首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
《Magnetic resonance imaging》1996,14(9):1053-1065
A segmentation method is presented for gray matter, white matter, and cerebrospinal fluid (CSF) in thinsliced single-channel brain magnetic resonance (MR) scans. The method is based on probabilistic modeling of intensity distributions and on a region growing technique. Interrater and intrarater reliabilities for the method were high, and comparison with phantom studies and hand-traced results from an experienced rater indicated good validity. The method was designed to account for spatially dependent image intensity inhomogeneities. Segmentation of MR brain scans of 105 (56 male and 49 female) healthy children and adolescents showed that although the total brain volume was stable over age 4–18, white matter increased and gray matter decreased significantly. There were no sex differences in total gray and white matter growth after correction for total brain volume. White matter volume increased the most in superior and posterior regions and laterality effects were seen in hemisphere tissue volumes. These findings are consistent with other reports, and further validate the segmentation technique.  相似文献   

4.
FSM在高精度瞄准线稳定系统中的应用研究   总被引:1,自引:0,他引:1  
快速反射镜(fast-steering mirrors,简称FSM)是一种精确控制光束方向的装置。提出用一种基于压电陶瓷驱动的FSM补偿稳瞄系统中粗级平台的残余误差的方法,可以提高系统稳定精度,同时对采用FSM的高精度稳瞄系统进行了仿真。仿真结果表明:粗级平台稳定误差为110 rad,通过FSM补偿后的系统稳定误差不大于8 rad,即采用该方法可将稳定精度提高一个数量级以上。  相似文献   

5.
Raman spectroscopy involves the interaction of light with the molecular vibrations and therefore can provide information about molecular structure, tissue composition and changes in its environment. We explored whether Raman spectroscopy can reliably distinguish mammary tumors from normal mammary tissues and other pathological states in mice. We analyzed a large number of Raman spectra from the tumor and normal mammary glands of mice injected with 4T1 tumor cells, which were collected using a high‐resolution (less than 4 cm−1) Raman spectrometer at a fixed (785 nm) laser excitation wavelength and with 60 mW of laser power. The spectra of normal and tumor mammary glands showed consistent differences in the intensity of certain Raman bands and loss of some bands in the tumor spectra. Multivariate statistical methods—principal component analysis (PCA) and discriminant functional analysis (DFA)—were used to separate the data into different groups of mammary tumors, mastitis, lymph nodes contralateral and tumor‐cell‐injected sides, and normal contralateral and tumor‐cell‐injected sides. We demonstrate that this spectroscopic technique has the feasibility of discriminating tumor and mastitis from normal tissues and other pathological states in a short period of time and may detect tumor transformation earlier than the standard histological examination stage. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

6.
This paper introduces an intelligent system of length measurement, which consists of a linear CCD, a grating, and a microcomputer. Because the system uses a new fine-divisions method of moiré fringes, the resolution is greatly increased. The theoretical analysis and the experimental results are given in this paper.  相似文献   

7.
PurposeTo compare diffusion-weighted imaging (DWI) and dynamic contrast-enhanced MR imaging (DCE-MRI) for characterization of prostate cancer (PC).Methods104 PC patients who underwent prostate multiparametric MRI at 3T including DWI and DCE-MRI before MRI-guided biopsy or radical prostatectomy. Apparent diffusion coefficient (ADC) with histogram analysis (mean, 0–25th percentile, skewness, and kurtosis), intravoxel incoherent motion model including D and f; stretched exponential model including distributed diffusion coefficient (DDC) and a; and permeability parameters including Ktrans, Kep, and Ve were obtained from a region of interest placed on the dominant tumor of each patient.ResultsADCmean, ADC025, D, DDC, and Ve were significantly lower and Kep was significantly higher in GS ≥ 3 + 4 tumors (n = 89) than in GS = 3 + 3 tumors (n = 15), and also in GS ≥ 4 + 3 tumors (n = 57) than in GS ≤ 3 + 4 tumors (n = 47) (P < 0.001 to P = 0.040). f was significantly lower in GS ≥ 4 + 3 tumors than in GS ≤ 3 + 4 tumors (P = 0.022), but there was no significant difference between GS = 3 + 3 tumors and GS ≥ 3 + 4 tumors, or between the remaining metrics in both comparisons. In metrics with area under the curve (AUC) >0.80, there was a significant difference in AUC between ADC025 and D, and DDC for separating GS ≤ 3 + 4 tumors from GS ≥ 4 + 3 tumors (P = 0.040 and P = 0.022, respectively). There were no significant differences between metrics with AUC > 0.80 for separating GS = 3 + 3 tumors from GS ≥ 3 + 4 tumors. ADC025 had the highest correlation with Gleason grade (ρ = −0.625, P < 0.001).ConclusionsDWI and DCE-MRI showed no apparent clinical superiority of non-Gaussian models or permeability MRI over the mono-exponential model for assessment of tumor aggressiveness in PC.  相似文献   

