首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
Even when DNA sequencing of purified DNA template failed under the optimal condition, it can be generally contributed to high GC content. GC-rich region of template causes a secondary structure to produce shorter readable sequence. To solve this problem, the sequencing reaction was modified by using dimethyl sulfoxide (DMSO). It was found that 5% (v/v) of DMSO in the reaction mixture recovers sequencing signal intensity with reduced frequency of ambiguous bases. When DMSO was added to sequencing reaction of DNA template with normal GC content, it did not show any adverse effect. Sequencing accuracy and unambiguous base frequency were significantly improved at concentration of 2% to 5% (v/v) DMSO in GC-rich DNA template. DMSO has been empirically introduced to enhance the efficiency of PCR in GC-rich templates. However, the underlying mechanism of improved cycle sequencing by DMSO is unknown. Thus, cycle sequencing reaction was remodified with other additives such as N-methyl imidazole, N-methyl2-pyrrolidone, N-methyl-2-pyridone and glycerol, possessing the similar chemical properties as DMSO. Most of methyl nitrogen ring-containing chemicals did not improve sequencing accuracy, whereas only glycerol mimicked the positive effect of DMSO by the same extent. In the present study, we suggest that the treatment of DMSO improve cycle sequencing by the alteration of structural conformation of GC-rich DNA template.  相似文献   

2.
Bhat S  McLaughlin JL  Emslie KR 《The Analyst》2011,136(4):724-732
Digital polymerase chain reaction (dPCR) has the potential to enable accurate quantification of target DNA copy number provided that all target DNA molecules are successfully amplified. Following duplex dPCR analysis from a linear DNA target sequence that contains single copies of two independent template sequences, we have observed that amplification of both templates in a single partition does not always occur. To investigate this finding, we heated the target DNA solution to 95 °C for increasing time intervals and then immediately chilled on ice prior to preparing the dPCR mix. We observed an exponential decline in estimated copy number (R(2)≥ 0.98) of the two template sequences when amplified from either a linearized plasmid or a 388 base pair (bp) amplicon containing the same two template sequences. The distribution of amplifiable templates and the final concentration (copies per μL) were both affected by heat treatment of the samples at 95 °C from 0 s to 30 min. The proportion of target sequences from which only one of the two templates was amplified in a single partition (either 1507 or hmg only) increased over time, while the proportion of target sequences where both templates were amplified (1507 and hmg) in each individual partition declined rapidly from 94% to 52% (plasmid) and 88% to 31% (388 bp amplicon) suggesting an increase in number of targets from which both templates no longer amplify. A 10 min incubation at 95 °C reduced the initial amplifiable template concentration of the plasmid and the 388 bp amplicon by 59% and 91%, respectively. To determine if a similar decrease in amplifiable target occurs during the default pre-activation step of typical PCR amplification protocol, we used mastermixes with a 20 s or 10 min hot-start. The choice of mastermix and consequent pre-activation time did not affect the estimated plasmid concentration. Therefore, we conclude that prolonged exposure of this DNA template to elevated temperatures could lead to significant bias in dPCR measurements. However, care must be taken when designing PCR and non-PCR based experiments by reducing exposure of the DNA template to sustained elevated temperatures in order to improve accuracy in copy number estimation and concentration determination.  相似文献   

3.
Aptamers are DNA oligonucleotides capable of binding different classes of targets with high affinity and selectivity. They are particularly attractive as affinity probes in multiplexed quantitative analysis of proteins. Aptamers are typically selected from large libraries of random DNA sequences in a general approach termed systematic evolution of ligands by exponential enrichment (SELEX). SELEX involves repetitive rounds of two processes: (i) partitioning of aptamers from non-aptamers by an affinity method and (ii) amplification of aptamers by the polymerase chain reaction (PCR). New partitioning methods, which are characterized by exceptionally high efficiency of partitioning, have been recently introduced. For the overall SELEX procedure to be efficient, the high efficiency of new partitioning methods has to be matched by high efficiency of PCR. Here we present the first detailed study of PCR amplification of random DNA libraries used in aptamer selection. With capillary electrophoresis as an analytical tool, we found fundamental differences between PCR amplification of homogeneous DNA templates and that of large libraries of random DNA sequences. Product formation for a homogeneous DNA template proceeds until primers are exhausted. For a random DNA library as a template, product accumulation stops when PCR primers are still in excess of the products. The products then rapidly convert to by-products and virtually disappear after only 5 additional cycles of PCR. The yield of the products decreases with the increasing length of DNA molecules in the library. We also proved that the initial number of DNA molecules in PCR mixture has no effect on the by-products formation. While the increase of the Taq DNA polymerase concentration in PCR mixture selectively increases the yield of PCR products. Our findings suggest that standard procedures of PCR amplification of homogeneous DNA samples cannot be transferred to PCR amplification of random DNA libraries: to ensure efficient SELEX, PCR has to be optimized for the amplification of random DNA libraries.  相似文献   

