 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundT2-weighted, two-point Dixon fast-spin-echo (FSE) is an effective technique for magnetic resonance neurography (MRN) that can provide quantitative assessment of muscle denervation. Low signal-to-noise ratio and inadequate fat suppression, however, can impede accurate interpretation.PurposeTo quantify effects of principal component analysis (PCA) denoising on tissue signal intensities and fat fraction (FF) and to determine qualitative image quality improvements from both denoising and water-weighting (WW) algorithms to improve nerve conspicuity and fat suppression.Study typeProspective.SubjectsTwenty-one subjects undergoing MR neurography evaluation (11/10 male/female, mean age = 46.3±13.7 years) with 60 image volumes. Twelve subjects (23 image volumes) were determined to have muscle denervation based on diffusely elevated T2 signal intensity.Field strength/sequence3 T, 2D, two-point Dixon FSE.AssessmentQualitative assessment included overall image quality, nerve conspicuity, fat suppression, pulsation and ringing artifacts by 3 radiologists separately on a three-point scale (1 = poor, 2 = average, 3 = excellent). Quantitative measurements for FF and signal intensity relative to normal muscle were made for nerve, abnormal muscle and subcutaneous fat.Statistical testsLinear and ordinal regression models were used for quantitative and qualitative comparisons, respectively; 95% confidence intervals (CIs) and p-values for pairwise comparisons were adjusted using the Holm-Bonferroni method. Inter-rater agreement was assessed using Gwet's agreement coefficient (AC2).ResultsSimulations showed PCA-denoising reduced FF error from 2.0% to 1.0%, and from 7.6% to 3.1% at noise levels of 10% and 30%, respectively. In human subjects, PCA-denoising did not change signal levels and FF quantitatively. WW decreased fat signal significantly (−83.6%, p < 0.001). Nerve conspicuity was improved by WW (odds ratio, OR = 5.8, p < 0.001). Fat suppression was improved by both PCA (OR = 3.6, p < 0.001) and WW (OR = 2.2, p < 0.001). Overall image quality was improved by PCA + WW (OR = 1.7, p = 0.04).ConclusionsWW and PCA-denoising improved nerve conspicuity and fat suppression in MR neurography. Denoising can potentially provide improved accuracy of FF maps for assessing fat-infiltrated muscle.  相似文献   

2.
BackgroundCardiac magnetic resonance (CMR) flow quantification is typically performed using 2D phase-contrast (PC) imaging of a plane perpendicular to flow. 3D-PC imaging (4D-flow) allows offline quantification anywhere in a thick slab, but is often limited by suboptimal signal, potentially alleviated by contrast enhancement. We developed a non-contrast 4D-flow sequence, which acquires multiple overlapping thin slabs (MOTS) to minimize signal loss, and hypothesized that it could improve image quality, diagnostic accuracy, and aortic flow measurements compared to non-contrast single-slab approach.MethodsWe prospectively studied 20 patients referred for transesophageal echocardiography (TEE), who underwent CMR (GE, 3 T). 2D-PC images of the aortic valve and three 4D-flow datasets covering the heart were acquired, including single-slab, pre- and post-contrast, and non-contrast MOTS. Each 4D-flow dataset was interpreted blindly for ≥moderate valve disease and compared to TEE. Flow visualization through each valve was scored (0 to 4), and aortic-valve flow measured on each 4D-flow dataset and compared to 2D-PC reference.ResultsDiagnostic quality visualization was achieved with the pre- and post-contrast 4D-flow acquisitions in 25% and 100% valves, respectively (scores 0.9 ± 1.1 and 3.8 ± 0.5), and in 58% with the non-contrast MOTS (1.6 ± 1.1). Accuracy of detection of valve disease was 75%, 92% and 82%, respectively. Aortic flow measurements were possible in 53%, 95% and in 89% patients, respectively. The correlation between pre-contrast single-slab measurements and 2D-PC reference was weak (r = 0.21), but improved with both contrast enhancement (r = 0.71) and with MOTS (r = 0.67).ConclusionsAlthough non-contrast MOTS 4D-flow improves valve function visualization and diagnostic accuracy, a significant proportion of valves cannot be accurately assessed. However, aortic flow measurements using non-contrast MOTS is feasible and reaches similar accuracy to that of contrast-enhanced 4D-flow.  相似文献   

