首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chen WH  Lin CC  Chen TS  Misra TK  Liu CY 《Electrophoresis》2003,24(6):970-977
The parameters influencing the electrochromatographic separation of aliphatic organic acids in a capillary column with a wall-coated macrocyclic polyamine have been studied. Indirect detection using chromate, pyromellitate, trimellitate, o-phthalate, benzoate and acetate as background electrolytes has been tested. A complete separation of polyprotic acids could be achieved with pyromellitate buffer (7.5 mM, pH 6.5), and satisfactory results for the simultaneous separation of monoprotic acids and polyprotic acids were found using a capillary column of 70 cm (50 cm effective length)x75 microm inner diameter, electrokinetic injection (-10 kV, 10 s), benzoate buffer (6 mM, pH 4.6), separation voltage of -10 kV, and detection at 220 nm. For the separation of the geometric isomers fumarate and maleate, acetate buffer was found the best choice among the background electrolytes tested. The method so established has been applied to the determination of organic acids in soy sauce, brandy, lemon juice, spinach juice and cigarette. From the retention behavior, it was found that the separation mechanism on the bonded phase was influenced by the macrocyclic effect, electrostatic attraction, hydrogen bonding, van der Waals forces, and anion exchange, in addition to the differences in electrophoretic mobility.  相似文献   

2.
An analytical approach of the 32-membered macrocyclic polyamine, 1,5,9,13,17,21,25,29-octaazacyclodotriacontane ([32]ane-N8) was described for the capillary electrochromatographic (CEC) separation of derivatized mono- and disaccharides. The column displayed reversal electroosmotic flow (EOF) at pH below 7.0, while a cathodic EOF was shown at pH above 7.0. The reductive amination of saccharides was carried out with p-aminobenzoic acid. Some parameters that affect the CEC separations were investigated. Several competitive ligands, such as Tris, EDTA and phosphate were also examined for the effect on the performance. We achieved a complete separation of all compounds as well as the excess derivatizing agent by using borate buffer (pH 9.0) in a mode of concentration gradient (60 mM inlet side and 70 mM outlet side). The relative standard deviation of the retention time measured for each sample was less than 4% in six continuous runs, suggesting that the bonded phase along with the gradient formed inside the column was quite stable. With the mixing modes of anion coordination, anion exchange, and shape discrimination, the interaction adequately accomplishes the separation of carbohydrates which are epimers or have different glycosidic linkage, although the electrophoretic migration is also involved in the separation mechanism.  相似文献   

3.
An imidazole-coated capillary column for electrophoresis has been prepared by means of organosilanization. With mesityl oxide as neutral marker, the results indicated that the electroosmotic flow of the bonded phase displays a dramatic difference in pH dependence in comparison with that of the bare fused-silica column. The presence of positive charges on the coating surface and the anionic exchange property, due to the cationic property of the imidazole group at pH values below 6, allows the separation of geometric isomers that are very similar in ionic mobility. Separation parameters including buffer composition and concentration, pH, applied voltage, and the influence of other additives were investigated. By using acetate buffer (100 mM, pH 5.2) and an applied voltage of -15 kV with UV detection at 212 nm, the separation of 11 aromatic acids including mono-, di-, tri- and tetra-carboxylic acids could be achieved in less than 14 min. The average plate number was 3 x 10(5)/m. With acetate buffer (25 mM, pH 5.5) and an applied voltage of -25 kV, the addition of silver nitrate or beta-cyclodextrin significantly improved the resolution of some more highly charged carboxylic acids.  相似文献   

4.
Amino acid ionic liquids (AAILs) with l ‐lysine (l ‐Lys) as anion were synthesized and applied as new chiral ligands in Zn(II) complexes for chiral ligand‐exchange CE. After effective optimization, baseline enantioseparation of seven pairs of dansylated amino acids was achieved with a buffer of 100.0 mM boric acid, 5.0 mM ammonium acetate, 3.0 mM ZnSO4, and 6.0 mM [C6mim][l ‐Lys] at pH 8.2. To validate the unique behavior of AAILs, a comparative study between the performance of Zn(II)‐l ‐Lys and Zn(II)‐[C6mim][l ‐Lys] systems was conducted. In Zn(II)‐[C6mim][l ‐Lys] system, it has been found that the improved chiral resolution could be obtained and the migration times of the three test samples were markedly prolonged. Then the separation mechanism was further discussed. The role of [C6mim][l ‐Lys] indicated clearly that the synthesized AAILs could be used as chiral ligands and would have potential utilization in separation science in future.  相似文献   