4.
To broaden the applicability of chemically modified DNAs in nano- and biotechnology, material science, sensor development, and molecular recognition, strategies are required for introducing a large variety of different modifications into the same nucleic acid sequence at once. Here, we investigate the scope and limits for obtaining functionalized dsDNA by primer extension and PCR, using a broad variety of chemically modified deoxynucleotide triphosphates (dNTPs), DNA polymerases, and templates. All natural nucleobases in each strand were substituted with up to four different base-modified analogues. We studied the sequence dependence of enzymatic amplification to yield high-density functionalized DNA (fDNA) from modified dNTPs, and of fDNA templates, and found that GC-rich sequences are amplified with decreased efficiency as compared to AT-rich ones. There is also a strong dependence on the polymerase used. While family A polymerases generally performed poorly on "demanding" templates containing consecutive stretches of a particular base, family B polymerases were better suited for this purpose, in particular Pwo and Vent (exo-) DNA polymerase. A systematic analysis of fDNAs modified at increasing densities by CD spectroscopy revealed that single modified bases do not alter the overall B-type DNA structure, regardless of their chemical nature. A density of three modified bases induces conformational changes in the double helix, reflected by an inversion of the CD spectra. Our study provides a basis for establishing a generally applicable toolbox of enzymes, templates, and monomers for generating high-density functionalized DNAs for a broad range of applications.  相似文献   

5.
Yaku H  Yukimasa T  Nakano S  Sugimoto N  Oka H 《Electrophoresis》2008,29(20):4130-4140
PCR experiments using DNA primers forming mismatch pairing with template lambda DNA at the 3' end were carried out in order to develop allele-specific primers capable of detecting SNP in genomes without generating pseudopositive amplification products, and thus avoiding the so-called pseudopositive problem. Detectable amounts of PCR products were obtained when primers forming a single or two mismatch pairings at the 3' end were used. In particular, 3' terminal A/C or T/C (primer/template) mismatches tended to allow PCR amplification to proceed, resulting in pseudopositive results in many cases. While less PCR product was observed for primers forming three terminal mismatch pairings, target DNA sequences were efficiently amplified by primers forming two mismatch pairings next to the terminal G/C base pairing. These results indicate that selecting a primer having a 3' terminal nucleotide that recognizes the SNP nucleotide and the next two nucleotides that form mismatch pairings with the template sequence can be used as an allele-specific primer that eliminates the pseudopositive problem. Trials with the human ABO genes demonstrated that this primer design is also useful for detecting a single base pair difference in gene sequences with a signal-to-noise ratio of at least 45.  相似文献   

6.
7.
Yue GH  Orban L 《Electrophoresis》2005,26(16):3081-3083
We have developed a very simple and inexpensive method for high-throughput DNA extraction from animal tissues. The procedure contains three steps (digestion, heating, and centrifugation) and it is compatible with the 96-well plate format commonly used in polymerase chain reaction (PCR) amplifications. The duration for processing a plate is about 1.5 h; therefore, one researcher can isolate DNA from up to 1000 samples during a single workday. A small piece of tissue (ca. 10-20 mg) yields enough template for at least 50-70 PCR amplifications, as demonstrated by using the processed samples as templates successfully for long distance PCR, multiplex PCR, and randomly amplified polymorphic DNA (RAPD) assay. The application of our method is expected to facilitate studies that require high-throughput DNA isolation for PCR amplification, such as genotyping by microsatellites for mapping and genetic diversity studies, as well as mutant screening in zebrafish.  相似文献   

8.
Flow-through chip thermocyclers can be used in miniaturized rapid polymerase chain reaction (PCR) despite their high surface to volume ratio of samples. We demonstrated that a thermocycler made of silicon and glass chips and containing thin film transducers for heating and temperature control can be adapted to the amplification of various DNA templates of different sources and properties. Therefore, the concept of serial flow in a liquid/liquid two-phase system was combined with a surface management of inner side walls of the microchannel and an adaptation of PCR mixture composition. In addition, the process temperatures and the flow rates were optimized. Thus, a synthetic template originating from investigations on nucleic acid evolution with 106 base pairs [cooperative amplification of templates by cross hybridization (CATCH)], a house keeping gene with 379 base pairs [glutaraldehyde 3-phosphate dehydrogenase (GAPDH)] and a zinc finger protein relevant in human pathogenesis with 700 base pairs [Myc-interacting zinc finger protein-1, knock-out (Miz1-KO)] were amplified successfully. In all three cases the selectivity of priming and amplification could be shown by gel electrophoresis. The typical amplification time was 1 min per temperature cycle. So, the typical residence time of a sample volume inside the 25 cycle device amounts to less then half an hour. The energy consumption of the PCR chip for a 35 min PCR process amounts to less than 0.012 kW h.  相似文献   

