首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple procedure for the determination of methyl tert-butyl ether (MTBE), ethyl tert-butyl ether (ETBE), ethyl butyl ether (EBE), tert-amyl methyl ether (TAME), benzene, toluene, ethylbenzene, and xylenes (BTEX) in water using headspace (HS) solid-phase microextraction (HS-SPME) was developed. The analysis was carried out by gas chromatography (GC) equipped with flame ionization detector (FID) and 100% dimethylpolysiloxane fused capillary column. A 2 Plackett-Burman design for screening and a central composite design (CCD) for optimizing the significant variables were applied. Fiber type, extraction temperature, sodium chloride concentration, and headspace volume were the significant variables. A 65 microm poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) SPME fiber, 10 degrees C, 300 g/l, and 20 ml of headspace (in 40 ml vial) were respectively chosen for the best extraction response. An extraction time of 10 min was enough to extract the ethers and BTEX. The relative standard deviation (R.S.D.) for the procedure varied from 2.6 (benzene) to 8.5% (ethylbenzene). The method detection limits (MDLs) found were from 0.02 (toluene, ethylbenzene, and xylenes) to 1.1 microg/l (MTBE). The optimized method was applied to the analysis of the rivers, marinas and fishing harbors surface waters from Gipuzkoa (North Spain). Three sampling were done in 1 year from June 2002 to June 2003. Toluene was the most detected analyte (in 90% of the samples analyzed), with an average concentration of 0.56 microg/l. MTBE was the only dialkyl ether detected (in 15% of the samples) showing two high levels over 400 microg/l that were related to accidental fuel spill.  相似文献   

2.
In this article, the potential of carbon nanocones/disks as coating for solid-phase microextraction has been evaluated for the first time. The nanostructures were immobilized on a stainless steel needle by means of an organic binder. The fiber coating obtained was ca. 50 μm of thickness and 35 mm in length. The evaluation of the sorbent capacity was carried out through the determination of toluene, ethylbenzene, xylene isomers and styrene in water samples following the headspace sampling modality (15 min, 30 °C). The fiber was then transferred to a 10 mL vial which was sealed and heated at 110 °C for 15 min in the headspace module of the instrument to achieve the thermal desorption of the analytes. Then 2.5 mL of the headspace generated were injected in the gas chromatograph-mass spectrometer for analytes separation and quantitation. The detection and quantitation limits obtained for 10 mL of sample were 0.15 and 0.5 ng mL−1 (0.6 and 2 ng mL−1 for toluene). The optimized procedure was applied to the determination of the selected volatile compounds in waters collected from different locations. The recovery values obtained (average recovery ca. 92%) demonstrated the usefulness of the carbon nanocones/disks as sorbent material in solid-phase microextraction.  相似文献   

3.
Practical aspects of the application of solid-phase microextraction (SPME) to the determination of volatile aliphatic amines in air are described. Analytes included methylamine (MA), ethylamine (EA), dimethylamine (DMA), diethylamine (DEA), trimethylamine (TMA) and triethylamine (TEA). New SPME stationary phases were examined. The effects of relative humidity and temperature on analytes uptake were taken into account in analysis. Gas chromatography (GC) with flame ionization detector (FID) was used for the final analysis.  相似文献   

4.
Feng J  Sun M  Liu H  Li J  Liu X  Jiang S 《Journal of chromatography. A》2010,1217(52):8079-8086
A novel solid-phase microextraction fiber based on a stainless steel wire coated with Au nanoparticles was prepared and has been applied, coupled with gas chromatography, to the extraction of aromatic hydrophobic organic chemical pollutants in rainwater and soil extract. The solid-phase microextraction fiber exhibited excellent extraction efficiency and selectivity. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized. Single fiber repeatability and fiber-to-fiber reproducibility were less than 7.90% and 26.40%, respectively. The calibration curves were linear in a wide range for all analytes. Correlation coefficients ranged from 0.9941 to 0.9993. The as-established SPME-GC method was used successfully to two real natural samples. Recovery of analytes spiked at 10 μg L(-1) and 100 μg L(-1) ranged from 78.4% to 119.9% and the relative standard deviations were less than 11.3%.  相似文献   