3.
PurposeThe purpose of this paper is to investigate whether the IVIM parameters (D, D *, f) helps to determine the molecular subtypes and histological grades of breast cancer.MethodsFifty-one patients with breast cancer were included in the study. All subjects were examined by 3 T Magnetic Resonance Imaging (MRI). Diffusion-weighted imaging (DWI) was undertaken with 16 b-values. IVIM parameters [D (true diffusion coefficient), D* (pseudo-diffusion coefficient), f (perfusion fraction)] were calculated. Histopathological reports were reviewed to histological grade, histological type, and immunohistochemistry. IVIM parameters of tumors with different histological grades and molecular subtypes were compared.ResultsD* and f were significantly different between molecular subtypes (p = 0.019, p = 0.03 respectively). D* and f were higher in the HER-2 group and lower in Triple negative (−) group (D*:36.8 × 10−3 ± 5.3 × 10−3 mm2/s, f:29.5%, D*:29.8 × 10−3 ± 5.6 × 10−3 mm2/s, f:21.5% respectively). There was a significant difference in D* and f between HER-2 and Triple (−) subgroups (p = 0,028, p = 0.024, respectively). D* was also significantly different between the HER-2 group and the Luminal group (p = 0,041). While histological grades increase, D and f values tend to decrease, and D* tends to increase. While the Ki-67 index increases, D* and f values tend to increase, and D tend to decrease.ConclusionD* and f values measured with IVIM imaging were useful for assessing breast cancer molecular subtyping. IVIM imaging may be an alternative to breast biopsy for sub-typing of breast cancer with further research.  相似文献   

4.
PurposeTo elucidate the influence of through-plane heart motion on the assessment of aortic regurgitation (AR) severity using phase contrast magnetic resonance imaging (PC-MRI).ApproachA patient cohort with chronic AR (n = 34) was examined with PC-MRI. The regurgitant volume (RVol) and fraction (RFrac) were extracted from the PC-MRI data before and after through-plane heart motion correction and was then used for assessment of AR severity.ResultsThe flow volume errors were strongly correlated to aortic diameter (R = 0.80, p < 0.001) with median (IQR 25%;75%): 16 (14; 17) ml for diameter>40mm, compared with 9 (7; 10) ml for normal aortic size (p < 0.001). RVol and RFrac were underestimated (uncorrected:64 ± 37 ml and 39 ± 17%; corrected:76 ± 37 ml and 44 ± 15%; p < 0.001) and ~ 20% of the patients received lower severity grade without correction.ConclusionThrough-plane heart motion introduces relevant flow volume errors, especially in patients with aortic dilatation that may result in underestimation of the severity grade in patients with chronic AR.  相似文献   

5.
PurposeTo investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT).MethodsA total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR TT. The age range was 4–81 years with a median of 32 years (interquartile range, 15 to 56 years).ResultsAnalysis time per patient was < 5 min. The peak longitudinal strain (Ell) was − 22.11 ± 3.51%. The peak circumferential strains (Ecc) for global, basal, mid-cavity and apical segments were as follows: − 11.69 ± 2.25%, − 11.00 ± 2.45%, − 11.17 ± 3.36%, − 12.90 ± 3.34%. There were significant gender differences in peak Ecc at the base (P = 0.04) and the mid-cavity (P = 0.03) with greater deformation in females than in males. On Bland-Altman analysis, peak Ell (mean bias, 0.22 ± 1.67; 95% CI − 3.05 to 3.49) and mid-cavity Ecc (mean bias, 0.036 ± 1.75; 95% CI, − 3.39 to 3.47) had the best intra-observer agreement and inter-observer agreement, respectively.ConclusionsRV longitudinal and circumferential strains can be quickly assessed with good intra-observer and inter-observer variability using TT.  相似文献   

6.
BackgroundFerumoxytol, an FDA-approved superparamagnetic iron oxide nanoparticle (SPION) preparation used for the treatment of iron deficiency anemia, is also known to be taken up by macrophages in areas of infection or inflammation, where it produces negative contrast changes on T2-weighted MR images.PurposeWe sought to compare Ferumoxytol-induced MRI contrast changes with those observed using standard-of-care Gadolinium in patients presenting with symptoms suggestive of osteomyelitis.SubjectsOut of eighteen enrolled patients, 15 had MR imaging with both ferumoxytol and gadolinium. Based on clinical and/or pathologic criteria, 7 patients were diagnosed with osteomyelitis, 5 patients had osteomyelitis ruled out, and in 3 patients a definitive diagnosis could not be made.Field strength1.5 Tesla.SequencesUsed included STIR, T1-weighted and T2-weighted spin echo.AssessmentThe mean contrast changes upon ferumoxytol and gadolinium administration were measured from lesion regions of interest and compared with control regions.Statistical testsStudent's t-test, propagation of errors. Data are reported as means ± S.E.ResultsThe mean contrast changes, ΔC, associated with a diagnosis of osteomyelitis were found to be ΔCFe = −2.7 ± 0.7 when Ferumoxytol and T2w imaging sequences were used and ΔCGd = +3.1 ± 1.1 (P < 0.001) when Gadolinium and a T1w imaging sequence was used. The MRI contrast changes for both agents correlated with systemic markers of inflammation, such as the erythrocyte sedimentation rate. In patients without osteomyelitis, no significant contrast changes were observed in T2-weighted, Ferumoxytol-contrasted MRI. The macrophages in osteomyelitic lesions were found to take up at least 16 times as much iron as benign bone marrow.Data conclusionWe conclude that in terms of its MRI diagnostic accuracy for osteomyelitis Ferumoxytol-contrasted MRI is a promising approach for diagnosing osteomyelitis that merits further study.  相似文献   

