1.

Purpose

The aim of this study was to determine the adequate MR sequence for the lesion conspicuity of hepatocellular lesions with increased iron uptake on superparamagnetic iron oxide (SPIO)-enhanced MRI.

Materials and Methods

SPIO-enhanced MRI was performed using a 1.5-T system. Among 25 patients with hypovascular hepatocellular nodules on contrast-enhanced dynamic CT (no early enhancement at arterial phase and hypoattenuation at equilibrium phase), 39 lesions with increased iron uptake on SPIO-enhanced MRI were evaluated. SPIO-enhanced MRI included (1) T1-weighted in-phase gradient recalled echo (GRE) images, (2) T2-weighted fast spin echo (FSE) images, (3) T2*-weighted GRE with moderate TE (7 ms) and (4) long TE (12 ms). The lesion-to-liver contrast-to-noise ratios of the hepatocellular nodule and the signal-to-noise ratio (SNR) of the hepatic parenchyma were calculated by one radiologist for a quantitative assessment. MR images were reviewed retrospectively by two independent radiologists to compare the subjective lesion conspicuity in each image set based on a four-point rating scale.

Result

The mean lesion-to-liver contrast-to-noise ratios with T2*-weighted GRE with moderate TE (7 ms) was highest (5.79±3.71) and was significantly higher than those with T1-weighted, in-phase images (3.79±3.23, P<.01), T2-weighted images (2.72±1.52, P<.001) and T2*-weighted GRE with long TE (12 ms) (3.93±2.69, P<.05). The subjective rating of lesion conspicuity was best on the T2*-weighted GRE with moderate TE (7 ms), followed by that on the T2*-weighted GRE with moderate TE (7 ms; P<.05).

Conclusion

T2*-weighted GRE sequence with moderate TE (7 ms) showed high lesion-to-liver contrast-to-noise ratios in hepatocellular lesions with increased iron uptake on SPIO-enhanced MRI, indicating better lesion conspicuity of hypointense hepatocellular nodules in cirrhosis or chronic hepatitis.  相似文献   

2.
The purpose of this study was to evaluate the ability of three dimensional T1-weighted multi-shot Echo Planar Imaging (3D T1w EPI) MR pulse sequence to provide comparable to T1w Spin Echo (SE) results in various diseases of the brain, during shorter acquisition times. Thirty-six patients (aged 30-74 years) with various indications were included in the study. All examinations were performed with a 1T MR scanner with a maximum gradient strength of 15 mT/m. The SE sequence lasted 3 min 50s and the 3D T1w EPI 59s. The quantitative analysis included number of enhancing lesions, signal-to-noise ratio of the enhancing lesions and contrast-to-noise ratio (CNR) between enhancing lesions and white matter in both sequences before and after i.v. administration of 0.1 mmol/kg gadopentetate dimeglumine. In addition, the percentage increase of enhancement was measured in each lesion of each sequence. The qualitative analysis included a) conspicuity of the lesions and b) presence of artifacts. The T1w SE sequence was significantly better compared to 3D T1w EPI in all quantitative measurements with the exception of CNR of enhancing lesions before contrast administration and the percentage enhancement. The conspicuity of the lesions did not differ between the two sequences. The EPI sequence presented with significantly more artifacts. We conclude that the 3D T1w EPI sequence could not be used instead of the conventional T1w SE, in routine imaging of the brain. Its overall diagnostic capability, could be useful only in uncooperative patients.  相似文献   

3.
The purpose of our study was to assess whether respiratory-triggered multishot fast spin echo (MS-FSE) and breath-hold half-Fourier single-shot fast spin echo (SS-FSE) images, in addition to breath-hold T(2)*-weighted gradient recalled echo (GRE) images, increase observer performance in the detection of malignant hepatic tumors with ferumoxide-enhanced magnetic resonance (MR) imaging. Ferumoxide-enhanced MR images obtained from 48 patients with 83 malignant hepatic tumors were retrospectively reviewed by three independent off-site readers. In the first image review, GRE images alone were reviewed. Then, MS-FSE images were added for the first combination review. Finally, SS-FSE images were added for the second combination review. Observer performances were tested by McNemar's test and receiver-operating-characteristic analysis for the clustered data. Sensitivity for hepatocellular carcinomas, metastases, and malignant hepatic tumors overall was significantly (p < 0.05) higher with GRE and MS-FSE combined and GRE, MS-FSE and SS-FSE combined than with GRE alone. For metastases, the Az value was significantly (p < 0.05) higher with GRE and MS-FSE combined, and GRE, MS-FSE and SS-FSE combined than with GRE alone. We confirmed the incremental value of ferumoxide-enhanced MR imaging by obtaining MS-FSE and SS-FSE images in addition to GRE images in the detection of malignant hepatic tumors.  相似文献   

