首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
A number of new crown-formazans with 14 and 15 membered rings have been investigated as selective neutral carriers in cesium ion selective electrodes. Two plasticizers (NPOE and NPBnE) were studied. The new 14-crown-formazan 4a containing the 4-pyridyl N-oxide at the formazyl carbon exhibited the highest selectivity in cesium ion selective electrodes, especially towards the two low selectivity monovalent ions K+ and NH4+. Also, membranes containing the plasticizer NPBnE showed better cesium selectivity relative to most ions than those containing NPOE. Membranes containing 4a and variable compositions of plasticizers, potassium tetrakis-(p-chlorophenyl)borate (KTpClPB), and trioctylphosphine oxide (TOPO) were studied in order to prepare an electrode with the optimum cesium selectivity. The highest selectivity for cesium was achieved with the two electrodes designated d and e with membranes containing the ionophore 4a, NPBnE and KTpClPB with and without TOPO. Selectivities are reported relative to sodium, potassium, barium, calcium, ammonium, lithium, cobalt, and magnesium.  相似文献   

2.
A method for determining specific amino acids is described, based on the detection of the amine formed by the enzymatic reaction of an amino acid with decarboxylase, using an amine-sensitive membrane electrode. l-Tyrosine and l-phenylalanine are considered as examples. The corresponding amines tyramine and phenethylamine, respectively, were selectively detected by using a poly(vinyl chloride)-based membrane electrode containing sodium tetrakis[3,5- bis(trifluoromethyl)phenyl]borate as an ion exchanger and tricresyl phosphate as a solvent mediator. The detection limits of l-tyrosine and l-phenylalanine were 20 and 50μM, respectively. The response characteristics of electrodes were compared by changing ion exchangers and solvent mediators.  相似文献   

3.
A simple and robust approach for the development of solid-state ion-selective electrodes (ISEs) using nanomaterials as solid contacts is described. The electrodes are fabricated by using the mixture of an ionic liquid (IL) and a nanomaterial as intermediate layer, formed by melting the IL. Tetradodecylammonium tetrakis(4-chlorophenyl)borate (ETH 500) is chosen as an model of IL to provide strong adhesion between the inner glassy carbon electrode and the intermediate layer. Nanomaterials including single-walled carbon nanotubes (SWCNTs) and graphene were used as active ion-to-electron transducers between the glassy carbon electrode and the ionophore-doped ISE membrane. By using the proposed approach, the solid-contact Cu2+- and Pb2+-selective electrodes based on ETH 500/SWCNTs and ETH 500/graphene as transducers, respectively, have been fabricated. The proposed electrodes show detection limits in the nanomolar range and exhibit a good response time and excellent stability.  相似文献   

4.
Saad B  Kanapathy K  Ahmad MN  Hussin AH  Ismail Z 《Talanta》1991,38(12):1399-1402
Three main types of PVC solvent polymeric membrane ion-selective electrodes for chloroquine are described. They are based on three ion-pairing agents namely dipicrylamine (DPA), tetraphenylborate (TPB) or tetrakis(4-chlorophenyl)borate (TCPB) with either dioctylphenyl phosphonate (DOPP) or trioctyl phosphate (TOP) solvent mediator. All electrodes exhibit Nernstian responses, fast dynamic response times and a wide useful pH range. The best all-round electrode is based on TPB and TOP plasticizing solvent mediators with a limit of detection of 7.1 × 10−6M and was utilized for the assay of chloroquine in tablets. Direct potentiometric determinations with either the analyte addition method or the normal calibration method gave results comparable to the official method.  相似文献   

