共查询到20条相似文献,搜索用时 15 毫秒
1.
An amperometric detector with a gold nanoparticle modified carbon paste electrode (GNMCPE) was applied applied to flow injection analysis for the determination of acetaminophen. An obvious shift of the peak potential and increase of the current peak were observed for the GNMCPE in comparison to that of the bare carbon paste electrode. The experimental conditions, such as species of buffer, pH, flow rate, detection volume, injection volume, and injection time were investigated. Under the optimized conditions, the calibration curve was obtained over the concentration range of 0.1–80 mg L?1 of acetaminophen with a linear correlation coefficient of 0.9994. The detection limit (3σ) was estimated to be 0.05 mg L?1 (n?=?7). The recoveries of acetaminophen were between 98.40% and 104.1%, and the relative standard deviation varied between 1.66% and 2.74% for the different samples. This method was applied to analyze six types of tablets obtained from a local drugstore. The contents of acetaminophen were found to be 0.498, 0.323, 0.249, 0.324, 0.319 and 0.323 g of each tablet, respectively. These results are consistent with the values obtained by high performance liquid chromatography. 相似文献
2.
The anodic voltammetric behavior of methotrexate was studied at glassy carbon electrode in acetate buffer (pH = 3.6) solution using cyclic, square-wave voltammetric and chronocoulometric techniques. The oxidation of methotrexate is an irreversible diffusion-controlled process. The oxidation mechanism was proposed and discussed in this work. The dependence of the current on pH, the concentration and nature of buffer, and instrumental parameters were investigated to optimize the experimental conditions for the determination of methotrexate. It was found that in the range of 8.0 × 10−7–2.0 × 10−5 mol/L, the currents measured by square-wave voltammetry presented a good linear property as a function of the concentrations of methotrexate. In addition, validation parameters, such as reproducibility, sensitivity and recovery were evaluated as well. The proposed method was also successfully applied for the determination of methotrexate in diluted human urine with good satisfactory. 相似文献
3.
An electrochemically prepared thin film of cobalt pentacyanonitrosylferrate (GC/CoPCNF) was used as a surface modifier for glassy carbon electrodes. The oxidation of ascorbic acid on a glassy carbon electrode modified with GC/CoPCNF as a working electrode was studied using cyclic voltammetry, rotating disk electrode (RDE) voltammetry and chronoamperometry in a 0.25 M KNO3 + 0.25 M phosphate buffer (pH 7) solution. The glassy carbon modified with CoPCNF showed good electrocatalytic activity toward ascorbic acid oxidation. The kinetics of the catalytic reaction was investigated, and the average value of the rate constant (k) for the catalytic reaction and the diffusion coefficient (D) were evaluated by different approaches for ascorbic acid, and were found to be 3.3 +/- 0.3 x 10(2) M(-1) s(-1) and 3.2 +/- 0.3 x 10(-6) cm2 s(-1), respectively. 相似文献
4.
Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes 总被引:2,自引:0,他引:2
A multi-wall carbon nanotube (MWNT) modified glassy carbon electrode (GCE) was described for the simultaneous determination of trace levels of cadmium and lead by anodic stripping voltammetry (ASV). In pH 4.5 NaAc-HAc buffer containing 0.02 mol/l KI, Cd2+ and Pb2+ first adsorb onto the surface of a MWNT film coated GCE and then reduce at −1.20 V. During the positive potential sweep, reduced cadmium and lead were oxidized, and two well-defined stripping peaks appeared at −0.88 and −0.62 V. Compared with a bare GCE, a MWNT film coated GCE greatly improves the sensitivity of determining cadmium and lead. Low concentration of I− significantly enhances the stripping peak currents since it induces Cd2+ and Pb2+ to adsorb at the electrode surface. The striping peak currents change linearly with the concentration of Cd2+ from 2.5×10−8 to 1×10−5 mol/l and with that of Pb2+ from 2×10−8 to 1×10−5 mol/l. The lowest detectable concentrations of Cd2+ and Pb2+ are estimated to be 6×10−9 and 4×10−9 mol/l, respectively. The high sensitivity, selectivity, and stability of this MWNT film coated electrode demonstrated its practical application for a simple, rapid and economical determination of trace levels of Cd2+ and Pb2+ in water samples. 相似文献
5.
6.
The voltammetric method for simultaneous determination of some disinfectants at glassy carbon electrode modified with multiwalled carbon nanotubes is presented. The examined compounds are: 2-phenylphenol, 4-chloro-3-methylphenol, triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol and 2-mercaptobenzothiazole. The measurements has been performed using cyclic voltammetry and differential pulse voltammetry in Britton-Robinson buffers as supporting electrolytes. The modification of electrode surface with multiwalled carbon nanotubes enhances the peak current. It is possible to measure mixtures of two compounds (2-phenylphenol and 2-mercaptobenzothiazole, 4-chloro-3-methylphenol and 2-mercaptobenzothiazole, triclosan and 2-mercaptobenzothiazole) in the solution of pH 9.9, which provides the best separation of oxidation peaks. 相似文献
7.