4.
We report a case of multiple hemorrhagic cerebral metastases from papillary thyroid cancer, with reference to T(2)*-weighted gradient echo (GRE) magnetic resonance imaging (MRI). Small metastatic nodules were recognized as round nodules with signal loss on T(2)*-weighted GRE MRI, and were more pronounced compared with other sequences. Lesions were later confirmed as hemorrhagic on T(1)- and T(2)-weighted MRI. T(2)*-weighted GRE MRI was a sensitive tool for early detection of metastases displaying hemorrhagic changes.  相似文献   

5.
The purpose of this study was to develop a multi-shot dual-echo breathhold fast spin echo technique (DFSE) and compare it with conventional spin echo (T2SE) for T(2)-weighted MR imaging of liver lesions. The DFSE acquisition (EffTE1/EffTE2/TR = 66/143/2100 ms) imaged 5 sections per 17 s breathhold. T2SE imaging (TE1/TE2/TR = 60/120/2500 ms) required 16:55 (min:s) for 14 sections. Both techniques used a receive-only phased-array abdominal multicoil and provided 192 x 256 effective resolution. The results showed first and second echo relative DFSE/T2SE contrast values for 27 representative lesions (15 consecutive patients) were 1.08 +/- 0.05 and 1.16 +/- 0.09 (mean +/- STD mean), respectively. Corresponding CNR values were 1.12 +/- 0.09 and 0.97 +/- 0.12. Overall DFSE was comparable-to-superior to T2SE for lesion sizing and image artifact. DFSE lesion detection was inferior to T2SE's in several patient studies because of decreased conspicuity of lesions located near multicoil edges and because of poor breathhold-to-breathhold reproducibility and lack of breathholding. However both DFSE (and T2SE) provided lesion detection rated to be of diagnostic quality for all patient studies. In conclusion, we found that DFSE provides diagnostically useful dual-echo T(2)-weighted MR liver images in a greatly decreased acquisition time.  相似文献   

6.
Optimal angle, fast repeat time, gradient field echo imaging techniques such as FISP (Fast Imaging with Steady Precession) and FLASH (Fast Low Angle Shot) often fail to discriminate disease from healthy tissue for two main reasons. First, T1 and T2 of the affected tissue may increase such that the ratio of T1 to T2 remains nearly unchanged, hence there is no contrast change with FISP. Second, T2 weighted gradient field echo images suffer severely from T2* signal and resolution loss leading to a reduction in C/N. Although FLASH imaging with two separate angles can, in principle, extract the longer T1 tumors, contrast is often not good. To overcome the inhomogeneity and contrast problems, we have implemented a FAst optimal angle spin-echo sequence with a short TE(FATE). For the first echo, FATE has the same contrast properties as FLASH with a slight decrease in signal intensity. The advantage is that the intensity of the signal does not suffer from T2* signal decay, hence improved contrast and disease detection via T2 weighted FATE images is possible. Contrast-to-noise in lesion detection is also considered for CE FAST (Contrast Enhanced Fast), a T2-weighted version of FISP, and HYBRID.  相似文献   

