To reduce the size and the weight of heat exchangers, vortex generators (VGs) were punched on fin surface to improve the fin heat transfer performance. This paper is focused on the optimal fin spacing for three-row flat tube bank fin mounted with VGs. The results show, for commonly used fin materials and fin thickness, the optimal fin spacing is about 2 mm in industrial application for the configuration of tube bank fin studied.  相似文献   

2.
The results obtained from naphthalene sublimation heat/mass analogy experiments in selecting the optimum geometrical parameters of tube bank fin heat exchanger with fins mounted with vortex generators are compared with the results obtained from the condensing experiments of the real heat exchangers with vortex generators punched out on the fins. The results declare that VGs pouched or mounted on fin surfaces have only limited effects on heat transfer performance in the studied configurations; naphthalene sublimation method can be used to select fin patterns with reasonable reliability.  相似文献   

3.
Air-side heat transfer and friction characteristics of five kinds of fin-and-tube heat exchangers, with the number of tube rows (N = 12) and the diameter of tubes (Do = 18 mm), have been experimentally investigated. The test samples consist of five types of fin configurations: crimped spiral fin, plain fin, slit fin, fin with delta-wing longitudinal vortex generators (VGs) and mixed fin with front 6-row vortex-generator fin and rear 6-row slit fin. The heat transfer and friction factor correlations for different types of heat exchangers were obtained with the Reynolds numbers ranging from 4000 to 10000. It was found that crimped spiral fin provides higher heat transfer and pressure drop than the other four fins. The air-side performance of heat exchangers with the above five fins has been evaluated under three sets of criteria and it was shown that the heat exchanger with mixed fin (front vortex-generator fin and rear slit fin) has better performance than that with fin with delta-wing vortex generators, and the slit fin offers best heat transfer performance at high Reynolds numbers. Based on the correlations of numerical data, Genetic Algorithm optimization was carried out, and the optimization results indicated that the increase of VG attack angle or length, or decrease of VG height may enhance the performance of vortex-generator fin. The heat transfer performances for optimized vortex-generator fin and slit fin at hand have been compared with numerical method.  相似文献   

4.
In the present study, new experimental data on the air-side performance of fin-and-tube heat exchangers having herringbone wavy fin configuration are presented. Different from most previous studies, the present experiments have been performed to determine the effects of fin patterns and edge corrugations on the air-side performance of the heat exchangers. The experimental apparatus consists essentially of a well-insulated open wind tunnel and herringbone wavy fin-and-tube heat exchangers made from aluminium wavy finned, copper tube. Two types of wavy fin patterns commonly in industrial use are investigated. Air and hot water are used as working fluids in air-side and tube-side, respectively. From the experimental results, it is found that the fin pattern has a significant effect on the heat transfer and flow characteristics. The corrugation at the fin edge enables the Colburn factor to decrease but it has almost no effect on the friction factor.  相似文献   

5.
The present numerical study has dealt with the enhancement of latent heat Release by using plate type fins mounted on the vertical cooling surface in the rectangular vessel packed with molten salt as a latent heat storage material. It was found that the fin thickness and pitch exerted an influence on solidification heat transfer in a liquid layer of a nitric molten salt. The numerical results elucidated the flow pattern, velocity profile and heat transfer rate in the melted liquid layer.  相似文献   

6.
In real application, once the pattern of fin is determined, fin spacing of tube bank fin heat exchanger can be adjusted in a small region, and air flow velocity in the front of the heat exchanger is not all the same. Therefore, the effects of fin spacing on heat transfer performance of such heat exchanger are needed. This paper numerically studied the optimal fin spacing regarding the different front flow velocities of a circular tube bank fin heat exchanger with vortex generators. To screen the optimal fin spacing, an appropriate evaluation criterion JF was used. The results show that when front velocity is 1.75 m/s, the optimal fin spacing is 2.25 mm, when front velocity is 2.5 m/s, the optimal fin spacing is 2 mm, and when front velocity is higher than 2.5 m/s, the optimal fin spacing is 1.75 mm.  相似文献   

