1.
茶汤及河水中铬的形态分析   总被引:11,自引:0,他引:11  
本文采用717型强碱性阴离子交换树脂、活性炭分离富集与偶氮胂Ⅲ光度法结合,研究了铬形态的分离及测定,提出了铬的形态分析方法,有此法测定了茶汤及河水中铬的总量,悬浮态.溶解态、无机态、有机态、Cr(Ⅲ)和Cr(Ⅵ)。茶汤中铬主要以有机态存在,而河水中铬则主要以悬浮态存在。  相似文献   

2.
《Electroanalysis》2006,18(12):1159-1166
This paper proposes a procedure for the speciation of antimony by Differential Pulse Adsorptive Stripping Voltammetry (DPAdSV) using pyrogallol red (PGR) as a complexing agent. It employs a Partial Least Squares regression (PLS) in the resolution of strongly overlapping voltammetric signals obtained from mixtures of Sb(III) and Sb(V) in the presence of pyrogallol red. The absolute value of the relative error was less than 3.5% when concentrations of several mixtures were calculated, the minimum concentrations being 9.98×10?9 mol dm?3 and 4.87×10?8 mol dm?3 for Sb(III) and Sb(V), respectively. Any undue effects caused by the presence of foreign ions in the solution were also analyzed. The procedure was successfully applied to the speciation of antimony in pharmaceutical preparations.  相似文献   

3.
以纳米ZrO2为微柱填充材料,采用电感耦合等离子-质谱(ICP-MS)研究了Cr(Ⅵ)/Cr(Ⅲ)在纳米ZrO2微柱上的吸附性能。当pH值为8时,纳米ZrO2能完全吸附Cr(Ⅲ),而对Cr(Ⅵ)基本不吸附。对影响Cr(Ⅵ)和Cr(Ⅲ)分离的主要因素进行了详细研究,据此建立了纳米ZrO2微柱分离ICP-MS分析铬形态的新方法。方法对铬的检出限(3σ)为0.06ng/mL,定量测定下限(10σ)为0.37ng/mL,相对标准偏差为2.2%(n=9,c=100ng/mL)。本法选择性好、简便、快速,已用于不同水样中铬形态的测定,结果满意。  相似文献   

4.
A sensitive voltammetric method (DPASV) was developed for the determination of Tl(I) and Tl(III) in plant extracts. To limit the influence of the organic matrix on the measurements, UV irradiation and addition of Amberlite XAD‐7 resin was studied. The application of 0.5 g of the resin allowed defining thallium speciation in 10.0 mL of a solution containing 0.20 mL of Sinapis alba extract. The quantification limit of 0.5 ng mL?1 Tl(I) was found for only 10 min of preconcentration, and is low enough to allow dilution of the sample before thallium determination. The procedure was validated using the recovery study and intermethod comparison with HPLC ICP MS.  相似文献   

5.
《Electroanalysis》2004,16(21):1745-1754
This works reports the use of adsorptive stripping voltammetry (AdSV) for the trace determination of chromium on a rotating‐disk bismuth‐film electrode (BFE). During the reductive accumulation step, all the chromium species in the sample were reduced to Cr(III) which was complexed with cupferron and the complex was accumulated by adsorption on the surface of a preplated BFE. The stripping step was carried out by using a square‐wave (SW) potential‐time voltammetric signal. Electrochemical cleaning of the bismuth film was employed, enabling the same bismuth film to be used for a series of measurements in the presence of dissolved oxygen. The experimental variables as well as potential interferences were investigated and the figures of merit of the method were established. Using the selected conditions, the 3σ limit of detection for chromium was 100 ng L?1 (for 120 s of preconcentration) and the relative standard deviation was 3.6% at the 2 μg L?1 level (n=8). Finally, the method was applied to the determination of chromium in real samples with satisfactory results.  相似文献   

6.
吸附溶出伏安法测定苯胺的研究   总被引:7,自引:2,他引:7  
在酸性介质中,苯胺与亚硝酸根离子和盐酸萘乙二胺反应生成玫瑰红色偶氮染料,该染料在汞电极上具有良好的吸附性能,并且在氨性缓冲介质中可在汞电极上还原,于-0.55V左右产生一灵敏的吸附极谱波。据此,建立了吸附溶出伏安法测定苯胺的方法。当吸附富集时间为3min时,该法的检测下限为5×10-9mol/L,比分光光度法降低了近两个数量级。应用本方法测定了废水中的苯胺,结果满意。  相似文献   

