首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Microchip electrophoresis (MCE) has been advanced remarkably by the applications of several separation modes and the integration with several chemical operations on a single planer substrate. MCE shows superior analytical performance, e.g., high-speed analysis, high resolution, low consumption of reagents, and so on, whereas low-concentration sensitivity is still one of the major problems. To overcome this drawback, various online sample preconcentration techniques have been developed in MCE over the past 15 years, which have successfully enhanced the detection sensitivity in MCE. This review highlights recent developments in online sample preconcentration in MCE categorized on the basis of "dynamic" and "static" methods. The dynamic techniques including field amplified stacking, ITP, sweeping, and focusing have been easily applied to MCE, which provide effective enrichments of various analytes. The static techniques such as SPE and filtration have also been combined with MCE. In the static techniques, extremely high preconcentration efficiency can be obtained, compared to the dynamic methods. This review provides comprehensive tables listing the applications and sensitivity enhancement factors of these preconcentration techniques employed in MCE.  相似文献   

2.
This review highlights the methodological and instrumental developments in microchip micellar EKC (MCMEKC) from 1995. The combination of higher separation efficiencies in micellar EKC (MEKC) with high-speed separation in microchip electrophoresis (MCE) should provide high-throughput and high-performance analytical systems. The chip-based separation technique has received considerable attention due to its integration ability without any connector. This advantage allows the development of a multidimensional separation system. Several types of 2-D separation microchips are described in the review. Since complicated channel configurations can easily be fabricated on planar substrates, various sample manipulations can be carried out prior to MCMEKC separations. For example, mixing for on-chip reactions, on-line sample preconcentration, on-chip assay, etc., have been integrated on MEKC microchips. The application of on-line sample preconcentration to MCMEKC can provide not only sensitivity enhancement but also the elucidation of the preconcentration mechanism due to the visualization ability of MCE. The characteristics of these sample manipulations on MEKC microchips are presented in this review. The scope of applications in MCMEKC covers mainly biogenic compounds such as amino acids, peptides, proteins, biogenic amines, DNA, and oestrogens. This review provides a comprehensive table listing the applications in MCMEKC in relation to detection methods.  相似文献   

3.
《Electrophoresis》2017,38(16):2075-2080
A combination of two online sample concentration techniques, large‐volume sample stacking with an electroosmotic flow (EOF) pump (LVSEP) and field‐amplified sample injection (FASI), was investigated in microchip electrophoresis (MCE) to achieve highly sensitive analysis. By applying reversed‐polarity voltages on a cross‐channel microchip, anionic analytes injected throughout a microchannel were first concentrated on the basis of LVSEP, followed by the electrokinetic stacking injection of the analytes from a sample reservoir by the FASI mechanism. As well as the voltage application, a pressure was also applied to the sample reservoir in LVSEP‐FASI. The applied pressure generated a counter‐flow against the EOF to reduce the migration velocity of the stacked analytes, especially around the cross section of the microchannel, which facilitated the FASI concentration. At the hydrodynamic pressure of 15 Pa, 4520‐fold sensitivity increase was obtained in the LVSEP‐FASI analysis of a standard dye, which was 33‐times higher than that obtained with a normal LVSEP. Furthermore, the use of the sharper channel was effective for enhancing the sensitivity, e.g., 29 100‐fold sensitivity increase was achieved with the 75‐μm wide channel. The developed method was applied to the chiral analysis of amino acids in MCE, resulting in the sensitivity enhancement factor of 2920 for the separated d ‐leucine.  相似文献   

4.
Lin CH  Kaneta T 《Electrophoresis》2004,25(23-24):4058-4073
Methods with a high sensitivity and high separation efficiency are goals in analytical separation techniques. On-line sample concentration techniques in capillary electrophoresis (CE) separations have rapidly grown in popularity over the past few years because they achieve this goal. This review describes the methodology and theory associated with a number of different techniques, including electrokinetic and chromatographic methods. For small molecules, several on-line concentration methods based on velocity gradient techniques are described, in which the electrophoretic velocities of the analyte molecules are manipulated by field amplification, sweeping, and isotachophoretic migration, resulting in the on-line concentration of the analyte zones. In addition, the on-line concentration methods for macromolecules are described, since the techniques used for macromolecules (DNAs and proteins), are different from those for small molecules, with respect to either mechanism or methodology. Recent studies relating to this topic are also discussed, including electrophoretic and chromatographic techniques on capillary or microchip.  相似文献   