5.
Five aromatic borate anions, namely tetrakis(4-phenoxyphenyl)borate (1), tetrakis(biphenyl)borate (2), tetrakis(2-naphthyl)borate (3), tetrakis(4-phenylphenol)borate (4), and tetrakis(4-phenoxy)borate (5), have been prepared and tested as ion-recognition sites in chemical sensors for certain aromatic cations and metal ions. To gain further insight into the complexation of the cations, some complexes have been prepared and structurally characterized. The complexation behavior of 1 and 2 towards N-methylpyridinium (6), 1-ethyl-4-(methoxycarbonyl)pyridinium (7), tropylium (8), imidazolium (9), and 1-methylimidazolium (10) cations has been studied, and the stability constants of the complexes of 1 with cations 6 and 8 have been measured to compare them with the values for the previously studied complexes of tetraphenylborate. The structures of the borate anions and their complexes have been characterized by NMR and mass spectrometric methods. X-ray crystal structures have been determined for potassium tetrakis(4-phenoxyphenyl)borate (K(+)1), N-methylpyridinium tetrakis(4-phenoxyphenyl)borate (61), 1-ethyl-4-(methoxycarbonyl)pyridinium tetrakis(4-phenoxyphenyl)borate (71), tropylium tetrakis(4-phenoxyphenyl)borate (81), and imidazolium tetrakis(biphenyl)borate (92). The results show that borate derivatives are potential candidates for a completely new family of charged carriers for use in cation-selective electrodes.  相似文献   

6.
全固膜选择性电极(All solid-state selective electrode,ASSE)综合晶体电极和膜电极的优点,具有线性范围宽、检测限低,能真实地体现膜性能等特点,ASSE主要有涂线电极(Coated wire electrode,CWE)、填充固体电解质或配合物的膜电极和电沉积型聚合物膜电极等。  相似文献   

7.
Saleh MB 《Talanta》1998,46(5):885-895
Cesium ion-selective PVC membrane electrodes based on anilino-(1,3-dioxo-2-indanylidene) acetonitrile derivatives as a novel class of neutral ionophores were examined. The ionophores were p-methoxyanilino-(1,3-dioxo-2-indanylidene) acetonitrile, p-methylanilino-(1,3-dioxo-2-indanylidene) acetonitrile and p-N,N-dimethylanilino-(1,3-dioxo-2-indanylidene) acetonitrile. The anilino-(1,3-dioxo-2-indanylidene) acetonitrile proved to work well with cesium, the corresponding electrodes display a response to this ion. The most favourable ionophore was p-methoxyanilino-(1,3-dioxo-2-indanylidene) acetonitrile, especially when the secondary ion exchanger potassium tetrakis (4-chlorophenyl) borate was incorporated in 2-nitrophenyl octyl ether for ion-selective electrode membrane construction. The response function was linear within the concentration range 10(-1)-2.5x10(-5) mol l(-1) and the slope was 52 mV decade(-1). The detection limit remained at 6.3x10(-6) mol(-1). The selectivity and response time of the electrode was studied and it was found that the electrode exhibited good selectivity for cesium over alkali, alkaline earth and some transition metal ions. The electrode response was stable over a wide pH range. The lifetime of the electrode was about 1 month.  相似文献   

8.
The halochromic product from di-(p-fluorophenyl) -trifluoromethylcarbinol and sulphuric acid gives with ethyl mercaptan 3-ethylthio-6 fluoro-9-trifluoromethylfluorene. Analogous reactions have been observed with (p-chlorophenyl)-(p-fluorophenyl)-, with (p-fluorophenyl)-phenyl-. and with diphenyl-trifluoromethyl-carbinol.