5.
Summary Extra-fine powdered activated charcoal has been used as stationary phase (coating layer) in solid-phase microextraction (SPME). The efficiency and reliability of the prepared device have been investigated for the extraction of some volatile organic compounds such as benzene, toluene, ethylbenzene and xylene isomers (BTEX) from the headspace of water samples. Monitoring of the extracted compounds and further quantitative analysis of the real samples have been performed by capillary GC-FID. Effects of several factors such as temperature, addition of salt, and stirring speed on extraction efficiency and exposure time have been studied. Under optimum conditions, extraction recoveries for these compounds from 50 mL water were >95%. The calibration graphs were linear in the range 5 to 104 pg mL−1 and the detection limit for each BTEX compound was 1.5–2 pg mL−1. The results obtained by use of this porous layer activated charcoal (PLAC)-coated fiber have also been compared with results reported in the literature by use of a polydimethylsiloxane (PDMS)-coated fiber. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996  相似文献   

6.
A solid-phase microextraction (SPME) fiber coated with single walled carbon nanotubes (SWCNTs) was prepared by electrophoretic deposition and treated at 500 °C in H2 stream. In order to evaluate the characteristics of the obtained fiber, it was applied in the headspace solid-phase microextraction (HS-SPME) of benzene, toluene, ethylbenzene and xylenes (BTEX) from water sample and quantification by gas chromatography with flame ionization detection (GC-FID). The results indicated that the thermal treatment with H2 enhanced the extraction of the SWCNTs fiber for BTEX significantly. Thermal stability and durability of the fiber were also investigated, showing excellent stability up to 350 °C and life time over 120 times. In the comparison with the commercial CAR–PDMS fiber, the SWCNTs fiber showed similar and higher extraction efficiencies for BTEX. Under the optimized conditions, the linearity, LODs (S/N = 3) and LOQs (S/N = 10) of the method based on the SWCNTs fiber were 0.5–50.0, 0.005–0.026 and 0.017–0.088 μg/L, respectively. Repeatability for one fiber (n = 3) was in the range of 1.5–5.6% and fiber-to-fiber reproducibility (n = 3) was in the range of 4.2–8.3%. The proposed method was successfully applied in the analysis of BTEX compounds in seawater, tap water and wastewater from a paint plant.  相似文献   

7.
This work describes a new approach for the determination of trimethylamine (TMA) in water and air by liquid chromatography (LC). The assay is based on the employment of a solid-phase microextraction (SPME) fiber for sampling and for derivatization of the analyte with the fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC). The fiber, with a Carbowax-templated resin −50 μm coating, was first immersed into a solution of the reagent. Once loaded with the reagent, the fiber was immersed into the water samples or exposed to the air samples in order to extract and to derivatize the analyte. Finally, the fiber was placed into a HPLC-SPME interface to desorb and transfer the TMA-FMOC derivative to the LC equipment. A comparative study of the analytical characteristics of the procedure in water and air samples was carried out. Under optimized conditions, the proposed approach permits the quantification of TMA in solution within the 1.0-10.0 μg/ml interval and in air within the 25-200 mg/m3 interval. The limits of detection were 0.25 μg/ml and 12 mg/m3 (25 °C, 1.013 × 10−5 Pa) in water and air, respectively. The utility of the proposed method for determining TMA in different kind of samples is discussed.  相似文献   

8.
Applications of solid-phase microextraction (SPME) to the sampling and analysis of volatile organic compounds in indoor air are reviewed, including a summary of quantification methods, coatings, compounds, concentrations, sampling locations and times, and detection limits. Strategies for on-site and off-site sampling and analysis, advantages and challenges associated with SPME for air sampling are discussed.  相似文献   

9.
This work is a first study on extraction efficiency and thermal stability of nano-structured self-doped polyaniline (SPAN) as a coating of solid-phase microextraction (SPME) fibers. SPAN-based fibers were prepared using electrochemical deposition on platinum wires. The particle sizes of prepared nano-structure were in the range of 50–100 nm. Extraction properties of the fiber to 1,4-dioxane were examined using headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography-flame ionization detection (GC-FID). The results have proved higher thermal stability of the proposed fiber compared to common PANI fiber. The SPAN coating was proved to be very stable at relatively high temperatures (up to 350 °C) with high extraction capacity and long lifespan (more than 50 times). Therefore, it can be a good substitute of polyaniline (PANI) as a SPME coating. The extraction procedure was optimized by selecting the appropriate extraction parameters including extraction time, extraction temperature, salt concentration, stirring rate and headspace volume. Calibration graph was linear in the concentration range of 1–100 ng mL−1 (R2 > 0.993) with detection limit of 0.1 ng mL−1. Single fiber and fiber-to-fiber repeatability were lower than 6.0% and 10.4%, respectively. Different water samples were analyzed as real samples and good recoveries (98–120%) were obtained.  相似文献   

