首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Liu C  Djuth F  Li X  Chen R  Zhou Q  Shung KK 《Ultrasonics》2012,52(4):497-502
This paper reports the design, fabrication, and performance of miniature micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular arrays. The PMN-PT single crystal 1-3 composites were made with micromachining techniques. The area of a single crystal pillar was 9 × 9 μm. The width of the kerf among pillars was ∼5 μm and the kerfs were filled with a polymer. The composite thickness was 25 μm. A six-element annular transducer of equal element area of 0.2 mm2 with 16 μm kerf widths between annuli was produced. The aperture size the array transducer is about 1.5 mm in diameter. A novel electrical interconnection strategy for high density array elements was implemented. After the transducer was attached to the electric connection board and packaged, the array transducer was tested in a pulse/echo arrangement, whereby the center frequency, bandwidth, two-way insertion loss (IL), and cross talk between adjacent elements were measured for each annulus. The center frequency was 50 MHz and −6 dB bandwidth was 90%. The average insertion loss was 19.5 dB at 50 MHz and the crosstalk between adjacent elements was about −35 dB. The micromachining techniques described in this paper are promising for the fabrication of other types of high frequency transducers, e.g. 1D and 2D arrays.  相似文献   

2.
The integral equations that describe scattering in the media with step-rise changing parameters have been numerically solved for the trabecular bone model. The model consists of several hundred discrete randomly distributed elements. The spectral distribution of scattering coefficients in subsequent orders of scattering has been presented. Calculations were carried on for the ultrasonic frequency ranging from 0.5 to 3 MHz. Evaluation of the contribution of the first, second, and higher scattering orders to total scattering of the ultrasounds in trabecular bone was done. Contrary to the approaches that use the μCT images of trabecular structure to modeling of the ultrasonic wave propagation condition, the 3D numerical model consisting of cylindrical elements mimicking the spatial matrix of trabeculae, was applied. The scattering, due to interconnections between thick trabeculae, usually neglected in trabecular bone models, has been included in calculations when the structure backscatter was evaluated. Influence of the absorption in subsequent orders of scattering is also addressed. Results show that up to 1.5 MHz, the influence of higher scattering orders on the total scattered field characteristic can be neglected while for the higher frequencies, the relatively high amplitude interference peaks in higher scattering orders clearly occur.  相似文献   

3.
Omari E  Lee H  Varghese T 《Ultrasonics》2011,51(6):758-767
Quantitative ultrasound features such as the attenuation slope, sound speed and scatterer size, have been utilized to evaluate pathological variations in soft tissues such as the liver and breast. However, the impact of variations in the sound speed and backscatter due to underlying fat content or fibrotic changes, on the attenuation slope has not been addressed. Both numerical and acoustically uniform tissue-mimicking experimental phantoms are used to demonstrate the impact of sound speed variations on attenuation slope using clinical real-time ultrasound scanners equipped with linear array transducers. Radiofrequency data at center frequencies of 4 and 5 MHz are acquired for the experimental and numerical phantoms respectively. Numerical phantom sound speeds between 1480 and 1600 m/s in increments of 20 m/s for attenuation coefficients of 0.3, 0.4, 0.5, 0.6, and 0.7 dB/cm/MHz are simulated. Variations in the attenuation slope when the backscatter intensity of the sample is equal, 3 dB higher, and 3 dB lower than the reference is also evaluated. The sound speed for the experimental tissue-mimicking phantoms were 1500, 1540, 1560 and 1580 m/s respectively, with an attenuation coefficient of 0.5 dB/cm/MHz. Radiofrequency data is processed using three different attenuation estimation algorithms, i.e. the reference phantom, centroid downshift, and a hybrid method. In both numerical and experimental phantoms our results indicate a bias in attenuation slope estimates when the reference phantom sound speed is higher (overestimation) or lower (underestimation) than that of the sample. This bias is introduced via a small spectral shift in the normalized power spectra of the reference and sample with different sound speeds. The hybrid method provides the best estimation performance, especially for sample attenuation coefficient values lower than that of the reference phantom. The performance of all the methods deteriorates when the attenuation coefficient of the reference phantom is lower than that of the sample. In addition, the hybrid method is the least sensitive to sample backscatter intensity variations.  相似文献   

