1.
PurposeTo determine if tumor stiffness by MR Elastography (MRE) is associated with hepatocellular carcinoma (HCC) pathologic features.Material and methodsA retrospective review was undertaken of all patients with pathologically confirmed HCC who underwent MRE prior to loco-regional therapy, surgical resection or transplant between 1/1/2007 to 12/31/2015. An independent observer measured tumor stiffness (kilopascals, kPa) by drawing regions of interest (ROI) covering the HCC and in the case of HCCs with non-enhancing/necrotic components, only the solid portion was included in the ROI. HCC tumor grade (WHO criteria), vascular invasion and tumor encapsulation were assessed from retrievable pathology specimens by an expert hepatobiliary pathologist. Tumor stiffness was compared by tumor grade, size, presence of capsule and vascular invasion using Student's t-test (or Exact Mann-Whitney test).Results21 patients were identified who had pathologically confirmed HCCs and tumor MRE data. 17 patients (81.0%) had underlying chronic liver disease. The mean ± SD tumor size (cm) was 5.3 ± 3.9 cm. The mean ± SD tumor stiffness was 5.9 ± 1.4 kPa. Tumors were graded as well differentiated (N = 2), moderately differentiated (N = 11) and poorly differentiated (N = 8). There was a trend toward increased tumor stiffness in well/moderately differentiated HCCs (6.5 ± 1.2 kPa; N = 13) compared to poorly differentiated HCCs (4.9 ± 1.2 kPa; N = 8) (p < 0.01). There was no significant correlation between tumor stiffness and liver stiffness or tumor size. There was no significant difference in tumor stiffness by presence or etiology of chronic liver disease, vascular invasion or tumor encapsulation.ConclusionPreliminary data suggest that tumor stiffness by MRE may be able to differentiate HCC tumor grade.  相似文献   

2.
Magnetic resonance elastography (MRE) and ultrasound shear wave elastography (SWE) are imaging techniques to measure stiffness of the soft tissue using magnetic resonance imaging (MRI) and ultrasound images, respectively. The purpose of this study was to explore the feasibility of the MRE measurement to evaluate the change in supraspinatus (SSP) muscle stiffness before and after rotator cuff tear, and to compare the result with those of SWE. Six swine shoulders were used. The skin and subcutaneous fat were removed, and the stiffness value of the SSP muscle was measured by MRE and SWE. The MRE measurement was performed with 0.3 T open MRI and the vibration from a pneumatic driver system with active driver to a passive driver to create the shear wave in the tissue. The passive driver was placed on the center of the SSP muscle. The stiffness was estimated from the wave images using local frequency estimation methods. In the SWE measurement, the probe of the ultrasound was placed on the center of the SSP muscle. The shear wave propagation speed was measured at a depth of 1 cm from the surface, and the stiffness was calculated. After those measurements, the rotator cuff tendon was detached from the greater tuberosity, and MRE and SWE measurements were then performed in the same manner again. The differences in the stiffness values were compared between before and after the rotator cuff tendon tear on both the MRE and SWE measurements. The results indicated that stiffness values on MRE and SWE were 9.3 ± 1.8 and 10.0 ± 1.2 kPa respectively before the rotator cuff tear, and 7.3 ± 1.3 and 8.0 ± 0.8 kPa respectively after the tendon detachment. Stiffness values were significantly lower after the tendon detachment on both the MRE and SWE measurements (p < 0.05). Our results demonstrated that stiffness values of the SSP muscle on MRE and SWE were lower after rotator cuff detachment. From this result, MRE may be a feasible method for quantification of the change in rotator cuff muscle stiffness.  相似文献   

