determination of three phenolic compounds without any other separation operation. For each tested phenolic compound, the concentration range with linearity is in two or three orders of magnitude in the presence of other coexisting phenolic compounds with the concentrations more than 1000 times higher than that of the tested component. The present method is also shown to be promising for the determination of phenolic contaminants in the real wastewater samples.  相似文献   

4.
《Electroanalysis》2004,16(21):1777-1784
The surface of boron‐doped diamond (BDD) electrode is modified by the polymer film for the first time. The cationic polymer film of N,N‐dimethylaniline (DMA) is electrochemically deposited on BDD electrode surface. This polymer (PDMA) film‐coated BDD electrode is used as a sensor which selectively detect dopamine (DA) in the presence of ascorbic acid (AA). This electrode also can detect both DA and its metabolite, 3,4‐dihydroxy phenyl acetic acid (DOPAC) in the presence of AA in the range of the physiological concentrations of these species. Favorable ionic interaction (i.e., electrostatic attraction) between the PDMA film and AA or DOPAC lowers their oxidation potentials and enhances the current response for AA and DOPAC compared to that at the bare electrode. The PDMA film also shows a hydrophobic interaction with DA and DOPAC. In cyclic voltammetric measurements, the PDMA film‐coated electrode can successfully separate the oxidation potentials for AA and DA coexisting in the same solution and the separation is about 200 mV. AA oxidizes at more negative potential than DA. In square‐wave voltammetry, the sensitivity of the PDMA film‐coated BDD electrode for DA in the presence of higher concentration of AA is higher than that of the PDMA film‐coated glassy carbon electrode. The hydrodynamic amperometric experiments confirm that the oxidation of AA is not affected by the oxidized product of DA and vice versa. So, unlike the bare electrode the catalytic oxidation of AA by the oxidized DA is eliminated at the PDMA film‐coated BDD electrode. The sensitivities of the modified electrode for AA, DA and DOPAC, which are present in the same solution with their physiological concentration ratios, are calculated to be 0.070, 0.363 and 0.084 μA μM?1, respectively. The modified electrode exhibits a stable and sensitive response to DA.  相似文献   

5.
《Electroanalysis》2006,18(8):830-834
A facile method for the simultaneous measurement of tryptophan (Trp) and tyrosine (Tyr) was firstly exploited at unmodified boron‐doped diamond (BDD) electrode. The experimental results indicated that by using differential pulse voltammetry, the oxidative peaks of these two kinds of amino acids could be completely separated at BDD electrode. The peak separation of Trp and Tyr was developed to be 0.64 V when Na2PO4/NaOH buffer solution with the optimized pH 11.2 was employed. The detection limit of Trp was obtained to be 1×10?5 M, while that of Tyr was achieved to be 1×10?6 M. The present method was also evidenced to be available to the determination of real samples of amino acids.  相似文献   

6.
A nickel modified boron doped diamond (Ni‐BDD) electrode and nickel foil electrode were used in the determination of methanol in alkaline solutions. The Ni‐BDD electrode was electrodeposited from a 1 mM Ni(NO3)2 solution (pH 5), followed by repeat cycling in KOH. Subsequent analysis utilised the Ni(OH)2/NiOOH redox couple to electrocatalyse the oxidation of methanol. Methanol was determined to limits of 0.3 mM with a sensitivity of 110 nA/mM at the Ni‐BDD electrode. The foil electrode was less sensitive achieving a limit of 1.6 mM and sensitivity of 27 nA/mM. SEM analysis of the electrodes found the Ni‐BDD to be modified by a quasi‐random microparticle array.  相似文献   

7.
Antimony is an element of significant environmental concern, yet has been neglected relative to other heavy metals in electroanalysis. As such very little research has been reported on the electroanalytical determination of antimony at unmodified carbon electrodes. In this paper we report the electrochemical determination of Sb(III) in HCl solutions using unmodified carbon substrates, with focus on non-classical carbon materials namely edge plane pyrolytic graphite (EPPG), boron doped diamond (BDD) and screen-printed electrodes (SPE). Using differential pulse anodic stripping voltammetry, EPPG was found to give a considerably greater response towards antimony than other unmodified carbon electrodes, allowing highly linear ranges in nanomolar concentrations and a detection limit of 3.9?nM in 0.25?M HCl. Furthermore, the sensitivity of the response from EPPG was 100 times greater than for glassy carbon (GC). Unmodified GC gave a comparable response to previous results using the bare substrate, and BDD gave an improved, yet still very high limit of detection of 320?nM compared to previous analysis using an iridium oxide modified BDD electrode. SPEs gave a very poor response to antimony, even at high concentrations, observing no linearity from standard additions, as well as a major interference from the ink intrinsic to the working electrode carbon material. Owing to its superior performance relative to other carbon electrodes, the EPPG electrode was subjected to further analytical testing with antimony. The response of the electrode for a 40?nM concentration of Sb(III) was reproducible with a mean peak current of 1.07?µA and variation of 8.4% (n?=?8). The effect of metals copper, bismuth and arsenic were investigated at the electrode, as they are common interferences for stripping analysis of antimony.  相似文献   