7.
The purpose of this study was to compare the diagnostic efficacy of single shot fast spin echo sequence (SSh-FSE), and single shot GRASE-sequence (SSh-GRASE) to the conventional T(2)-weighted fast spin echo-sequence (T(2)-FSE) in the imaging of brain disorders. Thirty three patients with high signal intensity lesions on T(2)-weighted images (n = 28), or intracerebral hemorrhage (n = 5), were examined on a 1.0 T MR scanner, with 23 mT/m gradient strength. The scan time for the conventional T(2)-FSE-sequence was 2 min 57 s, the scan time for the single shot-FSE-, and single shot-GRASE-sequences was 11 sec, and 17 sec, respectively. Twenty-one patients remained still during the examination, whereas 12 could not stay still with consecutive marked motion artifacts. Images were reviewed by three radiologists. Lesion conspicuity, image quality, and artifacts were scored on a subjective scale. Signal-to-noise ratios of lesions and normal tissue and contrast-to-noise ratios (CNR) were measured by region of interest (ROI). In the patient group without motion artifacts conspicuity for lesions > or =5 mm did not show a significant difference on conventional T(2)-FSE, single shot-FSE and single shot-GRASE. Detectability of the smaller lesions was significantly inferior on single shot-FSE-, and single shot-GRASE-sequences in artifact free images. For the patient group with motion artifacts SSh-FSE and SSh-GRASE were markedly superior to the conventional T(2)-FSE. Grey-white differentiation was better on conventional T(2)-FSE. Physiologic ferritin as well as pathologic hemosiderin depositions were slightly darker and therefore better visible on SSh-GRASE than on SSh-FSE. Conventional T(2)-FSE showed significantly more artifacts. In conclusion, SSh-FSE and SSh-GRASE imaging can be used for rapid imaging of the brain in those patients who are claustrophobic or in patients with involuntary movements due to extrapyramidal disorders, as well as in children in whom anesthesia is contraindicated or sedation is not possible.  相似文献   

8.
PurposeTo evaluate the use of the double-echo steady-state (DESS) sequence for acquiring high-resolution breast images with diffusion and T2 weighting.Materials and MethodsPhantom scans were used to verify the T2 and diffusion weighting of the DESS sequence. Image distortion was evaluated in volunteers by comparing DESS images and conventional diffusion-weighted images (DWI) to spoiled gradient-echo images. The DESS sequence was added to a standard clinical protocol, and the resulting patient images were used to evaluate overall image quality and image contrast in lesions.ResultsThe diffusion weighting of the DESS sequence can be easily modulated by changing the spoiler gradient area and flip angle. Radiologists rated DESS images as having higher resolution and less distortion than conventional DWI. Lesion-to-tissue contrast ratios are strongly correlated between DWI and DESS images (R = 0.83) and between T2-weighted fast spin-echo and DESS images (R = 0.80).ConclusionThe DESS sequence is able to acquire high-resolution 3D diffusion- and T2-weighted images in short scan times, with image quality that facilitates morphological assessment of lesions.  相似文献   

9.
In this study, the volume of susceptibility artifact was evaluated in T1 and T2-weighted spin echo (SE) and gradient echo (GRE) images at various parameters using registration and subtraction methods. In order to state an important misinterpretation problem in lymphography, it was demonstrated that a lymph node size may be enlarged approximately 10 times when a T2*-weighted GRE protocol is used. To overcome this problem a technical consideration using multisequence (GRE and SE) paradigm was suggested to ensure both lymph node detection and metastasis identification in lymphatic system. The paradigm was also extended by post-processing manipulation of the SE images using a registration and subtraction approach for detection of lymphatic lesions.  相似文献   

10.
The purpose of this study is to quantitatively compare the image quality and efficiency provided by widely available fast MR imaging pulse sequences. A composite phantom with various T1 and T2 values and subjected to periodic motion was imaged at 1.5 T. The fast MRI sequences evaluated included fast spin-echo (FSE), single shot fast spin-echo (SSFSE), echo-planar imaging (EPI), multi-slice gradient recalled (MPGR), fast MPGR (FMPGR), and fast multi-slice spoiled gradient echo (FMPSPGR). T1-weighted (T1WI), T2-weighted (T2WI), proton-density-weighted (PDWI), and T2*-weighted (T2*WI) images were evaluated in breath-hold and non-breath-hold time frames. Analysis included measurement of image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), nonuniformity, ghosting ratio, SNR per unit time and CNR per unit time. Among fast T2WI sequences, FSE with breath-hold time frame resulted in the highest image quality and in superior SNR and CNR efficiency by a factor of 5 or 6 as compared with conventional spin echo sequence. Among fast T1WI sequences, FMPGR and FMPSPGR both with non-breath-hold time frame produced the highest image quality and SNR and CNR efficiency by a factor of greater than 5 as compared with conventional spin echo. Among fast PDWI and T2*WI sequences, FSE produced the highest SNR and CNR, and was maximally efficient with a factors of greater than 6 as compared with conventional spin echo.  相似文献   