The infra-red spectra of the fluorene derivatives formed are discussed.  相似文献   


9.
Two hydroxyurea selective electrodes were investigated with beta-cyclodextrin used as ionophore and either tetrakis (p-chlorophenyl) borate (electrode 1), or tetrakis [3,4-bis (trifluoromethyl) phenyl] borate (electrode 2), as a fixed anionic site in a polymeric matrix of carboxylated polyvinyl chloride. Linear responses of hydroxyurea within a concentration range of 10(-5)-10(-)3 M with slopes of 51.2 and 58.6 mV/decade with pH 3-6 were obtained by using electrodes 1 and 2, respectively. Two spectrofluorimetric methods involving the formation of drug-AI(III) complex (method 3) and drug-Mg(II) complex (method 4) at pH 5 were also investigated. These complexes emit fluorescence at wavelengths of 380 and 355 nm, after excitation at 305 nm, for AI and Mg complexes, respectively. The calibration graphs were rectilinear from 0.5 to 2.5 microg/mL for the AI complex and 1 to 5 microg/mL for the Mg complex. The 4 proposed methods display useful analytical characteristics for determination of hydroxyurea, with average recoveries of 100.2 +/- 0.83 and 99.4 +/- 1.81% in capsules and 99.7 +/- 0.70 and 99.4 +/- 1.25% in biological fluids for the potentiometric and fluorimetric methods, respectively. Results obtained by the proposed procedures were statistically analyzed and compared with those obtained by the U.S. Pharmacopeial method. The 4 proposed procedures were also used to determine the stability of the drug in the presence of its degradate, hydroxylamine.  相似文献   

10.
Bis(crown ether)-based ion-selective electrodes for sodium and potassium are described, based on the bis[(12-crown-4)-2-ylmethyl]-2-dodecyl-2-methyl malonate sensor(I) for sodium and the bis[(benzo-15-crown-5)-15-ylmethyl] pimelate sensor(II) for potassium. The best results were obtained when the sensors were used in association with 2-nitrophenyl octyl ether as plasticising solvent mediator and potassium tetrakis(4-chlorophenyl)borate as anion excluder in poly(vinyl chloride) matrices. Electrode slopes were near-Nernstian, with detection limits of less than 10(-5) M. The electrode features are compared with those of a sodium glass membrane electrode, for sensor I, and with a valinomycin-based potassium electrode, for sensor II. The electrodes are also discussed in relation to others reported for sensors I and II and are shown to be superior. However, although the electrodes described offer promising alternatives to glass electrodes for sodium and valinomycin electrodes for potassium, data for sodium and potassium measurements in blood serum indicate a need for further research in order to improve the correlation with flame photometric measurements.  相似文献   

11.
Xu D  Katsu T 《Talanta》2000,51(2):365-371
Tetrabenzyl pyrophosphate and diphenylphosphinic anhydride, with two phosphoryl groups (PO) as ligating sites, can be used as novel ionophores to make Pb(2+)-selective membrane electrodes. A good result was obtained with tetrabenzyl pyrophosphate, and the electrode based on this ionophore and bis(1-butylpentyl) adipate as a solvent mediator in a poly(vinyl chloride) membrane matrix exhibited a near-Nernstian response to Pb(2+) in the concentration range of 1x10(-5)-1x10(-2) M with a slope of 28.7 mV per concentration decade in a solution containing 0.1 M Mg(NO(3))(2). The limit of detection was 3x10(-6) M. The selectivity of this electrode to other metal cations was comparable to the best case in many Pb(2+)-selective electrodes so far developed. Addition of potassium tetrakis(p-chlorophenyl)borate (40 mol% relative to tetrabenzyl pyrophosphate) caused a drastic change in the response slope (53.3 mV per concentration decade), probably due to the formation of PbA(+), where A stands for anions present in the sample solution, and decreased significantly the electrode selectivity to other metal cations.  相似文献   

12.
The effect of measurement conditions and the nature of the plasticizer of an ion-selective electrode membrane (ortho-nitrophenyloctyl ether, dinonyl adipate, dibutyl phthalate) on the main performance characteristics of clotrimazole-selective electrodes with polyvinyl chloride ion-exchange membranes containing potassium tetrakis(4-chlorophenyl)borate as an ion exchanger was studied. The introduction of small (up to 20%) ethanol additives into the aqueous solution leads to a significant improvement of the potential stability and expands the working range of the electrodes. All of the studied electrodes have high selectivity to clotrimazole with respect to both inorganic and organic cations, slope of the electrode function close to the theoretical value, and low limits of detection (5.0 × 10–8–7.5 × 10–8 M). An electrode with a membrane plasticized with ortho-nitrophenyloctyl ether was the best for the combination of characteristics. It was demonstrated that clotrimazole can be determined in model solutions and various dosage forms (spray, cream, suppositories, tablets) using direct potentiometry and potentiometric titration with sodium tetraphenylborate. The proposed procedures are rapid (10–15 min) and characterized by excellent reproducibility (the relative standard deviation does not exceed 1.2%).  相似文献   