7.
In the present study, the potential of rectangular fins with 30° and 90° angle and 10 mm offset from the horizontal direction for heat transfer enhancement in a plate fin heat exchanger is numerically evaluated with conjugated heat transfer approach. The rectangular fins are mounted on the flat plate channel. The numerical computations are performed by solving a steady, three-dimensional Navier–Stokes equation and an energy equation by using Fluent software program. Air is taken as working fluid. The study is carried out at Re = 400 and inlet temperatures, velocities of cold and hot air are fixed as 300, 600 K and 1.338, 0.69 m/s, respectively. Colburn factor j versus Re design data is presented by using Fluent. The results show that the heat transfer is increased by 10 % at the exit of channel with fin angle of 30° when compared to channel without fin for counter flow. The heat transfer enhancement with fins of 30° and 90° for different values of Reynolds number with 300, 500 and 800 and for varying fin heights, fin intervals and also temperature distributions of fluids on the top and bottom surface of the channel are investigated for parallel and counter flow.  相似文献   

8.
Three dimensional numerical studies were performed for laminar heat transfer and fluid flow characteristics of wavy fin heat exchangers with elliptic/circular tubes by body-fitted coordinates system. The simulation results of circular tube were compared with the experiment data, then circular and elliptic (e = b/a = 0.6) arrangements with the same minimum flow cross-sectional area were compared. A max relative heat transfer gain of up to 30% is observed in the elliptic arrangement, and corresponding friction factor only increased by about 10%. The effects of five factors on wavy fin and elliptic tube heat exchangers were examined: Reynolds number (based on the smaller ellipse axis, 500  4000), eccentricity (b/a, 0.6  1.0), fin pitch (Fp/2b, 0.05  0.4), fin thickness (Ft/2b, 0.006  0.04) and tube spanwise pitch (S1/2b, 1.0  2.0). The results show that with the increasing of Reynolds number and fin thickness, decreasing of the eccentricity and spanwise tube pitch, the heat transfer of the finned tube bank are enhanced with some penalty in pressure drop. There is an optimum fin pitch (Fp/2b = 0.1) for heat transfer, but friction factor always decreases with increase of fin pitch. And when Fp/2b is larger than 0.25, it has little effects on heat transfer and pressure drop. The results were also analyzed from the view point of field synergy principle. It was found that the effects of the five factors on the heat transfer performance can be well described by the field synergy principle.  相似文献   

9.
This paper describes the development of an experimental facility to determine the heat transfer and flow friction characteristics of heat exchange surfaces by the modified single blow technique and the application of this transient technique to evaluate the performance characteristics of louvered fin heat exchangers. The reliability of implementing the modified single blow technique on the developed test facility is borne out by the good agreement in the heat transfer and flow friction data for the parallel plate test core when compared with theoretical and empirical correlations available in the literature. Performance evaluation of two louvered fin surfaces used mainly for cooling of large land and marine based electrical power generator sets is carried out and compared with similar louvered fin surfaces available in the literature. On the basis of dimensionless area and power factors, it was found that the flat fin is slightly superior in overall performance than its corrugated counterpart for low Reynolds numbers. Both surfaces are however inferior in performance when compared with the flat fin surface of Achaichia and Cowell and the corrugated fin surface of Davenport. Use of the j/f ratio as an approximate figure of merit led to an inaccurate assessment of the performance of the louvered fin heat exchanger surfaces evaluated in this study. Received on 8 May 1998  相似文献   