8.
折射-衍射混合高精度平行光管的设计   总被引:1,自引:2,他引:1       下载免费PDF全文
 平行光管是安装、调校、测试光学仪器的重要工具之一,也是光学量度仪器中的重要组成部分。为了提高平行光管的测量精度,利用衍射元件的特殊色差特性和像差特性,提出了折射-衍射混合平行光管的设计方案,系统的入瞳口径为80 mm,焦距为500 mm,系统总长小于550 mm。设计结果表明,系统的最大弥散斑直径为5.2 mm,角分辨率小于4.3″,在空间频率50 lp/mm处,系统的调制传递函数高于0.8,接近衍射极限。  相似文献   

9.
白维达  江涛  熊正锋  蒋自力 《强激光与粒子束》2020,32(5):053002-1-053002-4

倒相开关是能量倍增器法(SLED)脉冲压缩系统中的关键器件,它的倒相精度和开关速度对脉冲压缩系统的性能有重要影响。设计了一种工作在S波段的精度可调、响应迅速的微带反射式倒相开关,并对其进行了理论分析,电路结构设计和仿真研究。对倒相开关的反射终端进行了改进设计,利用一个变容二极管来代替传统的并联枝节电路,通过调节变容二极管的偏置电压改变反射终端的反射系数,从而实现对倒相相位的精确调节。仿真结果表明,倒相开关响应时间约4 ns,且通过调节变容二极管偏置电压可以在一定范围内调节倒相精度。

  相似文献   

10.
The purpose of this study was to measure normal cerebrospinal fluid (CSF) pulsations within the intracranial and upper cervical subarachnoid spaces and the ventricular system. Phase contrast cine MR sequences were performed in sagittal and axial planes on 13 volunteers with flow encoding in the craniocaudal direction. CSF pulsations displayed considerable variations in healthy subjects, depending both on measurements localization and subjects, with CSF peak velocities ranging from 0 to 7 cm/s. In the subarachnoid spaces, the highest velocities occurred in the anterior location and increased from the cerebellar pontine angle cisterns towards the lower cervical spaces. In the ventricular system, the highest velocities occurred through the aqueduct of Sylvius. CSF flow within the third ventricle seemed to reflect a circular motion. There was a caudal net CSF flow in the aqueduct whereas in the upper cervical spaces net CSF flow was caudal anteriorly and cranial laterally. Velocity profiles of CSF pulsations demonstrated arterial morphology. After the R wave, caudal systolic motion was first observed in the posterior subarachnoid spaces, soon after in the anterior subarachnoid spaces and later in the ventricular system. Considering the morphology of CSF pathways, three successively initiated phenomena may explain the temporal course of CSF motion: the systolic expansion of the main arteries at the base of the brain, the systolic expansion of the cerebrospinal axis and, finally, the systolic expansion of the choroid plexuses.  相似文献   

11.
Twelve soft tissue tumors preoperatively studied with magnetic resonance (MR) imaging contained areas of inhomogeneous intralesional signal intensity. The pathologist's selection of biopsy sites from gross specimens was based on specific MR images selected by a radiologist and depended on close cooperation between the radiologist and pathologist. The histopathology so sampled, further depended on the lesion's size, careful gross specimen orientation, discrete sampling, and a specially developed Grid Analysis technique. Our initial experience indicates that (1) histology may vary within different and often neighboring sites of a single soft tissue lesion; (2) that such variability is common in soft tissue tumors; (3) that histological variability within different sites of a single lesion influences signal heterogeneity; and (4) that although differing MR signal intensities per se are not tissue specific, MR may enhance the histopathological accuracy of pathologists who can be directed to particular gross specimen sites by magnetic resonance images. To our knowledge such a specific, detailed effort has not been made.  相似文献   