5.
Transient trapping (tr-trapping) was developed as one of the on-line sample preconcentration techniques to improve a low concentration-sensitivity in microchip electrophoresis (MCE), providing highly effective preconcentration and separation based on the trap-and-release mechanism. However, a poor performance to hydrophilic analytes limited the applicability of tr-trapping. To overcome this drawback, tr-trapping was combined with a sample labeling using a hydrophobic reagent in CE. Three commercially available fluorescent dyes, fluorescein isothiocyanate, succinimidyl esters of Alexa Fluor 488 and BODIPY FL-X, were tested as derivatization reagents to increase the hydrophobicity of amino acids (AAs) that were undetectable due to no fluorescence/UV-absorbance. As a result, it was confirmed that BODIPY labeling allowed various AAs to be analyzed in tr-trapping-micellar electrokinetic chromatography (tr-trapping-MEKC) by the increase in the hydrophobicity. In tr-trapping-MEKC, both the improvement of the resolution and 106-125-fold enhancements of the detectability of labeled AAs were achieved relative to the conventional capillary zone electrophoresis. The limit of detection of labeled phenylalanine was improved from 800 to 5 pM by applying tr-trapping-MEKC. In tr-trapping-microchip MEKC, furthermore, an 80-160-fold enhancement of the peak intensity and a baseline separation was also achieved within 30 s. These results clearly demonstrate that the tr-trapping technique with hydrophobic labeling will make CE/MCE more sensitive for various analytes.  相似文献   

6.
基于微芯片电泳的脱氧核糖核酸片段的浓缩和分离   总被引:1,自引:0,他引:1  
徐中其  廣川健 《色谱》2009,27(1):102-106
采用超负荷电动供给(electrokinetic supercharging, EKS)预浓缩技术,在微芯片电泳(MCE)上对脱氧核糖核酸(DNA)片段进行浓缩和分离。EKS是集合样品电动进样(EKI)和过渡等速电泳(tITP)的一种在线浓缩方法。研究表明:采用该方法后,在40.5 mm长的单通道芯片上能够实现对低浓度样品的大量进样、浓缩和基线分离。在普通的紫外检测条件(检测波长为260 nm)下,对DNA片段的平均检出限(S/N=3)约为0.07 mg/L,仅为十字芯片上的微芯片电泳检出限的1/40。本文还对浓缩过程中的一些关键因素和定性分析进行了探讨。  相似文献   

7.
On-line preconcentration is one of the aspects of analytical method development using capillary electrophoretic techniques. The choice of the sample matrix alone can significantly alter both method sensitivity and separation efficiency. The recent trend to detect samples in narrower separation vessels also necessitates the need to improve detection sensitivity. The desire to detect very low levels of analytes using limited amounts of sample from biological specimens and the high separation efficiency obtainable using very large injections compared to classical small size injections also adds to this list. Indeed, one of the rich areas of research in the capillary electrophoresis field is on on-line sample preconcentration. More than 400 published research articles gathered from the http://www.webofscience.com from the year 2000 described a form of on-line preconcentration in capillary electrophoresis. This review provides a comprehensive table listing the applications of on-line preconcentration in capillary electrophoresis.  相似文献   