8.
A new, simple and low cost voltammetric method for the determination of cefpirome in pharmaceutical preparations has been developed using multiwalled carbon nanotube modified glassy carbon electrode (MWCNT), which showed stable response with enhanced selectivity and sensitivity over the bare glassy carbon electrode. A multiwalled carbon nanotube (MWCNT) modified glassy carbon electrode (GCE) is used for the simultaneous determination of cefpirome by differential pulse voltammetry and square wave voltammetry. Results indicated that cathodic peak of cefpirome is greatly improved at MWCNT modified GC electrode as compared with the bare GC electrode showing excellent electrocatalytic activity towards cefpirome reduction. Linear calibration curves are obtained over the concentration range 100-600 μg mL(-1) in Britton Robinson buffer at pH 4.51 with limit of detection (LOD) and limit of quantification (LOQ) are 0.647 μg mL(-1) and 2.159 μg mL(-1) using SWV and 5.540 μg mL(-1) and 18.489 μg mL(-1) using DPV, respectively. The described method is rapid and can be successfully applied for the determination of cefpirome in bulk form and pharmaceutical formulations. 相似文献
9.
通过在玻碳电极表面电化学还原氧化石墨烯的方法制备了石墨烯修饰电极,研究了美洛昔康在该修饰电极上的电化学行为。优化了包括支持电解质及pH、修饰剂用量、富集电位及时间等测定条件,据此建立了一种直接测定美洛昔康的电化学分析方法。在0.1 mol/L Britton-Robinson缓冲液(pH 3.0)中,氧化峰电流与美洛昔康浓度在1.0×10-6~8.0×10-5mol/L范围内呈现良好的线性关系,检出限为3.0×10-7mol/L(S/N=3)。方法可用于片剂和尿样中美洛昔康的测定。 相似文献
10.
采用直接电化学沉积法制备出纳米金修饰玻碳电极,研究了其对亚硝酸根的电催化氧化作用。结果表明,亚硝酸根在该修饰电极上于0.8 V处出现了一个良好的氧化峰。在最优实验条件下,亚硝酸根的峰电流与其浓度在2×10-6~2×10-3mol/L范围内呈一定的线性关系,检出限为6.0×10-7(S/N=3),提出了用循环伏安法测定亚硝酸根的方法。纳米金修饰电极用于东莞自来水水样中亚硝酸根的测定,回收率在98.1%~101.4%之间。对比本方法,用分光光度法对东莞自来水样中亚硝酸根进行了测定,结果满意。 相似文献
11.
12.
13.
Abdollah Salimi Zahra Enferadi Abdollah Noorbakhash Kayomars Rashidi 《Journal of Solid State Electrochemistry》2012,16(4):1369-1375
Glassy carbon electrode modified with electrodeposited nickel oxide nanoparticles (NiOxNPs) was used as electrocatalyst for
oxidation of omeprazole and pentoperazole in alkaline solution. The modified electrode exhibited efficient electrocatalytic
activity for the oxidation of omeprazole and pentoperazole with relatively high sensitivity, excellent stability, and long
lifetime. Hydrodynamic amperometric method is used for determination of selected analytes. Under optimized condition, the
linear concentration range, detection limit, and sensitivity of modified electrode toward omeprazole detection are 4.5–120 μM,
0.4 μM (at signal to noise 3), and 40.1 nA μM−1 cm−2, respectively. For pantoperazole, hydrodynamic amperometric determination yielded calibration curve with linear range of
2.5–180 μM, detection limit of 0.2 μM, and sensitivity of 39.2 nA μM−1 cm−2, respectively. The proposed method was successfully applied to pentoperazole and omeprazole determination in drug samples. 相似文献
14.
The electrochemical oxidative behavior of terbutaline at the glassy carbon electrode was studied in a series of the Britton-Robinson buffer of pH 2--11. Cyclic and square-wave voltammograms of terbutaline at the pH values =9 exhibited a single irreversible anodic peak. A fully validated, simple, sensitive and precise square-wave adsorptive anodic stripping voltammetric procedure was described for the determination of terbutaline in bulk form, tablets and human serum. For 5x10(-8) M bulk terbutaline a mean recovery of 98.78+/-0.94% (n=5) was achieved following its preconcentration by adsorptive accumulation onto the glassy carbon electrode at a +0.15 V (vs. Ag/AgCl/KCl(s)) for 180 s. Limit of detection of 6x10(-9) M and limit of quantitation of 2x10(-8) M terbutaline were achieved in the bulk form or its formulations (Bricanyl tablets). The described square-wave adsorption anodic stripping voltammetric procedure was successfully applied for the determination of terbutaline in human serum following medium exchange. Limit of detection of 1.41x10(-8) M (3.173 ng ml(-1)) and limit of quantitation of 4.70x10(-8) M (10.575 ng ml(-1)) were achieved in human serum with a mean recovery of 98.11+/-1.13%. 相似文献
15.