10.
This study examines the heat transfer enhancement from a horizontal rectangular fin embedded with triangular perforations (their bases parallel and toward the fin tip) under natural convection. The fin's heat dissipation rate is compared to that of an equivalent solid one. The parameters considered are geometrical dimensions and thermal properties of the fin and the perforations. The gain in the heat transfer enhancement and the fin weight reduction due to the perforations are considered. The study shows that the heat dissipation from the perforated fin for a certain range of triangular perforation dimensions and spaces between perforations result in improvement in the heat transfer over the equivalent solid fin. The heat transfer enhancement of the perforated fin increases as the fin thermal conductivity and its thickness are increased.  相似文献   

11.
In this paper, the semi-dimpled slit fin is proposed and the characteristics of heat transfer and fluid flow are analyzed based on the orthogonal experiment design method. A serial studies on the effects of fin pitch, arrangement of semi-dimple, dimple radius on heat transfer and flow characteristics of semi-dimpled slit fin are investigated. The computational results show fin pitch (Fp) has significantly effected on the performance of heat transfer and fluid flow, the influence of arrangement of semi-dimple, the dimple radius (R) and the opening direction of semi-dimples dwindle. At the same time, compared to the general semi-dimpled slit fin, the heat transfer coefficient and JF factors of the optimized fin increase by 10.7–25.1 and 2.6–7.7 %, respectively. When Re ≤ 1,521, the overall performance of slit fin is better than that of optimized fin; while Re > 1,521, the overall performance of optimized fin is better than that of slit fin. Finally, the performance evaluation plot of enhanced heat transfer of heat exchanger is applied to analyze the optimized fin, it can be seen that optimization fin have better heat transfer performance under the same power consumption.  相似文献   

12.
Longitudinal vortices disrupt the growth of the thermal boundary layer, thereby the vortex generators producing the longitudinal vortices are well known for the enhancement of heat transfer in compact heat exchangers. The present investigation determines the heat transfer characteristics with secondary flow analysis in plate fin triangular ducts with delta wing vortex generators. This geometrical configuration is investigated for various angles of attack of the wing i.e. 15°, 20°, 26° and 37° and Reynolds numbers 100 and 200. The constant wall temperature boundary condition is used. The solution of the complete Navier Stokes equation and the energy equation is carried out using the staggered grid arrangement. The performance of the combination of triangular secondary fins and delta wing with stamping on slant surfaces has also been studied. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
In the present study, the effects of fin thickness on the heat transfer and friction characteristics of fin-and-tube heat exchangers having herringbone wavy fin configuration are experimentally investigated. The experimental apparatus consists essentially of a well insulated open wind tunnel and herringbone wavy fin-and-tube heat exchangers made from aluminium plate finned, copper tube. Air and water are used to be working fluids in air-side and tube-side, respectively. A total of 10 samples of the fin-and-tube heat exchangers are tested. The experimental procedures are conducted by keeping the inlet water temperature at a pre-selected value, adjusting the water volumetric flow rate at a specific value and varying the air velocity. The results are presented as plots of the Colburn factor and friction factor against the Reynolds number based on the fin collar outside diameter (ReDc). From the results, it is found that for number of tube rows (N) = 2, the Colburn factor increases with increasing fin thickness. For N 4, the Colburn factor decreases with increasing fin thickness when ReDc < 1800, and increases with increasing fin thickness when ReDc > 2500. The friction factor increases with increasing fin thickness when fin pitch (Fp) 1.81 mm.  相似文献   

14.
The dominant thermal resistance for most compact heat exchangers occurs on the gas side and as such an understanding of the gas side flowfield is needed before improving current designs. Louvered fins are commonly used in many compact heat exchangers to increase the surface area and initiate new boundary layer growth. For this study, detailed flowfield measurements were made in the entry region of several louvered fin geometries whereby the louver angle, ratio of fin pitch to louver pitch, and Reynolds number were all varied. In addition to mean velocity measurements, time-resolved velocity measurements were made to quantify unsteady effects.