13.
A flow injection set-up based on potentiometric detection and gas diffusion device for the determination of total nitrogen in food is described. The detection system consisted of two ammonium-sensitive electrodes placed sequentially and each alternately operating as reference electrode. Tubular electrodes without an inner reference solution were prepared with a PVC membrane composed of nonactin in Tris (2-ethylhexyl) phosphate and potassium tetrakis (4-chlorophenyl) borate to reduce the membrane resistance. The food sample digests were inserted into the system, and the ammonium present was converted into ammonia gas. The gas diffused through a gas-permeable membrane to a buffer acceptor stream with a pH that ensured transformation to the ammonium cation, which was potentiometrically detected. Good agreement between FIA results and those provided by the reference procedure was obtained, with relative deviation errors below 5%. Using the proposed system, low reagent consumption is possible, a sampling rate of about 30 samples/h was achieved, as well as a good reproducibility for consecutive injections of the same sample (variation coefficient < 2%).  相似文献   

14.
A flow injection set-up based on potentiometric detection and gas diffusion device for the determination of total nitrogen in food is described. The detection system consisted of two ammonium-sensitive electrodes placed sequentially and each alternately operating as reference electrode. Tubular electrodes without an inner reference solution were prepared with a PVC membrane composed of nonactin in Tris (2-ethylhexyl) phosphate and potassium tetrakis (4-chlorophenyl) borate to reduce the membrane resistance. The food sample digests were inserted into the system, and the ammonium present was converted into ammonia gas. The gas diffused through a gas-permeable membrane to a buffer acceptor stream with a pH that ensured transformation to the ammonium cation, which was potentiometrically detected. Good agreement between FIA results and those provided by the reference procedure was obtained, with relative deviation errors below 5%. Using the proposed system, low reagent consumption is possible, a sampling rate of about 30 samples/h was achieved, as well as a good reproducibility for consecutive injections of the same sample (variation coefficient < 2%). Received: 8 October 1998 / Revised: 7 January 1999 / Accepted: 12 January 1999  相似文献   

15.
Data for coated-wire, ion selective electrodes (ISEs) are presented for cationic surfactant ions found in common cleaners including benzyldimethyltetradecylammonium, benzyldimethyldodecylammonium, and benzyldimethylhexadecylammonium. The ion exchangers dinonylnaphthalene sulfonic acid, tetraphenyborate, and tetrakis(4-chlorophenyl)borate are examined, showing dinonylnaphthalene sulfonic acid to be the favored species. The ISEs exhibit approximately Nernstian behavior down to the 10−6 M limit of detection with lifetimes in excess of 50 days when used continuously, and a shelf life of over 100 days. Reaching the upper detection limit at the critical micelle concentration requires use of polymeric-membrane reference electrodes including a new membrane cocktail, which allow response measurements of an order of magnitude higher than the traditional fritted-glass reference electrode. The surfactant ISEs show excellent selectivity over the common metal ions Na+, K+, Mg2+, Ca2+, and Cu2+ with selectivity coefficients less than 10−5.3. The ISEs are also selective over the lower molecular weight quaternary ammonium ions tetradecyltrimethylammonium, dodecyltrimethylammonium, benzyldimethyl(2-hydroxyethyl)ammonium, and tetrabutylammonium with selectivity coefficients ranging from 10−1.7 to 10−5.5. Use of a single electrode to determine accurately the total cationic surfactant concentration in common cleaning solutions is accomplished with information about concentration dependent interferences and a modified Nikolsky–Eisenman model. Finally, quaternary ammonium surfactants have a deleterious effect on the measurements of pH and common ions like K+, Mg2+ and Ca2+ with polymeric ISEs. This makes it critical to include surfactant electrodes in a detector array when cleaning agents are present.  相似文献   

