首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
The coupling of solid-phase extraction (SPE) using bamboo charcoal (BC) as an adsorbent with a monolithic column-high performance liquid chromatography (MC-HPLC) method was developed for the high-efficiency enrichment and rapid determination of 16 polycyclic aromatic hydrocarbons (PAHs) in water. Key influence factors, such as the type and the volume of the elution solvent, and the flow rate and the volume of the sample loading, were optimized to obtain a high SPE recovery and extraction efficiency. BC as an SPE adsorbent presented a high extraction efficiency due to its large specific surface area and high adsorption capacity; MC as an HPLC column accelerated the separation within 8 min because of its high porosity, fast mass transfer, and low-pressure resistance. The calibration curves for the PAHs extracted were linear in the range of 0.2-15 μg/L, with the correlation coefficients (r(2)) between 0.9970-0.9999. This method attained good precisions (relative standard deviation, RSD) from 3.5 to 10.9% for the standard PAHs I aqueous solutions at 5 μg/L; the method recoveries ranged in 52.6-121.6% for real spiked river water samples with 0.4 and 4 μg/L. The limits of detection (LODs, S/N = 3) of the method were determined from 11 and 87 ng/L. The developed method was demonstrated to be applicable for the rapid and sensitive determination of 16 PAHs in real environmental water samples.  相似文献   

2.
The graphene functionalized with (3‐aminopropyl) triethoxysilane was synthesized by a simple hydrothermal reaction and applied as SPE sorbents to extract trace polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. These sorbents possess high adsorption capacity and extraction efficiency due to strong adsorption ability of carbon materials and large specific surface area of nanoparticles, and only 10 mg of sorbents are required to extract PAHs from 100 mL water samples. Several condition parameters, such as eluent and its volume, adsorbent amount, sample volume, sample pH, and sample flow rate, were optimized to achieve good sensitivity and precision. Under the optimized extraction conditions, the method showed good linearity in the range of 1–100 μg/L, repeatability of the extraction (the RSDs were between 1.8 and 2.9%, n = 6), and satisfactory detection limits of 0.029–0.1 μg/L. The recoveries of PAHs spiked in environmental water samples ranged from 84.6 to 109.5%. All these results demonstrated that this new SPE technique was a viable alternative to conventional enrichment techniques for the extraction and analysis of PAHs in complex samples.  相似文献   

3.
Guo L  Lee HK 《Journal of chromatography. A》2011,1218(52):9321-9327
Micro-solid-phase extraction (μ-SPE) was developed for the determination of trace level of 16 United States Environmental Protection Agency priority polycyclic aromatic hydrocarbons (PAHs) in river water samples with gas chromatography-mass spectrometry (GC-MS). In the μ-SPE device, multiwalled carbon nanotubes was employed as sorbent and was packed inside an porous polypropylene membrane "envelope" whose edges were heat-sealed to secure the contents. The μ-SPE device was placed in a stirred sample solution to extract the analytes. The porous polypropylene membrane envelope in μ-SPE device acts as a filter to exclude potential interferences, such as eliminating or reducing the influence of particles that are bigger than the pore size. After extraction, analyte desorption was carried out with a suitable organic solvent under ultrasonication. Important extraction parameters were optimized in detail, including the selection and amount of sorbent materials, the extraction temperature and extraction time, desorption solvent and desorption time, amount of organic modifier, agitation speed and sample ionic strength. Under the developed extraction conditions, the proposed method provided good linearity in the range of 0.1-50 μg/L, low limits of detection (4.2-46.5 ng/L), and good repeatability of the extractions (relative standard deviations, <12%, n=5). The developed μ-SPE method was successfully applied to the extraction of PAHs in river water samples. The μ-SPE method was demonstrated to be a fast and efficient method for the determination of PAHs from environmental water samples.  相似文献   

4.
An on-line solid phase extraction (SPE) ultra high performance liquid chromatography tandem mass spectrometry method has been developed for the simultaneous identification and determination of thirteen polycyclic aromatic hydrocarbons (PAHs) and twelve aldehydes (derivatized with 2,4-dinitrophenylhydrazine). The chromatographic conditions have been optimized to obtain the maximum of sensitivity and resolution taking into account the different retention interactions and the different ionization conditions of PAHs and derivatized aldehydes. LOD values ranging from 0.028 to 0.768 μg L(-1) for PAHs and from 0.002 to 0.125 μg L(-1) for aldehydes were obtained. The resolution permitted the separation of four couples of PAH isomers. Sample pre-treatment and SPE were optimized in order to apply the whole methodology to the analysis of different food matrices as salmon, frankfurter, steak, and pork chop, subjected to different cooking modes (smoked, grilled, cooked in oil or in butter). Particular attention was devoted to the evaluation of matrix effect that was significantly reduced through the on-line SPE treatment. For each food matrix the method detection limits, the method quantitation limits, and the recovery R were evaluated. R was shown not to depend on analyte concentration in the explored concentration range (LOQ - 50.000 μg L(-1)): the average R percent ranges from 70.6% to 120.0%.  相似文献   