The results indicated larger fin pitches resulted in lower average flow angles in the louver passages and longer development lengths. Larger louver angles with a constant ratio of fin pitch to louver pitch resulted in higher average flow angles and shorter development lengths. As the Reynolds number increased, longer development lengths were required and higher average flow angles occurred as compared with a lower Reynolds number case. Time-resolved velocity measurements indicated some flow periodicity behind the fully developed louver for a range of Reynolds numbers. The Strouhal number of these fluctuations was constant for a given louver geometry, but the value increased with increasing fin pitch.  相似文献   


15.
The naphthalene sublimation method was used to study the effects of span position of vortex generators (VGs) on local heat transfer on three-row flat tube bank fin. A dimensionless factor of the larger the better characteristics, JF, is used to screen the optimum span position of VGs. In order to get JF, the local heat transfer coefficient obtained in experiments and numerical method are used to obtain the heat transferred from the fin. A new parameter, named as staggered ratio, is introduced to consider the interactions of vortices generated by partial or full periodically staggered arrangement of VGs. The present results reveal that: VGs should be mounted as near as possible to the tube wall; the vortices generated by the upstream VGs converge at wake region of flat tube; the interactions of vortices with counter rotating direction do not effect Nusselt number (Nu) greatly on fin surface mounted with VGs, but reduce Nu greatly on the other fin surface; the real staggered ratio should include the effect of flow convergence; with increasing real staggered ratio, these interactions are intensified, and heat transfer performance decreases; for average Nu and friction factor (f), the effects of interactions of vortices are not significant, f has slightly smaller value when real staggered ratio is about 0.6 than that when VGs are in no staggered arrangement. A cross section area of flow passage [m2] - A mim minimum cross section area of flow passage [m2] - a width of flat tube [m] - b length of flat tube [m] - B pT lateral pitch of flat tube: B pT = S 1/T p - d h hydraulic diameter of flow channel [m] - D naph diffusion of naphthalene [m2/s] - f friction factor: f = pd h/(Lu 2 max/2) - h mass transfer coefficient [m/s] - H height of winglet type vortex generators [m] - j Colburn factor [–] - JF a dimensionless ratio, defined in Eq. (23) [–] - L streamwise length of fin [m] - L PVG longitudinal pitch of vortex generators divided by fin spacing: L pVG = l VG/T p - l VG pitch of in-line vortex generators [m] - m mass [kg] - m mass sublimation rate of naphthalene [kg/m2·s] - Nu Nusselt number: Nu = d h/ - P pressure of naphthalene vapor [Pa] - p non-dimensional pitch of in-line vortex generators: p = l VG/S 2 - Pr Prandtl number [–] - Q heat transfer rate [W] - R universal gas constant [m2/s2·K] - Re Reynolds number: Re = ·u max·d h/ - S 1 transversal pitch between flat tubes [m] - S 2 longitudinal pitch between flat tubes [m] - Sc Schmidt number [–] - Sh Sherwood number [–]: Sh = hd h/D naph - Sr staggered ratio [–]: Sr = (2Hsin – C)/(2Hsin) - T p fin spacing [m] - T temperature [K] - u max maximum velocity [m/s] - u average velocity of air [m/s] - V volume flow rate of air [m3/s] - x,y,z coordinates [m] - z sublimation depth[m] - heat transfer coefficient [W/m2·K] - heat conductivity [W/m·K] - viscosity [kg/m2·s] - density [kg/m3] - attack angle of vortex generator [°] - time interval for naphthalene sublimation [s] - fin thickness, distance between two VGs around the tube [m] - small interval - C distance between the stream direction centerlines of VGs - p pressure drop [Pa] - 0 without VG enhancement - 1, 2, I, II fin surface I, fin surface II, respectively - atm atmosphere - f fluid - fin fin - local local value - m average - naph naphthalene - n,b naphthalene at bulk flow - n,w naphthalene at wall - VG with VG enhancement - w wall or fin surface  相似文献   