10.
Solid-phase microextraction (SPME) is a convenient and efficient sampling technique recently applied to indoor air analysis. We propose here a theoretical model of the adsorption kinetics of toluene on SPME fibre under static extraction conditions. We discuss the effects of sampling volume and initial concentration of analyte on the adsorption kinetics. This model is used to estimate the limits of detection taking into account operating conditions and to calculate theoretical calibration curves. Results of comparison with experimental data are encouraging: only 11% difference for calibration curves and 30% for the estimation of the limit of detection. On the basis of this kinetics model, the solid concentration gradient in the Carboxen coating was modelled with Fick’s second law of diffusion in unsteady-state mass-transfer mode. Mass diffusion from the gas sample to the SPME fibre was also investigated. It was shown that diffusion is the limiting step of the mass-transfer process in the static mode. Thus, the model developed, allows a better understanding of adsorption on Carboxen fibre and in the future could be a useful tool for cheap and time-saving development of SPME methods and the estimation of sampling performance. Figure PDMS/Carboxen SPME fibre (scanning electron microscopy – magnification x 220)  相似文献   

11.
The possibility of quantitative analysis of aromatic hydrocarbons in oil-based asphalt release agents was investigated using headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). The target analytes studied were benzene, toluene, ethylbenzene, p-, m-, and o-xylene (BTEX) and 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene. Experimental parameters influencing HS-SPME efficiency were studied (equilibration time between sample and headspace and between headspace and SPME fiber, sample amount and sample matrice effects). A HS-SPME method using hexadecane as a surrogate matrice was developed. The detection limit was estimated as 0.03-0.08 ppm (w/w) for the target analytes investigated. Good linearity was observed (R2 > 0.999) for all calibration curves at high, medium and low concentration level. The repeatability of the method (RSD, relative standard deviation) was found to be less than 10% (generally less than 5%) in triplicate samples and approximately 2% at eight consecutive tests on one and the same sample. The accuracy of the method given by recovery of spiked samples was between 85 and 106% (generally between 95 and 105%). The HS-SPME method developed was applied to four commercially available asphalt release agents. External calibration and standard addition approaches were investigated regarding accuracy. The results showed that standard addition generates higher accuracy than external calibration. The contents of target aromatic hydrocarbons in the asphalt release agents studied varied greatly from approximately 0.1-700 ppm. The method described looks promising, and could be a valuable tool for determination of aromatic hydrocarbons in different types of organic matrices.  相似文献   

12.
The present work reports preparation of ordered mesoporous carbon (OMC) film supported on a graphite fiber as a new type of solid-phase microextraction (SPME) fiber for determination of benzene series from aqueous media. The strategy for the supported OMC film preparation was combined dip-coating technology with solvent evaporation-induced self-assembly (EISA) approach. A graphite fiber was immersed in an ethanol solution containing phenolic resin and Pluronic triblock copolymer. Upon solvent evaporation and subsequent pyrolysis under 700 °C, the phenolic resin and the surfactant self-assembled on the surface of the graphite fiber to form smooth OMC film. X-ray diffraction (XRD), transmission electron microscopy (TEM) and nitrogen isothermal adsorption results indicate that the resultant OMC film possesses well-ordered two dimensional hexagonal mesostructure with pore diameters of 4.5 nm and BET surfaces of 630 m2/g. Scanning electron microscopy (SEM) studies show the supported OMC film with thickness at 8.5 μm is continuous and defect-free. The SPME efficiency of the OMC fiber was evaluated by analysis of five benzene series (benzene, toluene, ethylbenzene, p-xylene and m-xylene) from water samples by gas chromatography-flame ionization detection (GC-FID). The analysis results indicate that the prepared OMC fiber has wide linear ranges (0.5–500 μg/L), low detection limits (0.01–0.05 μg/L) and good repeatabilities (4.0–5.8% for one fiber, 2.9–8.7% for fiber-to-fiber). Compared with commercial counterparts, the OMC fiber exhibits improved extraction efficiency for benzene series and PAHs.  相似文献   