8.
A non-enzymatic direct electrochemical glycerol detection method at a commercial boron-doped diamond (BDD) electrode in 0.1 M NaOH supporting electrolyte was developed. All the used electrochemical techniques proved useful features for the oxidation and direct amperometric determination of glycerol at a BDD electrode in 0.1 M NaOH aqueous solution. It was found that the direct electrooxidation of glycerol on the BDD electrode requires both adsorbed glycerol and hydroxyls at the electrode surface. Also, the sp(2) carbon did not allow enhancement of the glycerol oxidation process. The electronalytical sensitivity for the determination of glycerol at the BDD electrode ranged from 0.040 to 0.226 μA mM(-1) as a function of the technique used. The highest electroanalytical sensitivity for the determination of glycerol at the BDD electrode was reached in batch system amperometric quantification under stirring conditions. Performed recovery studies indicated that it is possible to determine glycerol in real samples, and the proposed batch system analysis-based methodology can be a valuable tool for practical glycerol analysis.  相似文献   

9.
The electrochemical behaviors of formaldehyde (FA) at boron‐doped diamond (BDD) electrodes are investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and linear scanning voltammetry (LSV) techniques. The CV results show that the oxidation reaction of FA is influenced by the hydroxyl concentration in the solution, and the peak current response with the FA concentration is linear at the range from 10 to 100 mM. The differential capacitance from EIS results indicate that the FA molecules adsorb at the BDD electrode surface at low potential (from 1.0 to 1.4 V). The kinetic studies have been examined with the various concentrations of FA, pH, and temperature. The activation energy of FA oxidation is also calculated. The results of kinetic study indicate that the adsorption of FA molecules at the BDD electrode is the rate‐determining step at low potential (from 1.0 to 1.40 V).  相似文献   

10.
Au/TiO2 nanorod composites with different ratios of [TiO2]:[Au] have been prepared by chemically reducing AuCl4 on the positively charged TiO2 nanorods surface and used to modify boron‐doped diamond (BDD) electrodes. The electrochemical behaviors of catechol on the bare and different Au/TiO2 nanorod composites‐modified BDD electrodes are studied. The cyclic voltammetric results indicate that these different Au/TiO2 nanorod composites‐modified BDD electrodes can enhance the electrocatalytic activity toward catechol detection, as compared with the bare BDD electrode. Among these different conditions, the Au/TiO2‐BDD3 electrode (the ratio of [TiO2]:[Au] is 27:1) is the most choice for catechol detection. The electrochemical response dependences of the Au/TiO2‐BDD3 electrode on pH of solution and the applied potential are studied. The detection limit of catechol is found to be about 1.4 × 10‐6 M in a linear range from 5 × 10‐6 M to 200 × 10‐6 M on the Au/TiO2‐BDD3 electrode.  相似文献   

11.
A new boron doped diamond microcells (BDD) was modified, for rapid, selective and highly sensitive determination of nitrite, using a coating film of polyoxometalates (POMs), formed by cyclic voltammetry on the molecular p‐phenylenediamine (PPD) functionalized BDD. The scanning electron microscopy (SEM) technique was used to examine the morphology of (PPD/SiW11) modified (BDD) electrode. It was found that (SiW11) layer was uniformly formed on the electrode surface. It was observed that (BDD/PPD/SiW11) showed excellent electrocatalytic activities towards nitrite ion. Under the selected conditions, the anodic peak maximum at ?0.6 V was linear versus nitrite concentration in the 40 µM–4 mM range, and the detection limit obtained was 20 µM. The newly developed electrode has been successfully applied to the determination of nitrite content in real river water samples.  相似文献   

