首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 476 毫秒
1.
This prospective multi-center study aimed to evaluate the inter-vendor and test-retest reliabilities of resting-state functional magnetic resonance imaging (RS-fMRI) by assessing the temporal signal-to-noise ratio (tSNR) and functional connectivity. Study included 10 healthy subjects and each subject was scanned using three 3 T MR scanners (GE Signa HDxt, Siemens Skyra, and Philips Achieva) in two sessions. The tSNR was calculated from the time course data. Inter-vendor and test-retest reliabilities were assessed with intra-class correlation coefficients (ICCs) derived from variant component analysis. Independent component analysis was performed to identify the connectivity of the default-mode network (DMN). In result, the tSNR for the DMN was not significantly different among the GE, Philips, and Siemens scanners (P = 0.638). In terms of vendor differences, the inter-vendor reliability was good (ICC = 0.774). Regarding the test-retest reliability, the GE scanner showed excellent correlation (ICC = 0.961), while the Philips (ICC = 0.671) and Siemens (ICC = 0.726) scanners showed relatively good correlation. The DMN pattern of the subjects between the two sessions for each scanner and between three scanners showed the identical patterns of functional connectivity. The inter-vendor and test-retest reliabilities of RS-fMRI using different 3 T MR scanners are good. Thus, we suggest that RS-fMRI could be used in multicenter imaging studies as a reliable imaging marker.  相似文献   

2.
Passband balanced steady state free precession (b-SSFP) fMRI employs the flat portion of the SSFP off-resonance response to obtain microscopic susceptibility changes elicited by changes in blood oxygenation following enhancement in neuronal activity. This technique can reduce geometric distortion and signal dropout while maintaining rapid acquisition and high signal-to-noise ratio (SNR) compared with traditional fMRI techniques. In the study, we developed a novel multi-phase passband b-SSFP fMRI technique that can achieve a spatial resolution of a few mm3 and a high temporal sampling rate of 50 ms per slice at 7 Tesla. This technique was further applied for an event-related (ER) fMRI paradigm. As a comparison, gradient-echo echo-planar imaging (GE-EPI) with similar spatial resolution and temporal sampling rate was carried out for the same ER-fMRI experiment. Experiments with visual cortex stimulation were carried out at 7 Tesla to demonstrate whether the multi-phase b-SSFP technique and GE-EPI are able to differentiate temporal delays in hemodynamic response function (HRF) separated by 100 ms in stimulus onset. Consistent with ERP results, the upslope of the HRF of both techniques can differentiate 100 ms delay in stimulus onset, with the former showing a lower level of intersubject variability. The present study demonstrated that the multi-phase passband b-SSFP fMRI technique can be applied for resolving neuronal events on the order of 100 ms at ultrahigh magnetic fields.  相似文献   

3.
The increased signal-to-noise ratio (SNR) offered by functional Magnetic Resonance Imaging (fMRI) at 7T allows the acquisition of functional data at sub-millimetric spatial resolutions. However, simply reducing partial volume effects is not sufficient to precisely localize task-induced activation due to the indirect mechanisms that relate brain function and the changes in the measured signal.In this work T2* and T2 weighted Echo Planar Imaging (EPI) schemes based on Gradient Recalled Echo (GRE) and Spin Echo (SE) were evaluated in terms of temporal SNR, percent signal change, contrast to noise ratio (CNR), activation volume, and sensitivity and specificity to gray matter. Datasets were acquired during visual stimulation at in-plane resolutions ranging between 1.5 × 1.5 mm2 and 0.75 × 0.75 mm2 targeting the early visual cortex.While similar activation foci were obtained in all acquisitions, at in-plane resolutions of 1.0 × 1.0 mm2 and larger voxel sizes the T2 weighted contrast of SE-EPI allowed the identification of the activation site with better spatial accuracy. However, at sub-millimetric resolutions the decrease in temporal SNR significantly hampered the sensitivity and the extent of the activation site. On the other hand, high resolution T2* weighted data collected with GRE-EPI provided higher CNR and sensitivity, benefiting from the decreased physiological and partial volume effects. However, spurious activations originating from regions of blood drainage were still present in GRE data, and simple thresholding techniques were found to be inadequate for the removal of such contributions. The combination of 2-class and 3-class automated segmentations, performed directly in EPI space, allowed the selection of active voxels in gray matter. This approach could enable GRE-EPI to accurately map functional activity with satisfactory CNR and specificity to the true site of activation.  相似文献   