7.
PurposeWe aimed to investigate whether quantitative diffusivity variables of healthy ovaries vary during the menstrual cycle and to evaluate alterations in women using oral contraceptives (OC).MethodsThis prospective study (S-339/2016) included 30 healthy female volunteers, with (n = 15) and without (n = 15) intake of OC between 07/2017 and 09/2019. Participants underwent 3T diffusion-weighted MRI (b-values 0–2000 s/mm2) three times during a menstrual cycle (T1 = day 1–5; T2 = day 7–12; T3 = day 19–24). Both ovaries were manually three-dimensionally segmented on b = 1500 s/mm2; apparent diffusion coefficient (ADC) calculation and kurtosis fitting (Dapp, Kapp) were performed. Differences in ADC, Dapp and Kapp between time points and groups were compared using repeated measures ANOVA and t-test after Shapiro-Wilk and Brown-Forsythe test for normality and equal variance.ResultsIn women with a natural menstrual cycle, ADC and kurtosis variables showed significant changes in ovaries with the dominant follicle between T1 vs T2 and T1 vs T3, whilst no differences were observed between T2 vs T3: ADC ± SD for T1 1.524 ± 0.160, T2 1.737 ± 0.160, and T3 1.747 ± 0.241 μm2/ms (p = 0.01 T2 vs T1; p = 1.0 T2 vs T3, p = 0.003 T3 vs T1); Dapp ± SD for T1 2.018 ± 0.140, T2 2.272 ± 0.189, and T3 2.230 ± 0.256 μm2/ms (p = 0.003 T2 vs T1, p = 1.0 T2 vs T3, p = 0.02 T3 vs T1); Kapp ± SD for T1 0.614 ± 0.0339, T2 0.546 ± 0.0637, and T3 0.529 ± 0.0567 (p < 0.001 T2 vs T1, p = 0.86 T2 vs T3, p < 0.001 T3 vs T1). No significant differences were found in the contralateral ovaries or in females taking OC.ConclusionPhysiological cycle-dependent changes in quantitative diffusivity variables of ovaries should be considered especially when interpreting radiomics analyses in reproductive women.  相似文献   

8.
ObjectiveThe purpose of this study was to correlate brain metabolism assessed shortly after therapeutic hyperthermia by 1H magnetic resonance spectroscopy (MRS), with neurodevelopmental outcome.MethodsAt the age of 6.0 ± 1.8 days, brain metabolites of 35 term asphyxiated newborns, treated with therapeutic hypothermia, were quantified by multivoxel proton MRS of a volume cranial to the corpus callosum, containing both gray and white matter. At the age of 30 months the Bayley Scale of Infant Development-III was performed.ResultsInfants that died had lower gray matter NAA levels than infants that survived (P = 0.005). In surviving infants (28 of 35) there was a trend of negative correlation between gray matter choline levels and gross motor outcome (r =  0.45). In the white matter, choline correlated negatively with fine motor skills (r =  0.40), and creatine positively with gross motor skills (r = 0.58, P = 0.02). There was no relationship between lactate levels and outcome.ConclusionMRS of asphyxiated neonates treated by therapeutic hypothermia can serve as predictor of outcome. Unlike previously reported associations in untreated asphyxiates, lactate levels had no relationship with outcome, which indicates that one of the working mechanisms of therapeutic hypothermia is reduction of the metabolic rate.  相似文献   