11.
There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was generated with acquisitions using dual echo 3D UTE with echo subtraction, dual echo 3D UTE with rescaled subtraction, long T2 saturation 3D UTE, long T2 saturation dual echo 3D UTE with echo subtraction, single adiabatic inversion recovery 3D UTE, single adiabatic inversion recovery dual echo 3D UTE with echo subtraction and dual adiabatic inversion recovery 3D UTE. The feasibility of using these approaches was demonstrated in in vitro and in vivo imaging of calcified cartilage, aponeuroses, menisci, tendons, ligaments and cortical bone with a 3-T clinical MR scanner. Signal-to-noise ratios and contrast-to-noise ratios were used to compare the techniques.  相似文献   

12.
We introduce an accelerated gradient echo (GRE) sequence combining simultaneous multislice excitation (SMS) with echo-shifting technique for high spatial resolution blood oxygen level dependent (BOLD) functional MRI (fMRI). The simulation was conducted to optimize scan parameters. To validate the feasibility of the proposed technique, the visual and motor task experiments were performed at 7.0 Tesla (T). The single-shot EPI sequence was also applied in comparison with the proposed technique. The simulation results showed that an optimized flip angle of 9° provided maximal BOLD contrast for our scanning scheme, allowing low power deposition and SMS acceleration factor of 5. Additionally, parallel acquisition imaging with acceleration factor of 2 was utilized, which allowed a total acceleration factor of 10 in volunteer study. The experiment results showed that geometric distortion-free BOLD images with voxel size of 1.0 × 1.0 × 2.5 mm3 were obtained. Significant brain activation was identified in both visual and motor task experiments, which were in accordance with previous investigations. The proposed technique has potential for high spatial resolution fMRI at ultra-high field because of its sufficient BOLD sensitivity as well as improved acquisition speed over conventional GRE-based techniques.  相似文献   

13.
In gradient echo imaging the in-plane susceptibility gradient causes an echo shift which results in signal loss. The loss of signal becomes more severe in gradient echo EPI, due to the low amplitude of the gradient which is applied in the phase-encoding direction during a long echo train. As the readout gradient amplitude is set to be very high in gradient echo EPI, the echo shift in the readout direction is negligible compared to that in the phase-encoding direction. Traditionally, a z-shimming technique has been applied to the phase-encoding direction of gradient echo EPI to restore the lost signal. This technique, however, requires a significant increase of scan time, as is also the case with the through-plane z-shimming technique. A new approach that allows one to restore the lost signal is to acquire additional phase-encoding lines beyond the regular phase-encoding range. The extension of the phase-encoding lines prior to the regular phase-encoding range exploits the delay time for optimum echo time of the BOLD sensitivity. Therefore, scan time is increased only for the extended phase-encoding lines posterior to the regular phase-encoding range. This technique has been confirmed experimentally by imaging human subject's heads at 3T.  相似文献   

14.
PurposeTo implement a fast (~ 15 min) MRI protocol for carotid plaque screening using 3D multi-contrast MRI sequences without contrast agent on a 3 Tesla MRI scanner.Materials and methods7 healthy volunteers and 25 patients with clinically confirmed transient ischemic attack or suspected cerebrovascular ischemia were included in this study. The proposed protocol, including 3D T1-weighted and T2-weighted SPACE (variable-flip-angle 3D turbo spin echo), and T1-weighted magnetization prepared rapid acquisition gradient echo (MPRAGE) was performed first and was followed by 2D T1-weighted and T2-weighted turbo spin echo, and post-contrast T1-weighted SPACE sequences. Image quality, number of plaques, and vessel wall thicknesses measured at the intersection of the plaques were evaluated and compared between sequences.ResultsAverage examination time of the proposed protocol was 14.6 min. The average image quality scores of 3D T1-weighted, T2-weighted SPACE, and T1-weighted magnetization prepared rapid acquisition gradient echo were 3.69, 3.75, and 3.48, respectively. There was no significant difference in detecting the number of plaques and vulnerable plaques using pre-contrast 3D images with or without post-contrast T1-weighted SPACE. The 3D SPACE and 2D turbo spin echo sequences had excellent agreement (R = 0.96 for T1-weighted and 0.98 for T2-weighted, p < 0.001) regarding vessel wall thickness measurements.ConclusionThe proposed protocol demonstrated the feasibility of attaining carotid plaque screening within a 15-minute scan, which provided sufficient anatomical coverage and critical diagnostic information. This protocol offers the potential for rapid and reliable screening for carotid plaques without contrast agent.  相似文献   

