共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Diffusion-weighted MRI in prostate cancer -- comparison between single-shot fast spin echo and echo planar imaging sequences 总被引:1,自引:0,他引:1
Diffusion-weighted (DW) MRI at 1.5 T was carried out in two groups of patients. MRI data were correlated with the biopsy and histopathology (where available). The performance of two sequences -- a single-shot FSE (14 patients) and a single-shot EPI (15 patients) -- was compared. Average ADC values from the normal peripheral zone (PZ), central gland (CG) and the tumour [prostate carcinoma (PCa)] were calculated from b values of 0 and 600. Tukey-Kramer test was used for statistical analysis. EPI produced higher values of ADC (10(-3) mm(2)/s) than FSE sequence: 1.992+/-0.208 vs. 1.573+/-0.270 in PZ (P<.001), 1.518+/-0.126 vs. 1.373+/-0.179 in CG and 1.214+/-0.254 vs. 0.993+/-0.158 in PCa (P<.01). In conclusion, both EPI and FSE sequences showed differences in ADC between normal PZ, CG and PCa; however, EPI produced significantly higher ADC values than FSE. 相似文献
3.
《Magnetic resonance imaging》1997,15(4):405-414
The purpose of this study was to compare the gradient spin-echo (GRASE) to the fast spin-echo (FSE) implementation of fast fluid-attenuated inversion recovery (FLAIR) sequences for brain imaging. Thirty patients with high signal intensity lesions on T2-weighted images were examined on a 1.5 T MR system. Scan time-minimized thin-section FLAIR-FSE and FLAIR-GRASE sequences were obtained and compared side by side. Image assessment criteria were lesion conspicuity, contrast between different types of normal tissue, image quality, and artifacts. In addition, contrast ratios and contrast-to-noise ratios were determined. Compared to FSE, the GRASE technique allowed a 17% reduction in scan time but conspicuity of small lesions in particular was significantly lower on FLAIR-GRASE images because of higher image noise and increased artifacts. Gray-white differentiation was slightly worse on FLAIR-GRASE. Physiological ferritin deposition appeared slightly darker on FLAIR-GRASE images and susceptibility artifacts were stronger. Fatty tissue was less bright with FLAIR-GRASE. With current standard hardware equipment, the GRASE technique is not an adequate alternative to FSE for the implementation of fast FLAIR sequences in routine clinical MR brain imaging. 相似文献
4.
5.
《Magnetic resonance imaging》1996,14(9):1113-1116
Diagnostic difficulties in discriminating brain abscess from necrotic or cystic tumors using conventional CT and MRI have been reported. In this article, we examine the diagnostic ability of diffusion-weighted imaging to discriminate brain abscess from necrotic or cystic tumors. In previous reports, necrotic or cystic tumors show low signal intensity in diffusion-weighted imaging, indicating a high apparent diffusion coefficient (ADC). In contrast, in our study, high signal intensity was observed in the abscess fluid, associated with low ADC. 相似文献
6.
A rapid version of PEPI (pi-echo planar imaging) velocimetry has been implemented, enabling a velocity image, at microscopic resolution, to be acquired in less than 1 s. The velocity map was reconstructed using the phase information from the ratio of two PEPI images, one obtained with a velocity-encoding filter applied prior to the imaging sequence and the other image without. The acquisition time for each image was about 80 ms and the two complete image acquisitions were acquired in one shot in 500 ms. This rapid velocimetry sequence gave a good representation of laminar pipe flow. It has also been used to examine extensional flow in a biaxial extension in which the transient extension takes about 3 s. 相似文献
7.