3.
In magnetic resonance elastography (MRE), shear waves at a certain frequency are encoded through bipolar gradients that switch polarity at a controlled encoding frequency and are offset in time to capture wave propagation using a controlled sampling frequency. In brain MRE, there is a possibility that the mechanical actuation frequency is different from the vibration frequency, leading to a mismatch with encoding and sampling frequencies. This mismatch can occur in brain MRE from causes both extrinsic and intrinsic to the brain, such as scanner bed vibrations or active damping in the head. The purpose of this work was to investigate how frequency mismatch can affect MRE shear stiffness measurements. Experiments were performed on a dual-medium agarose gel phantom, and the results were compared with numerical simulations to quantify these effects. It is known that off-frequency encoding alone results in a scaling of wave amplitude, and it is shown here that off-frequency sampling can result in two main effects: (1) errors in the overall shear stiffness estimate of the material on the global scale and (2) local variations appearing as stiffer and softer structures in the material. For small differences in frequency, it was found that measured global stiffness of the brain could theoretically vary by up to 12.5% relative to actual stiffness with local variations of up to 3.7% of the mean stiffness. It was demonstrated that performing MRE experiments at a frequency other than that of tissue vibration can lead to artifacts in the MRE stiffness images, and this mismatch could explain some of the large-scale scatter of stiffness data or lack of repeatability reported in the brain MRE literature.  相似文献   

4.
Low back pain (LBP) is a costly and widely prevalent health disorder in the U.S. One of the most common causes of LBP is degenerative disc disease (DDD). There are many imaging techniques to characterize disc degeneration; however, there is no way to directly assess the material properties of the intervertebral disc (IVD) within the intact spine. Magnetic resonance elastography (MRE) is an MRI-based technique for non-invasively mapping the mechanical properties of tissues in vivo. The purpose of this study was to investigate the feasibility of using MRE to detect shear wave propagation in and determine the shear stiffness of an axial cross-section of an ex vivo baboon IVD, and compare with shear displacements from a finite element model of an IVD motion segment in response to harmonic shear vibration. MRE was performed on two baboon lumbar spine motion segments (L3–L4) with the posterior elements removed at a range of frequencies (1000–1500 Hz) using a standard clinical 1.5 T MR scanner. Propagating waves were visualized in an axial cross-section of the baboon IVDs in all three motion-encoding directions, which resembled wave patterns predicted using finite element modeling. The baboon nucleus pulposus showed an average shear stiffness of 79 ± 15 kPa at 1000 Hz. These results suggest that MRE is capable of visualizing shear wave propagation in the IVD, assessing the stiffness of the nucleus of the IVD, and can differentiate the nucleus and annulus regions.  相似文献   

5.
PurposeTo determine if parasagittal gastric cine magnetic resonance imaging (MRI) is able to measure gastric oscillatory contractions around 0.05 Hz and to determine its relationship with electrical activity as measured by electrogastrography (EGG).MethodsAssessment of the gastric motility is important for the research of the enteric nervous system and for the diagnosis of functional gastric disorders. Electrogastrography is a non-invasive method that can measure gastric oscillatory electrical activity around 0.05 Hz (slow wave) using electrodes on the abdominal skin, but its sensitivity and specificity of the slow wave detection is limited. We used parasagittal gastric cine MRI around the angular incisure to measure gastric oscillatory contraction around 0.05 Hz in 24 healthy volunteers. Cine MRI was acquired with time resolution of 1 s for 10 min while freely breathing participants were lying on the bed. The gastric area of the cross section was measured for each MR image and assessed its change over time. The results were compared with those for simultaneously recorded EGG.ResultsThe main frequency of the gastric area change for each participant ranged from 0.041 to 0.059 Hz (mean ± S.D. = 0.049 ± 0.004), which corresponds to the gastric slow wave frequency (mean ± S.D. = 0.049 ± 0.004) as measured by EGG (p = 7.9585 × 10 −8, Kendall ‘s tau test). Cross correlation analysis showed that 22 of 24 participants’ gastric area changes were significantly (p < 0.05) related to the EGG waveforms. Displacement of the stomach due to respiration did not affect gastric area measurements.ConclusionsParasagittal cine MRI is correlated with EGG recordings and able to detect and quantifying gastric motility abnormalities.  相似文献   

6.
The purpose of this study was to evaluate the effect of gadoxetic acid (Gd-EOB-DTPA) on measurements of liver stiffness by using magnetic resonance elastography (MRE). In this study, 104 consecutive patients (mean age, 67.7±9.4 years) underwent MRE using a 1.5-T MR scanner equipped with a cylindrical passive driver that was placed across the right chest wall for delivering vibrations. Axial gradient-echo images, which were automatically converted to elastograms that represented stiffness (kPa), were acquired using a continuous sinusoidal vibration of 60 Hz. Two raters independently placed a region of interest on the right lobe of the liver on the elastograms obtained before and after Gd-EOB-DTPA was administered. Liver stiffness was measured using these two elastograms and compared using a paired t test and correlation analysis. No significant difference was observed in liver stiffness before and after Gd-EOB-DTPA was administered (Rater 1, P=.1200; Rater 2, P=.3585). The correlation coefficients were 0.986 (Rater 1) and 0.984 (Rater 2), indicating excellent correlation between the stiffness values before and after Gd-EOB-DTPA was administered. Liver stiffness measured by MRE did not differ before and after Gd-EOB-DTPA was administered.  相似文献   