9.
BackgroundTo evaluate 3-dimensional amide proton transfer weighted (APTw) imaging for type I endometrial carcinoma (EC), and investigate correlations of Ki-67 labelling index with APTw and intravoxel incoherent motion (IVIM) imaging.Methods54 consecutive patients suspected of endometrial lesions underwent pelvic APTw and IVIM imaging on a 3 T MR scanner. APTw values and IVIM-derived parameters (Dt, D*, f) were independently measured by two radiologists on 22 postoperative pathological confirmed of type I EC lesions. Results were compared between histological grades and Ki-67 proliferation groups. ROC analysis was performed. Pearson's correlation analysis was performed for APTw values and IVIM-derived parameters with Ki-67 labeling index.ResultsAPTw values and Dt, D*, f of all type I EC were 2.9 ± 0.1%, 0.677 ± 0.027 × 10−3 mm2/s, 31.801 ± 11.492 × 10−3 mm2/s, 0.179 ± 0.050 with inter-observer ICC 0.996, 0.850, 0.956, 0.995, respectively. APTw values of Ki-67 low-proliferation group (<30%, n = 8) were 2.5 ± 0.2%, significantly lower than the high-proliferation group (>30%, n = 14) with APTw values of 3.1 ± 0.1% (p = 0.016). Area under the curve was 0.768. APTw values of type I EC were moderately positively correlated with Ki-67 labelling index (r = 0.583, p = 0.004). There was no significant difference of Dt (p = 0.843), D* (p = 0.262), f (p = 0.553) between the two groups. No correlation was found between IVIM-derived parameters and Ki-67 labelling index (Dt, p = 0.717; D* p = 0.151; f, p = 0.153).Conclusion3D TSE APTw imaging is a feasible approach for detecting type I EC. Ki-67 labeling index positively moderately correlates with APTw not with IVIM.  相似文献   

10.
Rationale and objectivesIn magnetic resonance (MR) fetal imaging, the image quality acquired by the traditional Cartesian-sampled breath-hold T1-weighted (T1W) sequence may be degraded by motion artifacts arising from both mother and fetus. The radial VIBE sequence is reported to be a viable alternative to conventional Cartesian acquisition for both pediatric and adult MR, yielding better image quality. This study evaluated the role of radial VIBE in fetal MR imaging and compared its image quality and motion artifacts with those of the Cartesian T1W sequence.Materials and methodsWe included 246 pregnant women with 50 lesions on 1.5-T MR imaging. Image quality and lesion conspicuity were evaluated by two radiologists, blinded to the acquisition schemes used, using a five-point scale, where a higher score indicated a better trajectory method. Mixed-model analysis of variance and interobserver variability assessment were performed.ResultsThe radial VIBE sequence showed a significantly better performance than conventional T1W imaging in the head and neck, fetal body, and placenta region: 3.92 ± 0.88 vs 3 ± 0.74, p < 0.001, 3.8 ± 0.94 vs 3.15 ± 0.87, p < 0.001, and 4.17 ± 0.63 vs 3.12 ± 0.72, p < 0.001, respectively. Additionally, fewer motion artifacts were observed in all regions with the radial VIBE sequence (p < 0.01). Of 50 lesions, 49 presented better lesion conspicuity on radial VIBE images than on T1W images (4.34 ± 0.91 vs 3.48 ± 1.46, p < 0.001).ConclusionFor fetal imaging, the radial VIBE sequences yielded better image quality and lesion conspicuity, with fewer motion artifacts, than conventional breath-hold Cartesian-sampled T1W sequences.  相似文献   

11.
PurposeQuantification of myocardial oxygenation (MO) in heart failure (HF) has been less than satisfactory. This has necessitated the use of invasive techniques to measure MO directly or to determine the oxygen demand during exercise using the cardiopulmonary exercise (CPX) test. We propose a new quantification method for MO using blood-oxygen-level-dependent (BOLD) myocardial T2* magnetic resonance imaging (M-T2* MRI), and investigate its correlation with CPX results.MethodsThirty patients with refractory HF who underwent cardiac MRI and CPX test for heart transplantation, and 24 healthy, age-matched volunteers as controls were enrolled. M-T2* imaging was performed using a 3-Tesla and multi-echo gradient-echo sequence. M-T2* was calculated by fitting the signal intensity data for the mid-left ventricular septum to a decay curve. M-T2* was measured under room-air (T2*-air) and after inhalation of oxygen for 10 min at a flow rate of 10 L/min (T2*-oxy). MO was defined as the difference between the two values (ΔT2*). Changes in M-T2* at the two conditions and ΔT2* between the two groups were compared. Correlation between ΔT2* and CPX results was analyzed using the Pearson coefficient.ResultsT2*-oxy was significantly greater than T2*-air in patients with HF (29.9 ± 7.3 ms vs. 26.7 ± 6.0 ms, p < 0.001), whereas no such difference was observed in controls (25.5 ± 4.0 ms vs. 25.4 ± 4.4 ms). ΔT2* was significantly greater for patients with HF than for controls (3.2 ± 4.5 ms vs. -0.1 ± 1.3 ms, p < 0.001). A significant correlation between ΔT2* and CPX results (peak VO2, r =  0.46, p < 0.05; O2 pulse, r =  0.54, p < 0.005) was observed.ConclusionΔT2* is increased T2*-oxy is greater in patients with HF, and is correlated with oxygen metabolism during exercise as measured by the CPX test. Hence, ΔT2* can be used as a surrogate marker of MO instead of CPX test.  相似文献   