Multi-echo spiral and echo-planar (EPI) imaging sequences were compared in functional imaging experiments at 3 Tesla. Both sequence types allow calculation of the effective transversal relaxation time T(2)* and the initial signal intensity I(0). These parameters can be used in evaluation of the functional signal with respect to inflow effects and other vascular sources. Prior to functional magnetic resonance imaging (fMRI) experiments T(2)* measurements in the human brain were performed with single- and multi-echo FLASH (fast low angle shot) and compared with EPI und spiral imaging sequences. These experiments resulted in T(2)* values ranging from 42.9 to 53.8 ms in a ROI including white and gray matter and CSF in a prefrontal brain region, and allowed validation of the quantitative results of the fast single-shot techniques. In functional experiments with motor stimulation mean absolute T(2)* increases during stimulation of 1.1 +/- 0.6 ms and 1.4 +/- 0.9 ms were found with multi-echo EPI and spiral imaging, respectively, averaged over the activated pixels. In addition, absolute T(2)* values and the size of activated areas obtained with both sequences are comparable. In these investigations spiral imaging allowed higher spatial resolution due to more efficient use of available gradient performance. 相似文献
8.
9.
Cervical spine MR imaging using multislice gradient echo imaging: comparison with cardiac gated spin echo 总被引:2,自引:0,他引:2
M V Kulkarni P A Narayana C B McArdle J W Yeakley N F Campagna F W Wehrli 《Magnetic resonance imaging》1988,6(5):517-525
Forty-one patients with suspected cervical spine disorders were studied using multislice gradient echo imaging (GE) technique, with a 1.5-T system. The images were compared to cardiac-gated spin echo (CGSE) images in the diagnosis of suspected cord and spinal disorders. Images were graded for ability to detect cord lesion, cord-CSF contrast, CSF-bone contrast and contrast between CSF and extradural abnormality. The signal-to-noise ratio and contrast-to-noise ratio were used to compare images. There was 44% decrease in contrast between cord lesion and normal cord on GE when compared to CGSE, except for spinal cord hemorrhage. There was a 40% improvement between bone and CSF contrast on GE compared to CGSE. GE images were significantly better qualitatively as well as quantitatively in the detection of extradural lesions. This effect was more marked in axial plane where CGSE images are extremely suboptimal. CGSE images are better than GE for spinal cord lesions, while GE are superior in the diagnosis of degenerative disease in the cervical spine. 相似文献
10.
11.
Carlsson A Starck G Ljungberg M Ekholm S Forssell-Aronsson E 《Magnetic resonance imaging》2006,24(9):1179-1185
Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imaging for the determination of magnetic susceptibility of materials. J Magn Reson 1996; Series B(112):111-118] was improved to facilitate sensitive in-house measurements of different phantom materials so that such artifacts can more easily be minimized. Using standard MRI protocols and distilled water as reference, we measured magnetic volume susceptibility differences with a clinical MR system. Two imaging techniques, echo planar imaging (EPI) and spin echo, were compared using liquid samples whose susceptibilities were verified by MR spectroscopy. The EPI sequence has a very narrow bandwidth in the phase-encoding direction, which gives an increased sensitivity to magnetic field inhomogeneities. All MRI measurements were evaluated in two ways: (1) manual image analysis and (2) model fitting. The narrow bandwidth of the EPI made it possible to detect very small susceptibility differences (equivalent susceptibility difference, Deltachi(e)> or =0.02 ppm), and even plastics could be measured. Model fitting yielded high accuracy and high sensitivity and was less sensitive to other image artifacts as compared with manual image analysis. 相似文献
12.
PurposeTo evaluate the feasibility of 3D fast spin-echo (FSE) imaging with compressed sensing (CS) for the assessment of shoulder.Materials and methodsTwenty-nine patients who underwent shoulder MRI including image sets of axial 3D-FSE sequence without CS and with CS, using an acceleration factor of 1.5, were included. Quantitative assessment was performed by calculating the root mean square error (RMSE) and structural similarity index (SSIM). Two musculoskeletal radiologists compared image quality of 3D-FSE sequences without CS and with CS, and scored the qualitative agreement between sequences, using a five-point scale. Diagnostic agreement for pathologic shoulder lesions between the two sequences was evaluated.ResultsThe acquisition time of 3D-FSE MRI was reduced using CS (3 min 23 s vs. 2 min 22 s). Quantitative evaluations showed a significant correlation between the two sequences (r = 0.872–0.993, p < 0.05) and SSIM was in an acceptable range (0.940–0.993; mean ± standard deviation, 0.968 ± 0.018). Qualitative image quality showed good to excellent agreement between 3D-FSE images without CS and with CS. Diagnostic agreement for pathologic shoulder lesions between the two sequences was very good (κ = 0.915–1).ConclusionsThe 3D-FSE sequence with CS is feasible in evaluating the shoulder joint with reduced scan time compared to 3D-FSE without CS. 相似文献
13.