8.
Various flow sample handling approaches coupled to capillary electrophoresis (CE) are reviewed, covering the research in this field in the 12 years since the milestone year of 1997, when practical interfaces to on-line couple flow injection (FI) and capillary electrophoresis were first developed independently by two research groups. Some previous attempts are also presented. Since 1997 a plethora of ingenious coupled systems have been developed. Although several reviews are available on various aspects of the topic, we have opted for a comprehensive overview of all FI-CE systems, as well as related and similar systems. This coupling has thus also led to the development of systems based on hybrids between the classical and microchip approaches. Truly microchip FI-CE systems are also included in this review.The developed systems have been used for various sample treatments, including on-line membrane-assisted sample treatment, column-based preconcentration, on-line derivatization and monitoring, to name just a few. The utility of coupling flow sampling to CE has been demonstrated in various practical applications that are discussed in detail. The current state-of-the-art and foreseeable future developments are also discussed.  相似文献   

9.
Sweeping is a powerful on-line sample preconcentration technique that improves the concentration sensitivity of capillary electrophoresis (CE). This approach is designed to focus the analyte into narrow bands within the capillary, thereby increasing the sample volume that can be injected, without any loss of CE efficiency. It utilizes the interactions between an additive [i.e., a pseudostationary phase (PS) or complexing agent] in the separation buffer and the sample in a matrix that is devoid of the additive used. The accumulation occurs due to chromatographic partitioning, complexation or any interaction between analytes and the additive through electrophoresis. The extent of the preconcentration is dependent on the strength of interaction involved. Both charged and neutral analytes can be preconcentrated. Remarkable improvements—up to several thousandfold—in detection sensitivity have been achieved. This suggests that sweeping is a superior and general approach to on-line sample preconcentration in CE. The focusing mechanism of sweeping under different experimental conditions and its combination with other on-line preconcentration techniques are discussed in this review. The recently introduced techniques of transient trapping (tr-trapping) and analyte focusing by micelle collapse (AFMC) as well as other novel approaches to on-line sample preconcentration are also described.
Joselito P. QuirinoEmail:
  相似文献   

10.
刘玉兰  陈雅莉  肖小华  夏凌  李攻科 《色谱》2020,38(10):1197-1205
样品前处理能将待测物从复杂基质中预先分离富集出来,以提高分析方法的灵敏度、选择性和准确性,是复杂样品分析的关键步骤。样品前处理是一个非自发的、从无序到有序的熵减过程,不仅费时费力,还极易引起误差。向体系输入能量和降低体系熵值可以增强分离富集效果,加快样品制备过程。将电场引入在线样品前处理,既能向体系做功,又能驱动样品定向迁移,使前处理的熵减过程快速顺利进行,是快速样品制备的有效途径。基于电驱动的在线分离富集技术综合了多种加速策略:(1)以电场形式向体系输入能量,加速传质和传热过程;(2)采用电渗流、电泳等电驱动定向流实现样品在分离、富集、检测各步骤之间的定向迁移,保证样品前处理与检测顺利进行;(3)利用在线联用技术集成样品前处理与分析检测各步骤,从而提高自动化程度,减少人为误差;(4)通过微型化装置或微萃取方法提高样品制备效率,缩短样品制备时间。该文总结了近10年与基于电驱动的在线快速分离富集技术相关的90多篇文献,综述了该技术领域的研究进展,探讨了电驱动毛细管在线快速分离富集技术、电驱动芯片在线快速分离富集技术和电驱动膜萃取在线分离富集技术各自的优势和潜力,并展望了该类技术的发展与应用趋势。  相似文献   

11.
Fundamental understanding of the impact of reservoir potentials on the analyte behavior on the microfluidic chips is an important issue in microchip electrophoresis (MCE) for suitable injection and separation of analytes, since the applied potentials may significantly affect the shape of sample plug, sample leakage from the injection channel to the separation channel, injected sample amount, and separation efficiency. This study addressed this issue for the case of a conventional cross-geometry microchip with four reservoirs using computer simulations, the results of which were verified by the analysis of DNA fragments. For the microchip with a definite structure and migration distance, the injected sample amount was shown to be the vital parameter for improving the limit of detection and resolution. During injection, the shape of the sample plug could be adjusted by varying the reservoir potentials. It was demonstrated that a "magnified injection" (applying high voltage on the three reservoirs to the sample reservoir) is useful to enhance the detection sensitivity depending on the analyte composition, although such injection was previously avoided because of introducing too large amounts of the analyte in comparison with two established modes, floating and pinched injection. Optimal magnified injection was proved to improve the sensitivity for about 4 times over that of pinched injection for the analysis of DNA step ladders using microchip gel electrophoresis (MCGE). Sample leakage of DNA fragments could be suppressed by applying a high positive voltage on injection channel during separation, but the voltage degraded the injected amount and resolution.  相似文献   