5.
The use of a macrocyclic polyamine, 28[ane]-N6O2, as a selective modifier in a bonded-phase capillary column for the electrophoretic separation of 14 aromatic acids is described. Parameters that affect the performance of the separations, such as the type of buffer, the pH and concentration of buffer, the applied potential and the injection mode were studied. By changing the buffer pH (4.0-5.0), buffer concentration (10-50 mM) and applied potential (-10 approximately -20 kV), optimum conditions were obtained at -20 kV, using an acetate buffer (20 mM, pH 4.5), hydrodynamic injection with a vacuum at the buffer reservoir on the detector side and detection at 220 nm. The results showed that the separation was effective under these conditions. The plate number was greater than 4 x 10(4) m-l. Due to the wide variation in the mobilities of the test compounds, injection studies suggested that a vacuum at the buffer reservoir on the detector side would produce a result that is more representative of the initial sample composition. Benzoic acid in soy sauce, salicylic acid in Salic ointment and Aspirin were sampled and analyzed using the established conditions.  相似文献   

6.
An open tubular wall-coated capillary column containing histidine functional groups was prepared and employed for the capillary electrochromatographic separation of non-steroidal anti-inflammatory drugs. The anion exchange along with the hydrogen bonding and hydrophobic properties of the surface coating allowed the separation of analytes with very similar ionic mobility. Selectivity and resolution were studied by changing the pH over the range from 3.5 to 5.0 and the concentration of the buffer from 10 to 25 mM, as well as variation of the organic modifier, such as methanol, ethanol and 1-propanol over the range 7.5 to 20%. The optimum experimental conditions for the separation of a drug mixture, which consisted of indoprofen, ketoprofen, suprofen, naproxen, flurbiprofen, fenoprofen and ibuprofen were using a mixture of acetate buffer (20 mM, pH 5.0)-ethanol (1:5, v/v) as background electrolyte and an applied voltage of -20 kV with UV detection at 220 nm. The separation of these drugs could be achieved with an average plate number of 1.0 x 10(5) m(-1).  相似文献   

7.
In this work, the simultaneous enantioseparation of the second-generation antidepressant drug mirtazapine and its main metabolites 8-hydroxymirtazapine and N-desmethylmirtazapine by chiral CEC is reported. The separation of all enantiomers under study was achieved employing a capillary column packed with a vancomycin-modified diol stationary phase. With the aim to optimize the separation of the three pairs of enantiomers in the same run, different experimental parameters were studied including the mobile phase composition (buffer concentration and pH, organic modifier type and ratio, and water content), stationary phase composition, and capillary temperature. A capillary column packed with vancomycin mixed with silica particles in the ratio (3:1) and a mobile phase composed of 100 mM ammonium acetate buffer (pH 6)/H(2)O/MeOH/ACN (5:15:30:50, by vol.) allowed the complete enantioresolution of each pair of enantiomers but not the simultaneous separation of all the studied compounds. For this purpose, a packing bed composed of vancomycin-CSP only was tested and the baseline resolution of the three couples of enantiomers was achieved in a single run in less than 30 min, setting the applied voltage and temperature at 25 kV and 20 degrees C, respectively. In order to show the potential applicability of the developed CEC method to biomedical analysis, a study concerning precision, sensitivity, and linearity was performed. The method was then applied to the separation of the enantiomers in a human urine sample spiked with the studied compounds after suitable SPE procedure with strong cation-exchange (SCX) cartridges.  相似文献   

8.
A high‐performance liquid chromatography method for simultaneous separation and determination of biogenic amines [dopamine, epinephrine, serotonin and its six metabolites (normetanephrine, metanephrine, 3,4‐dihydroxyphenylacetic acid, 4‐hydroxy‐3‐methoxyphenylglycol, homovanilic acid and 5‐hydroxyindoloacetic acid)] with drugs from different therapeutically groups [analgesics (paracetamol, metamizol), diuretics (furosemide) and antibiotics (cefazolin, fluconazole)] was developed. A chromatographic column with pre‐column with octadecylsilane phase (C18e) and two detectors – diode array serial connected and fluorescence – was used. Gradient elution of mixture of acetate buffer (pH 4.66) and methanol as a mobile phase was applied. The limit of detection (LOD) of 8–10 ng/mL and limit of quantitation (LOQ) of 24–30 ng/mL for biogenic amines, as well as the LOD of 50–100 ng/mL and the LOQ of 150–300 ng/mL for drugs, were determined. The applied sample preparation method allowed recoveries of 93% for the biogenic amines and 92% for the drugs to be achieved. The developed procedure has been applied to simultaneous determination of the examined compounds in urine samples and could be used in clinical analysis. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
In order to separate the potential arsenite metabolites methylarsonous acid and dimethylarsinous acid from arsenite, arsenate, methylarsonic acid and dimethylarsinic acid, the pH‐dependent retention behaviour of all six arsenic compounds was studied on a Hamilton PRP‐X100 anion‐exchange column with 30 mM phosphate buffers (pH 5, 6, 7, 8 and 9) containing 20% (v/v) methanol as mobile phase and employing an inductively coupled plasma atomic emission spectrometer (ICP–AES) as the arsenic‐specific detector. Baseline separation of dimethylarsinic acid, methylarsonous acid, methylarsonic acid, arsenate and dimethylarsinous acid was achieved with a 30 mmol dm−3 phosphate buffer (pH 5)–methanol mixture (80:20, v/v) in 25 min. Arsenite is not baseline‐separated from dimethylarsinic acid under these conditions. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