4.
PurposeTo investigate magnetic resonance neurography (MRN) of the lumbosacral plexus (LSP) with cerebrospinal fluid (CSF) suppression by using submillimeter resolution for three-dimensional (3D) turbo spin echo (TSE) imaging.Materials and methodsUsing extended phase graph (EPG) analysis, the signal response of CSF was simulated considering dephasing from coherent motion for frequency-encoding voxel sizes ranging from 0.3 to 1.3 mm and for CSF velocities ranging from 0 to 4 cm/s. In-vivo MRN included 3D TSE data with frequency encoding parallel to the feet/head axis from 15 healthy adults (mean age: 28.5 ± 3.8 years, 5 females; acquisition voxel size: 2 × 2 × 2 mm3) and 16 pediatric patients (mean age: 6.7 ± 4.1 years, 7 females; acquisition voxel size: 0.7 × 0.7 × 1.4 mm3) acquired at 3 Tesla. Five of the adults were scanned repetitively with changing acquisition voxel sizes (1 × 2 × 2 mm3, 0.7 × 2× 2 mm3, and 0.5 × 2 × 2 mm3). Measurements of the bilateral ganglion of the L5 nerve root, averaged between sides, as well as the CSF in the thecal sac were obtained for all included subjects and compared between adults and pediatric patients and between voxel sizes, using a CSF-to-nerve signal ratio (CSFNR).ResultsAccording to simulations, the CSF signal is reduced along the echo train for moving spins. Specifically, it can be reduced by over 90% compared to the maximum simulated signal for flow velocities above 2 cm/s, and could be most effectively suppressed by considering a frequency-encoding voxel size of 0.8 mm or less. For in-vivo measurements, mean CSFNR was 1.52 ± 0.22 for adults and 0.10 ± 0.03 for pediatric patients (p < .0001). Differences in CSFNR were significant between measurements using a voxel size of 2 × 2 × 2 mm3 and measurements in data with reduced voxel sizes (p ≤ .0012), with submillimeter resolution (particularly 0.5 × 2 × 2 mm3) providing highest CSF suppression.ConclusionsApplying frequency-encoding voxel sizes in submillimeter range for 3D TSE imaging with frequency encoding parallel to the feet/head axis may considerably improve MRN of LSP pathology in adults in the future because of favorable CSF suppression.  相似文献   

5.
The elemental composition of discrete powdered sediment samples can be measured by the energy‐dispersive X‐ray fluorescence (XRF) system that is installed in XRF core scanners. Because an appropriate sample carrier for powdered samples is currently not available, for example, for the ITRAX XRF core scanner, such a carrier is presented in this technical note. The designed sample carrier can hold 30 sample cups with a volume of 0.88 cm3 each. A maximum of 5 sample carriers, that is, 150 samples, can be measured in one run. The sample cups and carriers are optimized for a measurement procedure with a step size of 5 mm and variable count times up to 100 s per sample. With this setting, data are collected from an area of 100 mm2 in the center of the sample thereby ensuring a good representativeness of the signal because potential sample inhomogeneity is accounted for. Because the described sample carrier system allows rapid element analyses of discrete powdered environmental samples with an XRF core scanner, it may in some cases represent a time‐ and cost‐efficient alternative to conventional XRF analyses.  相似文献   