4.
A pilot study was carried out to investigate the performance of ultrasound stiffness imaging methods namely Ultrasound Elastography Imaging (UEI) and Acoustic Radiation Force Impulse (ARFI) Imaging. Specifically their potential for characterizing different classes of solid mass lesions was analyzed using agar based tissue mimicking phantoms. Composite tissue mimicking phantom was prepared with embedded inclusions of varying stiffness from 50 kPa to 450 kPa to represent different stages of cancer. Acoustic properties such as sound speed, attenuation coefficient and acoustic impedance were characterized by pulse echo ultrasound test at 5 MHz frequency and they are ranged from (1564 ± 88 to 1671 ± 124 m/s), (0.6915 ± 0.123 to 0.8268 ± 0.755 db cm-1 MHz-1) and (1.61×106 ± 0.127 to 1.76 × 106 ± 0.045 kg m-2 s-1) respectively. The elastic property Young’s Modulus of the prepared samples was measured by conducting quasi static uni axial compression test under a strain rate of 0.5 mm/min upto 10 % strain, and the values are from 50 kPa to 450 kPa for a variation of agar concentration from 1.7% to 6.6% by weight. The composite phantoms were imaged by Siemens Acuson S2000 (Siemens, Erlangen, Germany) machine using linear array transducer 9L4 at 8 MHz frequency; strain and displacement images were collected by UEI and ARFI. Shear wave velocity 4.43 ± 0.35 m/s was also measured for high modulus contrast (18 dB) inclusion and X.XX m/s was found for all other inclusions. The images were pre processed and parameters such as Contrast Transfer Efficiency and lateral image profile were computed and reported. The results indicate that both ARFI and UEI represent the abnormalities better than conventional US B mode imaging whereas UEI enhances the underlying modulus contrast into improved strain contrast. The results are corroborated with literature and also with clinical patient images.  相似文献   

5.
The present article describes novel highly nonlinear photonic crystal fibers (HN-PCFs) with flattened chromatic dispersion and low confinement losses. The proposed design has been simulated based on the finite-difference method with anisotropic perfectly matched layers absorbing boundary condition. It is proved that the design novel HN-PCFs is obtained a nonlinear coefficient greater than 45 W−1 km−1 and low dispersion slope −0.009 ps/(nm2.km) at 1.55 μm wavelength. In addition, results from numerical simulation show that the ultra-flattened dispersion of 0 ± 0.65 ps/(nm.km) can be obtained in a 1.36-1.62 μm wavelength range with confinement losses lower than 10−7 dB/m in the same wavelength range. Another advantage of the proposed HN-PCFs is that it possessed modest number of design parameters.  相似文献   

6.
The dielectric anisotropy and dispersion of the real and imaginary part of permittivity of commercially important nematic mixture E-24 were investigated in the frequency range from 1 kHz to 10 MHz and temperature range 287-328 K. The measurements in nematic phase indicate Debye-type dispersion with relaxation time of 1.07 μs at 313 K and activation energy 41.01 kcal/mol. The results have been explained by assuming the molecular rotation about the long molecular axis under a hindering nematic potential. The dielectric anisotropy Δε is positive and the mean dielectric permittivity falls with rising temperature. Δε is also used to determine the order parameter for varying temperature.  相似文献   

7.
In this paper, a novel dispersion-shifted multi-clad optical fiber with very small bending loss and ultra-high bit-rate applicable for large capacity information transmission systems is presented. To decrease dispersion and higher-order dispersion effects at λ = 1.55 μm, a weighted pulse broadening factor and genetic algorithm (GA) optimization technique is used. Compared to the works reported previously, this method can precisely set the zero-dispersion wavelength. This kind of dispersion-shifted fibers has dispersion, dispersion slope, mode field diameter (MFD), effective area and quality factor within −1.40 × 10−4 to −8.44 × 10−2 ps/km nm, 3.06 × 10−2 to −4.07 × 10−2 ps/km nm2, 5.56−5.85 μm, 119.25−176.42 μm2 and 3.49-5.27 at λ = 1.55 μm, respectively. Besides, by applying dispersion at λ = 1.55 μm as the cost function, dispersion of about 1.31 × 10−8 ps/km nm is obtained. Thus, this novel optical fiber can be used in long-haul high information-transmission capacity communication systems.  相似文献   