12.
A dextran-Gd-DTPA compound has been recently synthesized utilizing 70,800 Da molecular weight dextran. This polymeric contrast agent for magnetic resonance imaging has been found chemically to be very stable and to demonstrate in vitro improved relaxivities of 1.5 to 2.3 times that of monomeric Gd-DTPA at 100 MHz. This MR experiment examines the in vivo distribution and relaxivity of the 70,800 Da molecular weight dextran-Gd-DTPA compound in a rabbit model by measuring the change in signal-to-noise ratio of a variety of organs (renal cortex, renal medulla, liver, brain, and torcula herophile) compared to the preinjection state. Results demonstrate prolonged (beyond 60 min) enhancement of the renal cortex, renal medulla, liver and torcula, and no enhancement of brain parenchyma.  相似文献   

13.
We consider the effects of misalignment in a two-beam interferometer resulting from lateral displacement as well as angular misalignment of the beams. Furthermore, a technique to determine such misalignments is discussed and examples of measurement strategies and expected performance are given. It is found that, when the waist of the beam used to illuminate the interferometer is larger than 0.7 mm (∼1000λ), such an approach allows alignment to be made resulting in a relative interferometric error smaller than 1×10−10 provided that the diffraction effect is fully accounted for.  相似文献   

14.

Purpose

This retrospective study was designed to evaluate the apparent diffusion coefficient (ADC) of line scan diffusion images (LSDI) in normal prostate and prostate cancer. Single-shot echo planner images (SS-EPI) were used for comparison.

Materials and Methods

Twenty prostate tumors were examined by conventional MRI in 14 patients prior to radical prostatectomy. All patients were examined with a 1.5-T MR imager (Signa CV/i ver. 9.1 GE Medical System Milwaukee, WI, USA). Diffusion-weighted MR imaging (DWI) using LSDI was performed with a pelvic phased-array coil, with b values of 5 and 800 s/mm2. DWI using SS-EPI was performed with a body coil, with b values of 0 and 800 s/mm2. The ADCs of each sequence for 14 normal prostate and 20 prostate cancers were histopathologically assessed. Signal-to-noise ratio (SNR) on DWI was estimated and compared for each sequence.

Results

The mean ADCs (±S.D.) of normal peripheral zones (PZ), transition zones (TZ) and cancer (in 10−3 mm2/s) that used LSDI were 1.42±0.12, 1.23±0.10 and 0.79±0.19, respectively. Those that used SS-EPI were 1.76±0.26, 1.38±0.20 and 1.05±0.27, respectively. Using unpaired t test (P<.05), we found a significant difference in each sequence between normal tissue (both PZ and TZ) and the cancer. Paired t test (P<.05) also registered a significant difference between LSDI and SS-EPI. Mean SNR for DWI using LSDI was 16.49±5.03, while the DWI using SS-EPI was 18.85±9.26. The difference between the SNR of each sequence was not statistically significant by paired t test.

Conclusion

We found that ADCs using LSDI and SS-EPI showed similar tendencies in the same patients. However, in all regions, LSDI ADCs had smaller standard deviations than SS-EPI ADCs.  相似文献   

15.
The application of a raw data-based, operator-independent MR segmentation technique to differentiate boundaries of tumor from edema or hemorrhage is demonstrated. A case of a glioblastoma multiforme with gross and histopathologic correlation is presented. The MR image data set was segmented into tissue classes based on three different MR weighted image parameters (T1-, proton density-, and T2-weighted) using unsupervised fuzzy c-means (FCM) clustering algorithm technique for pattern recognition. A radiological examination of the MR images and correlation with fuzzy clustering segmentations was performed. Results were confirmed by gross and histopathology which, to the best of our knowledge, reports the first application of this demanding approach. Based on the results of neuropathologic correlation, the application of FCM MR image segmentation to several MR images of a glioblastoma multiforme represents a viable technique for displaying diagnostically relevant tissue contrast information used in 3D volume reconstruction. With this technique, it is possible to generate segmentation images that display clinically important neuroanatomic and neuropathologic tissue contrast information from raw MR image data.  相似文献   

16.
17.
The aim of the present investigation was to determine spin lock (SL) relaxation parameters for the normal brain tissues and thus, to provide basis for optimizing the imaging contrast at 0.1 T. 68 healthy volunteers were included. On-resonance spin lock relaxation time (T) and off-resonance spin lock relaxation parameters (Toff, Me/Mo), MT parameters (T1sat, Ms/Mo), and T1, T2 were determined for the cortical gray matter, and for the frontal and parietal white matters. The T for the frontal and parietal white matters ranged from 110 to 133 ms and from 122 to 155 ms with locking field strengths from 50 μT to 250 μT, respectively. Accordingly, the values for the gray matter ranged from 127 to 155 ms. With a locking field strength of 50 μT, Toff for the frontal and parietal white matters were from 114 to 217 ms and from 126 to 219 ms, and for the gray matter from 136 to 267 ms with the angle between the effective magnetic field (Beff) and the z-axis (θ) ranging from 60° to 15°, respectively. The T of the white and gray matters increased significantly with increasing locking field amplitude (p < 0.001). The Toff decreased significantly with increasing θ (p < 0.001). T and Toff with θ ≥ 30° were statistically significantly shorter in the frontal than in the parietal white matters (p < 0.05). The duration, amplitude and θ of the locking pulse provide additional parameters to optimize contrast in brain SL imaging.  相似文献   