6.
Broad flat field laser scanning is critical to the success of laser material processing, used in techniques such as rapid prototyping & manufacturing (RP&M) and micro-machining. For these techniques it is necessary to produce high-performance optical systems that can fulfill the need for a smaller focused spot size over broad, flat field scanning areas. This paper concentrates on the issues of defocus error compensation. A dynamic focusing system is designed, intended primarily for broad flat field galvanometric laser scanning applications. Key technologies are described in detail; corresponding solutions have been used to design and produce a CO2 infrared optical focusing system, which is capable of scanning a focused spot size of 120 μm or less over areas up to 500 mm2.  相似文献   

7.
PurposeTo compare three anisotropic acquisition schemes and three compressed sensing (CS) approaches for accelerated tissue sodium concentration (TSC) quantification using 23Na MRI at 7 T.Materials and methodsThree anisotropic 3D-radial acquisition sequences were evaluated using simulations, phantom- and in vivo TSC measurements: An anisotropic density-adapted 3D-radial sequence (3DPR-C), a 3D acquisition-weighted density-adapted stack-of-stars sampling scheme (SOS) and a SOS approach with golden-ratio rotation (SOS-GR). Eight healthy volunteers were examined at a 7 Tesla MRI system. TSC measurements of the calf were conducted with a nominal spatial resolution of Δx = (3.0 × 3.0 × 15.0) mm3 and a field of view of (156.0 × 156.0 × 240.0) mm3 for multiple undersampling factors (USF). Three CS reconstructions were evaluated: Total variation CS (TV-CS), 3D dictionary-learning compressed sensing (3D-DLCS) and TV-CS with a block matching prior (TV-BL-CS). Results of the simulations and measurements were compared to a simulated ground truth (GT) or a fully sampled reference measurement (FS), respectively. The deviation of the mean TSC evaluated in multiple ROI (mEGT/FS) and the normalized root-mean-squared error (NRMSE) for simulations were evaluated for CS and NUFFT reconstructions.ResultsIn simulations, the SOS-GR yielded the lowest NRMSE and mEGT (< 4%) with NUFFT for an acquisition time (TA) of less than 2 min. CS further improved the results. In simulations and measurements, the best TSC quantification results were obtained with 3D-DLCS and SOS-GR (lowest NRMSE, mEGT < 2.6% in simulations, mEGT < 10.7% for phantom measurements and mEFS < 6% in vivo) with an USF = 4.1 (TA < 2 min). TV-CS showed no or only slight improvements to NUFFT. The results of TV-BL-CS were similar to 3D-DLCS.DiscussionThe TA for TSC measurements could be reduced to less than 2 min by using adapted sequences such as SOS-GR and CS reconstruction approaches such as 3D-DLCS or TV-BL-CS, while the quantitative accuracy stays comparable to a fully sampled NUFFT reconstruction (approx. 8 min TA). In future, the lower TA could improve clinical applicability of TSC measurements.  相似文献   

8.
Sensitivity Encoding (SENSE) is a widely used technique in Parallel Magnetic Resonance Imaging (MRI) to reduce scan time. Reconfigurable hardware based architecture for SENSE can potentially provide image reconstruction with much less computation time. Application specific hardware platform for SENSE may dramatically increase the power efficiency of the system and can decrease the execution time to obtain MR images. A new implementation of SENSE on Field Programmable Gate Array (FPGA) is presented in this study, which provides real-time SENSE reconstruction right on the receiver coil data acquisition system with no need to transfer the raw data to the MRI server, thereby minimizing the transmission noise and memory usage. The proposed SENSE architecture can reconstruct MR images using receiver coil sensitivity maps obtained using pre-scan and eigenvector (E-maps) methods. The results show that the proposed system consumes remarkably less computation time for SENSE reconstruction, i.e., 0.164 ms @ 200 MHz, while maintaining the quality of the reconstructed images with good mean SNR (29 + dB), less RMSE (< 5 × 10 2) and comparable artefact power (< 9 × 10 4) to conventional SENSE reconstruction. A comparison of the center line profiles of the reconstructed and reference images also indicates a good quality of the reconstructed images. Furthermore, the results indicate that the proposed architectural design can prove to be a significant tool for SENSE reconstruction in modern MRI scanners and its low power consumption feature can be remarkable for portable MRI scanners.  相似文献   