12.
PurposeTo test the diagnostic performance of cardiovascular magnetic resonance (CMR) tissue-tracking (TT) to detect the presence of late gadolinium enhancement (LGE) in patients with a diagnosis of myocardial infarction (MI) or myocarditis (MYO), preserved left ventricular ejection fraction (LVEF) and no visual regional wall motion abnormalities (RWMA).MethodsWe selected consecutive CMR studies of 50 MI, 50 MYO and 96 controls. Receiving operating characteristic (ROC) curve and net reclassification index (NRI) analyses were used to assess the predictive ability and the incremental diagnostic yield of 2D and 3D TT-derived strain parameters for the detection of LGE and to measure the best cut-off values of strain parameters.ResultsOverall, cases showed significantly reduced 2D global longitudinal strain (2D-GLS) values compared with controls (−20.1 ± 3.1% vs −21.6 ± 2.7%; p = 0.0008). 2D-GLS was also significantly reduced in MYO patients compared with healthy controls (−19.7 ± 2.9% vs −21.9 ± 2.4%; p = 0.0001). 3D global radial strain (3D-GRS) was significantly reduced in MI patients compared with controls with risk factors (34.3 ± 11.8% vs 40.3 ± 12.5%, p = 0.024) Overall, 2D-GLS yielded good diagnostic accuracy for the detection of LGE in the MYO subgroup (AUROC 0.79; NRI (95% CI) = 0.6 (0.3, 1.02) p = 0.0004), with incremental predictive value beyond risk factors and LV function parameters (p for AUROC difference = 0.048). In the MI subgroup, 2D-GRS (AUROC 0.81; NRI (95% CI) = 0.56 (0.17, 0.95) p = 0.004), 3D-GRS (AUROC 0.82; NRI (95% CI) = 0.57 (0.17, 0.97) p = 0.006) and 3D global circumferential strain (3D-GCS) (AUROC 0.81; NRI (95% CI) = 0.62 (0.22, 1.01) p = 0.002) emerged as potential markers of disease. The best cut-off for 2D-GLS was −21.1%, for 2D- and 3D-GRS were 39.1% and 37.7%, respectively, and for 3D-GCS was −16.4%.ConclusionsAt CMR-tissue tracking analysis, 2D-GLS was a significant predictor of LGE in patients with myocarditis but preserved LVEF and no visual RWMA. Both 2D- and 3D-GRS and 2D-GCS yielded good diagnostic accuracy for LGE detection in patients with previous MI but preserved LVEF and no visual RWMA.  相似文献   

13.
PurposeTo develop and validate an accelerated free-breathing 3D whole-heart magnetic resonance angiography (MRA) technique using a radial k-space trajectory with compressed sensing and curvelet transform.MethodA 3D radial phyllotaxis trajectory was implemented to traverse the centerline of k-space immediately before the segmented whole-heart MRA data acquisition at each cardiac cycle. The k-space centerlines were used to correct the respiratory-induced heart motion in the acquired MRA data. The corrected MRA data were then reconstructed by a novel compressed sensing algorithm using curvelets as the sparsifying domain. The proposed 3D whole-heart MRA technique (radial CS curvelet) was then prospectively validated against compressed sensing with a conventional wavelet transform (radial CS wavelet) and a standard Cartesian acquisition in terms of scan time and border sharpness.ResultsFifteen patients (females 10, median age 34-year-old) underwent 3D whole-heart MRA imaging using a standard Cartesian trajectory and our proposed radial phyllotaxis trajectory. Scan time for radial phyllotaxis was significantly shorter than Cartesian (4.88 ± 0.86 min. vs. 6.84 ± 1.79 min., P-value = 0.004). Radial CS curvelet border sharpness was slightly lower than Cartesian and, for the majority of vessels, was significantly better than radial CS wavelet (P-value < 0.050).ConclusionThe proposed technique of 3D whole-heart MRA acquisition with a radial CS curvelet has a shorter scan time and slightly lower vessel sharpness compared to the Cartesian acquisition with radial profile ordering, and has slightly better sharpness than radial CS wavelet. Future work on this technique includes additional clinical trials and extending this technique to 3D cine imaging.  相似文献   