5.
优化了土壤中16种优控多环芳烃( PAHs)的分析方法,建立了一套完备的质量控制体系,解决了PAHs分析中常见的技术难点,如苯并(a)芘(BaP)回收率低,基质复杂的样品净化效果不理想,萘(Nap)和菲(Phe)挥发损失和环境本底影响等.样品经加速溶剂提取(ASE),固相萃取(SPE)净化,逐级减压浓缩,气相色谱质谱( GC - MS)测定,并以氘代苯并a芘(BaP - d12)作回收率指示物.实验比较了3种正相SPE吸附剂的效果,发现弗罗里硅土对BaP存在明显的降解现象,BaP的定量应使用同位素稀释法,以降低其分析不确定度;氧化铝对PAHs的吸附性过强,不利于样品净化;硅胶最为理想.PAHs的仪器检出限为0.26~5.7 pg,方法检出限为0.067 ~0.97 ng/g(干重),土壤基质加标回收率为71%~ 122%,相对标准偏差为1.6%~8.3%.将该法用于7个电子废物焚烧区域农田土壤样品的测定,PAHs含量在28~ 283 ng/g(干重)之间,样品中BaP-d12的回收率为90%~124%,各项质控指标符合检测要求.  相似文献   

6.
建立了磁性聚亚苯基共轭微孔聚合物富集/表面增强拉曼光谱法测定水样和土壤中4种多环芳烃的分析方法。待测物经磁性聚亚苯基共轭微孔聚合物吸附萃取,甲醇洗脱后进行SERS检测。结果表明,蒽、芘、荧蒽和苯[α]芘在0.1~10μg/L范围内与其SERS特征峰峰强呈良好的线性关系,检出限为0.03μg/L,回收率为71.6%~115.8%,相对标准偏差不大于13.7%。该分析方法灵敏度高,能够满足实际水样和土壤中4种多环芳烃同时检测的要求。  相似文献   

7.
以自制的1-十八烷基-3-(γ-三乙氧基硅基丙基)咪唑溴盐离子液体(C18IL)、二苯基二甲氧基硅烷(DDS)和四乙氧基硅烷(TEOS)为功能单体,采用溶胶-凝胶法制备了烷基咪唑基离子液体管内固相微萃取整体柱(C18IL in-tube SPME).以多环芳烃为分析对象,考察了C_(18)IL含量对C_(18)IL in-tube SPME萃取性能的影响,并对萃取条件进行了优化.建立了基于C_(18)IL in-tube SPME-气相色谱(GC-FID)的分析方法,用于检测萘、芴、菲、荧蒽和芘5种多环芳烃.该方法的检出限(S/N=3)为0.007~0.072μg/L,定量限(S/N=10)为0.023~0.24μg/L,日内和日间精密度(RSD)除菲类多环芳烃外均小于10%.将该方法用于检测咖啡中5种多环芳烃,3个不同浓度下的加标回收率为85.79%~103.42%.  相似文献   

8.
<正>Triacontyl modified silica gel as a sorbent coupled with gas chromatography-mass spectrometry(GC-MS) was developed to determine EPA prior 16 polycyclic aromatic hydrocarbons(PAHs) in water samples.Various parameters of solid-phase extraction such as organic modifier solvent,eluent,sample flow rate and volume were optimized.The developed method was found to yield a linear calibration curve in the concentration range of 0.05-8μg/L with respect to naphthalene,acenaphthylene,acenaphthene and 0.01-8μg/L for dibenz[a,h]anthracene and 0.05-14μg/L for fluorene,phenanthrene,anthracene and 0.01-14μg/L for the rest of analytes.Furthermore,the good accuracy and repeatability of the method made sure the requirements for achieving reliable analysis of PAHs in the environmental water samples,and the recoveries of optimal method were in the range of 80-120%except to higher volatility PAHs.C_(30)-bonded silica was proved to be an efficient sorbent for extraction of high molecular weight PAHs.  相似文献   