9.
PurposeTo develop a fast volumetric T1 mapping technique.Materials and methodsA stack-of-stars (SOS) Look Locker technique based on the acquisition of undersampled radial data (>30× relative to Nyquist) and an efficient multi-slab excitation scheme is presented. A principal-component based reconstruction is used to reconstruct T1 maps. Computer simulations were performed to determine the best choice of partitions per slab and degree of undersampling. The technique was validated in phantoms against reference T1 values measured with a 2D Cartesian inversion-recovery spin-echo technique. The SOS Look Locker technique was tested in brain (n = 4) and prostate (n = 5). Brain T1 mapping was carried out with and without kz acceleration and results between the two approaches were compared. Prostate T1 mapping was compared to standard techniques. A reproducibility study was conducted in brain and prostate. Statistical analyses were performed using linear regression and Bland Altman analysis.ResultsPhantom T1 values showed excellent correlations between SOS Look Locker and the inversion-recovery spin-echo reference (r2 = 0.9965; p < 0.0001) and between SOS Look Locker with slab-selective and non-slab selective inversion pulses (r2 = 0.9999; p < 0.0001). In vivo results showed that full brain T1 mapping (1 mm3) with kz acceleration is achieved in 4 min 21 s. Full prostate T1 mapping (0.9 × 0.9 × 4 mm3) is achieved in 2 min 43 s. T1 values for brain and prostate were in agreement with literature values. A reproducibility study showed coefficients of variation in the range of 0.18–0.2% (brain) and 0.15–0.18% (prostate).ConclusionA rapid volumetric T1 mapping technique was developed. The technique enables high-resolution T1 mapping with adequate anatomical coverage in a clinically acceptable time.  相似文献   

10.
The blood oxygen level-dependent (BOLD) effect is extensively used for functional MRI (fMRI) but presents some limitations. Diffusion-weighted fMRI (DfMRI) has been proposed as a method more tightly linked to neuronal activity. This work proposes a protocol of DfMRI acquired for several b-values and diffusion directions that is compared to gradient-echo BOLD (GE-BOLD) and to repeated spin-echo BOLD (SE-BOLD, acquisitions performed with b = 0 s/mm2), which was also used to ensure the reproducibility of the response.A block stimulation paradigm of the primary visual system (V1) was performed in 12 healthy subjects with checkerboard alternations (2 Hz frequency). DfMRI was performed at 3 T with 5 b-values (b = 1500, 1000, 500, 250, 0 s/mm2) with TR/TE = 1004/93 ms, Δ/δ = 45.4 ms/30 ms, and 6 spatial directions for diffusion measures. GE-BOLD was performed with a similar block stimulation design timing. Apparent Diffusion Coefficient (ADC)-fMRI was computed with all b-values used. An identical Z-score level was used for all fMRI modalities for the comparison of volumes of activation. ADC-fMRI and SE-BOLD fMRI activation locations were compared in a voxel-based analysis to a cytoarchitectural probability map of V1.SE-BOLD activation volumes represented only 55% of the GE-BOLD activation volumes (P < 0.0001). DfMRI activation volumes averaged for all b-values acquired represented only 12% of GE-BOLD (P < 0.0001) and only 22% of SE-BOLD activation volumes (P < 0.005). Compared to SE-BOLD-fMRI, ADC-fMRI activations showed fewer pixels outside of V1 and a higher average probability of belonging to V1.DfMRI and ADC-fMRI acquisition at 3 T could be easily post-processed with common neuro-imaging software. DfMRI and ADC-fMRI activation volumes were significantly smaller than those obtained with SE-BOLD. ADC-fMRI activations were more precisely localized in V1 than those of SE-BOLD-fMRI. This validated the increased capability of ADC-fMRI compared to BOLD to enhance the precision of localizing an fMRI activation in the cyto-architectural zone V1, thereby justifying the use of ADC-fMRI for neuro-scientific studies.  相似文献   