14.
BackgroundFeature tracking (FT) has emerged as a promising method to quantify myocardial strain using conventional cine magnetic resonance imaging (MRI). Extracellular volume fraction (ECV) by T1 mapping enables quantification of myocardial fibrosis. To date, the correlation between FT-derived left ventricular strain and ECV has not been elucidated yet. The aim of this study was to evaluate the relationship between myocardial strain by FT and ECV by T1 mapping in patients with non-ischemic dilated cardiomyopathy (NIDCM).MethodsA total of 57 patients with NIDCM (61 ± 12 years; 46 (81%) male)) and 15 controls (62 ± 11 years; 11 (73%) male)) were studied. Using a 1.5 T magnetic resonance scanner, pre- and post- T1 mapping images of the LV wall at the mid-ventricular level were acquired to calculate the ECV by a modified Look-Locker inversion recovery (MOLLI) sequence. The radial strain (RS), circumferential strain (CS), and longitudinal strain (LS) were assessed by the FT technique. The ECV and myocardial strain were compared using a 6-segment model at the mid-ventricular level.ResultsThe ECV and myocardial strain were evaluable in all 432 segments in 72 subjects. On a patient-based analysis, NIDCM patients had a significantly higher ECV (0.30 ± 0.07 vs. 0.28 ± 0.06, p = .007) and impaired myocardial strain than the control subjects (RS, 22.7 ± 10.3 vs. 30.3 ± 18.2, p < .01; CS, −6.47 ± 1.89 vs. −9.52 ± 5.15, p < .001; LS −10.2 ± 3.78 vs. −19.8 ± 4.30, p < .001, respectively). A significant linear correlation was found between the RS and ECV (r = −0.38, p < .001) and CS and ECV, (r = 0.38, p < .001). LS and ECV also correlated (r = 0.31, p < 0.001). On a segment-based analysis, there was a significant correlation between the ECV and RS and ECV and CS (all p values < .05). The intraclass correlation coefficient was good for the strain measurement (>0.80).ConclusionsIn patients with NIDCM, significant correlation was found between myocardial strain and ECV, suggesting the FT-derived myocardial strain might be useful as a non-invasive imaging marker for the detection of myocardial fibrosis without any contrast media.  相似文献   

15.
BackgroundAlthough cardiac magnetic resonance (CMR) can accurately quantify global left ventricular strain using feature tracking (FT), it has been suggested that FT cannot reliably quantify regional strain. We aimed to determine whether abnormalities in regional strain measured using FT can be detected within areas of myocardial scar and to determine the extent to which the regional strain measurement is impacted by LV ejection fraction (EF).MethodsWe retrospectively studied 96 patients (46 with LVEF ≤ 40%, 50 with LVEF > 40%) with coronary artery disease and a late gadolinium enhancement (LGE) pattern consistent with myocardial infarction, who underwent CMR imaging (1.5T). Regional peak systolic longitudinal and circumferential strains (RLS, RCS) were measured within LGE and non-LGE areas. Linear regression analysis was performed for strain in both areas against LVEF to determine whether the relationship between strain and LGE holds across the LV function spectrum. Receiver-operating curve (ROC) analysis was performed in 33 patients (derivation cohort) to optimize strain cutoff, which was tested in the remaining 63 patients (validation cohort) for its ability to differentiate LGE from non-LGE areas.ResultsBoth RLS and RCS magnitudes were reduced in LGE areas: RLS = −10.4 ± 6.2% versus −21.0 ± 8.5% (p < 0.001); RCS = −10.4 ± 6.0% versus −18.9 ± 8.6%, respectively (p < 0.001), but there was considerable overlap between LGE and non-LGE areas. Linear regression revealed that it was partially driven by the natural dependence between strain and EF, suggesting that EF-corrected strain cutoff is needed to detect LGE. ROC analysis showed the ability of both RLS and RCS to differentiate LGE from non-LGE areas: area under curve 0.95 and 0.89, respectively. In the validation cohort, optimal cutoffs of RLS/EF = 0.36 and RCS/EF = 0.37 yielded sensitivity, specificity and accuracy 0.74–0.78.ConclusionAbnormalities in RLS and RCS within areas of myocardial scar can be detected using CMR-FT; however, LVEF must be accounted for.  相似文献   