Optimal angle, fast repeat time, gradient field echo imaging techniques such as FISP (Fast Imaging with Steady Precession) and FLASH (Fast Low Angle Shot) often fail to discriminate disease from healthy tissue for two main reasons. First, T1 and T2 of the affected tissue may increase such that the ratio of T1 to T2 remains nearly unchanged, hence there is no contrast change with FISP. Second, T2 weighted gradient field echo images suffer severely from T2* signal and resolution loss leading to a reduction in C/N. Although FLASH imaging with two separate angles can, in principle, extract the longer T1 tumors, contrast is often not good. To overcome the inhomogeneity and contrast problems, we have implemented a FAst optimal angle spin-echo sequence with a short TE(FATE). For the first echo, FATE has the same contrast properties as FLASH with a slight decrease in signal intensity. The advantage is that the intensity of the signal does not suffer from T2* signal decay, hence improved contrast and disease detection via T2 weighted FATE images is possible. Contrast-to-noise in lesion detection is also considered for CE FAST (Contrast Enhanced Fast), a T2-weighted version of FISP, and HYBRID. 相似文献
14.
15.
Bydder M Yokoo T Hamilton G Middleton MS Chavez AD Schwimmer JB Lavine JE Sirlin CB 《Magnetic resonance imaging》2008,26(3):347-359
Quantification of fat has been investigated using images acquired from multiple gradient echoes. The evolution of the signal with echo time and flip angle was measured in phantoms of known fat and water composition and in 21 research subjects with fatty liver. Data were compared to different models of the signal equation, in which each model makes different assumptions about the T1 and/or T2* relaxation effects. A range of T1, T2*, fat fraction and number of echoes was investigated to cover situations of relevance to clinical imaging. Results indicate that quantification is most accurate at low flip angles (to minimize T1 effects) with a small number of echoes (to minimize spectral broadening effects). At short echo times, the spectral broadening effects manifest as a short apparent T2 for the fat component. 相似文献
16.
Hang Joon Jo Jong-Min Lee Jae-Hun Kim Chi-Hoon Choi Do-Hyung Kang Jun Soo Kwon Sun I. Kim 《Magnetic resonance imaging》2009
Surface-based functional magnetic resonance imaging (fMRI) analysis is more sensitive and accurate than volume-based analysis for detecting neural activation. However, these advantages are less important in practical fMRI experiments with commonly used 1.5-T magnetic resonance devices because of the resolution gap between the echo planar imaging data and the cortical surface models. We expected high-resolution segmented partial brain echo planar imaging (EPI) data to overcome this problem, and the activation patterns of the high-resolution data could be different from the low-resolution data. For the practical applications of surface-based fMRI analysis using segmented EPI techniques, the effects of some important factors (e.g., activation patterns, registration and local distortions) should be intensively evaluated because the results of surface-based fMRI analyses could be influenced by them. In this study, we demonstrated the difference between activations detected from low-resolution EPI data, which were covering whole brain, and high-resolution segmented EPI data covering partial brain by volume- and surface-based analysis methods. First, we compared the activation maps of low- and high-resolution EPI datasets detected by volume- and surface-based analyses, with the spatial patterns of activation clusters, and analyzed the distributions of activations in occipital lobes. We also analyzed the high-resolution EPI data covering motor areas and fusiform gyri of human brain, and presented the differences of activations detected by volume- and surface-based methods. 相似文献
17.