7.
电化学分析法在铬形态分析中应用进展   总被引:2,自引:0,他引:2  
对近年来电化学分析法应用于铬的形态分析的现状和发展趋势进行了概述。  相似文献   

8.
This paper describes a new voltammetric procedure for the inorganic speciation of As(III) and As(V) in water samples. The procedure is based on the chemical reduction of arsenate [As(V)] to arsenite [As(III)] followed by the voltammetric determination of total arsenic as As(III) at the hanging mercury drop electrode (HMDE) by adsorptive cathodic stripping voltammetry (AdCSV) in the presence of sodium diethyl dithiocarbamate (SDDC). The reduction step involved the reaction with a mixture of Na2S2O5 and Na2S2O3 in the concentrations 2.5 and 0.5 mg mL?1, respectively, and the sample heating at 80 °C for 45 min. The linear range for the determination of total arsenic as As(III) in the presence of SDDC was between 5 and 150 μg L?1 for a deposition time of 60 s (r=0.992). A detection limit of 1.05 μg L?1 for total As was calculated for the method in water samples using a deposition time of 60 s. The detection limits of 4.2 μg L?1 and 15.0 μg L?1 for total As in seawater and dialysis concentrates, respectively, were calculated using a deposition time of 60 s. The relative standard deviations calculated were 2.5 and 4.0% for five measurements of 20 μg L?1 As(V) as As(III) in water and dialysis concentrates, respectively, after chemical reduction under optimized conditions. The method was applied for the determination of As(III) and total As in samples of dialysis water, mineral water, seawater and dialysis concentrates. Recovery values between 86.0 and 104.0% for As(III) and As(V) added to the samples prove the satisfactory accuracy and applicability of the procedure for the arsenic monitoring.  相似文献   

9.
《Analytical letters》2012,45(13):1519-1531
Abstract

The application of adsorptive stripping analysis in combination with differential pulse voltammetry for the determination of some triazine- and nitro group- containing pesticides like Dinobutone, DNOK, Ametryne and Prometryne is described. Conditions for determinations in the concentration range from approx. 0.1 to 50 ppb are given.  相似文献   

10.
Determination of Chromium in Natural Water by Stripping Voltammetry   总被引:1,自引:0,他引:1  
Conditions were optimized for determining microgram amounts of chromium by stripping voltammetry with a modified carbon-paste electrode. The developed procedures were applied to the analysis of different waters. The proposed procedures exhibit high performance characteristics and ensure the determination of 9.6 × 10–9 to 1.0 × 10–6 M chromium.  相似文献   

11.
提出了用神经网络方法测定无机铬的形态。在Back Propagation(BP)算法的基础上,吸取了模拟退火算法的优点,解决了BP算法容易陷入局部极小点的问题。经实际样品分析,结果满意。  相似文献   

12.
本实验对含13味中药的治肺癌复方原药,头煎及二煎残渣和浸汁,经0.45μ膜分离的颗粒物,可溶态,以及可溶态分别通过阳离子交换树脂,用三氯甲烷萃取后所得各自柱截留物,穿过物,有机相,水相等共15个样品中铬,镍,按照中药微量元素初级和次形态分析的要求,进行分析测定,以此计算出一套形态分析参数和相关数据,为探讨中草约中微量元素的化学形态提供了新的信息。  相似文献   

13.
The paper reports on the application of stripping chronopotentiometry for the determination of chromium(VI) at a silver‐based amalgam film electrode. It is the first attempt to apply such a detection system for the speciation of chromium. The procedure utilized catalytic reduction of nitrate ions induced by the instantaneous chromium(III)‐DTPA complex, accumulated at the electrode surface. The chronopotentiometric step is realized in the constant current mode. Several key parameters, such as the deposition potential, deposition time, nitrate concentration and stripping current were optimized. The detection limit obtained for 15 s of accumulation time was estimated at 0.025 µg/L. The repeatability of the signal was 6.1 %.  相似文献   

14.
A modification of the voltammetric procedure for the determination of uranium in the presence of cupferron using hanging mercury drop electrode is presented. The pulsed potential accumulation was proposed for the minimization of interferences of surface active substances. The calibration plot for U(VI) in the presence of 2 ppm Tritonu X‐100 was linear from 1.7×10?10 to 2.0×10?8 mol L?1 for an accumulation time of 60 s, with correlation coefficient of 0.996. The application of this method was tested in the determination of uranium in certified reference material NASS‐5 and river water samples.  相似文献   