15.
The main objective of this article was (i) to refocus the residual dipolar and quadrupolar interactions in anisotropic tissues employing magic sandwich echo (MSE) imaging and to compare the results with that of conventional spin-echo (SE) imaging, and (ii) to quantify MSE relaxation and dispersion characteristics in bovine Achilles tendon and compare with spin-lattice relaxation time constant in the rotating frame (T(1rho)). Magic sandwich echo weighted images are approximately 75-100% higher in signal-to-noise ratio than the corresponding T(2)-weighted images. Magic sandwich echo relaxation times varied from 13+/-2 to 19+/-3 ms (mean+/-S.D.), depending upon the structural location of tendon. T(2) relaxation times only varied from 4+/-1 to 10+/-3 ms (mean+/-S.D.) on the same corresponding locations. Magic sandwich echo provides approximately 100% enhancement in relaxation times compared to T(2). Preliminary results based on bovine Achilles tendon and cartilage specimens suggest that the MSE technique has potential for refocusing residual dipolar as well as quadrupolar interactions in anisotropic systems and yields higher intensities than conventional SE imaging as well as T(1rho)-encoded imaging, especially at low-burst pulse amplitudes (250 and 500 Hz).  相似文献   

16.
The 3D fast asymmetric spin echo (FASE) method combines the half-Fourier technique and 3D fast spin echo (FSE) sequence. The advantage of this method is that it maintains the same spatial resolution as FSE while markedly reducing the imaging time. The purpose of the present study was to evaluate the usefulness of the 3D FASE technique in displaying the inner ear structure using phantom and volunteer studies. 3D FSE sequence images were obtained for comparison, and the optimum 3D FASE sequence was investigated on a 1.5T MR scanner. The results of phantom experiments showed increased signal-to-noise ratio (SNR) with prolonging repetition time (TR) on both 3D FASE and 3D FSE sequences. Although the SNR of 3D FASE images was 20-25% lower than that of 3D FSE images with the same TR, the SNR per minute with 3D FASE was about twice that with 3D FSE. On 3D FASE images, a higher spatial resolution was obtained with 2- or 4-shot images than with single-shot images. However, no significant difference was observed between 2-shot and 4-shot images. In the volunteer study, 3D FASE images using a TR of 5000 ms and an effective echo time (TEeff) of 250 ms showed a high SNR and spatial resolution and provided excellent contrast between cerebrospinal fluid and nerves in the internal auditory canal. The highest contrast was achieved in the 2-shot/2 number of excitations sequence. 3D FASE provides the same image quality as 3D FSE with a significant reducing in imaging time, and gives strong T2-weighted images. This method enables detailed visualization of the tiny structures of the inner ear.  相似文献   

17.
The aim of this study was to determine the value of a fat suppressed 3D gradient-echo sequence (GRE) data set in comparison to a 2D GRE sequence in direct MR arthrography of the shoulder. For this purpose we examined 50 consecutive patients with subacute or chronic disorders of the shoulder using a 1.5 T scanner: Transverse T1-weighted 2D (slice thickness 4 mm) and 3D GRE (slice thickness 1.5 mm reconstructed from 3 mm), oblique coronal T2- and T1-weighted turbo spin-echo (TSE) and sagittal T1-weighted TSE with fat saturation were applied. Visual image analysis of anatomical and pathological structures was performed by two independent observers. A correlation to surgical results was available in 21 patients. Transverse GRE sequences were well suited for analysis of the anterior/posterior labrum, the middle glenohumeral ligament, and cartilage. 3D GRE with fat suppression was slightly superior to 2D GRE without fat suppression in the evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament, whereas for cartilage no significant differences were found between both sequences. Concerning pathological findings, in most of the cases 2D delivered the same results as 3D. In conclusion, a T1-weighted 3D GRE data set with fat saturation in transverse orientation may be useful for evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament. However, similar measured slice thickness of 3 mm-even if interpolated to 1.5 mm-compared to a 2D sequence with 4 mm does not provide significant diagnostic advantages.  相似文献   