16.
ObjectiveThe complex anatomical structures of cerebellopontine angle (CPA) pose a unique challenge to diffusion weighted imaging (DWI). This study aimed to compare the clinical utility of the prototypic 2D turbo gradient- and spin echo-BLADE-DWI (TGSE-BLADE-DWI) with that of readout-segmented echo-planar DWI (RESOLVE-DWI) and single-shot echo-planar DWI (SS-EPI-DWI) to visualize CPA anatomic structures and identify CPA tumors.MethodsA total of 8 volunteers and 36 patients with pathological CPA tumors were enrolled to perform the three DWI sequences at 3 T. Scan time of TGSE-BLADE-DWI, RESOLVE-DWI and SS-EPI-DWI was 5 min 51 s, 5 min 15 s and 1 min 22 s, respectively. Subjective analysis, including visualization of anatomical structures, geometric distortion, ghosting artifacts, lesion conspicuity, diagnostic confidence, and overall image quality of the three DWI sequences were scored and assessed. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of CPA tumors were measured and compared.ResultsA total of 39 lesions were identified, TGSE-BLADE-DWI detected all of them, RESOLVE-DWI 36 and SS-EPI-DWI 27. Significant differences were found in all the subjective parameters among the three DWI sequences (all p < 0.001). TGSE-BLADE-DWI was significantly better than RESOLVE-DWI in visualization of CPA anatomical structures, geometric distortion, ghosting artifacts, lesion conspicuity, diagnostic confidence, and overall image quality (all p < 0.01), and RESOLVE-DWI showed significantly superior performance than SS-EPI-DWI in all parameters (all p < 0.001). CNRs and ADCs were not significantly different among the three DWI sequences (p = 0.355, p = 0.590, respectively). No significant differences were detected between TGSE-BLADE-DWI SNR and RESOLVE-DWI SNR (p = 0.058), or TGSE-BLADE-DWI SNR and SS-EPI-DWI SNR (p = 0.155).ConclusionCompared with RESOLVE-DWI and SS-EPI-DWI, TGSE-BLADE-DWI minimized geometric distortions and ghosting artifacts and demonstrated an improved ability for depicting CPA tumors with better lesion conspicuity.SummaryGeometric distortions and ghosting artifacts are found at bone-air interfaces using conventional diffusion-weighted imaging (DWI), which is a challenge for imaging cerebellopontine angle (CPA) tumors. Our study validated that geometric distortions and ghosting artifacts were not present on 2D turbo gradient- and spin-echo-BLADE-DWI scans, making this technique useful for visualizing CPA anatomic structures and diagnosing CPA tumors.  相似文献   

17.
PurposeTo develop and evaluate a novel non-ECG triggered 2D magnetic resonance fingerprinting (MRF) sequence allowing for simultaneous myocardial T1 and T2 mapping and cardiac Cine imaging.MethodsCardiac MRF (cMRF) has been recently proposed to provide joint T1/T2 myocardial mapping by triggering the acquisition to mid-diastole and relying on a subject-dependent dictionary of MR signal evolutions to generate the maps. In this work, we propose a novel “free-running” (non-ECG triggered) cMRF framework for simultaneous myocardial T1 and T2 mapping and cardiac Cine imaging in a single scan. Free-running cMRF is based on a transient state bSSFP acquisition with tiny golden angle radial readouts, varying flip angle and multiple adiabatic inversion pulses. The acquired data is retrospectively gated into several cardiac phases, which are reconstructed with an approach that combines parallel imaging, low rank modelling and patch-based high-order tensor regularization. Free-running cMRF was evaluated in a standardized phantom and ten healthy subjects. Comparison with reference spin-echo, MOLLI, SASHA, T2-GRASE and Cine was performed.ResultsT1 and T2 values obtained with the proposed approach were in good agreement with reference phantom values (ICC(A,1) > 0.99). Reported values for myocardium septum T1 were 1043 ± 48 ms, 1150 ± 100 ms and 1160 ± 79 ms for MOLLI, SASHA and free-running cMRF respectively and for T2 of 51.7 ± 4.1 ms and 44.6 ± 4.1 ms for T2-GRASE and free-running cMRF respectively. Good agreement was observed between free-running cMRF and conventional Cine 2D ejection fraction (bias = −0.83%).ConclusionThe proposed free-running cardiac MRF approach allows for simultaneous assessment of myocardial T1 and T2 and Cine imaging in a single scan.  相似文献   