9.
Rolling circle amplification (RCA) has been widely used as an isothermal DNA amplification technique for diagnostic and bioanalytical applications. Because RCA involves repeated copying of the same circular DNA template by a DNA polymerase thousands of times, we hypothesized there exist DNA sequences that can function as optimal templates and produce more DNA amplicons within an allocated time. Herein we describe an in vitro selection effort conducted to search from a random sequence DNA pool for such templates for phi29 DNA polymerase, a frequently used polymerase for RCA. Diverse DNA molecules were isolated and they were characterized by richness in adenosine (A) and cytidine (C) nucleotides. The top ranked sequences exhibit superior RCA efficiency and the use of these templates for RCA results in significantly improved detection sensitivity. AC‐rich sequences are expected to find useful applications for setting up effective RCA assays for biological sensing.  相似文献   

10.
11.
12.
High sensitivity PCR assay in plastic micro reactors   总被引:6,自引:0,他引:6  
Small volume operation and rapid thermal cycling have been subjects of numerous reports in micro reactor chip development. Sensitivity aspects of the micro PCR reactor have not been studied in detail, however, despite the fact that detection of rare targets or trace genomic material from clinical and/or environmental samples has been a great challenge for microfluidic devices. In this study, a serpentine shaped thin (0.75 mm) polycarbonate plastic PCR micro reactor was designed, constructed, and tested for not only its rapid operation and efficiency, but also its detection sensitivity and specificity, in amplification of Escherichia coli (E. coli) K12-specific gene fragment. At a template concentration as low as 10 E. coli cells (equivalent to 50 fg genomic DNA), a K12-specific gene product (221 bp) was adequately amplified with a total of 30 cycles in 30 min. Sensitivity of the PCR micro reactor was demonstrated with its ability to amplify K12-specific gene from 10 cells in the presence of 2% blood. Specificity of the polycarbonate PCR micro reactor was also proven through multiplex PCR and/or amplification of different pathogen-specific genes. This is, to our knowledge, the first systematic study of assay sensitivity and specificity performed in plastic, disposable micro PCR devices.  相似文献   

13.
A highly sensitive telomerase detection method that combines telomeric repeat amplification protocol (TRAP) and magnetic beads based electrochemiluminescence (ECL) assay has been developed. Briefly, telomerase recognizes biotinylated telomerase synthesis primer (B-TS) and synthesizes extension products, which then serve as the templates for PCR amplification using B-TS as the forward primer and tris-(2′2′-bipyridyl) ruthenium (TBR) labeled ACX (TBR-ACX) as the reversed primer. The amplified product is captured on streptavidin-coated paramagnetic beads and detected by ECL. Telomerase positive HeLa cells were used to validate the feasibility of the method. The experimental results showed down to 10 cancer cells can be detected easily. The method is a useful tool for telomerase activity analysis due to its sensitivity, rapidity, safety, high throughput, and low cost. It can be used for screening a large amount of clinical samples.  相似文献   

14.
A simple and highly sensitive electrochemical biosensor for microRNA (miRNA) detection was successfully developed by integrating a target‐assisted isothermal exponential amplification reaction (EXPAR) with enzyme‐amplified electrochemical readout. The binding of target miRNA with the immobilized linear DNA template generated a part duplex and triggered primer extension reaction to form a double‐stranded DNA. Then one of the DNA strands was cleaved by nicking endonuclease and extended again. The short fragments with the same sequence as the target miRNA except for the replacement of uridines and ribonucleotides with thymines and deoxyribonucleotides could be displaced and released. Hybridization of these released DNA fragments with other amplification templates and their extension on the templates led to target exponential amplification. Integrating with enzyme‐amplified electrochemical readout, the electrochemical signal decreases with the increasing target microRNA concentration. The method could detect miRNA down to 98.9 fM with a linear range from 100 fM to 10 nM. The fabrication and binding processes were characterized with cyclic voltammetry and electrochemical impedance spectroscopy. The specificity of the method allowed single‐nucleotide difference between miRNA family members to be discriminated. The established biosensor displayed excellent analytical performance toward miRNA detection and might present a powerful and convenient tool for biomedical research and clinic diagnostic application.  相似文献   