8.
A 980 nm bottom-emitting vertical-cavity surface-emitting laser (VCSEL) array with a nonuniform linear arrangement is reported to realize high power with a Gaussian far-field distribution. This array is composed of five symmetrically-arranged elements of 200 μm, 150 μm, and 100 μm diameters, with the center spacing of 300 μm and 250 μm respectively. This structure makes it possible to discriminate against the higher order array supermodes. The theoretical simulation of the far-field distribution is in good agreement with the experimental result. An output power of 880 mW with a power density of 1 KW/cm2 is obtained. The divergence angle is below 20° in the range of operating current from 0 A to 4 A. The comparison between this nonuniform linear array and the conventional two-dimensional array is carried out to demonstrate the good performance of the linear array. A peak power of over 20 W is achieved under a short pulsed operation with a repetition frequency of 1 kHz.  相似文献   

9.
We demonstrate novel photonic-crystal fibers (PCFs) fabricated of a highly nonlinear glass. Dispersion profiles and nonlinearity of these fibers are tailored with an array of submicron holes in the fiber core. With the PCF structure designed to provide a nonlinearity on the order of 103 W−1 km−1 at the radiation wavelength of 1 μm and a fundamental-mode dispersion profile with zero group-velocity dispersion around 1.19 μm, unamplified femtosecond Cr: forsterite laser pulses are efficiently frequency-converted into the 540-1000-nm wavelength range through solitonic spectral-transformation mechanisms and four-wave mixing.  相似文献   

10.
A model of ultrasonic backscattering for cancellous bone saturated by water is proposed. This model assumes that scattering is caused by the solid trabeculae and describes the cancellous bone as a weak scattering medium. The backscatter coefficient is related to the spatial Fourier transform of bone microarchitecture and to the density and compressibility fluctuations between the solid trabeculae and the saturating fluid. The computations of the model make use of three-dimensional numerical images of bone microarchitecture, obtained by tomographic reconstructions with a 10 microm spatial resolution. With this model, the predictions of the frequency dependence and of the magnitude of the backscatter coefficient are reasonably accurate. The theoretical predictions are compared to experimental data obtained on 19 specimens. An accuracy error of approximately 1 dB was found (difference between the averaged experimental values and theoretical predictions). One limit of the model may come from inaccurate values of trabecular bone characteristics needed for the computations (density and longitudinal velocity), which are yet to be precisely determined for human trabecular bone. However, the model is only slightly sensitive to variations of bone material properties. It was found that an accuracy error of 2.2 dB at maximum resulted from inaccurate a priori values of bone material properties. A computation of the elastic mean free path in the medium suggests that multiple scattering plays a minor role in the working frequency bandwidth (0.4-1.2 MHz). It follows from these results that a weak scattering medium model may be appropriate to describe scattering from trabecular bone.  相似文献   

11.
In this paper, we proposed a dual-enhanced core photonic crystal fiber (PCF) with high birefringence and ultra-high negative dispersion for dispersion compensation in a polarization maintained optical system. Using finite difference time domain (FDTD) method, we presented dispersion compensating PCF (DC-PCF) with negative dispersion between −1650 ps nm−1 km−1 and −2305 ps nm−1 km−1 in C-band and particularly −2108 ps nm−1 km−1 in λ = 1.55 μm wavelength. By this method, we can compensate dispersion in 124 km long span of a conventional single mode fiber (SMF) by 1 km-long of the DC-PCF at λ = 1.55 μm wavelength. Moreover, fundamental mode of the proposed PCF can induce birefringence about 3.5 × 10−3 at 1.55 μm wavelength.  相似文献   