13.
Competitive adsorption on adsorptive solid-phase microextraction (SPME) fibres implies careful determination of operating conditions for reliable quantitative analysis of VOCs in indoor air. With this objective, two analytical approaches, involving non-equilibrium and equilibrium extraction, were compared. The average detection limit obtained for GC-MS analysis of nine VOCs by the equilibrium method is 0.2 μg m−3, compared with 1.9 μg m−3 with the non-equilibrium method. The effect of the relative humidity of the air on the calibration plots was studied, and shown to affect acetone adsorption only. Hence, the concentrations that can be accurately determined are up to 9 μmol m−3. The methods were then applied to indoor air containing different concentrations of VOCs. The non-equilibrium method, involving short extraction time, can be used for detection of pollution peaks whereas equilibrium extraction is preferable for measurement of sub-μg m−3 ground concentration levels.   相似文献   

14.
Zhu F  Guo J  Zeng F  Fu R  Wu D  Luan T  Tong Y  Lu T  Ouyang G 《Journal of chromatography. A》2010,1217(50):7848-7854
Two kinds of porous carbon materials, including carbon aerogels (CAs), wormhole-like mesoporous carbons (WMCs), were synthesized and used as the coatings of solid-phase microextraction (SPME) fibers. By using stainless steel wire as the supporting core, six types of fibers were prepared with sol-gel method, direct coating method and direct coating plus sol-gel method. Headspace SPME experiments indicated that the extraction efficiencies of the CA fibers are better than those of the WMC fibers, although the surface area of WMCs is much higher than that of CAs. The sol-gel-CA fiber (CA-A) exhibited excellent extraction properties for non-polar compounds (BTEX, benzene, toluene, ethylbenzene, o-xylene), while direct-coated CA fiber (CA-B) presented the best performance in extracting polar compounds (phenols). The two CA fibers showed wide linear ranges, low detection limits (0.008-0.047μgL(-1) for BTEX, 0.15-5.7μgL(-1) for phenols) and good repeatabilities (RSDs less than 4.6% for BTEX, and less than 9.5% for phenols) and satisfying reproducibilities between fibers (RSDs less than 5.2% for BTEX, and less than 9.9% for phenols). These fibers were successfully used for the analysis of water samples from the Pearl River, which demonstrated the applicability of the home-made CA fibers.  相似文献   

15.
A novel cedar-like Au nanoparticles (AuNPs) coating was fabricated on an etched stainless steel (SS) wire by direct chemical deposition and used as an efficient and unbreakable solid phase microextraction (SPME) fiber. The etched SS wire offers a rough surface structure for subsequent growth of AuNPs in chloroauric acid solution. As a result, the uniform cedar-like AuNPs coating with larger surface area was tightly attached to the etched SS wire substrate. The AuNPs coated etched SS fiber (AuNPs/SS) was examined for SPME of ultraviolet (UV) filters, phthalate esters and aromatic hydrocarbons coupled to high-performance liquid chromatography with UV detection. The fabricated fiber exclusively exhibited excellent extraction efficiency and selectivity for some aromatic hydrocarbons. Influential parameters of extraction and desorption time, temperature, stirring rate and ionic strength were investigated and optimized. The limits of detection ranged from 0.008 μg L−1 to 0.037 μg L−1. The single fiber repeatability varied from 3.90% to 4.50% and the fiber-to-fiber reproducibility ranged from 5.15% to 6.87%. The recovery of aromatic hydrocarbons in real water samples spiked at 2.0 μg L−1 and 20 μg L−1 ranged from 94.38% to 106.2% with the relative standard deviations below 6.44%. Furthermore the growth of the cedar-like AuNPs coating can be performed in a highly reproducible manner. This fabricated fiber exhibits good stability and withstands at least 200 extraction and desorption replicates.  相似文献   

16.
Nafion/活性炭涂层固相微萃取探头的制备与应用研究   总被引:4,自引:0,他引:4  
采用Nafion和活性炭粉末作为固相涂层在不锈钢丝上交替涂制了固相微萃取探头(SPME),研究了它的特性,并与商品类似探头和单纯的Nafion探头作了比较。该探头可比商品探头(SPME)的富集率高1个数量级。由于Nafion有很强的极性,因此它对极性化合物有很强的萃取能力,适合萃取醇等物质。用该探头测定了醇类、酯类物质,检出限低于10ng/mL,相对标准偏差RSD<6 3%。  相似文献   

