首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 62 毫秒
1.
祁步嘉  唐洪庆  周祖英 《物理》2002,31(1):36-39
采用双飞行时间法创建了一台非常规快中子飞行时间谱仪,排除了用D(d,n)^3He中子源测量8-13MeV能区次级中子双微分截面时源中破裂中子群对次级中子能谱测量的干扰,结合常规快中子飞行时间谱仪的测量,实现了用D(d,n)^3He中子源开展8-13MeV中子能区次级中子双微分截面的测量。  相似文献   

2.
测量了8.17MeV与10.27MeV中子与9Be和6,7Li作用的次级中子双微分截面. 对于10.27MeV, 为了消除从D(d,np)破裂反应来的源破裂中子对双微分截面测量结果的影响, 采用了常规多探测器快中子飞行时间谱仪和非常规多探测器快中子飞行时间谱仪相结合的办法. 用Monte-Carlo方法对实验测量得到的飞行时间谱进行了详细的模拟, 通过测量谱与模拟谱的比较, 得到了实验测量的次级中子双微分截面. 实验测量结果以n-p(常规谱仪)和n-C(非常规谱仪)弹性散射微分截面作为归一. 测量结果与评价数据以及其他测量数据进行了比较. 用一个基于Hauser-Feshbach和激子模型的轻核核反应理论模型对6,7Li的次级中子双微分截面进行了计算, 理论计算结果与实验结果符合得较好.  相似文献   

3.
用中国原子能科学研究院HI13串列加速器上的多探测器快中子飞行时间谱仪, 测量了8.19 MeV中子与9Be作用时, 从20°到160°区间26个角度的次级中子双微分截面。测量截面以np散射截面作为标准进行归一。实验结果用Monte Carlo方法进行了中子注量率衰减、多次散射和有限几何修正, 并用MCNP4C程序对所用的Monte Carlo程序进行了验证。测量结果与评价数据以及其它实验室的数据进行了比较。The secondary neutron emission double differential cross section of 9Be induced by 8.19 MeV neutron was measured at 26 different angles from 20°to 150°by using the multi detector fast neutron TOF spectrometer at the HI 13 Tandem Accelerator at China Institute of Atomic Energy(CIAE). The results were normalized to np scattering measurement. A special Monte Carlo code which was validated with the MCNP 4C code was employed to analyze the measured data for the corrections of neutron flux attenuation, multiple scattering and finite geometry. The measured results were compared with the evaluated data and the other measurements.   相似文献   

4.
5.
厚闪烁体内次级中子对快中子图像质量的影响研究   总被引:1,自引:0,他引:1       下载免费PDF全文
利用编制的快中子照相数值模拟程序(FNRSC)模拟计算了入射中子能量为14 MeV时,厚度5—300 mm闪烁体内次级中子对快中子图像质量的影响,结果表明闪烁体厚度d<50mm时,次级中子对图像的影响强烈依赖于闪烁体厚度,而当d>50 mm时,次级中子对图像的影响趋于饱和.将文献中利用蒙特卡罗中子-光子输运程序(MCNP)计算的次级中子对图像影响和文中计算结果进行了对比,给出了二者存在差异的主要原因:次级中子分布对入射中子空间分布的强烈依赖性;能量沉积和荧光输出这两种计算方法对 关键词: 14 MeV中子 快中子照相 次级中子 Monte Carlo模拟  相似文献   