7.
The vibration of backrests contributes to the discomfort of drivers and passengers. A frequency weighting exists for evaluating the vibration of vertical backrests but not for reclined backrests often used during travel. This experimental study was designed to determine how backrest inclination and the frequency of vibration influence perception thresholds and vibration discomfort when the vibration is applied normal to the back (i.e. fore-and-aft vibration when seated upright and vertical vibration when fully reclined). Twelve subjects experienced the vibration of a backrest (at each of the 11 preferred one-third octave centre frequencies in the range 2.5–25 Hz) at vibration magnitudes from the threshold of perception to 24 dB above threshold. Initially, absolute thresholds for the perception of vibration were determined with four backrest inclinations: 0° (upright), 30°, 60° and 90° (recumbent). The method of magnitude estimation was then used to obtain judgements of vibration discomfort with each of the four backrest angles. Finally, the relative discomfort between the four backrest angles, and the principal locations for feeling vibration discomfort in the body, were determined. With all backrest inclinations, absolute thresholds for the perception of vibration acceleration were dependent on the frequency of vibration. As the backrest inclination became more horizontal, the thresholds increased at frequencies between 4 and 8 Hz. For all backrest inclinations, the rate of growth of discomfort with increasing magnitude of vibration was independent of the frequency of vibration, so the frequency-dependence of discomfort was similar over the range of magnitudes investigated (0.04–0.6 m s?2 rms). With an upright backrest, the discomfort caused by vibration acceleration tended to be greatest at frequencies less than about 8 Hz. With inclined backrests (at 30°, 60°, and 90°), the equivalent comfort contours were broadly similar to each other, with greatest discomfort caused by acceleration around 10 or 12.5 Hz. At frequencies from 4 to 8 Hz, 30–40 percent greater magnitudes of vibration were required with the three inclined backrests to cause discomfort equivalent to that caused by the upright backrest. It is concluded that with an upright backrest the frequency weighting Wc used in current standards is appropriate for predicting the discomfort caused by fore-and-aft backrest vibration. With inclined and horizontal backrests, a weighting similar to frequency weighting Wb (used to predict discomfort caused by vertical seat vibration) appears more appropriate.  相似文献   

8.
Fundamental frequency difference limens (F0DLs) were measured for a target harmonic complex tone with nominal fundamental frequency (F0) of 200 Hz, in the presence and absence of a harmonic masker with overlapping spectrum. The F0 of the masker was 0, ± 3, or ± 6 semitones relative to 200 Hz. The stimuli were bandpass filtered into three regions: 0-1000 Hz (low, L), 1600-2400 Hz (medium, M), and 2800-3600 Hz (high, H), and a background noise was used to mask combination tones and to limit the audibility of components falling on the filter skirts. The components of the target or masker started either in cosine or random phase. Generally, the effect of F0 difference between target and masker was small. For the target alone, F0DLs were larger for random than cosine phase for region H. For the target plus masker, F0DLs were larger when the target had random phase than cosine phase for regions M and H. F0DLs increased with increasing center frequency of the bandpass filter. Modeling using excitation patterns and "summary autocorrelation" and "stabilized auditory image" models suggested that use of temporal fine structure information can account for the small F0DLs obtained when harmonics are barely, if at all, resolved.  相似文献   