10.
A bonded phase capillary column containing macrocyclic polyamine, [28]ane-N6O2 functional groups was used for the electrophoretic separation of arsenic, chromium and selenium species. A simple device interfacing this capillary electrochromatography (CEC) systems to an inductively coupled plasma mass spectrometer (ICPMS) is described. The dimension of the capillary column was 160 cm×100 μm i.d. To accommodate this electrophoretic separation, an auxiliary capillary was used with nitric acid (0.05 M) as makeup liquid. With the electrokinetic method at –20 kV, 20 s and a nebulizer gas flow rate of 1 l min−1, the sample injected was analyzed with an applied potential of −20 kV. The background electrolyte buffer for the separation of CrO42−–Cr3+ was phosphate (20 mM, pH 6.5). That for HAsO42−–Ph4As+ was pyromellitate (20 mM, pH 6.0) and for SeO42−–SeO32− was acetate (20 mM, pH 6.0). The role of the buffer’s anion was also discussed. The separation efficiency of the bonded phase was compared with the bare fused silica. Concentration detection limits for these metal ions were in the low ppb range. In addition, the matrix effect of the established system with the bonded phase was found smaller than that with the bare fused silica.  相似文献   

11.
A rapid, sensitive and specific assay for 9-chloro-2-(2-furyl) [1,2,4]triazolo[1,5-c]quinazolin-5-imine (I) and its oxo metabolite (II) in plasma was developed and validated employing reversed-phase high-performance liquid chromatography with fluorescence detection. Sample preparation was achieved by a simple ethyl acetate extraction from plasma buffered at pH 10 (0.1 M boric acid-0.1 M potassium chloride). Chromatographic analyses were performed isocratically on a C18 column, with a mobile phase consisting of methanol-0.2 M sodium acetate buffer, pH 5.0 (67:33, v/v). Chromatographic run time was less than 8 min. The assay was linear (r greater than 0.9998) over the concentration range 1.50-10,000 ng/ml for both I and II; for individual studies, curves covering a range of two orders of magnitude were generally employed. Limits of detection for I and II were 0.5 and 1.0 ng/ml, respectively. A preliminary investigation of the plasma concentrations of I and II in the rat following a single 30 mg/kg oral dose demonstrated the applicability of the method for pharmacokinetic studies.  相似文献   

12.
Reversed-phase liquid chromatography using cupferron as a precolumn derivatizing agent was developed for the determination of Cu(II) and Fe(III) in biological materials and natural water samples. In the direct method, the metal cupferronates formed in acetonitrile-water (1 + 1) are injected onto an ODS column followed by separation with a mobile phase containing acetonitrile-acetate buffer (pH 3.5) (7 + 3) and other reagents. Amperometric detection with a glassy carbon electrode at ?0.40 V vs. Ag/AgCl can be used to determine both metals simultaneously. The electrochemical detection method has better sensitivity for the determination of Fe(III) than the usual spectrophotometric detection at 375 nm. If a large volume of aqueous sample is available, concentration of the two metal ions can be made by extraction with ethyl acetate prior to the chromatographic determination. In this case, liquid chromatographic separation and determination can be performed with the ODS column using a mobile phase consisting of acetonitrile-methanol-ethyl acetate-0.02 M acetate buffer (pH 3.5) (45 + 20 + 5 + 30).  相似文献   