9.
建立了地下水中低环多环芳烃及其衍生物的全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)检测方法。对比研究了液液萃取(LLE)和固相萃取(SPE)对地下水中低环多环芳烃及其衍生物的提取效率,优选液液萃取为前处理方法。在优化条件下,除1,2,3,4-四氢萘(r=0.987 2)和联苯(r=0.989 9)外,其它目标物在0.1~1 000μg/L范围内具有良好的线性关系,相关系数(r)均大于0.99。地下水的平均加标回收率为63.3%~111%,除喹啉的相对标准偏差(RSD,n=6)为24.9%外,其余目标物的RSD均小于9.5%,方法检出限在1.63~14.7 ng/L之间。该方法用于河北地区6个地下水样中低环多环芳烃及其衍生物的检测,4个样品有检出,最高浓度达353 ng/L。  相似文献   

10.
王超  黄肇章  邢占磊  陈烨  于建钊  刘方  袁懋 《色谱》2019,37(2):239-245
建立了在线固相萃取-液相色谱直接测定水体中16种超痕量多环芳烃(PAHs)的方法。水样经高速离心后,加入适量甲醇,配制成40%(体积分数)甲醇水溶液,直接进样2 mL至在线固相萃取流路,进行萃取富集,再通过阀切换将洗脱的PAHs转移至分析流路进行分离检测。16种PAHs在各自范围内线性关系良好,相关系数均大于0.996;方法的检出限为0.14~12.50 ng/L,其中苯并[a]芘(B(a)P)的检出限为0.38 ng/L。实际水样在10、40和200 ng/L加标水平下的加标回收率为76.1%~134.9%,RSD为0.3%~16.6%。B(a)P在1 ng/L加标水平下的回收率为71.8%~92.7%,RSD为3.9%。结果表明,该方法操作简单,灵敏度高,溶剂消耗量少,可满足水样中PAHs,尤其是B(a)P的超痕量分析要求。  相似文献   

11.
Multiwalled carbon nanotubes (MWCNTs) were used as a novel kind of solid-phase extraction adsorbents in this work as well as an analytical method based on MWCNTs solid-phase extraction (SPE) combined with high-performance liquid chromatography (HPLC) was established for the determination of polycyclic aromatic hydrocarbons (PAHs), some of which belong to typical persistent organic pollutants (POPs) owing to their carcinogenicity and endocrine disrupting activity. Several conditions that probably affected the extraction efficiency including the eluent volume, sample flow rate, sample pH and the sample volume were optimized in detail. The characteristic data of analytical performance were determined to investigate the sensitivity and precision of the method, and the method was applied to the determination of PAHs in environmental water samples such as river water sample, tap water sample and wastewater sample from the constructed wetland effluent. The experimental results indicated that there were excellent linear relationship between peak area and the concentration of PAHs over the range of 0.04-100 microg L(-1), and the precisions (RSD) were 1.7-4.8% under the optimal conditions. The detection limits of proposed method for the studied PAHs were 0.005-0.058 microg L(-1) (S/N=3). The recoveries of PAHs spiked in environmental water samples ranged from 78.7 to 118.1%. It was concluded that MWCNTs packed cartridge coupled with HPLC was an excellent alternative for the routine analysis of PAHs at trace level.  相似文献   

12.
王玲玲  余晟  余萌 《化学通报》2012,(7):648-652
建立了石墨烯固相萃取柱萃取和高效液相色谱法检测8种稠环芳烃的方法。采用紫外检测器进行定性和定量分析。对包括吸附剂的种类、洗脱剂的种类和用量、样品溶液的pH和样品体积等实验参数进行了详细优化。在优化条件下,8种稠环芳烃在0.0200~150μg/L浓度范围内与峰面积呈良好的线性关系,相关系数为0.990~0.996。信噪比为3时,稠环芳烃的检出限为0.0020~0.080μg/L。方法的精密度为1.30%~4.65%。将该方法用于环境水样分析,回收率为82.50%~106.5%。  相似文献   