Diffusion-weighted echo planar imaging (DW-EPI) suffers from geometric distortion due to low phase-encoding bandwidth. Read-out segmented echo planar imaging (RS-EPI) reduces distortion but residual distortion remains in extreme cases. Additional corrections need to be applied, especially for radiotherapy applications where a high degree of accuracy is needed. In this study the use of magnetic field map corrections are assessed in DW-EPI and RS-EPI, to reduce geometric uncertainty for MRI-guided radiotherapy applications. Magnetic field maps were calculated from gradient echo images and distortion corrections were applied to RS-EPI images. Distortions were assessed in a prostate phantom by comparing to the known geometry, and in vivo using a modified Hausdorff distance metric using a T2-weighted spin echo as ground truth. Across 10 patients, field map-corrected RS-EPI reduced maximum distortion by 5 mm on average compared to DW-EPI (σ = 1.9 mm). Geometric distortions were also reduced significantly using field mapping with RS-EPI, compared to RS-EPI alone (p ≤ 0.05). The increased geometric accuracy of these techniques can potentially allow diffusion-weighted images to be fused with other MR or CT images for radiotherapy treatment purposes. 相似文献
18.
19.
PurposeTo implement and evaluate interleaved blip-up, blip-down, non-segmented 3D echo planar imaging (EPI) with pseudo-continuous arterial spin labeling (pCASL) and post-processing for reduced susceptibility artifact cerebral blood flow (CBF) maps.Materials and methods3D EPI non-segmented acquisition with a pCASL labeling sequence was modified to include alternating k-space coverage along phase encoding direction (referred to as “blip-reversed”) for alternating dynamic acquisitions of control and label pairs. Eight volunteers were imaged on a 3T scanner. Images were corrected for distortion using spatial shifting transformation of the underlying field map. CBF maps were calculated and compared with maps obtained without blip reversal using matching gray matter (GM) images from a high resolution 3D scan. Additional benefit of using the correction for alternating blip-up and blip-down acquisitions was assessed by comparing to corrected blip-up only and corrected blip-down only CBF maps. Matched Student t-test of overlapping voxels for the eight volunteers was done to ascertain statistical improvement in distortion.ResultsMean CBF value in GM for the eight volunteers from distortion corrected CBF maps was 50.8 ± 9.9 ml/min/100 gm tissue. Corrected CBF maps had 6.3% and 4.1% more voxels in GM when compared with uncorrected blip up (BU) and blip down (BD) images, respectively. Student t-test showed significant reduction in distortion when compared with blip-up images and blip-down images (p < 0.001). When compared with corrected BU and corrected BD only CBF maps, BU and BD corrected maps had 2.3% and 1% more voxels (p = 0.006 and 0.04, respectively).ConclusionPseudo-continuous arterial spin labeling with non-segmented 3D EPI acquisition using alternating blip-reversed k-space traversal and distortion correction provided significantly better matching GM CBF maps. In addition, employing alternating blip-reversed acquisitions during pCASL acquisition resulted in statistically significant improvement over corrected blip-up and blip-down CBF maps. 相似文献
20.
Christoph R. Becker Lothar R. Schad Walter J. Lorenz 《Magnetic resonance imaging》1994,12(8):1167-1174
A new method for the ultrafast generation of diffusion-weighted images is reported. The technique combines a quick echo split NMR imaging sequence with the principle of Stejskal and Tanner. It allows to determine the diffusion constant with nearly the same accuracy as the conventional spin-echo technique, requiring only a fraction of the time. The determined values for water doped with 1 g Cu(NO3)2 per liter of H2O and pure acetone were Dwater = (1.95 ± 0.02) × 10−9 m2/s and Dacetone = (4.05 ± 0.02) × 10−9 m2/s at 18.5°C. They are in good agreement both with literature and our own reference measurements using a diffusion-weighted spin-echo sequence. In addition, the temperature dependence of Dwater was measured in the range of 18.5–45.9°C and a good correspondence with reported data was found. 相似文献