13.
The separation of several insect oostatic peptides (IOPs) was achieved by using CEC with a strong-cation-exchange (SCX) stationary phase in the fused-silica capillary column of 75 microm id. The effect of organic modifier, ionic strength, buffer pH, applied voltage, and temperature on peptides' resolution was evaluated. Baseline separation of the studied IOPs was achieved using a mobile phase containing 100 mM pH 2.3 sodium phosphate buffer/water/ACN (10:20:70 v/v/v). In order to reduce the analysis time, experiments were performed in the short side mode where the stationary phase was packed for 7 cm only. The selection of the experimental parameters strongly influenced the retention time, resolution, and retention factor. An acidic pH was selected in order to positively charge the analyzed peptides, the pI's of which are about 3 in water buffer solutions. A good selectivity and resolution was achieved at pH <2.8; at higher pH the three parameters decreased due to reduced or even zero charge of peptides. The increase in the ionic strength of the buffer present in the mobile phase caused a decrease in retention factor for all the studied compounds due to the decreased interaction between analytes and stationary phase. Raising the ACN concentration in the mobile phase in the range 40-80% v/v caused an increase in both retention factor, retention time, and resolution due to the hydrophilic interactions of IOPs with free silanols and sulfonic groups of the stationary phase.  相似文献   

14.
An ion-interaction reversed-phase liquid chromatographic method has been developed for the determination of cadmium at low microg/l concentrations in environmental water samples. Cadmium and other matrix metals were separated through on-column complexation with 8-hydroxyquinoline sulphonate, using an octadecylsilica column and a mobile phase containing 15% acetonitrile, 10-13 mM tetrabutylammonium hydroxide, 5 mM 8-hydroxyquinoline 5-sulphonic acid and 10 mM acetic acid-acetate buffer (pH 4.8-5.4). Under the above conditions Cd(II) could be easily resolved from excess concentrations of matrix metals and could be detected at concentrations as low as 2 microg/l using fluorescence detection at 500 nm (based upon a 100-microl injection). The method showed a slightly curved detector response over the range of interest [up to 1 mg/l Cd(II)] and was successfully applied to the determination of trace Cd(II) in water samples containing large excesses of Mg(II) and Zn(II) and other matrix metals.  相似文献   

15.
In the present work, a 2-D capillary liquid chromatography method for fractionation and separation of human salivary proteins is demonstrated. Fractionation of proteins according to their pI values was performed in the 1-D employing a strong anion exchange (SAX) column subjected to a wide-range descending pH gradient. Polystyrene-divinylbenzene (PS-DVB) RP columns were used for focusing and subsequent separation of the proteins in the 2-D. The SAX column was presaturated with a high pH buffer (A) consisting of 10 mM amine buffering species, pH 9.0, and elution was performed with a low pH elution buffer (B) having the same buffer composition and concentration as buffer A, but pH 3.5. Isoelectric point fractions eluting from the 1-D column were trapped on PS-DVB trap columns prior to back-flushed elution onto the PS-DVB analytical column for separation of the proteins. The 1-D fraction eluting at pH 9.0-8.7 was chosen for further analysis. After separation on the RP analytical column, nine RP protein fractions were collected and tryptic digested for subsequent analyses by MALDI TOF MS and column switching capillary LC coupled to ESI TOF MS and ESI QTOF MS. Eight proteins and two peptides were identified in the pH 9.0-8.7 fraction using peptide mass fingerprinting and uninterpreted MS/MS data.  相似文献   

16.
A method has been developed for the separation of Fe(II)-1,10-phenanthroline and Fe(III)-5-sulphosalicylate complexes on a reversed-phase C18 column in the presence of an ion-pairing reagent. Samples were injected on the column in the pre-complexed form and separated using a mobile phase consisting of acetonitrile [0.1% (w/v) in 5-sulphosalicylic acid] ?0.02 M sodium acetate buffer (pH 6.9) [0.1% (w/v) in tetramethylammonium chloride] (1 + 1). Spectrophotometric detection of the complexes was carried out at 515 nm. Linear calibration graphs were obtained for 1–12 μg mol?1 Fe(II) and Fe(III).  相似文献   