9.
PurposeTo determine magnetic resonance elastography (MRE)-derived stiffness of pancreas in healthy volunteers with emphasis on: 1) short term and midterm repeatability; and 2) variance as a function of age.MethodsPancreatic MRE was performed on 22 healthy volunteers (age range:20–64 years) in a 3 T–scanner. For evaluation of reproducibility of stiffness estimates, the scans were repeated per volunteer on the same day (short term) and one month apart (midterm). MRE wave images were analyzed using 3D inversion to estimate the stiffness of overall pancreas and different anatomic regions (i.e., head, neck, body, and tail). Concordance and Spearman correlation tests were performed to determine reproducibility of stiffness measurements and relationship to age.ResultsA strong concordance correlation (ρc = 0.99; p-value < 0.001) was found between short term and midterm repeatability pancreatic stiffness measurements. Additionally, the pancreatic stiffness significantly increased with age with good Spearman correlation coefficient (all ρ > 0.81; p < 0.001). The older age group (> 45 yrs) had significantly higher stiffness compared to the younger group (≤ 45 yrs) (p < 0.001). No significant difference (p > 0.05) in stiffness measurements was observed between different anatomical regions of pancreas, except neck stiffness was slightly lower (p < 0.012) compared to head and overall pancreas at month 1.ConclusionMRE-derived pancreatic stiffness measurements are highly reproducible in the short and midterm and increase linearly with age in healthy volunteers. Further studies are needed to examine these effects in patients with various pancreatic diseases to understand potential clinical applications.  相似文献   

10.
PurposeHepatic magnetic resonance elastography (MRE) is currently a breath-hold imaging technique. Patients with chronic liver disease can have comorbidities that limit their ability to breath-hold (BH) for the required acquisition time. Our aim was to evaluate whether stiffness measurements obtained from a navigator-triggered MRE acquisition are comparable to standard expiratory breath-hold, inspiratory breath-hold or free-breathing in healthy participants.Materials and methodsTwelve healthy participants were imaged using the four methods on a clinical 1.5 T MR system equipped with a product MRE system. Mean liver stiffness, and measurable area of stiffness (with a confidence threshold >95%) were compared between sequences using the concordance correlation coefficient. Repeatability of each sequence between two acquisitions was also assessed.ResultsThe standard BH expiratory technique had high concordance with the navigated technique (r = 0.716), and low concordance with the BH inspiration (r = 0.165) and free-breathing (r = 0.105) techniques. The navigator-triggered technique showed no statistical difference in measurable area of liver or in repeatability compared with the standard expiratory acquisition (p = 0.997 and p = 0.407 respectively). The free-breathing technique produced less measurable liver area and was less repeatable than the alternative techniques. The increase in acquisition time for navigator techniques was 3 min 6 s compared to standard expiratory breath-hold.ConclusionNavigator-based hepatic MRE measurements are comparable to the reference standard expiratory breath-hold acquisition in healthy participants.  相似文献   

11.
This paper proposes a frequency compounding method to reduce speckle interferences, where a concentric annular type high-frequency dual element transducer is used to broaden the bandwidth of an imaging system. In frequency compounding methods, frequency division is carried out to obtain sub-band images containing uncorrelated speckles, which sacrifices axial resolution. Therefore, frequency compounding often deteriorates the target-detecting capability, quantified by the total signal-to-noise ratio (SNR), when the speckle’s SNR (SSNR) is not improved as much as the degraded axial resolution. However, this could be avoided if the effective bandwidth required for frequency compounding is increased. The primary goal of the proposed approach, hence, is to improve SSNR by a factor of two under the condition where axial resolution is degraded by a factor of less than two, which indicates the total SNR improvement to higher than 40% compared to that of an original image. Since the method here employs a dual element transducer operating at 20 and 40 MHz, the effective bandwidth necessary for frequency compounding becomes broadened. By dividing each spectrum of RF samples from both elements into two sub-bands, this method eventually enables four sets of the sub-band samples to contain uncorrelated speckles. This causes the axial resolution to be reduced by a factor of as low as 1.85, which means that this method would improve total SNR by at least 47%. An in vitro experiment on an excised pig eye was performed to validate the proposed approach, and the results showed that the SSNR was improved from 2.081 ± 0.365 in the original image to 4.206 ± 0.635 in the final compounding image.  相似文献   

