首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 156 毫秒
1.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

2.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

3.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

4.
In this study, a syringe-connected minicolumn resin was used for the separation and enrichment of cadmium, copper, nickel and zinc prior to their determination by flame atomic absorption spectrometry. The proposed technique was compared with classical batch and column techniques in terms of rapidness, simplicity, enrichment and risk of contamination. The minicolumn was filled with Chromosorb-103 resin and connected to a syringe. If the samples were treated with ammonium pyrrolidine dithiocarbamate or 8-hydroxyquinoline, the analytes were quantitatively retained at pH2 and pH5 on the resin, respectively. On the other hand, if no chelating agent was added, the analytes were quantitatively retained at pH10. The analytes retained by the resin were quantitatively eluted by drawing and discharging nitric acid in acetone. The analytes in spiked river-water samples and in certified standard reference Bovine-Liver (NIST SRM 1577 b) were quantitatively (94%) recovered. The relative standard deviations for the determinations were found to be 1.0–10%.  相似文献   

5.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

6.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

7.
A single-wall carbon nanotubes (SWNT) film coated glassy carbon electrode (GCE) was fabricated for the direct determination of 4-nitrophenol (4-NP). The electrochemical behaviors of 4-NP at the SWNT-film coated GCE were examined. In 0.1M phosphate buffer with a pH of 5.0, 4-NP yields a very sensitive and well-defined reduction peak at the SWNT-modified GCE. It is found that the SWNT film exhibits obvious electrocatalytic activity towards the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. The reduction peak current varies linearly with the concentration of 4-NP ranging from 1×10–8 to 5×10–6M, and the detection limit is 2.5×10–9M after 3min of open-circuit accumulation. The relative standard deviation at 2×10–7M 4-NP was about 6% (n=10), suggesting excellent reproducibility. This new method was successfully employed to determine 4-NP in several lake water samples.  相似文献   

8.
A flow-injection procedure for the determination of iron(III) in water is described. The procedure is based on the formation of an ion pair between the tetraphenylarsonium (Ph4As+) (TPA) or tetrabutylammonium (But4N+) (TBA) cations and the tetrathiocyanatoferrate(III) complex (TTF). This ion pair is extracted with chloroform, and the absorbance of the organic phase is measured at 503nm (for Ph4As+) or 475nm (for But4N+). Iron concentrations higher than 0.9×10–6molL–1 (50µgL–1) can be detected in the first case, with a relative standard deviation of 1.9% (n=12), a linear application rangeof between 1.34 and 54.0×10–6molL–1 (75–3015µgL–1), and a sampling frequency of 30h–1. For the ion pair with But4N+, the detection limit is 0.52×10–6molL–1 (29µgL–1), with a relative standard deviation of 1.6% and a linear application range between 0.73 and 54.0×10–6molL–1. Under the proposed working conditions, only Pd(IV), Cu(II) and Bi(III) interfere. With the application of the merging zones technique, considerable amounts of organic reagent can be saved. The TBA method was applied to the analysis of iron(III) in tap and industrial waste waters.  相似文献   

9.
A flow injection hydride generation graphite furnace atomic absorption spectrometric (FI-HG-GFAAS) method was applied to the determination of Se in Se-doped and undoped cereals and bakery products. For the purpose of doping, the soils used for the cultivation of the cereals were dosed with Se-doped foliar fertilizers. The samples were dissolved in a mixture of HNO3 and H2O2 solutions using microwave-assisted digestion. The decomposition of H2Se generated from the sample solutions and the trapping of elemental Se were performed at a temperature of 300°C on an Ir-pretreated integrated graphite platform of a transversally heated graphite atomizer (THGA). For release of the trapped Se within a fairly short atomization time (5s), an atomization temperature of 2200°C was observed to be optimal. The overall efficiency of hydride generation, transport and trapping was 86%.The upper limit of the linear dynamic range of calibration was 10µgL–1, which corresponds to 0.5µgg–1 for solid samples. Recovery of the samples spiked with SeVI solutions was found to be 93±6% on average. The relative standard deviation of the determinations was less than 8%. The limit of detection was found to be 0.06µgL–1, corresponding to 3ngg–1 for solid samples. The accuracy of the method was verified with the use of IAEA-155 (whey powder) certified reference material. End-capped THGA tubes resulted in an extension of the linear calibration range compared to that of standard THGAs.The Se content in bakery products made of undoped cereals ranged from 7.7 to 68ngg–1 (wet weight) in 18 samples, whereas the Se content of the corresponding cereals was found to be below 100ngg–1 (wet weight). The Se level of cereals grown on soils treated with Se-doped fertilizers ranged from 128 to 1046ngg–1 (wet weight), and it depended linearly on the Se concentration of the corresponding foliar fertilizer.  相似文献   

10.
A sub-micrometer thin-layer DNA modified carbon fiber microcylinder electrode was prepared by electrodeposition of ct-DNA at 1.5V (vs. Ag/AgCl). The voltammetric behavior of dopamine (3-hydroxytyramine) was investigated at the modified electrode. It was found that the modified electrode exhibits a highly electrocatalytic activity toward dopamine oxidation. Differential pulse voltammetry was used for determination of dopamine in pH 7.4 phosphate buffer solution. A linear response of the peak current versus the concentration was found in the range of 4×10–6 to 10–4molL–1 at 10–4molL–1 AA (ascorbic acid) coexistence (R=0.9959) and the range of 6×10–5 to 10–3molL–1 at 10–3molL–1 AA (R=0.9960). The presence of a high concentration of ascorbic acid did not interfere with the determination. The proposed method exhibited good recovery and reproducibility. This method can be applied to the detection of DA in real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号