12.
Boron‐doped Diamond (BDD) electrode has become one of the important tools for heavy metal detection. By studying some analytical parameters of DPASV method, like deposition time and potential in different electrolyte concentrations (acetate buffer), the conditions for detecting very low metal ion levels (Zn, Cd, Pb, and Cu) could be chosen. Diluted electrolyte (0.01 M buffer) was one of the factors favoring low detection and quantification limits, but its quantification range is short in comparison to more concentrated media. For ?1.7 V deposition potential, the detection of single metal at ppb levels was reached in 60 s deposition time. Understanding different metal‐metal interactions shows the limits to the simultaneous determination of heavy metals at BDD. Quantification was possible for the simultaneous determination of Zn, Cd and Pb despite the overlapping of Zn and Cd peaks. The performance of the BDD was compared with that of another C‐based solid electrode: the glassy carbon electrode (without mercury plating). A lower base line current, wider potential range, higher sensitivity (3 to 5 times higher than GC) and longevity of the material were noticed for the BDD.  相似文献   

13.
The adsorption of nitrogen species, in neutral electrolyte solutions, onto boron-doped diamond (BDD) electrode surfaces from dissolved NO2, NO, and N2O gases was induced at 0 V/SCE. Modified BDD electrode surfaces showed a different electrochemical response toward the hydrogen evolution reaction than did a nonmodified electrode surface in electrolyte base solution. The formation of molecular hydrogen and nitrogen gaseous species was confirmed by the online differential electrochemical mass spectrometry (DEMS) technique. Among the three nitrogen oxides gases, NO2 substantially modifies the electrolyte via hydrolysis leading to the formation of NO3- and its adsorption on the BDD electrode surface. The BDD/(NO3-) interface was the only N2O and N2 species generating system.  相似文献   

14.
Boron-doped diamond (BDD) and glassy carbon (GC) electrodes are compared for electrochemical oxidation of methanol and benzyl alcohol. Cyclic voltammograms reveal that BDD electrode produces good oxidation signals for both methanol and benzyl alcohol, while GC produces no significant oxidation signal for either methanol or benzyl alcohol. Amperometric measurement of oxidation of methanol and benzyl alcohol on BDD shows development of a fouling film for benzyl alcohol but not for methanol. Prolonged (24 h) polarization of the BDD electrode at +2.0 V in benzyl alcohol generated enough fouling film for investigation by AFM, SEM, Raman, and FTIR techniques. AFM and SEM microscopy images confirm a fouling film confined to the low-lying regions of the polycrystallite BDD surface, indicating that the active sites of benzyl alcohol oxidation are located within these low-lying regions. The fouling material generated in the process of benzyl alcohol oxidation was identified from Raman and FTIR spectroscopy as polyester. Experiments confirm the fouling film can be removed and the electrode surface reactivated by brief polarization at +3.0 V. Amperometric results of concentration dependence confirm the BDD electrode is well suited for quantitative analysis applications of methanol and benzyl alcohol, with recognizable oxidation currents at micromolar concentration levels.  相似文献   

15.
Spectroelectrochemical sensors combine electrochemistry, spectroscopy, and partitioning into a film to provide improved selectivity for the target analyte. The sensor usually consists of an optically transparent electrode (OTE) coated with a charge selective polymer film. The polymer film is chosen to pre‐concentrate analyte at the OTE surface to improve the sensitivity and provide selectivity against like charged interferences. OTEs such as Indium Tin Oxide (ITO) have been used extensively for spectroelectrochemical sensors, but little is known about the applicability of such sensors using other OTE materials, such as Boron Doped Diamond (BDD). One distinct advantage of BDD OTEs over ITO OTEs is their significant increase in sensitivity for organic compounds, such as 4‐aminophenol and hydroquinone. We have developed absorption and fluorescence‐based sensing methods with a BDD OTE coated with a sulfonated ionomer film, Nafion. This is demonstrated with tris(2,2′‐bipyridyl)ruthenium(II) ion [Ru(bpy)32+] using an attenuated total reflectance (ATR) flow cell setup for both absorption and fluorescence. With a Nafion coated BDD optically transparent thin layer electrode (OTTLE), we developed a fluorescence based sensor for a common polyaromatic hydrocarbon (PAH), 1‐hydroxypyrene (1‐pyOH), achieving a detection limit of 80 nM (17 ppb). This work manifests new sensing applications while broadening the use of spectroelectrochemistry, OTEs, and BDD as an electrode material.  相似文献   