12.
Liquid perfluorocarbon nanodroplets (NDs) are an attractive alternative to microbubbles (MBs) for ultrasound-mediated therapeutic and diagnostic applications. ND size and size distribution have a strong influence on their behaviour in vivo, including extravasation efficiency, circulation time, and response to ultrasound stimulation. Thus, it is desirable to identify ways to tailor the ND size and size distribution during manufacturing. In this study phospholipid-coated NDs, comprising a perfluoro-n-pentane (PFP) core stabilised by a DSPC/PEG40s (1,2-distearoyl-sn-glycero-3-phosphocholine and polyoxyethylene(40)stearate, 9:1 molar ratio) shell, were produced in phosphate-buffered saline (PBS) by sonication. The effect of the following production-related parameters on ND size was investigated: PFP concentration, power and duration of sonication, and incorporation of a lipophilic fluorescent dye. ND stability was also assessed at both 4 °C and 37 °C. When a sonication pulse of 6 s and 15% duty cycle was employed, increasing the volumetric concentration of PFP from 5% to 15% v/v in PBS resulted in an increase in ND diameter from 215.8 ± 16.8 nm to 408.9 ± 171.2 nm. An increase in the intensity of sonication from 48 to 72 W (with 10% PFP v/v in PBS) led to a decrease in ND size from 354.6 ± 127.2 nm to 315.0 ± 100.5 nm. Increasing the sonication time from 20 s to 40 s (using a pulsed sonication with 30% duty cycle) did not result in a significant change in ND size (in the range 278–314 nm); however, when it was increased to 60 s, the average ND diameter reduced to 249.7 ± 9.7 nm, which also presented a significantly lower standard deviation compared to the other experimental conditions investigated (i.e., 9.7 nm vs. > 49.4 nm). The addition of the fluorescent dye DiI at different molar ratios did not affect the ND size distribution. NDs were stable at 4 °C for up to 6 days and at 37 °C for up to 110 min; however, some evidence of ND-to-MB phase transition was observed after 40 min at 37 °C. Finally, phase transition of NDs into MBs was demonstrated using a tissue-mimicking flow phantom under therapeutic ultrasound exposure conditions (ultrasound frequency: 0.5 MHz, acoustic pressure: 2–4 MPa, and pulse repetition frequency: 100 Hz).  相似文献   

13.
Our purpose is to evaluate bias and repeatability of the quantitative MRI sequences QRAPMASTER, based on steady-state imaging, and variable Flip Angle MRF (MRF-VFA), based on the transient response.Both techniques are assessed with a standardized phantom and five volunteers on 1.5 T and 3 T clinical scanners. All scans were repeated eight times in consecutive weeks.In the phantom, the mean bias±95% confidence interval for T1 values with QRAPMASTER was 10 ± 10% on 1.5 T and 4 ± 13% on 3.0 T. The mean bias for T1 values with MRF-vFA was 21 ± 17% on 1.5 T and 9 ± 9% on 3.0 T. For T2 values the mean bias with QRAPMASTER was 12 ± 3% on 1.5 T and 23 ± 1% on 3.0 T. For T2 values the mean bias with MRF-vFA was 17 ± 1% on 1.5 T and 19 ± 2% on 3.0 T. QRAPMASTER estimated lower T1 and T2 values than MRF-vFA. Repeatability was good with low coefficients of variation (CoV). Mean CoV ± 95% confidence interval for T1 were 3.2 ± 0.4% on 1.5 T and 4.5 ± 0.8% on 3.0 T with QRAPMASTER and 2.7% ± 0.2% on 1.5 T and 2.5 ± 0.2% on 3.0 T with MRF-vFA. For T2 were 3.3 ± 1.9% on 1.5 T and 3.2 ± 0.6% on 3.0 T with QRAPMASTER and 2.0 ± 0.4% on 1.5 T and 5.7 ± 1.0% on 3.0 T with MRF-vFA.The in-vivo T1 and T2 are in the range of values previously reported by other authors.The in-vivo mean CoV ± 95% confidence interval in gray matter were for T1 1.7 ± 0.2% using QRAPMASTER and 0.7 ± 0.5% using MRF-vFA and for T2 were 0.9 ± 0.4% using QRAPMASTER and 2.4 ± 0.5% using MRF-vFA. In white matter were for T1 0.9 ± 0.3% using QRAPMASTER and 1.3 ± 1.1% using MRF-vFA and for T2 were 0.7 ± 0.4% using QRAPMASTER and 2.4 ± 0.4% using MRF-vFA. A GLM analysis showed that the variations in T1 and T2 mainly depend on the field strength and the subject, but not on the follow-up repetition in different days. This confirms the high repeatability of QRAPMASTER and MRF-vFA.In summary, QRAPMASTER and MRF-vFA on both systems were highly repeatable with moderate accuracy, providing results comparable to standard references. While repeatability was similar for both methods, QRAPMASTER was more accurate. QRAPMASTER is a tested commercial product but MRF-vFA is 4.77 times faster, which would ease the inclusion of quantitative relaxometry.  相似文献   