17.
以苯基官能化MCM-41介孔复合体作为固相微萃取(SPME)的吸附涂层, 与高效液相色谱(HPLC)联用测定了不同水样中邻苯二甲酸二甲酯(DMP)、邻苯二甲酸二乙酯(DEP)、邻苯二甲酸二丁酯(DBP)和邻苯二甲酸二辛酯(DOP)的含量, 对SPME的吸附和解吸时间、温度、搅拌速度进行了优化, 线性范围分别为1.19×10-4~119 μg/L、 1.12×10-4~112 μg/L、 1.05×10-4~105 μg/L和9.80×10-5~98 μg/L, 检出限依次为0.030、 0.027、 0.029和0.022 ng/L. 使用该方法测定了多种水样中邻苯二羧酸酯类化合物.  相似文献   

18.
Yuan Y  Li H  Han S  Hu L  Xu G 《Talanta》2011,84(1):49-52
Because of its unique pore network, good strength, and low cost, cement was used as a new electrode material and solid-phase microextraction (SPME) material for the first time. It was mixed with carbon to make a new electrode, cement carbon electrode (CCE). The as-prepared CCE was used to demonstrate the application of cement in SPME by Ru(bpy)32+ electrochemiluminescent detection of perphenazine (PPZ). The calibration plot for PPZ is linear from 1.0 × 10−9 to 3.0 × 10−6 M with a detection limit of 3.1 × 10−10 M. The method was successfully applied to the detection of PPZ in urine sample. Cement-based electrode material may also find broad applications in electrochemistry industry, such as electrochemical wastewater treatment.  相似文献   

19.
《Analytica chimica acta》2004,506(1):71-80
We describe an estimation of measurement uncertainty calculated by the “bottom-up” approach for the determination of the oestrogenic compound nonylphenol in treated water samples by solid-phase extraction (SPE) and solid-phase microextraction (SPME) procedures and GC/MS detection. The results were compared and the different contributions to the uncertainty were evaluated. A study of the linear range was established and validation was performed for both methods using statistical analysis of several indicative parameters. In terms of validation data, precision (R.S.D. values <20%) and trueness (relative error <11%) were obtained for both methods under day-to-day conditions. The results of the estimation of measurement uncertainty obtained for both methods for concentrations higher than 1 μg/l have demonstrated that the time-consuming SPE method has a lower relative uncertainty (32%) than the SPME method (42.8%). The chromatographic uncertainty value was the main factor in the SPME method whereas the recovery factor (used to calculate the concentration) was the main contribution to uncertainty in the SPE method.  相似文献   

20.
Exposure to fragrance substances is exponentially increasing in our daily life due to the enhanced use of scented products. Some fragrances are known to be important sensitizers, inhalation being an important exposure pathway in indoor environments. A simple and sensitive method based on solid-phase enrichment and solid-phase microextraction (SPME) followed by gas chromatography–mass spectrometry (GC–MS) has been developed for the analysis of 24 volatile fragrance allergens in indoor air. Suspected allergens present in the air (0.2 m3) were adsorbed onto a very small quantity of florisil (25 mg) and then transferred to a SPME fiber in the headspace mode (HS). To the best of our knowledge, this paper describes the first application of SPME for the determination of these compounds in air samples. The experimental parameters affecting the microextraction process have been optimized using a multifactor experimental design strategy. Accuracy, linearity, precision and detection limits (LODs) were evaluated to assess the performance of the proposed method. External calibration, using spiked sorbent standards, and not requiring the complete sampling process (only the SPME step), demonstrated to be suitable for the quantification of all suspected allergens. Recovery studies were performed at three concentration levels (0.04, 1.00 and 50 μg m−3), obtaining quantitative recoveries (≥85%) in most cases. LOD values at the low ng m−3 level were achieved for all the target compounds. The application of the method to daily home air samples demonstrated the ubiquity of this kind of fragrance ingredients in quotidian indoor environments, finding 18 of the 24 considered compounds in concentrations ranging from 0.01 to 56 μg m−3. Benzyl alcohol, linalool, citronellol, ionone and lilial were found in most analyzed samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号