12.
Complementary on-line preconcentration strategies are needed when analyzing different classes of solutes in real samples by capillary electrophoresis (CE) with UV detection. The performance of three different on-line preconcentration (focusing) techniques under alkaline conditions was examined in terms of their selectivity and sensitivity enhancement for a group of steroids, including classes of androgens, corticosteroids and estrogens. Electrokinetic focusing of large sample injection plugs (up to 28% of effective capillary length or 22.1 cm) directly on-capillary can be tuned for specific classes of steroids based on changes in their mobility (velocity) using a multi-section electrolyte system in CE. A dynamic pH junction was applied for the selective resolution and focusing of weakly acidic estrogens using borate, pH 11.0 and pH 8.0 in the background electrolyte and the sample, respectively. Sweeping, using an anionic bile acid surfactant and neutral gamma-cyclodextrin (gamma-CD) under alkaline conditions (pH 8), resulted in focusing and separation of the moderately hydrophobic (non-ionic) classes of steroids, such as androgen and corticosteroids. Optimal focusing and resolution of all test steroids under a single buffer condition was realized by a dynamic pH junction-sweeping format using borate, pH 11.0 and bile acid surfactant with gamma-CD in the BGE, whereas the sample is devoid of surfactant at pH 8.0. The design of selective on-line focusing strategies in CE is highlighted by the analysis of microgram amounts of ethynyl estradiol derived from a female contraceptive pill extract using the dynamic pH junction method, which resulted in over a 100-fold enhancement in concentration sensitivity.  相似文献   

13.
Xu Z  Hirokawa T 《Electrophoresis》2004,25(14):2357-2362
We developed a novel on-line preconcentration procedure for microchip gel electrophoresis (MCGE), which enables application of electrokinetic supercharging (EKS) for highly sensitive detection of DNA fragments on a cross-geometry microchip. In comparison with conventional pinched injection using the cross microchip, the present approach allows loading a much larger amount of the sample by taking advantage of a newly developed operational mode. In order to obtain high preconcentration effect and prevent splitting of an enriched sample into subchannels, i.e., off the detector range, effects of the voltage applied on the reservoirs and the time of isotachophoretic preconcentration were examined. The optimal balance between the voltage and time was found for a high-sensitivity analysis of DNA fragments. After experimental optimization the detection limit of a 150 bp fragment was as low as 0.22 mg/L (S/N = 3) that is 10 times better than using the conventional pinched injection.  相似文献   

14.
Breadmore MC  Haddad PR 《Electrophoresis》2001,22(12):2464-2489
One of the major problems facing the development of capillary electrophoresis (CE) is the relatively high limits of detection when compared to traditional high-performance liquid chromatographic (HPLC) methods. While the use of an alternative detector can offer better sensitivity, a more universal approach is sample preconcentration. Numerous on-line methods have been developed to improve the sensitivity of CE, and are based on electrophoretic principles, chromatographic principles, or a combination of both. This review will discuss all forms of on-line preconcentration methods for CE, with emphasis given to those that have shown particular merit when applied to inorganic and small organic anions.  相似文献   

15.
The research adopted a single-channel microchip as the probe, and focused electrokinetic injection combined with transient isotachophoresis preconcentration technique on capillary electrophoresis microchip to improve the analytical sensitivity of DNA fragments. The channel length, channel width and channel depth of the used microchip were 40.5 mm, and 110 and 50 μm, respectively. The separation was detected by CCD (charge-coupled device) (effective LENGTH=25 mm, 260 nm). A 1/100 diluted sample (0.2 mg/l of each DNA fragment) of commercially available stepladder DNA sample could be baseline separated in 120 s with S/N=2–5. Compared with conventional chip gel electrophoresis, the proposed method is ideally suited to improve the sensitivity of DNA analysis by chip electrophoresis.  相似文献   