14.
BackgroundChronic liver diseases pose a major health problem worldwide, while common tests for diagnosis and monitoring of diffuse hepatopathy have considerable limitations. Preliminary data on the quantification of hepatic extracellular volume fraction (ECV) with magnetic resonance imaging (MRI) for non-invasive assessment of liver fibrosis are encouraging, with ECV having the potential to overcome several of these constraints.PurposeTo clinically evaluate ECV provided by quantitative MRI for assessing the severity of liver disease.Materials and methodsIn this prospective study, multiparametric liver MRI, including T1 mapping and magnetic resonance elastography (MRE), was performed in subjects with and without hepatopathy between November 2018 and October 2019. T1, T2, T2*, proton density fat fraction and stiffness were extracted from parametric maps by regions of interest and ECV was calculated from T1 relaxometries. Serum markers of liver disease were obtained by clinical database research. For correlation analysis, Spearman rank correlation was used. ROC analysis of serum markers and quantitative MRI data for discrimination of liver cirrhosis was performed with MRE as reference standard.Results109 participants were enrolled (50.7 ± 16.1 years, 61 men). ECV, T1 and MRE correlated significantly with almost all serum markers of liver disease, with ECV showing the strongest associations (up to r = 0.67 with MELD, p < 0.01). ECV and T1 correlated with MRE (0.75 and 0.73, p < 0.01 each). ECV (AUC 0.89, cutoff 32.2%, sensitivity 85%, specificity 87%) and T1 mapping (AUC 0.85, cutoff 592.5 ms, sensitivity 83%, specificity 75%) featured good performances in detection of liver cirrhosis with only ECV performing significantly superior to model of end stage liver disease (MELD), AST/ALT ratio and international normalized ratio (p < 0.01, respectively).ConclusionQuantification of hepatic extracellular volume fraction with MRI is suitable for estimating the severity of liver disease when using MRE as the standard of reference. It represents a promising tool for non-invasive assessment of liver fibrosis and cirrhosis.  相似文献   

15.
A model is presented which calculates the intrinsic envelope power of a bandpass noise carrier within the passband of a hypothetical modulation filter tuned to a specific modulation frequency. Model predictions are compared to experimentally obtained amplitude modulation (AM) detection thresholds. In experiment 1, thresholds for modulation rates of 5, 25, and 100 Hz imposed on a bandpass Gaussian noise carrier with a fixed upper cutoff frequency of 6 kHz and a bandwidth in the range from 1 to 6000 Hz were obtained. In experiment 2, three noises with different spectra of the intrinsic fluctuations served as the carrier: Gaussian noise, multiplied noise, and low-noise noise. In each case, the carrier was spectrally centered at 5 kHz and had a bandwidth of 50 Hz. The AM detection thresholds were obtained for modulation frequencies of 10, 20, 30, 50, 70, and 100 Hz. The intrinsic envelope power of the carrier at the output of the modulation filter tuned to the signal modulation frequency appears to provide a good estimate for AM detection threshold. The results are compared with predictions on the basis of the more complex auditory processing model by Dau et al.  相似文献   

16.
Melodic contour identification was measured in cochlear implant (CI) and normal-hearing (NH) subjects for piano samples processed by four bandpass filters: low (310-620 Hz), middle (620-2480 Hz), high (2480-4960 Hz), and full (310-4960 Hz). NH performance was near-perfect for all filter ranges and much higher than CI performance. The best mean CI performance was with the middle frequency range; performance was much better for some CI subjects with the middle rather than the full filter. These results suggest that acoustic filtering may reduce potential mismatches between fundamental frequencies and harmonic components thereby improving CI users' melodic pitch perception.  相似文献   