15.
We report the combination of "click chemistry" with PCR by using alkyne-modified triphosphates for efficient and homogeneous labeling of DNA. A series of modified PCR products of different lengths (300, 900, and 2000 base pairs) were prepared by using a variety of alkyne- and azide-containing triphosphates and different polymerases. After intensive screening of real-time PCR methods, protocols were developed that allow the amplification of genes by using these modified triphosphates with similar efficiency to that of standard PCR. The click reaction on the highly modified PCR fragments provided conversion rates above 90 % and resulted in the functionalization of hundreds of alkynes on large DNA fragments with superb selectivity and efficiency.  相似文献   

16.
A bicyclic imidazolium ionic liquid (4d), [b-4C-im][Br], was found to be highly effective not only for promoting PCR of GC-rich DNA by minimizing non-specific amplification, but also for facilitating PCR of normal-GC DNA under mild conditions.  相似文献   

17.
18.
With a novel and universal strategy for the cloning of multiple DNA fragments, a complex synthetic vector (pVEC100), harboring the target DNA fragments in conventional 100‐bp DNA ladder, was constructed for efficient and large‐scale production of 100‐bp DNA marker through bacteria fermentation, plasmid extraction and restrictive digestion. Since the restrictive digestion of complex vectors yields insufficient small DNA fragments, an innovative PCR model was developed as an alternative. The PCR model comprised a specially designed template vector and a unit amplification model for producing groups of small DNA fragments. The unit amplification model improved the efficiency of the PCR protocol and made it more economical and easier for small DNA fragment amplification. The approach presented in this paper – a unit cloning model for constructing complex synthetic vectors combined with the modular design of unit amplification by PCR – is a powerful method for preparing small DNA fragments of DNA molecular weight standards.  相似文献   

19.
一种可绝对定量核酸的数字PCR微流控芯片   总被引:2,自引:0,他引:2  
构建了一种新型的可进行核酸单分子扩增和核酸绝对定量的数字聚合酶链式反应(数字PCR)微流控芯片. 应用多层软光刻技术, 以聚二甲基硅氧烷(PDMS)作为芯片材料, 盖玻片作为基底制作了具有3层结构以及微阀控制功能的微流控芯片. 芯片的大小与载玻片相当, 可同时检测4个样品, 每个样品通入芯片后平均分配到640个反应小室, 每个小室的体积为6 nL. 以从肺癌细胞A549中提取的18sRNA为样品检测了该芯片的可行性. 将样品稀释数倍后通入芯片, 核酸分子随机分布在640个小室中并扩增. 核酸分子在芯片中的分布符合泊松分布原理, 当样品中待测核酸分子平均拷贝数低于0.5个/小室时, 则每个反应小室包含0个或1个分子. 经过PCR扩增后, 有模板分子的小室检测结果为阳性反应, 而无模板分子的小室为阴性反应, 最后通过计数阳性反应室的个数, 可绝对定量原始待测样品中的目标DNA分子拷贝数. 实验结果表明, 该数字 PCR芯片可实现DNA单分子反应和核酸绝对定量, 具有成本低、 灵敏度高、 节省时间和试剂以及操作简单等优点, 为数字PCR方法在普通实验室的应用提供了一种新途径, 可用于癌症及感染性疾病的早期诊断、 单细胞分析、 产前诊断以及各种细菌病毒的核酸检验等研究.  相似文献   

20.
Whole genome amplification (wga) of DNA is being widely implemented in many laboratories to extend the life of samples only available in limited quantities for genetic analysis. We determined the reliability of wgaDNA genotypes in three sets of replicates from the same individuals: (i) 23 pairs of genomic DNA (gDNA), (ii) 43 pairs gDNA versus wgaDNA, and (iii) 29 pairs of independently amplified wgaDNA. Amplification was performed using multiple displacement amplification (MDA). Genotyping was successful for both DNA types for 1268 out of 1534 SNPs from 164 cardiovascular candidate genes assayed in a single Illumina panel. Amplified DNA failed for 77 SNPs (6%) that were genotyped successfully with genomic material. Percent of successful SNP calls, and concordance between pairs and kappa statistics (kappa) were determined. A total of 54 110 genotypes from gDNA-wgaDNA pairs were available for concordance analysis. Mean kappa for gDNA-wgaDNA pairs was 0.99. Concordance between gDNA-wgaDNA pairs was higher than amongst wgaDNA pairs (mean kappa for the 29 independently amplified pairs of wgaDNA was 0.95; interquartile range: 0.93-1.00). A statistical analysis of those SNPs which failed to genotype from amplified DNA only revealed that those loci were more likely to be closer to the telomeres and in locally GC-rich sequences. In summary, the MDA method produces wgaDNA samples that can be genotyped using high-throughput technology with a very high reproducibility to the original DNA but with slightly lower call rates. DNA amplification methodologies provide a useful solution for current and future large-scale genetic analyses especially with limited quantities of samples and DNA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号