13.
张文敏  李青青  方敏  张兰 《色谱》2022,40(11):1022-1030
环境样品中多环芳烃(PAHs)含量较低且样品基质复杂,直接利用仪器进行含量测定比较困难,因此在仪器分析之前需要对环境样品进行必要的前处理。大多数前处理技术的萃取效率取决于萃取材料的特性。目前,金属有机骨架材料(MOFs)作为一种由金属离子与有机配体自组装而成的多孔材料,已经被用作固相微萃取(SPME)的涂层材料应用于PAHs的萃取,但是这些MOFs涂层材料由于目标物较难达到其深层的吸附位点,使得萃取过程往往需要较长的平衡时间;此外,大多数MOFs由单金属离子配位构成,能够提供的开放金属活性位点种类比较单一,较难获得最佳的萃取性能。这些问题在一定程度上限制了MOFs材料在SPME领域的应用。该研究制备了一种中空结构的双金属有机骨架材料(H-BiMOF),并将其作为SPME的涂层材料,用于萃取环境样品中痕量的PAHs。由于中空的结构和双金属的组成,H-BiMOF涂层材料拥有比表面积利用率高、传质距离短等优点,可以使萃取过程快速地达到平衡。同时,双金属的引入提供了种类丰富的金属活性位点,提高了对PAHs这类富电子云目标物的萃取效率。与气相色谱-串联质谱(GC-MS/MS)相结合,建立了一种用于环境水样中PAHs分析的新方法。所建立的分析方法具有检出限低(0.01~0.08 ng/L)、线性范围宽(0.03~500.0 ng/L)、重复性良好(相对标准偏差≤9.8%, n=5)等优点,并成功地用于实际湖水样品中7种PAHs的检测。实验结果表明,所建立的分析方法适用于环境样品中PAHs的分析与监测。  相似文献   

14.
A high-performance liquid chromatographic method with electrochemical detection (HPLC-ED) at a boron-doped diamond film electrode with preliminary separation and preconcentration by solid-phase extraction (SPE) has been developed for the determination of 1-hydroxypyrene (1-HP) in human urine. 1-HP is among the most widely used biomarkers of exposure to polycyclic aromatic hydrocarbons. Optimal HPLC-ED conditions have been found: mobile phase methanol-0.05 mol L(-1) phosphate buffer pH 5.0 (80:20, v/v), detection potential +1,000 mV versus Ag/AgCl (3 mol L(-1) KCl), and flow rate 0.8 mL min(-1). For SPE, LiChrolut(?) RP-18 E cartridges were used. The extraction yield was (87.0 ± 5.8)% (n = 5). The concentration dependence of 1-HP was measured in the concentration range from 0.01 to 10 μmol L(-1) (2.18-2,180 μg L(-1)) using methanolic solutions resulting from the SPE pretreatment of spiked human urine samples. The limit of detection (signal-to-noise ratio 3) and the limit of quantification (signal-to-noise ratio 10) of the biomarker were 0.013 μmol L(-1) (2.84 μg L(-1)) and 0.043 μmol L(-1) (9.39 μg L(-1)), respectively, which is sufficient for its determination in the urine of persons exposed to polycyclic aromatic hydrocarbons.  相似文献   

15.
Nuno Ratola  Damià Barceló 《Talanta》2009,77(3):1120-1128
Two different extraction strategies (microwave-assisted extraction (MAE) and ultrasonic extraction (USE)) were tested in the extraction of the 16 US Environmental Protection Agency (EPA) polycyclic aromatic hydrocarbons (PAHs) from pine trees. Extraction of needles and bark from two pine species common in the Iberian Peninsula (Pinus pinaster Ait. and Pinus pinea L.) was optimized using two amounts of sample (1 g and 5 g) and two PAHs spiking levels (20 ng/g and 100 ng/g). In all cases, the clean-up procedure following extraction consisted in solid-phase extraction (SPE) with alumina cartridges. Quantification was done by gas chromatography (GC) with mass spectrometry (MS), using five deuterated PAH surrogate standards as internal standards. Limits of detection were globally below 0.2 ng/g. The method was robust for the matrices studied regardless of the extraction procedures. Recovery values between 70 and 130% were reached in most cases, except for high molecular weight PAHs (indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[ghi]perylene). A field study with naturally contaminated samples from eight sites (four in Portugal and four in Catalonia, Spain) showed that needles are more suitable biomonitors for PAHs, yielding concentrations from 2 to 17 times higher than those found in bark. The levels varied according to the sampling site, with the sum of the individual PAH concentrations between 213 and 1773 ng/g (dry weight). Phenanthrene was the most abundant PAH, followed by fluoranthene, naphthalene and pyrene.  相似文献   