16.
Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0?×?10?5 to 1.0?×?10?2?mol/L (10.0 to 2500?µg/mL), and the limit of detection was 1.2?×?10?5?mol/L (3.0?µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15?s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.  相似文献   

17.
Rung-Yi Lai 《Tetrahedron》2008,64(7):1213-1217
A combination of sodium tetrakis[3,5-di(trifluoromethyl)phenyl]borate [NaBArF4] and hydrio-iridium(III) complex efficiently catalyzed the one-pot reductive amination of aldehydes with various amines and ammonia in water under mild conditions in good to excellent yields.  相似文献   

18.
《Analytica chimica acta》1995,316(3):371-375
The sensitivity and selectivity of a cocaine-selective membrane electrode have been improved with the use of sodium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate as an ion-exchanger and tetrakis(2-ethylhexyl) pyromellitate (TEHPY) as a solvent mediator. The use of TEHPY suppressed the responses to lipophilic quaternary ammonium ions and strengthened the response to cocaine. The electrode exhibited a near-Nernstian response over a concentration range of 10−2to 10−6 M cocaine with a slope of 56 mV per decade. The lower limit of detection was 4 × 10−7 M cocaine. Interference by other drugs (morphine and codeine) and a stimulant (methamphetamine) was negligible. This electrode was applied for the determination of cocaine in a drug mixture containing cocaine and morphine, which is widely used to suppress acute pain in cancer patients. The concentration of cocaine, different in each patient, was measured precisely with an average recovery of 99.9% and a mean relative standard deviation of 0.56%.  相似文献   

19.
The construction and performance characteristics of an ion-selective electrode for fentanyl-drug cation, based on an ion-pair complex with tetrakis[3,5-bis-(trifluoromethyl)phenyl]borate anion in a PVC matrix were studied. A linear response for 1 x 10(-5) mol dm-3 to 1 x 10(-2) mol dm-3 drug with a slope of 57.9 +/- 0.5 mV/decade was established. The optimum pH range was 2 to 6. The lower detection limit was 6.29 x 10(-6) mol dm-3 fentanyl citrate (2.1165 micrograms cm-3 fentanyl). There were negligible interferences from a number of inorganic cations, structural analogues, and some common drug additives in injections. The electrode proposed has been successfully applied to determine fentanyl citrate in injections. The results correlated well with those obtained by the United States Pharmacopoeia standard procedure.  相似文献   

20.
Isocratic HPLC with potentiometric detection is used for the determination of some 17‐ketosteroids (17‐KS), e.g., androsterone, dehydroepiandrosterone and estrone, and their respective sulfated conjugates (17‐KSS). Glassy carbon or composite electrodes containing a mixture of graphite and poly(vinyl chloride), PVC, were used as substrate electrodes. These substrates were covered either by montmorillonite or potassium tetrakis(p‐chlorophenyl) borate containing PVC‐based rubber phase membranes. The neutral 17‐KS compounds were derivatized with Girard's reagent P (GP) to obtain cationic pyridinium acetohydrazones prior to the HPLC/potentiometric detection assay. No side reactions were observed, and the GP itself was not interfering. The method yielded accurate and reproducible results and was applicable to samples containing down to micromolar concentrations. Next, the 17‐KSS compounds, acting as anionic charged molecules, were determined directly in human urine samples with the HPLC/potentiometry combination without preliminary derivatization. For this purpose, a new anion‐sensitive potentiometric electrode was developed using a macrocyclic polyamine containing, PVC‐based, rubber phase membrane. The three 17‐KSS compounds were also determined accurately down to micromolar concentrations. Especially, the main androgen metabolites as dehydroepiandrosterone sulfate and androsterone sulfate could be selectively determined with a developed potentiometric sensor in human urine samples without time‐consuming cleanup and preconcentration step.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