Metallic nanoparticles of rhodium were prepared by using the newly synthesized N,N-bis-succinamide-based dendrimer as stabilizers. The Rh nanoparticles were spherical shaped with a particle size of ∼2 nm. The dendrimer Rh-encapsulated nanoparticles (Rh-DENs) were immobilized on glassy carbon electrode (GCE) and their electrocatalytic activity towards hydrogen peroxide reduction was investigated using cyclic voltammetry and chronoamperometry. The Rh-DENs modified GCE showed excellent electrocatalytic activity for hydrogen peroxide reduction reactions. The steady-state cathodic current response of the modified electrode at −0.3 V (vs SCE) in phosphate buffer (pH 7.0) showed a linear response to hydrogen peroxide concentration ranging from 8 to 30 μM with a detection limit and sensitivity of 5 μM and 0.03103 × 10−6 A μM−1, respectively. 相似文献
16.
Débora A. R. Moreira Dilton M. Pimentel Mariane O. B. Arrieiro Sandro L. Barbosa Rodrigo A. B. da Silva Wallans T. P. dos Santos 《Electroanalysis》2023,35(5):e202200213
This work presents, for the first time, the voltammetric behavior of clonidine (CLO) drug and its determination, using an unmodified glassy carbon electrode (GCE). CLO exhibited only an irreversible oxidation process on the GCE, with peak potential at +0.85 V in pH 12 (vs Ag/AgCl). CLO oxidation process is pH-dependent and the electrochemical mechanisms on the GCE were proposed in acidic and basic medium. The determination of CLO was optimized in 0.1 mol L−1 phosphate buffer solution at pH 12.0 using differential pulse voltammetry (DPV), which provides a good linear range (0.65 to 106.00 μmol L−1) and low theoretical limit of detection (0.14 μmol L−1) for the quality control of this drug in pharmaceutical samples. In addition, stable responses of CLO at the GCE were obtained in the same day (RSD = 3.4 %; n = 5) and different days (RSD = 2.0 %; n = 3). Moreover, the determination of CLO in a pharmaceutical formulation using the proposed GCE-DPV method presented good accuracy, since the recovery was close to 100 % and the dosing result was in agreement with an official method (HPLC-UV). The proposed method demonstrates a good analytical performance for CLO determination in pharmaceutical samples, providing a faster, simpler and lower-cost alternative for quality control of CLO than other reported methods. 相似文献
17.
18.
Rajesh N. Hegde Ragunatharaddi R. Hosamani Sharanappa T. Nandibewoor 《Colloids and surfaces. B, Biointerfaces》2009,72(2):259-265
We discovered a novel method to prepare a protein-based hydrogel, that is, a “Three-Dimensional Nanostructured Protein Hydrogel (3D NPH)”, which is composed of protein–polymer hybrid nanoparticles. In this study, we propose a novel protein microarray whose 3D NPH spots were prepared by dispensing a small volume of the solution of protein–polymer mixture on a substrate. The dispensed solution had a short time for cross-linking before its drying-up and the resulting 3D NPH had loosely cross-linked, thin spongy structure. Therefore, the reaction ratio between ligands and analytes was drastically improved in this system compared with the large volume system for Surface Plasmon Resonance (SPR) protein microarray. 相似文献
19.
20.
Determination of sulfonamides in milk samples by HPLC with amperometric detection using a glassy carbon electrode modified with multiwalled carbon nanotubes 下载免费PDF全文
A sensitive and accurate method for determining five sulfonamides based on HPLC with amperometric detection and using a glassy carbon electrode modified with multiwalled carbon nanotubes is proposed. Optimal conditions for the quantitative separation of selected sulfonamides were studied, and glassy carbon electrodes with and without modification with carbon nanotubes were systematically investigated as electrodic materials. Statistical analysis of the obtained results demonstrated that these modified electrodes achieved considerably better stability and sensitivity than the conventional unmodified ones. Detection limits were in the 1.2–6.0 ng/mL range. The usefulness of the method was demonstrated by the analysis of milk samples, taking into account the European legislation on residues in food products, following both a screening method to classify the samples and a confirmation method to provide more detailed information in the case of positive samples. 相似文献