16.
A solid-phase extraction (SPE) method using triacontyl bonded silica (C30) as sorbent was developed for the determination of 16 US Environmental Protection Agency polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matters quantitatively by gas chromatography-mass spectrometry (GC-MS). Optimization experiments were conducted using spiked standard aqueous solution of PAHs and real airborne particulates samples aiming to obtain highest SPE recoveries and extraction efficiency. Factors were studied in SPE procedures including the concentration of organic modifier, flow rate of sample loading and elution solvents. The ultrasonication time and solvents were also investigated. Recoveries were in the range of 68-107% for standard PAHs aqueous solution and 61-116% for real spiked sample. Limits of detection (LODs) and limits of quantification (LOQs) with standard solution were in the range of 0.0070-0.21 microgL(-1) and 0.022-0.67 microgL(-1), respectively. The optimized method was successfully applied to the determination of 16 PAHs in real airborne particulate matters.  相似文献   

17.
This paper demonstrates, for the first time, the great potential of using Zn/Al layered double hydroxide intercalated sodium dodecyl benzene sulfonate (Zn/Al-SDBS-LDH) as a solid-phase extraction (SPE) material in the extraction of persistent organic pollutants prior to the determination of gas chromatography-mass spectrometry in environmental water samples. Zn/Al-SDBS-LDH, a relatively inexpensive and simply prepared material, was synthesized and used as a SPE adsorbent to quantitatively determine the concentration of five polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Factors affecting extraction efficiency, such as, eluent type, eluent volume, flow rate of sample, sample volume, and amount of adsorbent, were investigated and optimized in detail. Experimental results indicate that there is an excellent linear relationship between peak area and the concentration of PAHs over the range of 5-500 ng L(-1), and the precisions (relative standard deviation (RSD)) were 2.5-6.3% under the optimum conditions. Based on the ratio of chromatographic signal-to-base line noise (S/N = 3), the limits of detection could reach 1.2-3.2 ng L(-1). This novel method was successfully applied to the analysis of PAHs in environmental water samples. As such, we show here that the use of Zn/Al-SDBS-LDH as SPE adsorbent materials, coupled with gas chromatography-mass spectrometry, is an excellent improvement in the routine analysis of PAHs at trace levels in the environment.  相似文献   

18.
余晟  黄克靖  余萌  韦彩云 《分析化学》2012,(7):1065-1070
利用石墨烯固相萃取柱萃取、高效液相色谱分离紫外检测,建立了戊唑醇、乙霉威、晴菌唑、精甲霜灵和扑草净5种农药同时检测的方法。确定的优化条件为:洗脱剂为5mL二氯甲烷、样品溶液的pH=7.0,样品体积为200mL。在此条件下,扑草净、戊唑醇、乙霉威、晴菌唑和精甲霜灵在0.05~100μg/L浓度范围内与峰面积呈良好的线性关系,相关系数为0.895~0.992;信噪比为3时,5种农药的检出限为1.2~5.2ng/L;方法的精密度为1.4%~4.6%。将本方法用于环境水样标准加入分析,相对回收率为80.5%~107.6%;相对标准偏差均小于5%。  相似文献   

19.
用分散液液微萃取-气相色谱/质谱法测定水样中的16种多环芳烃(PAHs)。通过实验确定最佳萃取条件为:20μL四氯化碳作萃取剂,1.0 mL乙腈作分散剂,超声萃取1 min。在优化条件下,多环芳烃的富集倍数达到216~511,方法在0.05~50μg/L范围内呈良好的线性关系,相关系数(R2)在0.9873~0.9983之间,检出限为0.0020~0.14μg/L。相对标准偏差(RSD)在3.82%~12.45%(n=6)之间。该方法成功用于实际水样中痕量多环芳烃的测定。  相似文献   

20.
杨晓涵  吴雯倩  王彬  林风  吴小海  卢昕 《色谱》2020,38(2):195-205
利用多巴胺(DA)中的儿茶酚基团能与金属有机骨架晶体(MOFs)中金属离子螯合的原理,以ZIF-67为模板,经DA蚀刻-自聚合形成具有孔洞结构的聚多巴胺(PDA)壳层,制备了磁性-MOFs-PDA(Fe3O4@Z67D)新型材料。多种表征手段验证了材料的形貌、结构和性能。新型材料具有亲水性的表面、纳米级的孔径,以及良好的磁响应,被用作磁固相萃取吸附剂。结合高效液相色谱分析手段,建立了萃取检测亚甲蓝(MB)和结晶紫(CV)两种阳离子染料的新方法。在最优的萃取和色谱分析条件下,MB和CV的线性范围分别为0.5~200 μg/L和0.01~50 μg/L,检出限分别为0.04 μg/L和0.008 μg/L,对两种染料的富集因子分别为777和688。新型材料重复使用10次,其萃取性能未见发生变化。该方法成功应用于检测淡水鱼养殖用水中痕量的MB和CV,加标回收率为82.0%~109.0%,RSD低于2.9%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