11.
ObjectivesLiver vessel density can be evaluated by DDVD (diffusion derived vessel density): DDVD(b0b1) = Sb0/ROIarea0 – Sb1/ROIarea1, where Sb0 and Sb1 refer to the liver signal when b is 0 or 1 s/mm2. Sb1 and ROIarea1 may be replaced by other b-values. With a rat biliary duct ligation (BDL) model, this study assesses the usefulness of liver DDVD computed from a simplified IVIM imaging protocol using b = 25 and b = 50 to replace b = 1 s/mm2, alone and in combination with other IVIM parameters.MethodsMale Sprague-Dawley rats were used. The rat number was 5, 5, 5, and 3 respectively, for the timepoints of 7, 14, 21, 28 days post-BDL surgery. 12 rats had partial biliary duct recanalization performed after the rats had BDL for 7 days and then again followed-up for a mean of 14 days. Liver diffusion MRIs were acquired at 3.0 T with a b-value distribution of 0, 25, 50, 75, 100, 150, 300, 700, 1000 s/mm2. DDVDmean (control rats n = 6) was the mean of DDVD(b0b25) and DDVD(b0b50). IVIM fitting started from b = 0 s/mm2 with segmented fitting and a threshold b of 50 s/mm2 (n = 5 for control rats). Three 3-D spaces were constructed using a combination of the four diffusion parameters.ResultsThe control rats and BDL rats (n = 18) had a liver DDVDmean of 84.0 ± 26.2 and 44.7 ± 14.4 au/pixel (p < 0.001). All 3-D spaces totally separated healthy livers and all fibrotic livers (n = 30, BDL rats and recanalization rats). The mean relative distance between healthy liver cluster and fibrotic liver cluster was 0.331 for PF, Dslow, and Dfast; 0.381 for PF, Dfast, and DDVDmean; and 0.384 for PF, Dslow, and DDVDmean.ConclusionA combination of PF, Dslow, and Dfast allows total separation of healthy livers and fibrotic livers and the integration of DDVD improved the separation.  相似文献   

12.
BackgroundAchieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors.PurposeMagnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors.Study typeProspective observational study.SubjectsA spherical isotropic diffusion phantom, and a single human control volunteer.Field strength/sequence3 T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm2 with 12, 32, and 384 diffusion gradient directions per shell.AssessmentWe compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware.Statistical testsWilcoxon rank-sum test between uncorrected and corrected data.ResultsIn phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p < 0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p < 0.05).ConclusionOur method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.  相似文献   

13.
A mini-thermometer based on the 35Cl nuclear quadrupole resonance (NQR) frequency temperature dependence in the chlorates KClO3 and NaClO3 was built and successfully tested by measuring temperature and temperature gradient at 77 K and higher in about 100 mm3 active volume of a mini Joule–Thomson refrigerator. In the design of the tank-circuit coil, an array of small coils connected in series enabled us (a) to achieve a suitable ratio of inductance to capacity in the NQR spectrometer input tank circuit, (b) to use a single crystal of KClO3 or NaClO3 (of 1–2 mm3 size) in one coil as a mini-thermometer with a resolution of 0.03 K and (c) to construct a system for measuring temperature gradients when the spatial coordinates of each chlorate single crystal within an individual coil are known.  相似文献   