18.
PurposeWhen magnetic resonance imaging (MRI) is performed on patients carrying metallic implants, artifacts can disturb the images around the implants, often making it difficult to interpret them appropriately. However, metallic materials are and will be indispensable as raw materials for medical devices because of their electric conductivity, visibility under X-ray fluoroscopy, and other favorable features. What is now desired is to develop a metallic material which causes no artifacts during MRI.Materials and methodsIn the present study, we prepared a single-phase and homogeneous Au-Pt alloys (Au; diamagnetic metal, and Pt; paramagnetic metal) by the processing of thermal treatment. Volume magnetic susceptibility was measured with a SQUID Flux Meter and MRI artifact was evaluated using a 1.5-T scanner.ResultsAfter final thermal treatment, an entirely recrystallized homogeneous organization was noted. The Au-35Pt alloy was shown to have a volume magnetic susceptibility of − 8.8 ppm, causing almost free from artifacts during MRI.ConclusionsWe thus prepared an Au-35Pt alloy which had a magnetic susceptibility very close to that of living tissue and caused much fewer artifacts during MRI. It is promising as a material for spinal cages, intracranial electrodes, cerebral aneurysm embolization coils, markers for MRI and so on.  相似文献   

19.
PurposeTo evaluate the feasibility of 3D fast spin-echo (FSE) imaging with compressed sensing (CS) for the assessment of shoulder.Materials and methodsTwenty-nine patients who underwent shoulder MRI including image sets of axial 3D-FSE sequence without CS and with CS, using an acceleration factor of 1.5, were included. Quantitative assessment was performed by calculating the root mean square error (RMSE) and structural similarity index (SSIM). Two musculoskeletal radiologists compared image quality of 3D-FSE sequences without CS and with CS, and scored the qualitative agreement between sequences, using a five-point scale. Diagnostic agreement for pathologic shoulder lesions between the two sequences was evaluated.ResultsThe acquisition time of 3D-FSE MRI was reduced using CS (3 min 23 s vs. 2 min 22 s). Quantitative evaluations showed a significant correlation between the two sequences (r = 0.872–0.993, p < 0.05) and SSIM was in an acceptable range (0.940–0.993; mean ± standard deviation, 0.968 ± 0.018). Qualitative image quality showed good to excellent agreement between 3D-FSE images without CS and with CS. Diagnostic agreement for pathologic shoulder lesions between the two sequences was very good (κ = 0.915–1).ConclusionsThe 3D-FSE sequence with CS is feasible in evaluating the shoulder joint with reduced scan time compared to 3D-FSE without CS.  相似文献   

20.
PurposeThis study investigated whether T1 values in native T1 mapping of 3T magnetic resonance imaging (MRI) of the liver were affected by the fatty component.MethodsThis prospective study involved 340 participants from a population-based cohort study between May 8, 2018 and August 8, 2019. Data obtained included: (1) hepatic stiffness according to magnetic resonance elastography (MRE); (2) T1 value according to T1 mapping; (3) fat fraction and iron concentration from multi-echo Dixon; and (4) clinical indices of hepatic steatosis including body mass index, waist circumference, history of diabetes, aspartate aminotransferase, alanine aminotransferase, gamma-glutamyl transpeptidase, and triglycerides. The correlations between T1 value and fat fraction, and between T1 value and liver stiffness were assessed using Pearson's correlation coefficient. The independent two-sample t-test was used to evaluate the differences in T1 values according to the presence or absence of hepatic steatosis, and the one-way analysis of variance was used to evaluate the difference in T1 value by grading of hepatic steatosis according to MRI-based proton density fat fraction (PDFF). In addition, univariate and multivariate linear regression analyses were performed to determine whether other variables influenced the T1 value.ResultsT1 value showed a positive correlation with the fat fraction obtained from PDFF (r = 0.615, P < 0.001) and with the liver stiffness obtained from MRE (r = 0.370, P < 0.001). Regardless of the evaluation method, the T1 value was significantly increased in subjects with hepatic steatosis (P < 0.001). When comparing hepatic steatosis grades based on MRI-PDFF, the mean T1 values were significantly different in all grades, and the T1 value tended to increase as the grade increased (P < 0.001, P for trend <0.001). On multiple linear regression analysis, the T1 value was influenced by MRI-PDFF, calculated liver iron concentration, liver stiffness, and serum aspartate aminotransferase level.ConclusionThe T1 value obtained by current T1 mapping of 3T MRI was affected by the liver fat component and several other factors such as liver stiffness, iron concentration, and inflammation.  相似文献   