16.
The performance of hydrogen‐ (HT) and oxygen‐terminated (OT) boron‐doped diamond (BDD) electrodes (electrochemically pretreated) on the simultaneous differential pulse voltammetric determination of sulfamethoxazole and trimethoprim in pharmaceutical products is presented. Under the optimum analytical experimental conditions, the HT‐BDD electrode presented two well‐defined oxidation peaks at 920 and 1100 mV vs. Ag/AgCl for sulfamethoxazole and trimethoprim, respectively. On the other hand, when the OT‐BDD electrode was used, the sulfamethoxazole oxidation current peak was decreased twenty fold. The calculated LOD values for sulfamethoxazole and trimethoprim using the HT‐BDD electrode were 3.65 μg L?1 and 3.92 μg L?1, respectively. The results obtained in the simultaneous determination of sulfamethoxazole and trimethoprim in three different commercial formulations were similar to those obtained using a standard HPLC method at 95% confidence level.  相似文献   

17.
《Analytical letters》2012,45(13):2581-2589
Abstract

The characteristics of the boron‐doped diamond (BDD) electrode in this work were studied by atomic force microscope (AFM), scanning electron microscopy, and Raman spectroscopy. The electro‐oxidation of formaldehyde at the BDD electrode in 0.5 M K2SO4 with different pH was studied by cyclic voltammetry and amperometry. There is no significant oxidation peak of formaldehyde in acidic solution because the oxidation of formaldehyde is at the potential range of water discharge. However, in neutral solution, there is a well‐defined oxidation peak at about +2.2 V vs. Ag/AgCl. The relation between the response current and formaldehyde concentration is linear behavior at the concentration range from 50 to 600 µM. Besides, in neutral solution, the oxidation of formaldehyde is dominated by indirect oxidation at lower formaldehyde concentration, and it is dominated by direct oxidation at higher concentration. Finally, in alkaline solution, the oxidation of formaldehyde is dominated by indirect oxidation caused by a powerful oxidant and is related to the ratio of the amounts of formaldehyde and OH molecules at the BDD electrode surface.  相似文献   

18.
The Au/chitosan fiber was firstly prepared by electrospinning and chemical reduction method and used to modify BDD electrode for the detection of methyl parathion. The results indicated that Au/chitosan fiber‐modified BDD electrode could improve the electrocatalytic activity, accelerate response, enhance the sensitivity, and reduce the detection limit, as compared with the bare BDD electrode. The repeatability and stability of Au/chitosan fiber‐modified BDD electrode was also studied. For the detection of methyl parathion in the apple juice samples, Au/chitosan fiber‐modified BDD electrode obtained favorable results and ideal recovery rate.  相似文献   

19.
This work compares polished and unpolished boron doped diamond (BDD) electrodes decorated with two sizes of gold nanoparticles (AuNPs) for use as robust mercury sensors in aquatic environments. The size of the catalytically active AuNPs on the electrode surfaces was demonstrated to have a less significant effect on the sensitivity for mercury detection than the surface preparation of the BDD. The lowest limits of detection were achieved with the polished BDD electrodes, which both detected mercury at a concentration of 1 pM, six orders of magnitude greater sensitivity than the lowest detection limit of 5 μM achieved with an unpolished BDD electrode, and high in comparison with other reported electrode systems.  相似文献   

20.
《Electroanalysis》2006,18(16):1590-1597
This work proposes the utilization of a boron doped diamond (BDD) electrode as a sensor for pesticides and as well as an anode for electrochemical combustion of Parathion in spiked, pure and natural waters. The square‐wave voltammetry was selected as the electroanalytical technique and the Britton–Robinson buffer as the electrolyte. The electrochemical reduction responses of Parathion were analyzed and compared with those previously obtained using a hanging mercury electrode (HMDE). The detection and quantification limits were calculated from the analytical curves both for BDD and HMDE in Milli‐Q water (2.4 and 7.9 μg L?1 and 3.9 and 12.8 μg L?1 respectively) showing only a slight improvement when used BDD. However, if the application involves polluted natural waters the improvement is accentuated due to the very low adsorption characteristics of BDD, which prevent the fouling of electrode surface by organic pollutants. The BDD was also used as anode for electrochemical remediation of Parathion contamination. In this case, electrolysis was carried out in high positive potential (3.0 V) and lead the electrochemical combustion of Parathion to CO2 and H2O, as measured by the diminishing of total organic carbon in the electrolyte.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号