6.
利用蒙特卡罗程序MCNPX模拟计算了纯聚乙烯球和加入辅助材料的聚乙烯球对不同能量中子的响应函数曲线,使用计算出来的响应函数作为U-M-G软件解谱所需输入文件。研发了一套专门为此多球谱仪进行数据采集的放大甄别一体化电路,该电路可为SP9管提供900 V的工作高压,甄别阈设为0.5 V,总的放大倍数为200倍。使用研制的Bonner球谱仪对已知源强的Pu-Be中子源进行能谱测量,测量结果显示解出的能谱数据与实际Pu-Be源中子能谱较为符合,实验结果验证了该套多球谱仪可用于测量Pu-Be能区的中子谱。Neutron response of Bonner spheres which include pure polyethylene and polyethylene with auxiliary material was calculated with Monte Carlo code MCNPx, the calculated response was used as the input le of U-M-G code for neutronspectrum unfolding. A special screening of ampli cation integrated circuits was developed, which can provides high voltage 900 V working for the SP9 tube, the screening threshold is set to 0.5 V and total magni cation is 200. Neutron energy spectrum of a Pu-Be source were measured with the developed Bonner spheres spectrometer,good agreement was found in the measured result of the spectrum datasolutionand the real spectrum, which indicated that the multi-sphere spectrometer was reliable in the neutron measurement at energy region of Pu-Be neutron source.  相似文献   

7.
非弹性中子散射是利用中子与材料晶格或自旋散射发生能量和动量交换来测量材料动力学性质的实验技术.非弹性中子散射谱仪可以直接测量声子谱、自旋波、晶体场等性质,且能量和动量分辨率高,在物理、材料、化学、生物等领域有广泛应用,是前沿科学研究中重要的实验仪器.本文概述了非弹性中子散射的发展过程、基本理论、散射谱仪及应用范例.  相似文献   

8.
靶单元组件对中子有散射和吸收作用,与入射粒子也会发生反应,因此高压倍加器中子场在空间的分布除了由反应本身的角分布决定外,还受到靶单元组件的影响。实验利用飞行时间法测量了高压倍加器T(d,n)4He 中子源产生的实际中子场,测量角度为0°~95°,共8 个角度,采用伴随 粒子法对入射束流进行归一。借助蒙特卡罗方法模拟实验过程和靶单元组件等对中子场分布的影响,将实验结果同模拟计算得到的结果进行了比较与分析,为高压倍加器相关实验布局的合理布置和靶单元组件的优化提供了一定的依据。The spatial distribution of neutron field for the High Voltage Multiple Accelerator (HVMA) is not only determined by the angular distribution of the reaction itself, but also affected by scattering and absorption of the target unit. Meanwhile, undesired nuclear reactions of the incoming ions with the target and self-target build-up may contribute to this neutron background, which disturbs the primary neutron field. The spatial distribution of actual neutron field generated by T(d, n)4He on HVMA was measured using the flight-time method. The neutron emission energy spectra were measured at 8 different angles from 0° to 95°. The results were monitored by the accompanying-particle method. TARGET and MCNP (Monte Carlo simulation process) programs were used to simulate the experiment. The results of simulated calculation were compared with the experimental data. The analyzed results will give some qualitative and quantitative conclusions for target unit optimizing and provide some foundational works for physical measurement in HVMA.  相似文献   

9.
言杰  刘荣  蒋励  鹿心鑫  朱通华  林菊芳  王玫  温中伟  汪一夫 《物理学报》2011,60(10):102902-102902
基于反冲质子法建立了一种测量D-T中子与平板型宏观样品作用的次级中子角度谱的实验方法.为保证探测器的能量线性并在较低的中子有效测量下阈(0.5 MeV)情况下获得好的中子-伽马射线甄别性能,采用高、低能段分别测量的方法.采用事件记录法,同时记录了次级中子和伴随伽马射线的脉冲形状甄别和脉冲幅度二维信息,利用基于ROOT数据分析平台编写的离线数据分析程序,完成了伴随伽马射线的挑选和扣除,以及高、低两能段反冲质子谱的拼接,并成功的将神经网络技术应用于中子能谱的解谱,获得了D-T中子与9和18 cm厚平板型聚乙烯材料作用的0.5-15 MeV的次级中子角度谱实验结果.实验模型的MC模拟由MCNP5完成,数据库采用ENDF-VI,实验结果和MC计算结果在实验不确定度范围内一致. 关键词: D-T中子 积分中子学 反冲质子法 次级中子能谱  相似文献   