17.
The performance of isocratic separations of 11 pollutant phenols (PP) using monolithic (Chromolith RP-18e) and conventional reversed-phase 5 microm (Luna and Purospher C18) and 4 microm (Synergi C12) particulate size columns, selected from high purity silica materials, has been compared. The separations have been optimized based on a previously optimized separation in which a reversed-phase C18 Luna column and acetonitrile as organic modifier were used, allowing the separation of all phenols tested in 23 min. The optimization process was carried out for each column by studying the effect of the mobile phase (acetonitrile as organic modifier, pH, flow-rate) on phenols separation. Under the optimized separation conditions, all phenols were separated in less than 23 min for all columns tested. Asymmetry factors were further evaluated and used to estimate column efficiency using the Dorsey-Foley equation. The efficiency and asymmetry factors were lower for Chromolith than for Purospher and Luna columns respectively. The Chromolith column was finally selected, due to its lower flow resistance, analysis time and good efficiency and asymmetry factors. The PPs separation was achieved in 3 min. The asymmetry factors were in the range 0.9-1.5 using 50mM acetate buffer (pH = 5.25)-ACN (64:36, v/v) as mobile phase, T=45 degrees C and 4.0 ml min(-1) flow-rate.  相似文献   

18.
Qi L  Chen Y  Xie M  Guo Z  Wang X 《Electrophoresis》2008,29(20):4277-4283
A facile chiral ligand-exchange capillary electrophoretic method has been explored for the enantioseparation and UV detection of dansyl-amino acids with Zn(II) L-arginine complex as a chiral selecting system. Successful enantioseparation of 17 pairs of amino acid enantiomers has been achieved with a buffer of 100 mM boric acid, 5 mM ammonium acetate, 3 mM ZnSO4 and 6 mM L-Arg at pH 8.0, of which 10 pairs were fully resolved with resolution in between 1.59 and 4.21. This new method was shown to be applicable to the separation of some mixed pairs of amino acids and to the quantitative analysis of some real samples such as rice vinegars, with a linear range between 0.8 and 150 microg/mL, correlation coefficient above 0.99 and recovery in between 90.1 and 112.4%. It was found that amino acids with low resistance side chain(s), low tendency to form intramolecular hydrogen bond or high tendency to form intermolecular hydrogen bonds are more easily enantioseparated than those with extra carboxyl and/or phenyl groups. By the use of the suggested buffer, the running pH should be selected at 7.4-9.0 to compromise the resolution and elution speed.  相似文献   

19.
A nanoliquid chromatographic method for the stereoisomer separation of some flavanone aglycones and 7‐O‐glycosides has been proposed employing a C18 capillary column and a chiral mobile‐phase additive such as cyclodextrin. The chiral separation of eriodictyol, naringenin, and hesperitin was obtained by addition of carboxymethyl‐β‐cyclodextrin to the mobile phase, whereas eriocitrin, naringin, narirutin, and hesperidin diastereoisomers were resolved by using sulfobutyl ether‐β‐cyclodextrin. The influence of the composition of the mobile phase, the length of the capillary column, and the flow rate on the chiral recognition were investigated. At optimum conditions, baseline separation for the selected aglycones and glycosylated forms were achieved with a mobile phase consisting of 50 mM sodium acetate buffer pH 3 and 30% methanol containing 20 mM of carboxymethyl‐β‐cyclodextrin and 10 mM of sulfobutyl ether‐β‐cyclodextrin, respectively. Precision, linearity, and sensitivity of the method were tested. Limits of detection and quantification for the studied flavanone glycosides were in the range 1.3‐2.5 and 7.5‐12.5 µg/mL, respectively. The method was used for the determination of the diastereomeric composition of the flavanone‐7‐O‐glycosides in Citrus juices after solid‐phase extraction procedure.  相似文献   

20.
A monolithic column was prepared using l-phenylalanine as template and a covalent approach through the formation of Schiff base with o-phthalaldehyde (OPA). OPA, allylmercaptan, l-phenylalanine, and triethylamine were stirred at first, then methacrylic acid, 2-vinylpyridine, ethyleneglycol dimethacrylate, α,α-azobisisobutyronitrile, and 1-propanol were added to the reaction mixture. The resulting material was introduced into a capillary column. Following thermal polymerization, the template was then extracted with a mixture of HCl and methanol. The column was employed for the capillary electrochromatographic separation of oligopeptides. A capillary column of 75 (50) cm × 75 μm ID with a mobile phase of phosphate buffer (pH 7.0, 40 mM)/methanol (5%, v/v), an applied voltage of +15 kV, and detection at 214 nm, could baseline separate angiotensin I, angiotensin II, [Sar1, Thr8] angiotensin, oxytocin, vasopressin, tocinoic acid, β-casomorphin bovine, β-casomorphin human, and FMRF amide within 20 min. The separation behavior of the templated polymer was also compared with that of the non-templated polymer. As a result, it can be concluded that the electrochromatographic separation of this set of peptides was mediated by a combination of electrophoretic migration and chromatographic retention involving hydrophobic, hydrogen bonding, electrostatic as well as the Schiff base formation with OPA in the cavity of the templated polymer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号