12.
This paper presents a dispersion compensating microstructure holey fiber for wideband transmission system. The finite element method with perfectly matched absorbing layers boundary condition is used to investigate the guiding properties. According to simulation, negative dispersion coefficient of −1455 ps/(nm km) and a relative dispersion slope (RDS) close to that of single mode fiber of about 0.0036 nm−1 is obtained at 1.55 μm. The variation of structural parameters is also studied to evaluate the tolerance of the fabrication. The proposed module can be used in 40 Gb/s dense wavelength division multiplexing (DWDM) systems in optical fiber communication networks.  相似文献   

13.
A model describing the frequency dependence of backscatter coefficient from trabecular bone is presented. Scattering is assumed to originate from the surfaces of trabeculae, which are modeled as long thin cylinders with radii small compared with the ultrasonic wavelength. Experimental ultrasonic measurements at 500 kHz, 1 MHz, and 2.25 MHz from a wire target and from trabecular bone samples from human calcaneus in vitro are reported. In both cases, measurements are in good agreement with theory. For mediolateral insonification of calcaneus at low frequencies, including the typical diagnostic range (near 500 kHz), backscatter coefficient is proportional to frequency cubed. At higher frequencies, the frequency response flattens out. The data also suggest that at diagnostic frequencies, multiple scattering effects on the average are relatively small for the samples investigated. Finally, at diagnostic frequencies, the data suggest that absorption is likely to be a larger component of attenuation than scattering.  相似文献   

14.
A new nonlinear dispersion flattened photonic crystal fiber with low confinement loss is proposed. This fiber has threefold symmetry core. The doped region in the core and the big air-holes in the 1st ring can make high nonlinearity in the PCF. And the small air-holes in the 1st ring and the radial increasing diameters air-holes rings in cladding can be used to achieve the dispersion properties of the PCF. We can achieve the optimized optical properties by carefully selecting the PCFs structure parameters. A PCF with flattened dispersion is obtained. The dispersion is less than 0.8 ps/(nm km) and is larger than −0.7 ps/(nm km) from 1.515 μm to 1.622 μm. The nonlinear coefficient is about 12.6456 W−1 km−1, the fundamental mode area is about 10.2579 μm2. The confinement loss is 0.30641 dB/km. This work may be useful for effective design and fabrication of dispersion flattened photonic crystal fibers with high nonlinearities.  相似文献   

15.
Two-sample (Allan) variance with a modified algorithm was applied to the determination of the experimental linewidth of a thermoelectrically-cooled continuous-wave distributed feedback quantum cascade laser at a wavelength of 4.333 μm. From successive laser transmittance scans over the CO2 ν3, (0111 − 0110) P(33) absorption line at 2307.653 cm− 1, two-sample variances were calculated for the laser frequency difference between different points on the sides of the absorption peak. From the minimum two-sample variance of the laser frequency difference between two adjacent points (5 μs between the points) on the same side of the absorption line the experimental laser linewidth was estimated to be less than 36(7) kHz at a laser power of ~ 25 mW, a laser current of 976 mA and a laser temperature of + 19.5 °C.  相似文献   

16.
Sandeep K. Arya  R.A. Agarwala 《Optik》2009,120(8):364-369
In this paper, the impact of second-order dispersion (2OD), third-order dispersion (3OD) and modulation frequency over stimulated Raman scattering (SRS)- and cross-phase modulation (XPM)-induced crosstalk in sub-carrier-multiplexed (SCM) wavelength division multiplexed (WDM) transmission link has been analyzed. It has been observed that there is significant effect of 2OD, 3OD and modulation frequency on the SRS- and XPM-induced crosstalk in a SCM-WDM transmission link. Here the results for SRS- and XPM-induced crosstalk have been reported with independent and combined higher-order dispersion. It has been observed that XPM-induced crosstalk lies between [−52.8 to −45.3] and [−94.7 to −78.6] dB in the presence of 2OD and 3OD respectively for modulation frequencies varied from 500 MHz to 2.0 GHz, while it is in the range of [−94.4 to −84] and [−128.5 to −117] dB when both SRS and XPM are taken into consideration.  相似文献   