10.
在评价核数据库ENDF VI版的出射粒子能量分布数据(即文档5)中,一些核素在阈能附近的次级中子能量分布大多采用简单的近似方法描述,例如三角形分布或矩形分布.这些简单的近似描述,将导致产生散射矩阵的"双峰"现象,或使平均次级中子能量过大而产生负KERMA(ki netic energy release in materials)因子.针对这两个现象,通过细致的分析,讨论了这些现象的产生原因,并试对相关数据做一定的修正,以改善次级中子分布的能量守恒问题. In file 5 of ENDF VI, the arbitrary tabulated function (L=1) was applied to some threshold reactions of some nuclides. The energy distribution of secondary spectrum was given approximately as a triangular shape or rectangular shape at the threshold energy for some nuclides. The triangular shape distributions would cause two peaked energy distribution near the threshold energy, which must affect the group transfer matrix. The rectangular shape make the E′n too large, that may lead to...  相似文献   

11.
介绍了在实验室中测大电阻的一种方法。依据欧姆定律,并利用灵敏电流计测出数据。被测电阻的实测结果标准误差小于003MΩ,相对误差小于1%。  相似文献   

12.
提出了中子单色化的新想法,并从理论上给出了具体的处理方法.以石墨、硅及锗为例演示了新方法的应用,并得到满意结果.将新方法与三组双晶法作了比较,二者效果相差无几,但是新方法简单易行且节省费用 关键词:  相似文献   

13.
给出测量金属线胀系数的一种新方法。本文根据夫琅和费衍射原理,利用CCD来测量金属体随温度升高的伸长量,对黄铜的线胀系数进行了测量。  相似文献   

14.
本文分析了用衍射光栅测量光波波长和光栅常数的实验原理和数据处理方法:提出了用比较法测量光波波长、用最小二乘法计算光栅常数的新方法。  相似文献   

15.
测定金属热膨胀系数的新方法研究   总被引:3,自引:0,他引:3  
分析了用光杠杆法测量金属线膨胀系数α实验中存在的主要问题.提出采用劈尖干涉法改进的测量方法。  相似文献   

16.
提出一种利用谱编辑的方法来简化二维谱的探测,使得一张二维谱可以被简化为N条一维谱(N等于二维谱中F1维上的谱线总数),从而达到缩短数据采集时间和减少数据贮存空间的目的。文中给出了运用此方法探测二维碳氢异核相关实验的实例,并分析了由于F1维的谱线不为δ函数而产生的编辑误差的大小,最后将此方法推广到三维的简化探测,即通过对N张二维谱的编辑获得三维谱的信息。  相似文献   

17.
提高腔靶激光能量注入率的新途径   总被引:2,自引:2,他引:0       下载免费PDF全文
 在“星光Ⅱ”上测量了入射孔边缘镀CH膜的孔靶激光能量注入率,给出了注入率随入射激光能量和波长变化的经验公式,同时对堵口现象物理机理进行了一维数值模拟。实验结果表明:镀CH膜是增加激光能量注入率、提高腔靶辐射温度的有效方法。  相似文献   

18.
提出软X光能谱仪的一种新的解谱方法即最大熵法,运用新的平滑方法即样条拟合方法处理滤片的边带结构,并对最大熵法的收敛性和稳定性进行了分析.结果表明,该方法的谱回推精度高,收敛速度快且对噪声不很敏感.该方法适用于根据软X光能谱仪的测量结果回推靶等离子体的软X光谱.  相似文献   

19.
郭敏 《物理》2001,30(4):220-222
文章报道了一种测量液体粘滞系数的新方法-微机控制超声多普勒法,它将超声技术与计算机技术相结合,利用超声多普勒效应接收液体中下落小球的频移信号,将此信号送微机进行采集、比较、判断、计算并出粘滞系数,应用本方法能快速准确地测量多种液体的粘滞系数。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号