14.
Diffusion weighted magnetic resonance imaging (DWI) has been mostly acquired using single-shot echo-planar imaging (ss EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in ss EPI especially for abdominal imaging, even with the advances in parallel imaging. A novel method of reduced Field of View ss EPI (rFOV ss EPI) has achieved high resolution DWI in human carotid artery, spinal cord with reduced blurring and higher spatial resolution than conventional ss EPI, but it has not been used to pancreas imaging. In the work, comparisons between the full FOV ss-DW EPI and rFOV ss-DW EPI in image qualities and ADC values of pancreatic tumors and normal pancreatic tissues were performed to demonstrate the feasibility of pancreatic high resolution rFOV DWI. There were no significant differences in the mean ADC values between full FOV DWI and rFOV DWI for the 17 subjects using b = 600 s/mm2 (P = 0.962). However, subjective scores of image quality was significantly higher at rFOV ss DWI (P = 0.008 and 0.000 for b-value = 0 s/mm2 and 600 s/mm2 respectively). The spatial resolution of DWI for pancreas was increased by a factor of over 2.0 (from almost 3.0 mm/pixel to 1.25 mm/pixel) using rFOV ss EPI technique. Reduced FOV ss EPI can provide good DW images and is promising to benefit applications for pancreatic diseases.  相似文献   

15.
PurposeThe aim of this work is to implement real-time 3D MR thermometry for high intensity focused ultrasound (HIFU) monitoring.MethodsVolumetric MR thermometry was implemented based on a 3D echo-shifted sequence with short TR to improve temperature sensitivity. The 3D acquisition was accelerated in two phase encoding directions with controlled aliasing in volumetric parallel imaging (CAIPIRINHA). Image reconstruction was run in an open source reconstruction platform (Gadgetron).ResultsPhantom experiments showed the proposed volumetric thermometry was comparable to the fiber optical thermometer. In-vivo animal experiments in rabbit thigh showed that the temperature error before and after 4× acceleration was less than 0.65 °C. Finally, real-time 3D thermometry with temporal resolution ~3 s and spatial resolution 2 × 2 × 5 mm3 (spatial coverage 192 × 192 × 80 mm3) was achieved with Gadgetron reconstruction.ConclusionReal-time temperature monitoring was achieved in-vivo by using parallel imaging accelerated 3D echo-shifted sequence with Gadgetron reconstruction.  相似文献   

16.
We report device linearity improvement and current enhancement in both a heterostructure FET (HFET) and a camel-gate FET (CAMFET) using InGaAs/GaAs high-low and GaAs high-medium-low doped channels, respectively. In an HFET, a low doped GaAs layer was employed to build an excellent Schottky contact. In a GaAs CAMFET, a low doped layer together withn+andp+layers formed a high-performance majority camel-diode gate. Both exhibit high effective potential barriers of >1.0 V and gate-to-drain breakdown voltages of >20.0 V (atIg=1.0 mA mm−1). A thin, high doped channel was used to enhance current drivability and to improve the transconductance linearity. A 2×100 μm2HFET had a peak transconductance of 230 mS mm−1and a current density greater than 800 mA mm−1. The device had a transconductance of more than 80 percent of the peak value over a wide drain current range of 200 to 800 mA mm−1. A 1.5×100 μm2CAMFET had a peak transconductance of 220 mS mm−1and a current density greater than 800 mA mm−1. Similarly, the device had a transconductance of more than 80 percent of the peak value over a wide drain current range of 160 to 800 mA mm−1. The improvement of device linearity and the enhancement of current density suggest that high-to-low doped-channel devices for both an HFET and a CAMFET are suitable for high-power large signal circuit applications.  相似文献   