17.
This paper discusses the effect of pre-processing image blurring on the uncertainty of two-dimensional digital image correlation (DIC) measurements for the specific case of numerically-designed speckle patterns having particles with well-defined and consistent shape, size and spacing. Such patterns are more suitable for large measurement surfaces on large-scale specimens than traditional spray-painted random patterns without well-defined particles. The methodology consists of numerical simulations where Gaussian digital filters with varying standard deviation are applied to a reference speckle pattern. To simplify the pattern application process for large areas and increase contrast to reduce measurement uncertainty, the speckle shape, mean size and on-center spacing were selected to be representative of numerically-designed patterns that can be applied on large surfaces through different techniques (e.g., spray-painting through stencils). Such “designer patterns” are characterized by well-defined regions of non-zero frequency content and non-zero peaks, and are fundamentally different from typical spray-painted patterns whose frequency content exhibits near-zero peaks. The effect of blurring filters is examined for constant, linear, quadratic and cubic displacement fields. Maximum strains between ±250 and ±20,000 µε are simulated, thus covering a relevant range for structural materials subjected to service and ultimate stresses. The robustness of the simulation procedure is verified experimentally using a physical speckle pattern subjected to constant displacements. The stability of the relation between standard deviation of the Gaussian filter and measurement uncertainty is assessed for linear displacement fields at varying image noise levels, subset size, and frequency content of the speckle pattern. It is shown that bias error as well as measurement uncertainty are minimized through Gaussian pre-filtering. This finding does not apply to typical spray-painted patterns without well-defined particles, for which image blurring is only beneficial in reducing bias errors.  相似文献   

18.
This paper describes a series of experiments to determine the effects of vibration frequency, viewing distance and multiple frequency motions on the reading of numeric characters. Contours of vertical (z-axis) whole-body vibration levels resulting in equal degradation of the reading task were determined over the frequency range 2·8 Hz to 63 Hz. With the seating condition employed, the task was found to be most sensitive to vibration acceleration at a frequency of 11·2 Hz. A marked correlation was observed between reading error and reading speed. The effects of vibration on reading performance were found to be dependent on viewing distance for distance of less than 1·5 m, with the effect increasing as the viewing distance was decreased. The effect of 3·15 Hz vibration was found to increase more rapidly with reductions in viewing distance than that of 16 Hz vibration. The effects of 3·15 and 16 Hz vibration were independent of viewing distance greater than 1·5 m, indicating that the effects of rotational eye motion are dominant at these distances. Four methods were compared for predicting the effects of multiple frequency motion on reading performance given a knowledge of the effect of each component alone. The best predictions of reading error were obtained from the most severe weighted spectral component alone. Inspection of individual subject's data suggests that in many cases the effect of multiple frequency vibration on reading is even less than the effect of the largest sinusoidal component alone.  相似文献   

19.
基于微机电系统工艺,设计并制作了一种电磁驱动大尺寸的二维扫描振镜.分析了两种不同的电磁驱动方式产生的力的大小,选择驱动力较大的双极子方式作为驱动.运用有限元法模拟了器件的谐振频率静态及动态响应,仿真结果与实际测得的结果一致.描述了振镜的工艺流程及封装方式,并制备了振镜.实验测得振镜在120mA静态电流驱动下,慢轴和快轴分别能达到的最大转角为±4.5°及±5°,慢轴及快轴的谐振频率分别为348Hz及660Hz,并得到在此谐振频率下的李萨如图形.将器件用于激光成像系统之中,使得散斑对比度下降到4.2%,激光成像质量得到很大提升.  相似文献   

20.
Driving point mechanical impedance measurements were used to determine the dynamic response of the human head to sinusoidal vibration in the frequency range between 30 Hz and 5000 Hz at excitation levels of 0·98 m/s2 and 3·4 m/s2. Because of the low excitation levels, the weight of the head was sufficient to couple the head to the vibration source.At 20 Hz the impedance magnitude was about 790 N-s/m but increased at approximately 6dB/octave to a peak near 3500 N-s/m at 70–90 Hz. Between 100 Hz and 2000 Hz impedance decreased by about two orders of magnitude while the apparent mass decreased by three orders of magnitude indicating good vibration isolation at higher frequencies. The impedance response contains the information for modelling the head as a dynamic system.The response of the head to vibration can be simulated by a two degree-of-freedom, mass-excited system consisting of a series connection of a small driving mass, a damper, a spring and damper in parallel and a large final mass. Parameter values, derived by computer techniques, suggest that the large mass represents the total head, the small mass the tissue in contact with the vibration input and the spring the skull stiffness.  相似文献   