16.
Jaafar  Jafariah  Konishi  Kanami  Terabe  Shigeru  Ikegami  Tohru  Tanaka  Nobuo 《Chromatographia》2009,69(11):1437-1441

A capillary electrophoresis method using indirect UV detection has been applied to the determination of arsenate [As(V)], arsenite [As(III)], monomethylarsonic acid and dimethylarsinic acid. The arsenic species were successfully separated in a successive multiple ionic polymer layer coated capillary. On-line sample preconcentration of arsenic compounds were performed by employing field enhanced sample injection. A baseline separation was achieved in a basic background solution of 10 mM 2,6-pyridinedicarboxylic acid at pH 10.3. The precision of migration time was 1.2–2.4% RSD and peak height was 8.1–12.9% RSD. The limits of detection at a S/N ratio of 3 for the four arsenic compounds were found to be 20–70 ppb, which are comparable to other on-line preconcentration techniques. The enhancement factor was improved by 230–1,500-fold.

  相似文献   

17.
A capillary electrophoresis method using indirect UV detection has been applied to the determination of arsenate [As(V)], arsenite [As(III)], monomethylarsonic acid and dimethylarsinic acid. The arsenic species were successfully separated in a successive multiple ionic polymer layer coated capillary. On-line sample preconcentration of arsenic compounds were performed by employing field enhanced sample injection. A baseline separation was achieved in a basic background solution of 10 mM 2,6-pyridinedicarboxylic acid at pH 10.3. The precision of migration time was 1.2–2.4% RSD and peak height was 8.1–12.9% RSD. The limits of detection at a S/N ratio of 3 for the four arsenic compounds were found to be 20–70 ppb, which are comparable to other on-line preconcentration techniques. The enhancement factor was improved by 230–1,500-fold.  相似文献   

18.
We developed and optimized a system coupling microchip capillary electrophoresis (MCE) and laser-induced fluorescence (LIF) detection for the analysis of microorganisms. The MCE-LIF system successfully separated pure cultures of lactic acid bacteria and Saccharomyces cerevisiae within 200 s. The results indicate that the MCE system can be conveniently used for the rapid and highly sensitive detection of microorganisms. Thus, MCE can provide a cheap and simple method for the on-line detection of microbial contamination.  相似文献   

19.
Determination of organic contaminants in food by capillary electrophoresis   总被引:1,自引:0,他引:1  
This review addresses recent advances in the analysis of organic contaminants, such as antibiotics, pesticides, biological toxins, and food-borne pathogens, in foods by capillary electrophoresis (CE). Special attention is paid to those aspects that increase sensitivity and/or selectivity, such as sample extraction and concentration, on-line preconcentration techniques (stacking), affinity capillaries or/and specific detectors (laser induced fluorescence (LIF), mass spectrometry (MS)). The various CE modes used to separate the compounds and the quantification strategies are also examined. As a result, this work presents an updated overview on the principal applications of CE, together with a discussion of their main advantages and drawbacks, and an outline of future trends in the analysis of organic contaminants in food.  相似文献   

20.
Electrophoretic separations on microfluidic chips   总被引:1,自引:0,他引:1  
Wu D  Qin J  Lin B 《Journal of chromatography. A》2008,1184(1-2):542-559
This review presents a brief outline and novel developments of electrophoretic separation in microfluidic chips. Distinct characteristics of microchip electrophoresis (MCE) are discussed first, in which sample injection plug, joule heat, channel turn, surface adsorption and modification are introduced, and some successful strategies and recognized conclusions are also included. Important achievements of microfluidic electrophoresis separation in small molecules, DNA and protein are then summarized. This review is aimed at researchers, who are interested in MCE and want to adopt MCE as a functional unit in their integrated microsystems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号