17.
PurposeThe aim of this work is to test the use of aqueous solutions of Ficoll®**, a highly branched polymer displaying crowding properties, to build a phantom suitable for Diffusion Weighted Imaging (DWI) in Magnetic Resonance Imaging (MRI).MethodsWe developed a test object made of a cylindrical plastic container with a precise geometrical arrangement suitable for measuring several samples at the same time. The container was designed to host single vials with variable geometry and number, and to fit inside common commercial head coils for MRI scanners.In our experiments, vials were filled with 8 aqueous solutions of Ficoll 70 and Ficoll 400 spanning a range of polymer concentration from 5 to 30% by weight. Vials containing ultra-pure water were also used as reference. Experiments were performed on both 1.5 and 3 T clinical scanners (GE, Philips and Siemens), under the conditions of a standard clinical examination.ResultsThe geometry of the phantom provided reduced imaging artifacts, especially image distortions at magnetic interfaces. We found that the Apparent Diffusion Coefficient (ADC) varied in the range of 0.00125–0.00223 mm2/s and decreased with Ficoll concentration. ADC vs Ficoll concentration exhibited a linear trend. Results were consistent over time and among different MRI clinical scanners, showing an average variability of 3% at 1.5 T and of 7.5% at 3 T. Moreover, no substantial difference was found between Ficoll 70 and 400. By varying Ficoll concentration, ADC can be modulated to approach tissue-mimicking values. Preliminary results for relaxation measurements proved that both T1 and T2 decreased with Ficoll concentration in the ranges 1.3–2.4 s and 150–800 ms respectively.ConclusionsIn this work, we propose a 3D phantom design based on the widespread crowding agent Ficoll, which is suitable for DWI quality assurance purposes in MRI acquisitions. Aqueous Ficoll solutions provide good performance in terms of stability, ease of preparation, and safety.  相似文献   

18.
We report on the efficient room-temperature operation of 4F3/24I9/2 transition in a diode pumped Nd:YAG laser operating at 946 nm. An output power of 5.1 W and a slope efficiency of 23.6% at 946 nm have been obtained. Different LBO crystals of length 3×3×10 mm3, 3×3×15 mm3, 3×3×18 mm3 were selected as frequency doubling material for comparison. A maximum single-ended output power of 1.3 W at 473 nm was achieved by frequency doubling with an optical conversion efficiency of 5%. When the Nd:YAG rod was replaced by the one with high reflectivity coating at 473 nm on the pump side, the output power of blue light was almost twice that without high reflectivity coating for 473 nm at the same pump power level. Moreover, the theoretical optimum length of LBO crystal for intracavity frequency doubling was discussed, and the experimental results made a good agreement with it.  相似文献   

19.
This work was to study the contact interface between a set of used hand taps and another new one based on the regional scanning of ultrasound. The contact image was a novel disclosure for hand taps contact. The objective of this work was to provide a wear diagnosis by making a comparison of contact area between the used and the new hand taps. The 2D maps showed an apparent change not only in area sizes but also in contact shapes between the used and the new hand taps. The 3D contact images also provided useful information to show the degree of contact.The contact area between the tap and the workpiece was calculated using an image analysis software package. The range of contact areas varied from 2.49 mm2 to 35.31 mm2 for the used hand taps and from 1.19 mm2 to 28.55 mm2 for the new taps, depending on the definition of the contrast ratio. The result provided another scientific data for users to decide a correct timing for the tool replacement. In addition, maps of reflection coefficient and pressure contour distribution were presented. The range of contact pressure varied from 2.5 Mpa to 4.2 Mpa.  相似文献   

20.
Femtosecond X-ray science is a new frontier in ultrafast research in which time-resolved measurement techniques are applied with X-ray pulses to investigate structural dynamics at the atomic scale on the fundamental time scale of an atomic vibrational period (∼100 fs). This new research area depends critically on the development of suitable femtosecond X-ray sources with the appropriate flux (ph/(s·0.1% BW)), brightness (ph/(s·mm2·mrad2·0.1% BW)), and tunability for demanding optical/X-ray pump probe experiments. In this paper we review recently demonstrated techniques for generating femtosecond X-rays via interaction between femtosecond laser pulses and relativistic electron beams. We give an overview of a novel femtosecond X-ray source that is proposed based on a linear accelerator combined with X-ray pulse compression.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号