18.
PurposeTo evaluate the accuracy of susceptibility estimated from the principles of echo shifting with a train of observations (PRESTO) sequence using a 1.5 T MRI system, we conducted experiments on the human brain using the PRESTO sequence and compared our results with the susceptibility obtained from spoiled gradient-recalled echo (GRE) sequence with flow compensation using quantitative susceptibility mapping (QSM) reconstruction.Materials and methodsExperiments on the human brain were conducted on 12 healthy volunteers (27 ± 4 years) using PRESTO and spoiled GRE sequences on a 1.5 T scanner. The PRESTO sequence is an echo-shifted gradient echo sequence that allows high susceptibility sensitivity and rapid acquisition because of TE > TR compared with the spoiled GRE sequence. QSM analysis was performed on the obtained phase images using the iLSQR method. Estimated susceptibility maps were used for region of interest analyses and estimation of line profiles through iron-rich tissue and major vessels.ResultsOur results demonstrated that susceptibility maps were accurately estimated, without error, by QSM analysis of PRESTO and spoiled GRE sequences. Acquisition time in the PRESTO sequence was reduced by 43% compared with that in the spoiled GRE sequence. Differences did exist between susceptibility maps in PRESTO and spoiled GRE sequences for visualization and quantitative values of major blood vessels and the areas around themConclusionThe PRESTO sequence enables correct estimation of tissue susceptibility with rapid acquisition and may be useful for QSM analysis of clinical use of 1.5 T scanners.  相似文献   

19.
A new pulse sequence for high-resolution T2-weighted (T2-w) imaging is proposed — image domain propeller fast spin echo (iProp-FSE). Similar to the T2-w PROPELLER sequence, iProp-FSE acquires data in a segmented fashion, as blades that are acquired in multiple TRs. However, the iProp-FSE blades are formed in the image domain instead of in the k-space domain. Each iProp-FSE blade resembles a single-shot fast spin echo (SSFSE) sequence with a very narrow phase-encoding field of view (FOV), after which N rotated blade replicas yield the final full circular FOV. Our method of combining the image domain blade data to a full FOV image is detailed, and optimal choices of phase-encoding FOVs and receiver bandwidths were evaluated on phantom and volunteers. The results suggest that a phase FOV of 15–20%, a receiver bandwidth of ± 32–63 kHz and a subsequent readout time of about 300 ms provide a good tradeoff between signal-to-noise ratio (SNR) efficiency and T2 blurring. Comparisons between iProp-FSE, Cartesian FSE and PROPELLER were made on single-slice axial brain data, showing similar T2-w tissue contrast and SNR with great anatomical conspicuity at similar scan times — without colored noise or streaks from motion. A new slice interleaving order is also proposed to improve the multislice capabilities of iProp-FSE.  相似文献   

20.
Gradient recalled echo (GRE) images are sensitive to both paramagnetic deoxyhaemoglobin concentration (via T2*) and flow (via T1*). Large GRE signal intensity increases have been observed in subcutaneous tumors during carbogen (5% carbon dioxide, 95% oxygen) breathing. We term this combined effect flow and oxygenation-dependent (FLOOD) contrast. We have now used both spin echo (SE) and GRE images to evaluate how changes in relaxation times and flow contribute to image intensity contrast changes. T1-weighted images, with and without outer slice suppression, and calculated T2, T2* and "flow" maps, were obtained for subcutaneous GH3 prolactinomas in rats during air and carbogen breathing. T1-weighted images showed bright features that increased in size, intensity and number with carbogen breathing. H&E stained histological sections confirmed them to be large blood vessels. Apparent T1 and T2 images were fairly homogeneous with average relaxation times of 850 ms and 37 ms, respectively, during air breathing, with increases of 2% for T1 and 11% for T2 during carbogen breathing. The apparent T2* over all tumors was very heterogeneous, with values between 9 and 23 ms and localized increases of up to 75% during carbogen breathing. Synthesised "flow" maps also showed heterogeneity, and regions of maximum increase in flow did not always coincide with maximum increases in T2*. Carbogen breathing caused a threefold increase in arterial rat blood PaO2, and typically a 50% increase in tumor blood volume as measured by 51Cr-labelled RBC uptake. The T2* increase is therefore due to a decrease in blood deoxyhaemoglobin concentration with the magnitude of the FLOOD response being determined by the vascular density and responsiveness to blood flow modifiers. FLOOD contrast may therefore be of value in assessing the magnitude and heterogeneity of response of individual tumors to blood flow modifiers for both chemotherapy, antiangiogenesis therapy in particular, and radiotherapy.  相似文献   