15.
吸附溶出伏安法测定普罗帕酮的研究   总被引:1,自引:0,他引:1  
在pH 6.47的磷酸盐缓冲溶液中,可得到普罗帕酮的吸附溶出峰。峰电位为-1.38V(vs.Ag/AgCl),富集1min,溶出峰电流与普罗帕酮浓度在8.0x10~(-9)~7.0x10~(-7)mol/L范围内呈线性关系。富集4min检测下限为3.0×10(-10)mol/L。该法用于测定普罗帕酮制剂及人血清中的痕量普罗帕酮,均得到了满意的结果,并探讨了电极反应过程机理。  相似文献   

16.
报道了测定痕量镉的一种新方法.在0.01mol/LHAc-0.01mol/LNaAc-1.2×10-5mol/L乙醛酸缩氨基硫脲(GATSC)体系中,Cd-GATSC产生一灵敏的吸附还原波,波的峰电位是-0.43V(vs·SCE),峰电流与镉的浓度在1.0×10-8~8.0×10-7mol/L范围内成直线关系.此法用于测定水中痕量镉,结果令人满意。  相似文献   

17.
A new method using differential pulse adsorptive stripping voltammetry for the determination of atrazine (ATZ) in natural water samples using a bismuth film electrode (BiFE) is proposed. The calibration curve was linear in the atrazine concentration range from 6.7×10?7 to 2.0×10?5 mol L?1, with a limit of detection (LOD) of 1.4×10?7 mol L?1. The proposed electrode was applied for atrazine determination with satisfactory results compared with a high‐performance liquid chromatography method (HPLC).  相似文献   

18.
This paper presents for the first time the use of an environmentally friendly solid bismuth microelectrode for the voltammetric quantification of V(V) in natural water samples. These studies were designed to replace the film bismuth electrode that had been introduced to eliminate the conventional sensors based on highly toxic mercury. In the proposed procedure, V(V) is preconcentrated at the solid bismuth microelectrode surface via the formation of electroactive complexes with cupferron from a solution of 0.1-mol L−1 acetate buffer, pH = 4.6 at a potential of −0.4 V. The linearity of the calibration graph is in the V(V) concentration range from 8 × 10−10 to 1 × 10−7 mol L−1 with a preconcentration time of 1 min. The limit of detection (calculated as 3 σ) is 2.5 × 10−10 mol L−1 for a preconcentration time of 1 min. It was also demonstrated that significant improvement in analytical parameters was achieved as a result of the activation of the solid electrode surface at a potential of −2.5 V for 2 s. The developed procedure is highly selective for the presence of foreign ions and organic compounds in tested samples. The accuracy of the recommended procedure was checked using SPS-WW1 waste water-certified reference materials of a complex composition, in which the concentration of V(V) determined by the proposed method was 95.1 ± 1.6 ng mL−1. Moreover, in keeping with the outlined procedure, river, tap and rain water samples were analyzed without any pretreatment, and recovery values from 96% to 106% were obtained.  相似文献   

19.
《Electroanalysis》2006,18(12):1223-1226
A sensitive catalytic adsorptive stripping voltammetric procedure for determination of traces of total chromium in environmental samples is reported. The method is based on the preconcentration of a Cr(III)? H2DTPA complex by adsorption at the HMDE from an acetate buffer solution at the potential ?1.0 V vs. Ag/AgCl. Total chromium was determined as Cr(III) after reduction of Cr(VI) to Cr(III) by NaHSO3. In order to stabilize the signal of Cr(III) the measurements were performed at 5 °C. The calibration graph for chromium for an accumulation time of 60 s was linear in the range from 5×10?10 to 5×10?8 mol L?1. The relative standard deviation for a chromium concentration of 1×10?8 mol L?1 was 3.9% (n=5). The detection limit for accumulation time of 60 s was about 8×10?11 mol L?1. The validation of the procedure was performed by the analysis of the certified reference materials.  相似文献   

20.
A simple adsorptive cathodic stripping voltammetry method has been developed for antimony (III and V) speciation using 4‐(2‐thiazolylazo) – resorcinol (TAR). The methodology involves controlled preconcentration at pH 5, during which antimony(III) – TAR complex is adsorbed onto a hanging mercury drop electrode followed by measuring the cathodic peak current (Ip,c) at ?0.39 V versus Ag/AgCl electrode. The plot of Ip,c versus antimony(III) concentration was linear in the range 1.35×10?9–9.53×10?8 mol L?1.The LOD and LOQ for Sb(III) were found 4.06×10?10 and 1.35×10?9 mol L?1, respectively. Antimony(V) species after reduction to antimony(III) with Na2SO3 were also determined. Analysis of antimony in environment water samples was applied satisfactorily.  相似文献   