18.
The principle of the integrative evaluation of absorption line profiles relies on the numeric integration of absorption line signals to retrieve absorber concentrations, e.g., of trace gases. Thus, it is a fast and robust technique. However, previous implementations of the integrative evaluation principle showed shortcomings in terms of accuracy and the lack of a fit quality indicator. This has motivated the development of an advanced integrative (AI) fitting algorithm. The AI fitting algorithm retains the advantages of previous integrative implementations—robustness and speed—and is able to achieve high accuracy by introduction of a novel iterative fitting process. A comparison of the AI fitting algorithm with the widely used Levenberg–Marquardt (LM) fitting algorithm indicates that the AI algorithm has advantages in terms of robustness due to its independence from appropriately chosen start values for the initialization of the fitting process. In addition, the AI fitting algorithm shows speed advantages typically resulting in a factor of three to four shorter computational times on a standard personal computer. The LM algorithm on the other hand retains advantages in terms of a much higher flexibility, as the AI fitting algorithm is restricted to the evaluation of single absorption lines with precomputed line width. Comparing both fitting algorithms for the specific application of in situ laser hygrometry at 1,370 nm using direct tunable diode laser absorption spectroscopy (TDLAS) suggests that the accuracy of the AI algorithm is equivalent to that of the LM algorithm. For example, a signal-to-noise ratio of 80 and better typically yields a deviation of <1 % between both fitting algorithms. The properties of the AI fitting algorithm make it an interesting alternative if robustness and speed are crucial in an application and if the restriction to a single absorption line is possible. These conditions are fulfilled for the 1,370 nm TDLAS hygrometry at the aerosol and cloud chamber aerosol interactions and dynamics in the atmosphere (AIDA)—a unique large-scale facility to study atmospheric processes. The robustness of the AI fitting algorithm has been validated for typical AIDA conditions encompassing strong transmission fluctuations during the formation of droplet or ice clouds inside AIDA. Under these conditions, the stability of the AI algorithm remained virtually unaffected. Thus, the AI algorithm presents an alternative technique for a fast, reliable, and accurate online data evaluation of the humidity measurements at AIDA.  相似文献   

19.
Proton nuclear magnetic resonance relaxation times, T1 and T2, of water in unfixed gray and white matter from normal and edematous rabbit brain tissues were measured in vitro at 23°C and 100 MHz to evaluate the effects of the temperature (?25°C to 37°C) and duration (0 to 96 h) of tissue storage on relaxation times. T1 and T2 tended to decrease during storage, probably from slow dehydration of the tissue. This effect was greatest in tissues stored at 37°C and least in those stored at 4 and ?25°C; decreases in T1 and T2 were greater in white matter than in gray matter. Freezing brain tissue to ?25°C caused a sudden decrease in the T2 of normal white matter. Relaxation times were constant for 5 h in tissues stored at 23°C and for 40 h at 4°C. These results correlated well with corresponding tissue water loss.  相似文献   

20.
PurposeTo investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT).MethodsA total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR TT. The age range was 4–81 years with a median of 32 years (interquartile range, 15 to 56 years).ResultsAnalysis time per patient was < 5 min. The peak longitudinal strain (Ell) was − 22.11 ± 3.51%. The peak circumferential strains (Ecc) for global, basal, mid-cavity and apical segments were as follows: − 11.69 ± 2.25%, − 11.00 ± 2.45%, − 11.17 ± 3.36%, − 12.90 ± 3.34%. There were significant gender differences in peak Ecc at the base (P = 0.04) and the mid-cavity (P = 0.03) with greater deformation in females than in males. On Bland-Altman analysis, peak Ell (mean bias, 0.22 ± 1.67; 95% CI − 3.05 to 3.49) and mid-cavity Ecc (mean bias, 0.036 ± 1.75; 95% CI, − 3.39 to 3.47) had the best intra-observer agreement and inter-observer agreement, respectively.ConclusionsRV longitudinal and circumferential strains can be quickly assessed with good intra-observer and inter-observer variability using TT.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号