16.
 Natural convection heat transfer in rectangular fin-arrays mounted on a vertical base was investigated experimentally. An experimental set-up was constructed and calibrated to test 15 different fin configurations. Fin length and fin thickness were kept fixed at 100 and 3 mm respectively, while fin spacing was varied from 4.5 to 58.75 mm and fin height was varied from 5 to 25 mm. Base-to-ambient temperature difference was also varied through a calibrated wattmeter ranging from 10 to 50 W. The results showed that fin spacing is the most significant parameter in the performance of fin arrays; and for every fin height, for a given base-to-ambient temperature difference, there exists an optimum value for the fin spacing for which the heat transfer rate from the fin array is maximized. It was seen that higher heat transfer enhancement are obtained with vertically oriented bases than with horizontally oriented bases for fin arrays of the same geometry. Received on 16 February 2000  相似文献   

17.
Experiments were performed to investigate the effect of duct height on heat transfer enhancement of a surface affixed with arrays (7 × 7) of short rectangular plate fins of a co-rotating type pattern in the duct. An infrared imaging system is used to measure detailed distributions of the heat transfer at the endwall along with the fin base. An infrared camera of TVS 8000 with 160 × 120 point In–Sb sensor was used to measure the temperature distributions in order to calculate the local heat transfer coefficients of the representative fin regions. Pressure drop and heat transfer experiments were performed for a co-rotating fin pattern varying the duct height from 20?50 mm. The friction factor calculated from the pressure drop shows that comparatively larger friction occurs for the smaller duct cases and the friction factor slowly decreases with increasing Reynolds number. The effect of duct height on the area-averaged heat transfer results show that heat transfer initially increases with duct height and then finally decreases with increasing the duct height. Detailed heat transfer analysis and iso-heat transfer coefficient contour gives a clear picture of heat transfer characteristics of the overall surface. The relative performance graph indicates that a 25 mm duct is the optimum duct height for the highest thermal performance. In addition, a significant thermal enhancement, 2.8?3.8 times the smooth surface, can be achieved at lower Reynolds number with a co-rotating fin pattern in the duct.  相似文献   

18.
Heat transfer dissipation from a horizontal rectangular fin embedded with equilateral triangular perforations is computed numerically using one-dimensional finite element technique. The bases of the triangles are parallel and toward the fin base. The body of the fin is discretized into a number of subdivisions (finite elements). The number of these elements can be altered as required according to the automatic mesh generation. The heat dissipation of the perforated fin is computed and compared with that of the solid one of the same dimensions and same thermal properties. The comparison refers to acceptable results and heat dissipation enhancement due to certain perforation.  相似文献   

19.
The fin efficiency in a heat exchanger element that is a simplification of one row in a tube-and-fin heat exchanger was theoretically examined within wide ranges of the affecting variables: the conventional fin efficiency and the isothermal effectiveness of the heat exchanger. These variables are suggested for use also in the further studies. An analytical solution can be found for the case of a constant heat transfer coefficient. The ambient temperature variation alone decreases the fin efficiency less than 4%. The local heat transfer coefficient obtained from the numerical fluid flow simulations is strongly affected by the fin properties because the thermal boundary conditions for the fluid flow changes. On a poorly conducting fin surface the heat transfer coefficient in front of the fin base is much larger than on an isothermal fin because the heat flux is increasing in the flow direction. At low fin efficiencies this compensates for the decrease in fin efficiency due to ambient temperature variation.  相似文献   

20.
Data reduction for air-side performance of fin-and-tube heat exchangers   总被引:13,自引:0,他引:13  
The present study focuses on the data reduction method to obtain the air-side performance of fin-and-tube heat exchangers. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper recommends standard procedures for dry surface heat transfer in finned-tube heat exchangers having water on the tube-side. Inconsistencies addressed include the -NTU relationships, calculation of the tube-side heat transfer coefficient, calculation of fin efficiency, and whether entrance and exit loss should be included in the reduction of friction factors. Use of the recommended standardized methodology will provide more meaningful data for use in the development of correlations, or for performance comparison purposes.  相似文献   