17.
Single-frequency diode lasers have been frequency stabilized to 1.5 kHz Allan deviation over 0.05-50 s integration times, with laser frequency drift reduced to less than 1.4 kHz/min, using the frequency reference provided by an ultranarrow inhomogeneously broadened Er3+:4I15/24I13/2 optical absorption transition at a vacuum wavelength of 1530.40 nm in a low-strain LiYF4 crystal. The 130 MHz full-width at half-maximum (FWHM) inhomogeneous line width of this reference transition is the narrowest reported for a solid at 1.5 μm. Strain-induced inhomogeneous broadening was reduced by using the single isotope 7Li and by the very similar radii of Er3+ and the Y3+ ions for which it substitutes. To show the practicability of cryogen-free cooling, this laser stability was obtained with the reference crystal at 5 K; moreover, this performance did not require vibrational isolation of either the laser or crystal frequency reference. Stabilization is feasible up to T=25 K where the Er3+ absorption thermally broadens to ∼500 MHz. This stabilized laser system provides a tool for interferometry, high-resolution spectroscopy, real-time optical signal processing based on spatial spectral holography and accumulated photon echoes, secondary frequency standards, and other applications such as quantum information science requiring narrow-band light sources or coherent detection.  相似文献   

18.
In this paper, we numerically investigate and optimize the profile of a photonic crystal fiber (PCF) that can eliminate the residual dispersion from the telecom link as well as can provide identical dispersion compensation over S + C + L bands. A full-vectorial finite element method combined with genetic algorithm is used to optimize the fiber’s profile as well as to accurately determine its modal properties. The optimized PCF exhibits a dispersion of −98.3 ps/nm/km with a variance of ±0.55 ps/nm/km from 1.48 μm to 1.63 μm (i.e., over 150 nm bandwidth) and a zero dispersion slope. Macro-bending loss performance of the designed PCF is also studied and it is found that the fiber shows low bending losses for the smallest feasible bending radius of 5 mm. Further, sensitivity analysis has been carried out for the proposed fiber design and it has been found that a ±2% change in the fiber parameters may lead to a ±8% shift of the dispersion from its nominal value.  相似文献   

19.
The paper describes the investigations intended to compare the results of experimental measurements of backscattering properties of the trabecular bone with the results of computer simulations. Ultrasonic RF echoes were collected using two bone scanners operating at 0.58 and 1.3 MHz. The simulations of the backscattered RF echoes were performed using the scattering model of the trabecular bone that consisted of cylindrical and spherical elements uniformly distributed in water-like medium. For each measured or simulated RF backscatter the statistical properties of the signal envelope were determined. Experimental results suggest deviations of the backscattering properties from the Rayleigh distribution. The results of simulation suggest that deviation from Rayleigh distribution depends on the variation of trabeculae diameters and the number of thin trabeculae. Experimentally determined deviations corresponded well to the deviations calculated from simulated echoes assuming trabeculae thickness variation equaled to the earlier published histomorphometric study results.  相似文献   

20.
We oxidized a Ni/Au metal bi-layer contact fabricated on HVPE Al0.18Ga0.82N from 373 K to 573 K in 100 K steps. In the range 1 kHz to 2 MHz, the Capacitance–Voltage–Frequency (C–V–f) measurements reveal a frequency dispersion of the capacitance and the presence of an anomalous peak at 0.4 V owing to the presence of interface states in the as deposited contact system. The dispersion was progressively removed by O2 anneals from temperatures as low as 373 K. These changes are accompanied by an improvement in the overall quality of the Schottky system: the ideality factor, n, improves from 2.09 to 1.26; the Schottky barrier height (SBH), determined by the Norde [1] method, increases from 0.72 eV to 1.54 eV. From the Nicollian and Goetzberger model [2], we calculated the energy distribution of the density of interface states, NSS. Around 1 eV above the Al0.18Ga0.82N valence band, NSS, decreases from 2.3×1012 eV−1 cm−2 for the un-annealed diodes to 1.3×1012 eV−1 cm−2 after the 573 K anneal. Our results suggest the formation of an insulating NiO leading to a MIS structure for the oxidized Au/Ni/Al0.18Ga0.82N contact.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